  1. 1. Enabling OVS Hardware Offload using LiquidIO Manoj Panicker – Cavium, Inc November 16-17, 2017 | San Jose, CA
  2. 2. OVS Fall conference 2017 Open vswitch software models vswitchd OVS utilities OVS data path kernel module ovsdb-server Netfilter NIC VM Host OS User Space Kernel VM NIC DPDK PMD OVS DPDK DPDK vhost-user Host OS User Space • Two different models – • Data plane in kernel; Control in user space; Packets switched within kernel to VM. • Data and control plane in user space; Packets bypass kernel completely; Packets switched entirely in user space. • Both models supported by open source community • Hardware independent OVS Fall conference 2017
  3. 3. OVS Fall conference 2017 Why move vSwitch out of the host? Customers need a resolution to some or all of the above issues in their current deployment. § Cavium’s customers also had other reasons to offload vSwitch to a NIC adapter Ø Manage vSwitch independent of host OS. Host OS could be under tenant control. Ø Upgrade or manage OVS or customization to vSwitch without modifying host OS. Limitations with a pure software based vSwitch • Requires significant host CPU cycles to get packets to the VM. • Reduces host CPU cores available to run VMs. • Challenge in keeping up with increasing bandwidth requirements.
  4. 4. OVS Fall conference 2017 Models to offload Open vSwitch to NIC adapters • Data plane offload model § Uses PCI pass-through of VF to VM to bypass host CPU. § OVS Control plane continues to be on host OS. § The vswitch bridge exists in the host § Uses representors of the VFs attached to VM as ports in the bridge. § Has enablers in the Linux kernel including support for o switchdev o TC/Flower based flow offload to network devices • Full Open vSwitch offload (control and data plane) § Leverages PCIe SRIOV and PCI pass-through of VF to VM to bypass host CPU. § The OVS control and data plane operate from within the NIC adapter § Does not require VF representors or switchdev for normal OVS operation. § This is the LiquidIO model
  5. 5. OVS Fall conference 2017 x86 Userspace x86 Kernel PCI Express Slot LiquidIO X86 Userspace X86 Kernel OVS-DB Server OVSDB port 1 port 2 PF PF eth0 eth1 Accelerated Data Path vSwitchd VM Apps VM Apps OVS Data path VM DPDK Apps VM DPDK Apps VM Apps Controller x86 Host LiquidIO accelerates OVS Data path and restores CPU cores back to the server LiquidIOOVS offload
  6. 6. OVS Fall conference 2017 The LiquidIO model SmartNIC adapter uses Cavium OCTEON III MIPS multi-core processorSupports OVS 2.6ovs-switchd and ovs-db server runs locally within LiquidIO Accelerated data path uses bare-metal application running on some cores Some cores run Linux and allow open source OVS control plane to run without modification. Inter-core messaging protocol allows control to data plane communication. Data Plane (SE) vswitchd OVS utilities mgmt0 eth0 eth1 CT table Flow table OVS kernel data path module Packet Rx/Tx DP/Vport/Flow Offload CT Offload Stats Offload Control Plane (Octlinux) ovsdb-server Netfilter OVSDB Messaging layer LiquidIO-OVS offload module LiquidIO-OVS CT offload vf0.n vf1.0vf0.0 Inter-core messaging vf1.n User Space Kernel Space Host PCIedriver pf0 pf1 VM 1 VM n X86 host
  7. 7. OVS Fall conference 2017 LiquidIO Open vSwitch offload • Data plane leverages acceleration for multi-core packet processing, packet parsing and scheduling provided by hardware. • Uses hardware support for implementing message passing layer. • Zero host CPU utilization for OVS processing. • Uses standard LiquidIO VF drivers in VM. No VF representor required. • Supports conntrack+ NAT. • Also supports encryption of network traffic.
  8. 8. OVS Fall conference 2017 LiquidIOOVS offload – life of a packet LiquidIO SE-S Kernel userspace vSwitchd OVS Kernel Module xaui0 xaui1 Kernel Userspace x86 OVS-DB Server mgmt0pf0 eth0 pf1 eth1 Data plane copy of OVS Flow table vf0.0 vf0.n vf1.0 vf1.n VM-1 OVS Flow table
  9. 9. OVS Fall conference 2017 LiquidIOOVS offload – conntrack LiquidIO SE-S Kernel userspace vSwitchd OVS Kernel Module xaui0 xaui1 Kernel Userspace Host OVS-DB Server mgmt0pf0 eth0 pf1 eth1 Data plane copy of OVS Flow table vf0.0 vf0.n vf1.0 vf1.n VM-1 OVS Flow table CT table Conntrack Module Data plane copy of CT table • Leverages conntrack module from the Linux kernel running on LiquidIO cores. • Message passing layer to keep copy of CT table in the data plane. • All packets continue to go to conntrack module in Linux kernel and decision made in kernel on flow update. • When connection gets to established state, the flow and CT table are updated in the data plane. • Once offloaded, CT state lookup happens in data plane. • Data plane supports timeout of CT entries
  10. 10. OVS Fall conference 2017 LiquidIO OVS customization – customer use cases LiquidIO support all standard OVS vswitch operations but customers need to tweak firmware to fit in their deployment. • Secure Access model § Deny host access to OVS running on LiquidIO. § OVS is remotely managed using proprietary management plane. • Custom tunneling protocols § Uses custom tunneling protocols instead of Vxlan, GRE. § Uses custom management plane. Control of OVS via network or from the local host. • Custom core vswitch § Uses custom data plane with modified flow tables. § Openflow is still used to apply rules. § Control plane applications are also customized. • IPSec support for VM payload § IKE runs in VM; xfrm offload module allows SA offload to LiquidIO. § LiquidIO can perform IPsec operation for VM traffic and encapsulate in tunnel as per OVS action.
  11. 11. OVS Fall conference 2017 LiquidIO OVS Offload – TCP performance Netperf TCP bi-directional (8 flows) with Vxlan LiquidIO VF in PCI passthrough, Intel with OVS+DPDK using virtio. 0 5 10 15 20 25 30 35 40 64 128 360 512 1024 THROUGHPUT (GBPS) PACKET SIZE LiquidIO OVS Offload Intel OVS + DPDK 0 5 10 15 20 25 30 35 64 128 360 512 1024 CPU UTILIZATION (GHZ) PACKET SIZE LiquidIO OVS Offload Intel OVS + DPDK Setup Dell T630 with 14 cores E5- 2690v4 @ 2.6 Ghz Host OS: CentOS 7.3 Guest OS: CentOS 7.3 2 VMs each with 4 vCPUs Adapters: Intel X710 10G – DA4 LiquidIO 2360-210 Intel tests with OVS+DPDK on 4 host CPUs. Tested with TCP traffic on 2 x 10G ports.
  12. 12. OVS Fall conference 2017 LiquidIO OVS Offload – UDP performance DPDK testpmd running Rx mode in VM (100 flows) LiquidIO VF in PCI passthrough, Intel with OVS+DPDK using virtio. 0 5 10 15 20 25 64 128 360 512 1024 THROUGHPUT (GBPS) PACKET SIZE UDP Performance LiquidIO OVS Bridge Intel OVS+DPDK Bridge LiquidIO OVS Vxlan Intel OVS + DPDK Vxlan Setup Dell T630 with 14 cores E5- 2690v4 @ 2.6 Ghz Host OS: CentOS 7.3 Guest OS: CentOS 7.3 Single VM with 4 vCPU Adapters: Intel X710 10G – DA4 LiquidIO 2360-210 Intel tests with OVS+DPDK on 4 host CPUs. Tested with UDP traffic on 2 x 10G ports.
  13. 13. OVS Fall conference 2017 LiquidIO OVS Offload - Openstack integration • Uses VF representors in host to allow Neutron server to bind LiquidIO VF to compute node VMs. • Uses relay agent to allow Neutron server to reach OVS control plane running on LiquidIO. • Integration bridge is implemented in the LiquidIO adapter itself. • Slow path continues to be within the LiquidIO but VF stats are updated for the VF representor in the hypervisor. • No changes to Neutron for this model. • Proof of concept completed for ODL & OVN with Pike based RDO.
  14. 14. OVS Fall conference 2017 LiquidIO OVS offload – pros & cons • Advantages § Slow path avoids PCI overhead. § Host isolation – vswitch can be remotely managed. § Migration to new OVS version without kernel or host OS changes. § Supports all tunneling protocol available with OVS – Vxlan, NVGRE, GENEVE. § Support for conntrack + NAT. • Limitations § VMs connect to the data network using a single adapter. § Openstack components lacks flexibility to support full offload. § Data plane requires tweaks to support new OVS features. § Live migration requires attach to VM using virtio. § PCI passthrough to VM cannot support Live Migration.
  15. 15. OVS Fall conference 2017 LiquidIO OVS Offload – looking ahead • Add support for OVS 2.8 • Infrastructure to support TC/Flower based offload • Support next generation ARM based LiquidIO adapters • Improve conntrackimplementation • Add support for ebpf offload • How can the community help with full offload? § Allow control and data plane to exist in different domains. Some support for TCP based connections but this could be fully extended. § OVN currently expects vswitch to run on the local processor.
  16. 16. OVS Fall conference 2017 LiquidIO OVS Offload Thank You!

×