  1. 1. Forma Light by
  2. 2. Forma Light Forma Light is an innovative IPL Unit developed to treat a range of medical-aesthetic applications
  3. 3. Forma Light Highlight      Full control over electro physical parameters such as pulse duration, pulse wide and flunce energy . Pre setting features based on the patient skin type Treatments for all skin type Innovative design including touch screen Shortest pulse duration
  4. 4. Forma Light Highlight       System weight just 8.9kg Light & ergonomic Applicator Large tip for large area treatments Multilingual support The highest quality in competitive price 4 colors to choose from
  5. 5. Forma Light Applications        Hair Reduction Skin Rejuvenation Pigmented Lesion Vascular Lesions Skin Lightening Onychmycosis Acne
  6. 6. Applicators IPL F- HR 590nm IPL F- HR 650nm IPL F- SR 530nm IPL F-AC 440 nm IPL B- HR 590nm IPL B - HR* 650nm IPL HR 590nm IPL HR* 650nm IPL SR 530nm Application up to pulses up to pulses up to pulses up to pulses up to pulses up to pulses 60,000 up to 120,000 pulses 60,000 up to 120,000 pulses 60,000 up to 120,000 pulses 1.6cm2 Hair Reduction 1.6cm2 Hair Reduction 1.6cm2 1.6cm2 Skin rejuvenation, Pigmented/Vascular Lesions Acne 3 cm2 Hair Reduction 3 cm2 Hair Reduction 6.5cm2 Hair Reduction 6.5cm2 Hair Reduction 6.5cm2 Skin rejuvenation, Pigmented lesions
  7. 7. Intense Pulse Light -IPL Wavelength
  8. 8. Intense Pulse Light and Thermal Relaxation Time - TRT  Represents the time taken for heated tissue to lose 50% of its heat through diffusion  If the light energy persists longer than TRT of the target, heat is conduced to the surrounding tissue leading to unwanted thermal injury. (Katsambas & Lotti, 2003).
  9. 9. TRT in Pigmented and Vascular lesions Data & histological assessment of vessel injury strongly suggest that pulse durations for ideal light treatment are in the 1 – 10ms region and depend on vessel diameter (Diedrickx, 1995).  Correct wavelength combine with correct TRT will achieve quick coagulation of targeted chromophore (melanin/hemoglobin). If TRT is exceeded, same clinical consistence is not achieved and more treatments sessions are necessary.   Pulse wide choice is as important as that of the wavelength. (X.Muller, Lasers for Ischemic Heart Disease,2000)
  10. 10. Forma Light – enjoy from all options Innovation in Technology Shortest pulse duration below 10 ms to in respect of Thermal Relaxation Time parameters, and Long pulse for dark skin HR
  11. 11. Forma Light Innovation in Technology Fluence = [Power] Area of Spot x Time (Pulse Duration) (Energy Density) Because of the short pulse reaches the highest intensity
  12. 12. Forma Light Applicators
  13. 13. B/F HR – Hair removal  Body and face hair removal.  2 modes pulse of work: single, double pulse. Technical information:  Energy: up to 20 j/cm2.  Wavelength: 590/650 nm  Spot size: body 3cm²/6.5cm², face 1.6cm² Pulse duration:  Single: from 3 to 10 milliseconds (for 3cm² and 1.6cm²)  Double: from 2 to 5 milliseconds (for 3cm² and 1.6cm²)  For the 6.5cm² 20 milliseconds and up
  14. 14. Results after three treatments Before After
  15. 15. Results after one treatment Before After (one month)
  16. 16. Results after 3 treatments Before After
  17. 17. B/F SR –Skin Rejuvenation   Body and face Skin Rejuvenation and Fungus Treatment 2 modes of work: single pulse, double puls (single pulse every 0.33 seconds). Technical information:    Energy: up to 22 j/cm. Wavelength: 530 nm Spot size: body 3 cm²/6.5², face 1.6 cm² Pulse duration:    Single: from 3 to 10 milliseconds (for 3cm² and 1.6cm²) Double: from 2 to 5 milliseconds (for 3cm² and 1.6cm²) For the 6.5cm² 20 milliseconds and up
  18. 18. Pigmentation & skin rejuvenation Before After (3 treat.)
  19. 19. Onychomycosis treatment Before After
  20. 20. Pigmentation & Skin rejuvenation Before After (3 treat.)
  21. 21. Combination of Peeling and IPL 3 treatments Before After
  22. 22. Hands pigmentation one treatment Before After
  23. 23. Onychomycosis (4 treatments) Before After
  24. 24. Onychomycosis (4 treatments) Before After
  25. 25. F–AC Acne treatment  Face acne treatment Technical information:  Energy: up to 22 j/cm.  Wavelength: 440 nm  Spot size: 1.6 cm2 Pulse duration:  Single: from 2 to 6 milliseconds  Double: from 1.5 to 3 milliseconds
  26. 26. Acne treatment with F-AC Before After
  27. 27. Acne treatment with IPL Before After
  28. 28. R-sonic combined with IPL-SR under eye dark circle, 3 treatment performed once a week Before After (three week)