Successfully reported this slideshow.
We use your LinkedIn profile and activity data to personalize ads and to show you more relevant ads. You can change your ad preferences anytime.
Mycotoxin Affinity Column




                  Antibody Bound Resin
Monoclonal
          Antibody



Support
 Bead
Mycotoxins
             Impurities
Mycotoxins bound to
monoclonal antibodies

                  Impurities
Column Wash
Mycotoxins bound to
monoclonal antibodies
Methanol elution
Purified mycotoxins in
        methanol




Methanol
                 Mycotoxins
AflaTest

• Limit of detection as low as 0.5 ppb
  (fluorometer) 0.05 ppb (HPLC)
• Wide range as high as 320 ppb
• AOAC Of...
FumoniTest
• 0.25 ppm (fluorometer) 0.016 ppm (HPLC)
  limit of detection
• Wide range of 0-10 ppm
• Excellent linearity: ...
ZearalaTest
• 0.10 ppm (fluorometer) 0.0025 ppm
  (HPLC) limit of detection
• Wide range of 0-5 ppm
• Excellent linearity ...
OchraTest
• Limit of detection as low as 1 ppb
  (fluorometer) 0.25 ppb (HPLC)
• Wide range as high as 100 ppb
• Excellent...
DON FQ
   Quick - Results in less than 30 minutes (after
    sample extraction.
   Sensitive - Detects levels as low as ...
DONtest HPLC
• limit of detection : 0.1 ppm (HPLC)
• Wide range : 0 -10 ppm
• Excellent linearity with correlation coeffic...
T-2
   Quick - Results in less than 20 minutes (after
    sample extraction.
   Sensitive - Detects levels as low as 0.1...
T-2 HPLC
• limit of detection : 0.005 ppm
• Wide range : 0 –1.5 ppm
• Excellent linearity with correlation coefficient (r)...
Solely Distribute by :
Team Medical & Scientific Sdn. Bhd.
41, Jalan Anggerik Vanilla T31/T, Kota Kemuning,
40460 Shah Ala...
Vicam Ia Working Principle
Upcoming SlideShare
Loading in …5
×

Vicam Ia Working Principle

1,013 views

Published on

Published in: Technology, Business
  • Be the first to comment

  • Be the first to like this

Vicam Ia Working Principle

  1. 1. Mycotoxin Affinity Column Antibody Bound Resin
  2. 2. Monoclonal Antibody Support Bead
  3. 3. Mycotoxins Impurities
  4. 4. Mycotoxins bound to monoclonal antibodies Impurities
  5. 5. Column Wash
  6. 6. Mycotoxins bound to monoclonal antibodies
  7. 7. Methanol elution
  8. 8. Purified mycotoxins in methanol Methanol Mycotoxins
  9. 9. AflaTest • Limit of detection as low as 0.5 ppb (fluorometer) 0.05 ppb (HPLC) • Wide range as high as 320 ppb • AOAC Official Method status • USDA-FGIS Certificate of Conformance
  10. 10. FumoniTest • 0.25 ppm (fluorometer) 0.016 ppm (HPLC) limit of detection • Wide range of 0-10 ppm • Excellent linearity: r = 0.998 • Excellent precision: %CV < 11% from 1-10 ppm • Fluorometer method correlates well with HPLC linear regression r = 0.995 • USDA-FGIS Certificate of Conformance
  11. 11. ZearalaTest • 0.10 ppm (fluorometer) 0.0025 ppm (HPLC) limit of detection • Wide range of 0-5 ppm • Excellent linearity r = 0.999 • Excellent precision: %CV = 13% over the assay range • Fluorometer method correlates well with HPLC linear regression r = 0.990
  12. 12. OchraTest • Limit of detection as low as 1 ppb (fluorometer) 0.25 ppb (HPLC) • Wide range as high as 100 ppb • Excellent linearity with correlation coefficient (r) of 0.997-0.999 for wheat, dried fruit and green coffee • Excellent precision with %CV <10% at 20 ppb • Fluorometer method correlates well with HPLC when analyzed by linear regression
  13. 13. DON FQ  Quick - Results in less than 30 minutes (after sample extraction.  Sensitive - Detects levels as low as 0.5 ppm  Wide Range - Measures up to 5 ppm  Convenient - Uses same instrumentation as other VICAM mycotoxin tests  USDA-FGIS Certificate of Conformance
  14. 14. DONtest HPLC • limit of detection : 0.1 ppm (HPLC) • Wide range : 0 -10 ppm • Excellent linearity with correlation coefficient (r) of 0.999 : r2= 0.999 • Excellent precision : with %CV 8.3% • DONtest-HPLC method correlates well with GC- ECD when analyzed by linear regression: r2 = 0.982
  15. 15. T-2  Quick - Results in less than 20 minutes (after sample extraction.  Sensitive - Detects levels as low as 0.15 ppm  Wide Range - Measures up to 2.0 ppm  Convenient - Uses same instrumentation as other VICAM mycotoxin tests  Safe - Requires less toxic materials than other methods.
  16. 16. T-2 HPLC • limit of detection : 0.005 ppm • Wide range : 0 –1.5 ppm • Excellent linearity with correlation coefficient (r) of 0.999 : r2= 0.999 • Excellent precision : RSD 3.68%
  17. 17. Solely Distribute by : Team Medical & Scientific Sdn. Bhd. 41, Jalan Anggerik Vanilla T31/T, Kota Kemuning, 40460 Shah Alam, Selangor Tel : 603-5122 5108 Fax : 603-5122 1608 Email : info@tms-lab.com Blog : tms-lab.blogspot.com

×