Vicam Ia Working Principle

  1. 1. Antibody Bound Resin Mycotoxin Affinity Column
  2. 2. Support Bead Monoclonal Antibody
  3. 3. Impurities Mycotoxins
  4. 4. Impurities Mycotoxins bound to monoclonal antibodies
  5. 5. Column Wash
  6. 6. Mycotoxins bound to monoclonal antibodies
  7. 7. Methanol elution
  8. 8. Methanol Mycotoxins Purified mycotoxins in methanol
  9. 9. AflaTest • Limit of detection as low as 0.5 ppb (fluorometer) 0.05 ppb (HPLC) • Wide range as high as 320 ppb • AOAC Official Method status • USDA-FGIS Certificate of Conformance
  10. 10. FumoniTest • 0.25 ppm (fluorometer) 0.016 ppm (HPLC) limit of detection • Wide range of 0-10 ppm • Excellent linearity: r = 0.998 • Excellent precision: %CV < 11% from 1-10 ppm • Fluorometer method correlates well with HPLC linear regression r = 0.995 • USDA-FGIS Certificate of Conformance
  11. 11. ZearalaTest • 0.10 ppm (fluorometer) 0.0025 ppm (HPLC) limit of detection • Wide range of 0-5 ppm • Excellent linearity r = 0.999 • Excellent precision: %CV = 13% over the assay range • Fluorometer method correlates well with HPLC linear regression r = 0.990
  12. 12. OchraTest • Limit of detection as low as 1 ppb (fluorometer) 0.25 ppb (HPLC) • Wide range as high as 100 ppb • Excellent linearity with correlation coefficient (r) of 0.997-0.999 for wheat, dried fruit and green coffee • Excellent precision with %CV <10% at 20 ppb • Fluorometer method correlates well with HPLC when analyzed by linear regression
  13. 13. DON FQ  Quick - Results in less than 30 minutes (after sample extraction.  Sensitive - Detects levels as low as 0.5 ppm  Wide Range - Measures up to 5 ppm  Convenient - Uses same instrumentation as other VICAM mycotoxin tests  USDA-FGIS Certificate of Conformance
  14. 14. DONtest HPLC • limit of detection : 0.1 ppm (HPLC) • Wide range : 0 -10 ppm • Excellent linearity with correlation coefficient (r) of 0.999 : r2 = 0.999 • Excellent precision : with %CV 8.3% • DONtest-HPLC method correlates well with GC- ECD when analyzed by linear regression: r2 = 0.982
  15. 15. T-2  Quick - Results in less than 20 minutes (after sample extraction.  Sensitive - Detects levels as low as 0.15 ppm  Wide Range - Measures up to 2.0 ppm  Convenient - Uses same instrumentation as other VICAM mycotoxin tests  Safe - Requires less toxic materials than other methods.
  16. 16. T-2 HPLC • limit of detection : 0.005 ppm • Wide range : 0 –1.5 ppm • Excellent linearity with correlation coefficient (r) of 0.999 : r2 = 0.999 • Excellent precision : RSD 3.68%
  17. 17. Team Medical & Scientific Sdn. Bhd. 41, Jalan Anggerik Vanilla T31/T, Kota Kemuning, 40460 Shah Alam, Selangor Tel : 603-5122 5108 Fax : 603-5122 1608 Email : info@tms-lab.com Blog : tms-lab.blogspot.com Solely Distribute by :

×