Energy Modeling and Analysis Services - Case Study

1,395 views

Published on

Hi-Tech provides building energy modeling and analysis services. Check the key points of our services below.

1) To qualify the building for EPACT Certification using eQuest.
2) Interior, Exterior & Day Lighting reports for existing & proposed design.
3) Review of existing buildings, HVAC systems, lighting etc. & possibly save up to 60% in the proposed design, better than the Code.
4) Comparison of existing & proposed systems with respect to the Baseline Appendix-G ASHRAE 90.1.
5) Technical assistance to reduce energy consumption as per international standards (i.e. ASHRAE 90.1), local authority regulation & as per client’s requirements.
6) Software Used for Energy Modeling : eQuest 3.64, DiaLux, COMcheck & AutoCAD.

For any queries please email us at info@hitechcaddservices.com

Published in: Design
0 Comments
2 Likes
Statistics
Notes
  • Be the first to comment

No Downloads
Views
Total views
1,395
On SlideShare
0
From Embeds
0
Number of Embeds
2
Actions
Shares
0
Downloads
90
Comments
0
Likes
2
Embeds 0
No embeds

No notes for slide

Energy Modeling and Analysis Services - Case Study

  1. 1. ENGINEERING SERVICES Energy Modeling & Analysis
  2. 2. Hi-Tech Offerings Architectural Structural MEP SERVICES Mechanica BIM l CAE Electrica l
  3. 3. Hi-Tech Clientele – Worldwide Hi-Tech is a leading engineering services company for architectural, structural, civil, mechanical and electrical design, drafting, modeling and animation. INTERNATIONAL DOMESTIC
  4. 4. Energy Modeling & Analysis Services • Hi-Tech provides Energy Modeling / Simulation & Analysis services. • To qualify the building for EPACT Certification using eQuest. • Interior, Exterior & Day Lighting reports for existing & proposed design. • Review of existing buildings, HVAC systems, lighting etc. & possibly save up to 60% in the proposed design, better than the Code. • Comparison of existing & proposed systems with respect to the Baseline Appendix-G ASHRAE 90.1. • Technical assistance to reduce energy consumption as per international standards (i.e. ASHRAE 90.1), local authority regulation & as per client’s requirements. • Software Used for Energy Modeling : eQuest 3.64, DiaLux, COMcheck & AutoCAD. SERVICES Energy Analysis Light Pollution Analysis Fenestration Analysis Reflection & Glare Analysis Solar Insolation Analysis Shadow Analysis Day Light Analysis Visibility Analysis Location Analysis Acoustic Analysis
  5. 5. Energy Modeling Projects Artificial Lighting Modeling & Simulation Client Lighting Company in UK Scope of Work Energy Modeling, Analysis for efficient artificial lighting Inputs 2D Drawings in PDF format. Details of Luminaries and fixtures Output 3D Model Energy Simulation and Analysis Energy Consumption Data The above mentioned modeling, analysis were done based on the electrical design and data provided by the client. The fixtures and luminaries were selected as per client’s suggestion Software Relux | Team 02 | Duration 03 Days
  6. 6. Energy Modeling Projects Natural Day Lighting Modeling & Analysis of Daylight Factor and Lux Levels Client An Architect Firm in United States Scope of Work Energy Modeling, Analysis for calculating the natural day light available in the classroom of the school building. The analysis was done at two times of day and three times of the year Inputs 2D Drawings in PDF format. Details of Building Envelope and Material Output 3D Model Energy Simulation and Analysis. Of Daylight available The above mentioned modeling, analysis were done based on the geographical location, design data provided by the client Software Ecotect | Team 01 | Duration 12 Days
  7. 7. Energy Modeling Projects Shadow Analysis for the Buildings Client A Property Development Company in Australia Scope of Work Creating the 3D model using BIM software and calculating the shadow path based on the geographical situation of the building and the sun path Inputs 2D Drawings in PDF format. Geographical location Output 3D Model Animation of shadow path during the particular time of the day Software Revit | Team 01 | Duration 01 Day
  8. 8. Energy Modeling inDepartmental Store eQuest 3.64 Project Type: Departmental Store in USA Scope of Work: 1. To compare Baseline building as per ASHRAE 90.1 Appendix G to Proposed Building & Existing building performance. 2. To Propose efficient HVAC systems for Proposed design 3. To qualify Building for EPACT certification Inputs 1. Existing & proposed CAD Civil, Mechanical & Electrical layouts 2. Comchech Report comparing lighting. 3. Building Usage Information 4. Existing building Utility Bills Output 1. Monthly & Annual Energy Consumption by End use 2. Monthly Utility Bills 3. Monthly & annual Peak demand by End use 4. Monthly Electric Peak Day load Profiles Software eQuest 3.64 | Team 1 | Duration 5 Days
  9. 9. Lighting AnalysisDepartmental Store Project Type: Departmental Store in USA Inputs Site Photos. PDF of Tentative Architectural Layout of Interior & Exterior. Output Tentative CAD Architectural Layout. Foot Candle Analysis of Existing Interior & Exterior Lighting Design. CAD Layout of Existing Lighting Design. Compliance Report of Existing Lighting System i.e. As per ASHARE 90.1, IECC etc. Foot Candle Analysis of Proposed Interior & Exterior Lighting Design. CAD Layout of Proposed Lighting Design. Compliance Report of Proposed Lighting System i.e. As per ASHARE 90.1, IECC etc. Software DiaLux & ComCheck | Team 1 | Duration 5 Days
  10. 10. Energy Modeling inDining Facility eQuest 3.64 Project Type: Dining Facility in USA Scope of Work: 1. To compare Baseline building as per ASHRAE 90.1 Appendix G to Proposed Building & Existing building performance. 2. To Propose efficient HVAC systems for Proposed design 3. To qualify Building for EPACT certification Inputs 1. Existing & proposed CAD Civil, Mechanical & Electrical layouts 2. Comchech Report comparing lighting. 3. Building Usage Information 4. Existing building Utility Bills Output 1. Monthly & Annual Energy Consumption by End use 2. Monthly Utility Bills 3. Monthly & annual Peak demand by End use 4. Monthly Electric Peak Day load Profiles Software eQuest 3.64 | Team 1 | Duration 5 Days
  11. 11. Lighting AnalysisDining Facility Project Type: Dining Facility in USA Inputs Architectural Layout. Existing Lighting PDF Layout. Output Foot Candle Analysis of Existing Interior Lighting Design. CAD Layout of Existing Lighting Design. Compliance Report of Existing Lighting System i.e. As per ASHARE 90.1, IECC etc. Foot Candle Analysis of Proposed Interior Lighting Design. CAD Layout of Proposed Lighting Design. Compliance Report of Proposed Lighting System i.e. As per ASHARE 90.1, IECC etc. Software DiaLux & ComCheck | Team 1 | Duration 5 Days
  12. 12. Lighting AnalysisDining Facility Project Type: Dining Facility in USA Inputs Site Location. Door & Window Schedule. Output Day Light Calculation. Software DiaLux & ComCheck | Team 1 | Duration 5 Days
  13. 13. Energy Modeling inDining Facility eQuest 3.64 Project Type: Dining Facility in USA Scope of Work: 1. To compare Baseline building as per ASHRAE 90.1 Appendix G to Proposed Building & Existing building performance. 2. To Propose efficient HVAC systems for Proposed design 3. To qualify Building for EPACT certification Inputs 1. Existing & proposed CAD Civil, Mechanical & Electrical layouts 2. Comchech Report comparing lighting. 3. Building Usage Information 4. Existing building Utility Bills Output 1. Monthly & Annual Energy Consumption by End use 2. Monthly Utility Bills 3. Monthly & annual Peak demand by End use 4. Monthly Electric Peak Day load Profiles Software eQuest 3.64 | Team 1 | Duration 5 Days
  14. 14. Lighting AnalysisDining Facility Project Type: Dining Facility in USA Inputs Architectural Layout. Existing Lighting PDF Layout. Output Foot Candle Analysis of Existing Interior Lighting Design. CAD Layout of Existing Lighting Design. Compliance Report of Existing Lighting System i.e. As per ASHARE 90.1, IECC etc. Foot Candle Analysis of Proposed Interior Lighting Design. CAD Layout of Proposed Lighting Design. Compliance Report of Existing Lighting System i.e. As per ASHARE 90.1, IECC etc. Software DiaLux & ComCheck | Team 1 | Duration 5 Days
  15. 15. Lighting AnalysisDining Facility Project Type: Dining Facility in USA Inputs Site Location. Door & Window Schedule. Output Day Light Calculation. Software DiaLux | Team 1 | Duration 2 Days
  16. 16. Energy Modeling inCommercial Building eQuest 3.64 Project Type: Commercial building in USA Scope of Work: 1. To compare Baseline building as per ASHRAE 90.1 Appendix G to Proposed Building & Existing building performance. 2. To Propose efficient HVAC systems for Proposed design 3. To qualify Building for EPACT certification Inputs 1. Existing & proposed CAD Civil, Mechanical & Electrical layouts 2. Comchech Report comparing lighting. 3. Building Usage Information 4. Existing building Utility Bills Output 1. Monthly & Annual Energy Consumption by End use 2. Monthly Utility Bills 3. Monthly & annual Peak demand by End use 4. Monthly Electric Peak Day load Profiles Software eQuest 3.64 | Team 1 | Duration 5 Days
  17. 17. Lighting AnalysisCommercial Building Project Type: Commercial Building in USA Inputs Architectural Layout. Existing Lighting PDF Layout. Output Foot Candle Analysis of Existing Interior Lighting Design. CAD Layout of Existing Lighting Design. Compliance Report of Existing Lighting System i.e. As per ASHARE 90.1, IECC etc. Foot Candle Analysis of Proposed Interior Lighting Design. CAD Layout of Proposed Lighting Design. Compliance Report of Existing Lighting System i.e. As per ASHARE 90.1, IECC etc. Software DiaLux & ComCheck | Team 1 | Duration 5 Days
  18. 18. Lighting AnalysisCommercial Building Project Type: Commercial Building in USA Inputs Site Location. Door & Window Schedule. Output Day Light Calculation. Software DiaLux | Team 1 | Duration 2 Days
  19. 19. Energy Modeling inOffice Building eQuest 3.64 Project Type: Office Building in USA Scope of Work: 1. To compare Baseline building as per ASHRAE 90.1 Appendix G to Proposed Building & Existing building performance. 2. To Propose efficient HVAC systems for Proposed design 3. To qualify Building for EPACT certification Inputs 1. Existing & Proposed CAD Civil, Mechanical & Electrical layouts 2. Comchech Report comparing lighting 3. Building Usage Information 4. Existing building Utility Bills Output 1. Monthly & Annual Energy Consumption by End use 2. Monthly Utility Bills 3. Monthly & annual Peak demand by End use 4. Monthly Electric Peak Day load Profiles Software eQuest 3.64 | Team 1 | Duration 5 Days
  20. 20. Energy Modeling inWarehouse Building eQuest 3.64 Project Type : Warehouse building in USA Scope of Work: 1. To compare Baseline building as per ASHRAE 90.1 Appendix G to Proposed Building & Existing building performance. 2. To Propose efficient HVAC systems for Proposed design 3. To qualify Building for EPACT certification Inputs 1. Existing & Proposed CAD Civil, Mechanical & Electrical layouts 2. Comchech Report comparing lighting. 3. Building Usage Information 4. Existing building Utility Bills Output 1. Monthly & Annual Energy Consumption by End use 2. Monthly Utility Bills 3. Monthly & annual Peak demand by End use 4. Monthly Electric Peak Day load Profiles Software eQuest 3.64 | Team 1 | Duration 5 Days
  21. 21. Energy Modeling inIndustrial Building eQuest 3.64 Project Type : Industrial Building in USA Scope of Work: 1. To compare Baseline building as per ASHRAE 90.1 Appendix G to Proposed Building & Existing building performance. 2. To Propose efficient HVAC systems for Proposed design 3. To qualify Building for EPACT certification Inputs 1. Existing & Proposed CAD Civil, Mechanical & Electrical layouts 2. Comchech Report comparing lighting. 3. Building Usage Information 4. Existing building Utility Bills Output 1. Monthly & Annual Energy Consumption by End use 2. Monthly Utility Bills 3. Monthly & annual Peak demand by End use 4. Monthly Electric Peak Day load Profiles Software eQuest 3.64 | Team 1 | Duration 5 Days
  22. 22. Contact usEngineering(Sales & Marketing Division)Email: info@hitechcaddservices.comPhone: +91 79 4000 3252Board: +91 79 4000 3000Fax: +91 79 4000 3202Website: www.hitechcaddservices.com

×