Motor Starters

MOTOR ON

TM

rs

Motor Starte

TM

rs

Motor Starte

Safe Guard for Motor
Oil immersed Starters | Control...
TM

Oil Immersed Starter
l
l

l
l

l

l
l

Oil immersed Direct On-Line Starters ranging from 3 HP to 10 HP
Oil immersed Di...
TM

Air Break Direct On Line Starter & Star Delta Starter
l

l

l

l
l

l
l

l

Air Break Direct Online Starter ranging fr...
AIR BREAK / OIL IMMERSED STARTERS - INSTRUCTIONS
l

l

As given in selection table starter relay ranges are for surface mo...
Upcoming SlideShare
Loading in …5
×

Mag Switch Gears, Coimbatore, Switch Gear Equipment

1,332 views

Published on

Suppliers of Air Break Single Phase Starter, Air Break Direct on Line Starter, Air Break Star Delta Semi Automatic, Air Break Star Delta Automatic.

Published in: Business, Technology
  • Be the first to comment

  • Be the first to like this

Mag Switch Gears, Coimbatore, Switch Gear Equipment

  1. 1. Motor Starters MOTOR ON TM rs Motor Starte TM rs Motor Starte Safe Guard for Motor Oil immersed Starters | Control Panels | Air Break Starters | Single Phase Starters Suitable for A.C. induction motors & Pumpsets used in Agriculture, Industry & Household
  2. 2. TM Oil Immersed Starter l l l l l l l Oil immersed Direct On-Line Starters ranging from 3 HP to 10 HP Oil immersed Direct On-Line Starters (Heavy Type) OBHD series ranging from 10 HP to 20 HP Oil immersed Hand operated Star Delta Starter ranging from 5 HP to 35 HP Motor Starters Oil immersed Starter Direct on-line with magnetic / Thermal over load relay Contacts made of electrolytic copper material with double break system ensure long life and better conductivity of contacts. No Volt coil, Tripping coils and Contacts are immersed in oil which absorbs sparking of contacts and coil temperature. No Volt coils are designed to withstand wide voltage fluctuations. The magnetic type over load release with adjustable oil dash pot time lag device works on the principle of current and not dependent on the temperature, it enables fine adjustment of the setting even to a fraction of an Ampere, thus eliminating the use of single phase preventor. Range 3.0 HP - 20.0 HP Instructions Before energizing, remove packing materials and tag along with cotton tape from guides. Fill in the tank with good quality transformers oil up to the level mark before energizing (2.25 litres for DOL, 3.25 for HDOL, and 4.25 litres for SD). Oil must be checked periodically and change oil for better life. To start the motor press and hold the green colour push button for at least 5 to 10 seconds for proper functioning in the case of D.O.L starter. In the Star Delta Starters, bring the handle to “Star” position, then press and hold green colour push button until the motor gets energized and shift the handle to “Delta” position. it is not possible to put the handle into “Delta” position without going through “Star” position. Oil immersed Star Delta Starter Semi Automatic / Automatic The starter is consisting of three contactors. In the semi automatic starter, the time delay extends over the period when the start button is kept pressed. The changeover from star to delta takes place at the instant when the start button is released. In the automatic starter, delay timer is provided. It changes from star to delta automatically in the preset time. OIL IMMERSED STARTER SELECTION TABLE Motor Rating Three Phase 415 V Motor Full Load Current (approx) Amps Starter Relay Range D.O.L Star Delta (Amps) Amps Oil immersed Starter Star-Delta with magnetic over load relay Range 7.5 HP - 35 HP Oil immersed Starter Semi Automatic / Automatic with Thermal overload relay Range 7.5 HP - 40 HP Back-up Fuse Rating Maximum - D.O.L Back-up Fuse Rating Maximum - Star Delta SDFA SWG HRC Fuses (Rewireable) HRC Fuses SWG (Rewireable) 21 16A 26 19 20A 25 50A 19 20A 25 50A 19 25A 23 13 - 21 63A 19 32A 22 20 - 32 80A 17 35A 21 20 - 32 50A 19 28 - 44 63A 19 30 - 50 80A 17 HP Kw 3 2.2 5 4-9 20A 25 5 3.7 7.5 8 - 12 8 - 12 6 - 10 35A 7.5 5.5 11 12 - 16 12 - 16 6 - 10 50A 10 7.5 14 15 - 23 15 - 23 9 - 15 12.5 9.3 18 18 - 28 18 - 28 9 - 15 15 11 20 22 - 34 22 - 34 20 15 28 30 - 45 30 - 45 25 18.5 35 38 - 45 30 22 40 45 - 65 40 30 60
  3. 3. TM Air Break Direct On Line Starter & Star Delta Starter l l l l l l l l Air Break Direct Online Starter ranging from 1 HP to 10 HP (3 Phase) can be convertable to single phase also. Air Break Semi Automatic and automatic Star Delta ranging from 5 HP to 15 HP Motor Starters Air Break Starter Direct On - Line Air Break Starter Star - Delta Semi Automatic/ Automatic Contact tips made of thick AgCdo material to withstand extreme field conditions. No Volt coils are designed to withstand wide voltage fluctuations. Bimetal Thermal overload relays are calibrated as per IS standards will trip off accurately during overload and in phase failure conditions. A latch is provided to prevent accidental starting. Air break starters are suitable for variable load condition motors with external panel operations such as limit switch and other electronic controls. Range 1.0 HP - 10 HP Range 5 HP - 15 HP Air Break Starter Direct On - Line Single Phase Housed in an attractively powder coated steel enclosure. Air Break single phase Motor Starter have bimetal overload auto reset type relay which provides complete protection to single phase motor. Two pole contactor with No volt coil protects from voltage variation. Control Panels l l l Control Panels are suitable for borewell and openwell submersible pumps. Single Phase panel with overload auto reset relay and contactor provides complete protection to single phase motor. Range 0.5 HP - 3.0 HP Control Panel (Single Phase) Three phase control panel are provided with Auto Start and single phase preventer ( It Auto Starts the motor in 3 phase and Auto Stops in 2 phase ) Control Panel (Three Phase) TM Motor Starters TM Motor AIR BREAK STARTER SELECTION TABLE Motor Rating (DOL) Three Phase 415 V Single Phase 220v Starter Relay Range Range : 0.5 HP - 3 HP HP KW Starter Relay Range 1 .75 2 Motor Rating ( Star Delta) Three Phase 415 V Starter Relay Range Starters Range : 3 HP - 10 HP Backup Fuse Rating Maximum 0.5 KW 0.37 4 - 6.5 HRC SWG Rewireable Switches 1.5 - 2.5 16A 25 1.5 2.5 - 4 25A 23 3 HP 2.2 4 - 6.5 5 3.7 4 - 6.5 25A 23 HP KW 1 0.75 6 - 10 5 3.7 6 - 10 7.5 5.5 6 - 10 32A 21 1.5 1.10 9 - 14 7.5 5.5 9 - 14 10 7.5 9 - 14 32A 21 2 1.50 10 - 16 12.5 9.3 11 - 18 32A 21 3 2.20 13 - 21 15 11 13 - 21 35A 21 10 7.5 13-21
  4. 4. AIR BREAK / OIL IMMERSED STARTERS - INSTRUCTIONS l l As given in selection table starter relay ranges are for surface motors. The next higher relay range must be selected in case of submersible motors where the full load current is higher than the surface motor. While placing order please specify motor HP, Voltage, Full load current rating and coil voltage. l In case of high torque motors, special model starters can be supplied on request. l The local electrical codes and regulations must be followed for installation. l Air Break Starter must be mounted vertically upright l l l l l l Starter must be protected from rain and direct sunlight. It must have good air circulation and be away from high temperature locations. Starter location should be easily accessible for regular inspection and be relatively free from dust, fumes and moisture. Starters must be selected with suitable relay range as per motor rating shown in the selection table. Turn the current adjustment knobs to set full load current of motor mentioned in the motor name plate. Check screws for tightness and give proper earthing to avoid shocks. Starters must never be used without backup fuses. HRC fuses are preferable for protecting the installation as well as the relay of the starter against short circuits. For reverse rotation of motors, interchange any two supply lines. Pilot circuit fuses must be used incase of remote control operation to protect pilot wiring, which is not adequately protected by the backup fuses. l There should not be any loose connections in incoming and outgoing terminal. l Please refer operator’s manual supplied along with starter for wiring diagram. l The ambient temperature should not exceed 40 0C USE OMAX GENUINE SPARES FOR LONG LIFE AND BETTER PERFORMANCE PRAVIN ENGINEERING TM Motor Starters Site No. E-1, Vasantha Nagar Street No-6, Behind E-B Office, Singanallur, Coimbatore - 641 005.Tamilnadu, INDIA Phone : 91-422 - 2272419, 3253253 Mobile : 93622 06195 E - mail : omaxstarters@gmail.com Web : www.omaxstarters.com www.omaxstarters.com

×