Non-Hazardous for shipping water in oil testavailable where you see the EasySHIP logoEasySHIPOil Analysis SolutionsHigh Sp...
Make fast on-site maintenance decisions with Kittiwake’soil analysis solutions. An accurate range, providinglaboratory gra...
-5°C to +20°C DieselUser selectable: +25°C to + 0°C,+15°C to -10°C, +5°C to -18°C0.5 ml< 8 minutesMembrane type with tacti...
Fuel Oil Analysis EquipmentGain peace of mind and ensure your fuel delivery is thecorrect specification.Use Kittiwake fuel...
ConfigurationsApplicationMarine Fuel  LubeResidual Fuel DrivenEquipmentSteam Power PlantFuel and Lube Test Cabinet Configu...
Fuel and Lube Oil Analysis EquipmentKittiwake fuel and lubricating oil analysis equipment enables you tocarry out a simple...
Insolubles are a build up of combustion related debris andoxidation products within the oil.	Regular monitoring of insolub...
MA-K27468-KW Issue 9Kittiwake Developments Ltd3 - 6 Thorgate Road LittlehamptonWest Sussex BN17 7LUUnited KingdomTel: + 44...
Upcoming SlideShare
Loading in …5
×

Parker Kittiwake Oil Analysis Solutions

1,126 views

Published on

  • Be the first to comment

Parker Kittiwake Oil Analysis Solutions

  1. 1. Non-Hazardous for shipping water in oil testavailable where you see the EasySHIP logoEasySHIPOil Analysis SolutionsHigh Specification, Exact Results.Fuel and Lube Oil Analysis Made Easy.
  2. 2. Make fast on-site maintenance decisions with Kittiwake’soil analysis solutions. An accurate range, providinglaboratory grade oil condition results in minutes.On-site Oil Analysis LaboratoriesKittiwake supply two styles of On-site Oil Analysis Suite. Oil Test centres come inmetal or industrial roller cases for portability, while Fuel and Lube test cabinets aredesigned for wall mounting on-site. Of rugged design and suitable for long term usein harsh environments, the equipment is simple to use and ideal for operation bynon-technical personnel. Fast accurate results for multiple oil parameters. Make informed on-site maintenance decisions. Act before the onset of critical failure. Robust and reliable in harsh or remote environments.The Kittiwake oil analysis range provides a condition monitoring tool that enables youto make informed operational and maintenance decisions about your critical plant andequipment. Fuel and lubricating oils form a major cost element in the operation of almostall industrial machinery and engines; the quality must be closely monitored to protect theinvestment. The ability to test on-site, at the point of use, enables engineers and facilitiesmanagers to conduct oil analysis quickly and easily. Detecting out-of-spec fuels or lubricantscan identify potential problems before equipment damage occurs. Choose from a range ofequipment and parameters to use individually or combine into a single Oil Analysis Suite.Protect your assets, improve productivity & increaseuptime using regular on-site oil analysisStorage space for all consumablesand reagents within the cabinetensuring that all necessary equipmentis readily available and easy to findAll equipment is securely stored in arobust portable roller case, ideal for longterm use in harsh industrial environmentsTest cells for water in oil, insolublesand total base number (TBN), workin conjunction with the test console,via an electromagnetic link, eliminatingthe need for wires or batteriesThe Kittiwake Heated Viscometer and Test Console featureeasy to use touch pad keys for simple operation, with resultsclearly displayed on an LCD screensLike all Kittiwake equipment, theOil Test Centre is manufacturedunder strict ISO 9001:2000 qualitystandards, ensuring consistent andaccurate test resultsReplacement reagents and spareequipment, including a range of samplebottles and sampling equipment, areavailable from Kittiwake at short noticeNATO Approved Marine OTC case
  3. 3. -5°C to +20°C DieselUser selectable: +25°C to + 0°C,+15°C to -10°C, +5°C to -18°C0.5 ml< 8 minutesMembrane type with tactilebuttons124 x 64 graphics LCD withLED backlight100 - 250 VAC 50 / 60 HzFG-K12663-KW: Cloud Point Detector (Standard)FG-K16954-KW: Cloud Point Detector (Extended Range)Ordering InformationRange (standard):Range (extended):Sample size:Average test time:Keypad:Display:Power:When ambient temperature dropsbelow a certain level, wax crystals can form inthe oil. This temperature is the ‘cloud point’.Kittiwake’s Cloud Point Detector measuresthe temperature at which these wax crystalsform, helping to screen the oil and preventpotential problems such as blocked fuel filtersand lines.Cloud PointDetectorANALEX Machinery Condition InstrumentsThe ANALEXfdMplus is a highly accurateinstrument designed to measure the levelof ferrous wear debris in an oil or greasesample.Reporting in parts per million, the unit canbe used to measure ferrous wear debris inoil or grease in many sample vessels from avariety of machinery types.Cloud Point DetectorThe Kittiwake range of ANALEX wear debris analysis instruments, enable you to carry outsimple, on-site oil and machinery condition monitoring.Testing your oil for wear debris places you in complete control, enabling you to identifies weartrends and ensures expensive machinery and equipment failures are avoided. Problem equipmentcan be quickly identified, decreasing downtime, increasing productivity and profit.ANALEXfdMplus Ferrous Debris Meter50 ml Bottle 0 - 2500 ppm10 ml syringe 0 - 1900 ppm5 ml Syringe 0 - 34000 ppm5 ml Tube 0 - 28000 ppmGrease Pot 0 - 8000 ppm1 ppm or 2% of averagereading, (whichever is greater)< 1 minute to stabilise frompower on< 15 seconds per sample110 - 250 VAC auto-selected, 50 / 60 HzFG-K17144-KW: ANALEXfdMplusOrdering InformationMeasurement Range:ppmDisplay ResolutionTest Time:Power:Rapidly identify wear rates; before damage occurs.Sophisticated Reporting - results shown in tabular display and graphicaltrending by equipment number. Alarms levels can be set and resultsdownloaded to PC.Fully portable - robust and reliable in harsh or remote environments.Prevent wax crystals forming in the fuel, which can block filters and starve the engine.Particularly useful for any industry operating in climates with low ambient temperatures.Highly accurate, electronic instrument available in extended and standard temperature ranges.An automated closed cup instrumentusing a small sample size and 1 or 2minute standard test time.0 to 300°C1 to 99 minutes2 to 4 mlFG-K16909-KW: Electronic Flashpoint TesterOrdering InformationTemp Range:Test Time:Sample Size:The flammability of a material determines its safety classification and the regulations underwhich it must be handled, stored and transported. Can also be used to help detect fuel dilution.Note: A standard butane (lighter) refill cartridge is required for operation.Flash Point Tester
  4. 4. Fuel Oil Analysis EquipmentGain peace of mind and ensure your fuel delivery is thecorrect specification.Use Kittiwake fuel analysis equipment to check the key parameters of yourfuel oil delivery. Kittiwake’s rapid, independent and accurate fuel testingequipment confirms that your fuel oil is of acceptable quality and compatiblewith existing stocks.Range of equipment available to test for key parameters.Highly accurate, laboratory grade results available on-board or in the field.The Kittiwake Density Meter is suitable forboth distillate and residual fuel oils.Measuring the density of fuel usinghydrometers, the Density Meter can beused to confirm the quantity and gradeof fuel delivered.Density MeterEnsure stability and compatibility of fuel typesin minutes.The compatibility tester will quickly identifypotential fuel stability problems. It will alsorapidly determine if a fuel is compatible withexisting fuel stocks.CompatibilityTesterDensity MeterCompatibility TesterOrdering InformationCalculations: Density at 15°C in vacuo,Centipoise to centiStokes Calculated CarbonAromaticity Index (CCAI)The Density Meter is supplied complete withthree hydrometers and consumables. The DensityMeter is available standalone or as part of anOil Analysis Suite.FG-K1-300-KW: Density MeterOrdering InformationThe Compatibility Tester is supplied completewith test papers and consumables. Thecompatibility tester is available standalone oras part of an Oil Analysis Suite.FG-K1-500-KW: Compatibility TesterIdentify possible stability problems before mixing fuels, giving you peace of mind when accepting fuel deliveries.Prevent sludge deposits, failure of fuel handling systems and costly combustion related engine damage.Ensure the correct weight of fuel has been delivered.Density is calculated electronically, giving fast, accurate results and estimating the combustion performance (CCAI), and correct viscosity in cP to cSt.
  5. 5. ConfigurationsApplicationMarine Fuel LubeResidual Fuel DrivenEquipmentSteam Power PlantFuel and Lube Test Cabinet ConfigurationsTestWater in OilTest CellTBN Test CellInsolublesTest CellTAN Test CellDensityMeterCompatibilityMeterViscosity(heated)Viscosity(unheated)Salt/Fresh WaterPour PointRange0-2.5% (0-1.0% )0-6000 ppm0-3000 ppm0-99 mg/KOH0-3.5% w/w0-1.75%0-6 mg KOH TAN0-6 mg KOH TAN IP1390-3 mg KOH TAN IP177800-1010 kg/m3 at 15ºCTemp. selectable (50 or 70 ºC)As per ASTM D474020-810 cSt at 40 ºC, 50 ºC or 100 ºC15-500 cSt at 40 °C, 50 ºC or 100 ºCGo/no-go0-50 ºC fuel oils ISO 8217 grade RMA-RMKTest Time3 minutes10 minutes2.5 minutes1 minute2 minutes1 - 10minutes20 minutesunattended1 - 10minutes1 minute1 hour10 minutesAccuracy+/- 0.1%+/- 100 ppm+/- 50 ppm+/- 5%5 TBN + 1TBN+/-0.1 w/w+/-0.2 TAN+/- 0.1%Variation of 1 ratingin 20 repeat tests+/- 3 %(20 - 450 cSt)or +/- 2 cSt+/- 2% (15 - 320 cSt)or +/ - 2 cStPass / Fail+/- 6 ºCPower110 - 250 VAC110 - 250 VAC110 - 250 VAC110 - 250 VAC110 - 250 VAC110 - 250 VAC110 - 240 VAC110 to 250 VAC--CorrelationIP 386ASTM D4928IP 400IP 316Mobil Soot IndexIP 177 (ASTM D664)SAE ARP 5088(modified IP139,ASTM D974)ASTM D1298 /IP160ASTM D4740ASTM D445 /IP71ASTM D445 /IP71ASTM D97 / IP15ApplicationFuel / Lube OilsLube OilsLube OilsFuel / Lube OilsFuel OilsResidualFuel OilFuel / Lube OilsFuel / Lube OilsFuel / Lube OilsFuel OilsSpecificationsApplicationDiesel EnginesSteam turbines, gearboxes compressorsAviation lubes andhydraulicsOther configurationsavailableOil Test Centre Configurations (supplied in portable roller case)* EasySHIP Water in Oil range 0-1.0% - non EasySHIP version 0-2.5%For Oil Test centre configurations in portable roller case with non EasySHIP reagents - Part code FG-K1-120-KW-X(X)Oil Test centre configurations are also available in marine NATO approved metal case. Part code FG-K4-100-KW-X(X) for EasySHIP FG-K1-100-KW-X(X)for non EasySHIPOrder NumberFG-K1-400-KWFG-K1-600-KWFG-K1-602-KWDIGIWater/TBN Celln0-99 TBNCell0-2.5%Water Cell ConsolennFuelSamplerInsolublesCellECONnPourPointnDensityMeternnnCompatibilityMeterHeatedViscometernnnSaltTestnnnTAN 0-6CellnEasySHIP0-0.1%*0-2.5%Water Cellnnn0-6000 ppmWater Cellnnnnnnnn5-99TBN Cellnnnnnn0-6TAN Cellnnnn0-3TAN CellnnnnInsolublesTest CellnnnnnnnnUnheatedViscometernnnnnnHeatedViscometernnnnnnTestConsolennnnnnnnnnnnOrder NumberFG-K4-120-KW-AFG-K4-120-KW-AHFG-K4-120-KW-BFG-K4-120-KW-BHFG-K4-120-KW-CFG-K4-120-KW-CHFG-K4-120-KW-DFG-K4-120-KW-DHFG-K4-120-KW-EFG-K4-120-KW-EHFG-K4-120-KW-FFG-K4-120-KW-FHEasySHIP
  6. 6. Fuel and Lube Oil Analysis EquipmentKittiwake fuel and lubricating oil analysis equipment enables you tocarry out a simple on-site condition based maintenance of your fuel andlubricating oils. Regular monitoring to provide trends, helps to avoid expensive machinery and equipment failure. Laboratory grade results, available on-board or in the field, instantly. Save time and money by knowing exactly when to change out oil.ConsoleThe console is the central control unitfor the Oil Analysis range.A unique inductive coupled power supplyenables individual test cells to be poweredvia an electromagnetic link, thus eliminatingthe need for wires, batteries or connectors.An infra-red data link connects the Unheated Viscometer to the side of theConsole. Measurement data is transmitted via the link and up to 256 sets ofreadings can be stored in the memory. Results are displayed on an easy to readLCD screen and can be downloaded to a PC for further analysis and trending.The console features large key pad buttons for simple operation.Console8 digit LEDMembrane type with tactilebuttonsMeasuring Cell socket withinductive power circuit and InfraRed data link. Infrared data linkfor viscometer. RS232 port fordata down load to PC.Capacity to store 256 readingsin non volatile storage110 to 240 AC 50/60 Hz 20 VADisplay:Keypad:Interfaces:Memory:Power:SpecificationsThe TBN of oil is the measure of the alkaline reserve, which is the ability of the oilto neutralise acids formed during the combustion process.By determining the reference value of the new oil, the used oil TBN can be calculated. Avoid fouling within the engine and corrosion of engine components by monitoring the Total Base Number (TBN) of lubricating oils.Water can enter the oil from many sourcesincluding condensation, leakage andmalfunction of oil treatment systems. Prevent corrosion and cavitation ofmachinery by detecting water in oil,before any damage occurs. Minimise instability of additive packagesand damaging microbe growth bymonitoring your oil. Two types of water in oil test cells areavailable, measuring 0-2.5 % range and 0-6000 ppm or 0-3000 ppm range.Easyship water in oil range 0-1%Water in OilFG-K25340-KW: Water in Oil 0-6000 ppm Test KitFG-K25195-KW: Water in Oil 0-2.5 % Test KitOrdering InformationNato Stock No: 6630-99-024-7089Test CellsTest Kits contain Water in Oil Test Cell, ElectronicConsole and all reagents / consumables in aportable, robust metal case. Test Cells are alsoavailable as part of an Oil Analysis Suite.Avoid costlymachinebreakdownswith regularoil testingTotal Base Number (TBN)FG-K25197-KW: TBN Test KitOrdering InformationNato Stock No: 6630-99-702-4865Test Kit contains TBN Test Cell, Electronic Consoleand all reagents / consumables in a portable, robustmetal case. The TBN Test Cell is also available aspart of an Oil Analysis Suite.FG-K17767-KW Water in oil 0-6000ppmFG-K17766-KW Water in oil 0-1%EasySHIPEasySHIPEasySHIP
  7. 7. Insolubles are a build up of combustion related debris andoxidation products within the oil. Regular monitoring of insolubles helps to prevent lacquer formation on hotsurfaces, sticking of piston rings and wear of cylinder liner and bearing surfaces. Highly accurate results - two test modes are available; % insolubles w/w byIP316 or % insolubles by Mobil Soot Index. InsolublesTest CellTotal Acid Number or TAN is a measure of both the weak organic and stronginorganic acids present within oil. Prevent damage from oil oxidation by monitoring TAN levels. Highly accurate test results with seperate reagent packs for 0-3 and 0-6 TAN.Viscosity is regarded an oils most important characteristic. It is theviscosity that shows the oil’s resistance to flow and the strength of the oilfilm between surfaces.Viscosity can increase or decrease as a result of problems such as contamination,fuel dilution and shear thinning. Measurement of viscosity is extremelyimportant for hydraulic oils, diesel engine oils, gears and fuel oils.Heated ViscometerUnheatedViscometerInsolublesFG-K25194-KW: Insolubles Test KitOrdering InformationNato Stock No: 6630-99-811-8517Test Kit contains Insolubles Test Cell, ElectronicConsole and all reagents / consumables in a portable,robust metal case. The Insolubles Test Cell is alsoavailable as part of an Oil Analysis Suite.Total Acid Number (TAN)FG-K25196-KW: Total Acid Number (TAN) Test KitOrdering InformationTest Kit contains TAN Test Cell, Electronic Consoleand all reagents / consumables in a portable, robustmetal case. The TAN Test Cell is also available aspart of an Oil Testing Suite.Ordering InformationFG-K1-200-KW: Heated ViscometerUnheated ViscometerTwo types of Viscometer are available fromKittiwake - Heated and Unheated. Theheated viscometer measures at the actualtemperature required while the unheatedviscometer measures at room temperatureand then automatically corrects to thereported temperature.Both instruments are designed to ‘Tilt’ fromside to side in both directions, allowing theball to fall under gravity and the viscosity ofthe oil calculated automatically. Monitoring viscosity gives an early warning for a range of common problems. Highly accurate results with two readings are available at 40°C, 50°C or 100°C. Calculate the SAE range, as well as viscosity (unheated viscometer). Test an even greater range of oils, by changing the viscosity index or density. Estimate the combustion performance (CCAI) of fuel oil. Heavy duty, robust equipment - ideal for long term use with rapid results. Calculated Viscosity at 40 °C, 50°Cand 100 °C, Calculated CarbonAromaticity Index (CCAI).8 Digit LEDMembrane type with tactilebuttons110 to 240 AC 50/60 HzRange:Display:Keypad:Power:Test Kit contains Heated Viscometer, powersupply and all consumables in a portable robustmetal case.20-500 cSt Calculated Viscosityat 40 °C, 50°C and 100 °C.Calculated SAE RangeRange:* Unheated Viscometer available as part of Oil Analysis Suite onlyViscosity
  8. 8. MA-K27468-KW Issue 9Kittiwake Developments Ltd3 - 6 Thorgate Road LittlehamptonWest Sussex BN17 7LUUnited KingdomTel: + 44 1903 731 470Email: sales@kittiwake.comWeb: www.kittiwake.com

×