(https://www.servostabiliser.com/) Established in the year 2007, we, “Beta Power Controls”, are a leading manufacturer of Isolation Transformer, Automatic Voltage Controller and Servo Stabilizer. The offered range of product includes Servo Stabilizer, AC Voltage Regulator, Isolation Transformer and many more to name in the catalog. The products manufactured by us have made a distinct place in the market owing to their features like excellent performance, longer life span, and less power consumption.

(https://www.servostabiliser.com/) Established in the year 2007, we, “Beta Power Controls”, are a leading manufacturer of Isolation Transformer, Automatic Voltage Controller and Servo Stabilizer. The offered range of product includes Servo Stabilizer, AC Voltage Regulator, Isolation Transformer and many more to name in the catalog. The products manufactured by us have made a distinct place in the market owing to their features like excellent performance, longer life span, and less power consumption.

More Related Content

More from IndiaMART InterMESH Limited

Related Books

Free with a 14 day trial from Scribd

See all

Related Audiobooks

Free with a 14 day trial from Scribd

See all

Electronic Equipments By Beta Power Controls

  1. 1. BETA POWER CONTROLS ISO 9001-2015 CERTIFIED COMPANY Since 2007
  2. 2. STABLIZER Servo Voltage Stabilizer - 15 Static Stabilizer - 17 TRANSFORMER Isolation Transformers - 20 Ultra Isolation Transformer - 20 K-rated Isolation Transformers - 21 Resin Cast Transformers - 21 Step Up /Step Down Auto Transformers - 21 Control Transformers - 22 Drive Input/Output Chokes - 22 Harmonic Reactors - 22 Variable Auto Transformer - 23 CONVERTERS Single Phase To Three Phase - 24 Two Phase To Three Phase - 24 Static Frequency Converter - 25 Rotary Frequency Convertor - 26 UPS - 27 Rectifier - 28 Harmonic Filter - 30 CONTROL PANEL LT Panel - 33 APFC Panel - 34 Power Control Center (PCC Panel) - 35 Motor Control Center (MCC Panel) - 35 MV Panel - 36 LOAD BANK - 36 AUTOMATION PANEL PLC Panel - 37 VFD Control Panel - 38 Scada Control Panel Systems - 39 PLC & HMI Panels - 39 ENERGY SAVER Energy Saving Equipment - 40 Solar Project - 42 CONTENTS
  3. 3. BETA POWER CONTROLS, COIMBATORE, INDIA AN ISO 9001:2015 TVE ACCREDITED COMPANY, Leading manufacturing &Exports Established in 2007 with a corporate objective to provide efficient energy for greener future, Beta power controls has grown to be one of the country’s biggest manufacturers of power saving and power conditioning equipment’s with the largest satisfied customer base. The products manufactured by us have made a distinct place in the market owing to their features like excellent performance, longer lifespan and less power consumption. with an objective to manufacture quality products, our experts use the latest equipment and best quality raw material provided by our trusted vendors of the market. OUR SERVICES ▪ Servo Voltage Stabilizer ▪ Static Stabilizer ▪ Isolation Transformer ▪ UPS ▪ Control Transformer ▪ Voltage Variable Transformer ▪ Special Purpose Transformer ▪ Rectifiers ▪ Phase Converters ▪ Frequency Converter ▪ Harmonic Filter ▪ APFC Panel ▪ VFD Panel ▪ Electrical Panel ▪ Control Panel ▪ Plc Panel ▪ Energy Saving Equipment ▪ Solar Project ▪ Load Bank ▪ Maintenance ET Spare Support. QUALITY POLICY BETA POWER CONTROLS is committed to satisfy the customer by supplying the quality products as per customer’s specification at reasonable price and will continually improve the effectiveness of quality improvement system. OUR VISION Our vision is to become a technology based Indian Engineering Company & to emerge out as a leading manufacturer in the domestic & international market. OUR MISSION “It’s our mission to strive for synergy between technology, systems and human resources, to produce products and services that meet the quality, performance and price aspirations of our customers. while doing so, we maintain the highest standards of ethics and social responsibilities. CUSTOMER SATISFACTION Quality for us is not just a word that defines our product but our capability to achieve complete customer satisfaction. Working with the prime focus of achieving complete customer satisfaction, we work in coordination with our clients to conceptualize their idea and manufacture machines exactly as per their requirements. We also provide our customers excellent after sale service for the maintenance and long service life of the machine. Equipped with the most sophisticated technology and competent engineers, we have innate capability to meet every requirement of our esteemed customers.
  4. 4. AFTER SALE SUPPORT In a quest to ensure complete customer satisfaction, we provide excellent customer service to our customers. We also offer customer friendly technical assistance for new installation where highly qualified engineers attend the queries. R&D Our R&D team has always kept us ahead by developing innovative products for usages in various industrial applications. Committed to providing the best solution, our R&D team carries out intensive research for developing components of varied configurations as per the requirement of our clients. Our R&D department aims at developing cost effective and improved performance products to meet the ever-changing requirements our customers. FIELD OF APPLICATION: ▪ Cement Plants ▪ Flour Mills ▪ Clubs ▪ Engineering Units ▪ Hotels ▪ Pharmaceutical Units ▪ Hot & Cold Rolling Mills ▪ Rice Shellers ▪ Textile Mills ▪ Paper Mills ▪ Rubber ▪ Cold Storages ▪ Food Processing Unit ▪ Hospitals ▪ Nursing Homes ▪ Tea Estate ▪ Food ware ▪ Leather Units ▪ Distilleries & Beverages ▪ Tube Mills ▪ Oil & Vanaspati Plants ▪ High Rise Buildings ▪ Industries EXPORTS We regularly Exports more than 30 countries.
  5. 5. APPROVALS
  6. 6. APPROVALS
  7. 7. CERTIFICATE
  8. 8. LEADERSHIP Mr. Balkrishnan Sethuram (Chief Executive Officer) Mr. Senthil kumaran (Executive officer) Mr. Durairaj V (Manager) Mr. Vinoth Babu (R&d) Mr. Thaiyappan (Electronic scientist) Mr. Vijayakumar (Sr. Advisor – Distribution /Transmission) PRODUCTION ENGINEERS SERVICE ENGINEERS SALES & MARKETING ACCOUNTS & ADMINISTRATION 17 08 04 06 OUR EMPLOYEES
  9. 9. OUR VALUABLE CUSTOMERS BETA POWER CONTROLS ISO 9001-2015 CERTIFIED COMPANY
  10. 10. GLOBAL CUSTOMERS Customer Name City Country Contact Name JAZZAH FACTORY ALUMINIUM PRODUCTION Riyadh Saudi Arabia Manu Krishna AL WADI ALSAFI WATER PURIFICATION Sharjah UAE Sudesh FINKEN HOLDINGS LTD Nairobi Kenya John wanjohi muchemi ARUTHUR OLUAL Nairobi Kenya Aruthur olual ARAR UTILITY & TRADING WLL Doha Qatar Nirmal kumar TECHNO GEARS INDUSTRIES L.L.C Muscut Oman Munna FAMILY BAKERS Male Maladives IZZATH RASHEED ALMOAYYED AIR CONDITIONING Manama Bahrain Sankar Ganesh KOTROL TEK LTD Bridgend UK Martin kelly RESPACK POLYFILM SDN BHD KEDAH Malaysia CK Wan SMH RAIL SDN. BHD. Kuala lumpur Malaysia Jamesh KAWAS ENGINEERING LLC Muscut Oman Amith TASK PLASTIC INDUSTRY PLC Djibouti Ethiopia Reji Abraham INTACT CONTROL TRANSFORMER LLC Dubai UAE Sangeetha ISA SARAL Lubambashi RD Congo Suresh UNITED BUSINESS COMPANY LLC Jeddah Saudi Arabia Rajeeve PLQ CONTRACTING LLC Dubai UAE Nirmal JOAO MANUEL SEQUNDA Luanda Angola Joao manuel sequnda ATLAS AL SHARRQ TRADING EST Dubai UAE Mohammed saleh Ali POWER LINKS CONTRACTING W. L .L Tubli Bahrain SANKAR E K PARTNERS LLC Sharjah UAE lMohammed ALIF TRADING CO Doha Qatar Yasir Sherrif GEODIS PROJECTS CAMEROON Douala Cameroon Kadidja UNITED HYDROCARBON CHAD LIMITED Djamena Chad Harikumar DELONEX ENERGY UK LIMITED London UK Edna Freitas JAGDAMBA STEELS PVT LTD Kathmandu Nepal Promod rauniyar SIMONES NEPAL PVT.LTD Kathmandu Nepal Krishna TANELEC ZAMBIA LIMITED Ndola Zambia Nyaude Bada MODERN UNION PAPER PRODUCTS Dubai UAE Alphonse paul FIRST POINT PRINTING EQUIPMENTS Sharjah UAE Ram UNIQUE ELECTRICALS PTE LTD Singapore Singapore Suresh RT KNITS Upper vale Mauritius Shameem Russool
  11. 11. ACCOLADE CONSULTANCY AND ENGG The Adelphi Singapore CREET INTERNATIONAL CONTRACTING COMPANY LTD Riyadh Saudi Arabia Ayman Customer Name City Country Contact Name BAKHRESA GRAIN MILLING (U) LTD Kampala Uganda Pursothaman SULTAN CO FOR PLASTIC INDUSTRIES Tripoli Libya Eng. Mohammad La corne d'abondance Versailles France Daniel Tonini La maison d'Asie Toulouse France Annette Roulet Laughing Bacchus Wine Cellars Vancouver Canada Yoshi Tannamuri Lazy K Kountry Store Walla Walla USA John Steel Lehmanns Marktstand Frankfurt a.M. Germany Renate Messner Let's Stop N Shop San Francisco USA Jaime Yorres LILA-Supermercado Barquisimeto Venezuela Carlos González LINO-Delicateses I. de Margarita Venezuela Felipe Izquierdo Lonesome Pine Restaurant Portland USA Fran Wilson Magazzini Alimentari Riuniti Bergamo Italy Giovanni Rovelli Maison Dewey Bruxelles Belgium Catherine Dewey Mère Paillarde Montréal Canada Jean Fresnière Morgenstern Gesundkost Leipzig Germany Alexander Feuer North/South London UK Simon Crowther Océano Atlántico Ltda. Buenos Aires Argentina Yvonne Moncada Old World Delicatessen Anchorage USA Rene Phillips Ottilies Käseladen Köln Germany Henriette Pfalzheim SUMO CONSTRUCCTION & ENGINEERING PVT LTD. Kathmandu Nepal Mr.Sandip DEYA ELEVATOR SERVICE INC Guayanabo Puerto Rico Ms.Angel CUSTOMER DELIGHT TRADING Abu Dhabi UAE Mario Pontes PT CATUR HARAPAN BATAM Indonesia Paneer GLOBAL CUSTOMERS
  12. 12. ▪ All bought out components sourced from reputed manufacturer and supplier as per standards. ▪ 100 % Raw materials inspection s per internal Quality Plan. ▪ Individual assemblies and sub-assemblies tested separately. ▪ All Electronics PCB’s are tested at 60 oC in oven. ▪ Final Equipment’s are tested for 24 hours with continuous voltage variation from min. to max. INSTRUMENTS USED FOR TESTING SR NO Analog Insulation Meter MG-01 High Voltage Tester HV-01 Power Analyzer PA-01 Digital Clamp Meter DCM-02 Infrared Thermometer TG-01 FACTORY TEST is 9815: 1994, Part I indicates the various routine tests to be conducted on the stabilizer before dispatch from the factory. The brief description of these tests are as below: INSULATION TEST: The insulation between the terminals and body of the stabilizer shall not be less than 5 MΩ when measured with a 500 V megger at the ambient not exceeding 45 °C. HIGH VOLTAGE TEST:2.5kV(RMS) test voltage shall be applied at the rated frequency for one minute between the windings and the body of the stabilizer after connecting the body of the stabilizer to the earth. There shall not be any disruptive discharge or collapse of test voltage during this test. OUTPUT VOLTAGE TEST: The output voltage shall be for different input voltages from no load and min Load 10A. the test can be limited to no load if it is not feasible to load actually. The output voltage by this test shall not differ by more than 2 % of the designated rated voltage. NO LOAD CURRENT TEST: The no load current shall not exceed 5% of the rated full load output current. LOAD TEST: This test shall be conducted similar to the test to the transformer. The total losses shall not be more than 10 % for capacities up to 5 kVA and 5 % for higher capacities. 
 INDUCED VOLTAGE TEST: This test conducted to test the insulation of winding by applying AC voltage equal to output voltage of frequency not less than twice the rated frequency at the output terminal of the windings for periods not less than 15 seconds. After this test there shall not be any appreciable differences in the no load current with reference to the no load current at normal frequency. TEST FOR CONTINUOUS OPERATION(JIGTEST):By this test the stabilizer is subjected to the continuous run for 24 hours at no load while the input voltage is automatically varied from minimum to the maximum of the designated input voltage and back to the minimum in not more than one minute. After this test the stabilizer shall pass the output voltage test. TEMPERATURE RISE TEST: This test is similar to the temperature rises to transformer and is done under actual plant condition. 1A) QUALITY ASSURANCE 1b) Testing of Procedure
  13. 13. WORKING OF SERVO VOLTAGE STABLIZER Servo voltage stablizers work on servo mechanism which is negative feedback used to generate control over voltage fluctuations.In servo voltage stablizers,there is a boost/buck transformer component which is primarily used to regulate & control the input voltage. SERVO VOLTAGE STABLIZER ADVATAGES OF SERVO VOLTAGE STABLIZER • It can support load capacity up to 5000 KVA and more • Great voltage accuracy with +/- voltage correction • Wide utility area like from home to school, industries and offices • Available in both Air-cooled and oil cooled transformers • Affordable and fit in the budget • Fast and accurate • No maintains cost • Highly efficient • Higher durability and great reliability
  14. 14. TECHNICAL SPECIFICATION Characteristics Single phase Three phase Capacity 1kva-50KVA 3kva-5000KVA Input voltage Output voltage Frequncy 50/60HZ Correction speed 20v/sec , 70v/sec , 110v/sec (As Required) Response time Less then 10 milliseconds Correction method Step less correction using variac (Microprocessor Based control system for measurement and correction) Waveform Distortion Nil Effect of power factor Nil Efficiency 98% As per IS standards Type of cooling Nature Air cooled /Forced air cooled/Oil cooled Duty cycle Continuous 24 hrs 100% No load losses 0.5% from the rated capacity/ As per Is standards Operation mode Auto /Manual Suitability Suitable for 3phase,4wire Unbalanced Voltage & Unbalanced/balanced load all power factors Operating Temperature 0 to 55 Humidity 0 to 95% RH Max ,Noncondensing at 35 Noise Level <65dB For 1meter High voltage Test Can withstand 2.5kV for 5 seconds System construction As per IS : 9815 & ISO 2015 Degree of protection Ip21 - IP 55 (As Required) & Epoxy Powder coated ( 7 Tank processes) Insulation Class- B /Class- H / Class – F (As Required) MCB / MCCB Short circuit Protection BYPASS Inbuilt in up to 300KVA above 300Kva optional (Change over Switch to bypass the stabilizer and use main voltage directly) CONTACTOR Over load ,Under /Over voltage cut – Off Protection Through contactors Log book memory History of error logs Input /Output Terminations DIN Connectors up to 75Kva Above 75kva Busbar Connection Monitoring facility DIGITAL MICROPROCESSOR LCD DISPLAY FOR A. Input Voltage - Phase to Neutral & Phase to Phase D. Frequency B. Output Voltage – Phase to Neutral & Phase to Phase E. Earth Neutral Voltage C. Load Current in Three Phase F. Fault annunciation 197v- 277v 360v-460v 170v-270v 340v-480v 140v-270v 295v-470v 110v-270v 240v-460v 90v-270v 190v-460v 220v/230v +/- 1% (Adjustable) 380v/400v/415v +/-1%(Adjustable) 1 Phase + Neutral, Ground 3 Phase + Neutral, Ground Other Range also available as per customer requirements Optional Features and Protections 1. Low voltage cut-Off & Alarm 2. High voltage cut-Off & Alar 3. Over Load Cut-Off & Alarm 4. Single Phase Prevention Cut-Off & Alarm 5. Reverse Phase Cut-Off & Alarm 6. Neutral Trip 7. Auto Phase Correction in case of Phase Reversal 8. Short Circuit Protection for Input MCB/MCCB/ACP 9. Surge & spike Protection. 10. Stabilizer Bypass System 11. Delay on Circuits 12. Auto / manual operation
  15. 15. Why Static Voltage Stabilizers? • Super quick response time of 50 microseconds • Fast regulation speed of 2500 volt/sec (minimum) • Continuous supply of highly stable output voltage • Independent phase correction and capable to handle unbalanced 3- phase input without any trouble • Built in protections against: over / under voltage, phase reversal, single phasing, over load, over temperature & short circuit • Zero maintenance cost because of no mechanical or moving parts. • Completely noiseless operation • Lowest foot print (less space needed) • Compatible for all kinds of loads • >99.8% efficiency • Greatly improves power quality and reduces electricity consumption at site of installation STATIC STABILIZER
  16. 16. Operating Voltage 1F+F (225-470VAC) Standard Input Voltage Ranges 1F+F (300-450V)Standard Output Voltage 1F+N 380 VAC +/- %1~3 Standard ( 400V ve 415V optional ) Control and Process Control Multi-Microprocessor Control (DSPIC) Operating Frequency 50 Hz +/-%5 (60 Hz Adjustable ) Efficiency >%97 ( in nominal terms, at full load ) Operating Temperature -10 C lie + 50 C range ( Special cooling unit ) Protection Pasive and electronic Protection (Overvoltage, under voltage, overcurrent, peak, surge, right and spike protection) Display Graphic LCD Display for each Phase Output Voltage, Output Voltage, Output Current, Load Percentage, Output Frequency, Regulator Status and Fault Information, Overload Warning, Input Fault Warning, Output Fault Warning, etc. information can be monitored. Communication Dry Contact ( Optional; Ethernet /USB / MODBUS TCP/IP ) Filter At the entrance of the system there is an electricity noise filtering special filter system and network filters. By Pass Manuel by pass (Opsiyonel; Auto By Pass ) Relative humidity %90 ( condensing ) Acoustic Noise 50 dB(A)'less Protection Class Ip 20 ( Optional; Outdoor Cabinet ) Standards EN50091-1/EN62040-1(Safety) EN50091-2/EN62040-2 (EMC TECHNICAL SPECIFICATION
  17. 17. TRANSFORMER What is an Isolation Transformer? A transformer is a static electrical device which transfers power from one voltage level to another while keeping the frequency same. And, if the primary and secondary windings are coupled through a common iron core, they are considered as the Isolation Transformer. The secondary winding, as usual in transformers, is physically and electrically isolated from the primary winding. There is no literal electrical link between the two windings. They are magnetically coupled, not electrically linked. This “line isolation” is a very desirable characteristic for various applications. As there is no electrical connection between the load and source, the transformer behaves like a filter between the two windings by segregating them from each other. The Isolation Transformers significantly block the voltage spikes, switching transients and noise that originate in the supply side from being getting transferred to the load side. Some isolation transformers are built with a turn ratio of 1:1. Such transformers are exclusively built to have the same input and output voltage and are used for isolation only. All transformers except autotransformers provide isolation. When used with a switching power supply, an Isolation Transformer prevents higher-order harmonic signals from degrading the performance of adjoining circuitry. It is especially crucial in computers or other equipment incorporating microprocessors. Improper isolation can cause interference to other functions of the system and can cause excess ripples at the output voltage waveform. What are the Benefits of Isolation transformers? The Isolation Transformers have numerous benefits as- • Protection of the users from the faulty equipment. • To have safe, reliable and accurate measurements. • To avoid ground loops. • To physically isolate/separate some part of an electrical system from the other or rest of the system. • On drives, they help to filter the electrical noise caused by SCR’s
  18. 18. ISOLATION TRANSFORMERS INPUT OUTPUT RATING AVAILABLE 400V AC 3 PH 400V AC 3 PH 1 KVA TO 2000 KVA 230V AC 1 PH 230V AC 1 PH 1 KVA TO 20 KVA Or as per requirement Both Oil & Dry type System Connections Delta/star(as per requirement) Ratios Delta /Star (as per requirement) Regulation 5% Insulation resistance Better then 5Mega ohm Coupling capacitance 0.01 PF for 100Db Leakage current Less than 20 Micro Amps Type of Execution Closed Type Operating Temperature 0 c to 45 c Type of Cooling ONAN/Natural Air/Forced air TECHNICAL SPECIFICATION
  19. 19. K-RATED ISOLTION TRANSFORMERS K factor is a value used to determine how, much harmonic current a transformer can withstand without exceeding its maximum temperature level. Huge numbers of single phase loads like computer also creates a non- linear harmonic. A standard transformer cannot handle the harmonics due to non- linear loads. When harmonic enter into the transformer the core gets saturated, as result it produces lot of heating causing the failure of the transformer. K Rated transformers are specially designed to withstand this non-linear harmonic. K rating differs according to the harmonics level like K-1,K-4,K-7, k-13, and K-20 RESIN CAST TRANSFORMERS Cast resin transformers are characterized by the conductors of winding being embedded in an enclosed resin body completely with a smooth surface. Cast resin transformers is used where safety, pollution and economy matters. Beta power controls Resin cast transformers are designed to withstand toughest environment conditions and offer high level of reliability even under the toughest condition. Our resin cast transformer can be installed in E4 environment class. FEATURS OF BETA RESIN CAST TRANSFORMER 1. High security 2. Reduced cost 3. Low fire risk 4. Maintenance free 5. Completely sealed winding 6. High mechanical strength for the winding 7. High grade core with minimum losses STEP UP /STEP DOWN AUTO TRANSFORMERS An auto transformer is a device where same part of the winding acts as primary and secondary side of the transformer. Auto transformer is often used to step up and step down the voltages. Auto transformer does not provide Electrical isolation between the winding. In an auto transformers primary & secondary are connected magnetically and electrically insulated Step up transformers is one whose secondary voltage is greater than primary voltage. This kind of transformers used to “STEP Up” the voltage applied to it. Step Down transformer is one whose secondary voltage is lower then primary voltage. This kind of transformer used to “STEP DOWN” the voltage applied on it.
  20. 20. CONTROL TRANSFORMERS A Control transformer are to supply power to control and auxiliary equipment’s which are not intended to connect direct supply. Control transformers are used to control supply voltage for control circuits of AC starter motor i.e. starter coils, timers, indicating lamps, electronics protection relay, etc., A control transformer is used to supply control power thus allowing lower ,safer and more efficient control circuit voltage to be used in high working voltages applications The excellent inrush current handling characteristics of the transformer also makes the system more efficient. DRIVE INPUT/OUTPUT CHOKES Utilizing variable speed drives to control motor speed has impacted industry in energy saving and increased efficiencies. The challenges for today’s designers is dealing with non-linear waveform generated by solid state devices. By choosing our line reactor, many line problems can be eliminated. Additionally performance life expectancy of both the motor and the drive itself are significantly enhanced. HARMONIC REACTORS De tuned filter Reactors, are used in series with capacitor banks in power factor correction units. By using these type of detuned reactors it is possible to avoid following effects on system.
  21. 21. VARIABLE AUTO TRANSFORMER As with two winding transformer , auto transformer may be equipped with many taps and automatic switchgear to allow them to act as automatic voltage regulators, to maintain a steady voltage at the customers service during a wide range of load conditions. A Auto transformer is also a single wound transformer with two end terminals and one or more terminals at intermediate tap points. The primary voltage taken from the terminals almost having one terminal in common with primary voltage. SPECIFICATION REQUIREMENT CAPACITY 1 A -5000A INPUT PHASE SINGLE PHASE THREE PHASE INPUT VOLTAGE 230V 400V OUTPUT VOLTAGE 0-270 0-470 COOLING AIR COOLED OR OIL COOLED VECTOR GROUP DYN-11 REFERENCE STANDARD ACCORDANCE WITH RELEVANT IEC AND EN AMBIENT TEMPERATURE 0-60 Deg.C VOLTAGE VARIATION MANUL OR MOTORIZED VARIABLE FREQUNCY 50/60HZ +-3% INSULTION CLASS F % REACTANCE 2-3% DUTY CONTINUOUS WINDING COPPER 99.9% ELECTROLYTIC CORE TYPE ,GRADE OF LAMINATION CRGO TOROIDAL CONSTRUCTION,M3,0.23MM METERING I/P VOLTAGE,O/P VOLTAGE,O/P AMS PROTECTION MCCB FOR INPUT TECHNICAL SPECIFICATION
  22. 22. PHASE CONVERTERS SINGLE PHASE TO THREE PHASE BETA phase converter is a device that converts single phase electrical to 3 phase supply. Most phase converters are used to produce three-phase electric power from a single-phase source, thus allowing the operation of three-phase equipment at a site that only has single-phase electrical power supply. BETA Phase converter first converts 230v single phase supply to 440v through step up transformer and it again given to AC derive where the 3 phase AC supply is given to the electrical load through converting DC to AC. TWO PHASE TO THREE PHASE three-phase power is not always available. To keep cost down, often only one phase is fed from a street transformer to a house. There are two options, if an industrial machine has to be connected. Installation cost for three-phase power lines may be high. Phase convert two phase 415v into three phase 380v,400vor415v.Booster: standard converters for multi-motor applications. Motors will produce 100% nameplate torque continuously, up to 200% during start-up or excessive loads. One output socket. Booster e: high performance converters for all single and multi-motor applications and all hard- start conditions. Motors will produce 100% of nameplate torque continuously and up to 600% during motor start-ups and excessive loads. Two output sockets. For all motor start-stop, reverse, hard-start conditions (metal lathes, wheel balancers, irrigation pumps, conveyors, elevators, refrigeration systems, compressors, deep submersible pumps, hydraulic systems). INPUT PHASE SINGLE PHASE TWO PHASE CAPACITY 1HP -15HP 1HP - 300HP INPUT VOLTAGE 230V 400V INPUT RANGE 200-250V 340-460V Other Range also available as per customer requirements OUTPUT VOLTAGE 400V OUTPUT PHASE 3 PHASE 3 WIRE (R, Y, B) OR 3 PHASE 4 WIRE (R,Y,B,N) as per customer requirements INPUT FREQUENY 50/60HZ +-0.5% OUTOUT FREQUENCY 50/60HZ +-0.5% POWER FACTOR 0.95 EFFICIENCY <97% COOLING FORCED AIR COOLED PROTECTION I/P AC OVER VOLTAGE/UNDER VOLTAGE,O/P OVER LOAD, SHORT CIRCUIT PROTECTION TECHNICAL SPECIFICATION
  23. 23. FREQUENCY CONVERTER What is the frequency converter? Frequency converter outputs the AC power to pure sine wave after the transformation of AC→DC→AC, the output frequency and voltage can be adjusted within a certain range. It is different from the variable frequency drive used for motor speed regulation, and also different from the common AC regulated power supply. An ideal AC power supply is characterized by stable frequency, stable voltage, zero internal resistance and pure sinusoidal voltage waveform (without distortion). Frequency converter is quite close to the ideal AC power supply, so more and more countries use it as standard power supply to provide the best power supply environment for electrical appliances, so as to assess the technical performance of electrical appliances. TECHNICAL SPECIFICATION Characteristics Capacity 3KVA TO 2000KVA Number of Phase 1 phase or 3 phase Input Voltage 110V TO 600V 3W or 3W+N Input Frequency either 50Hz or 60 Hz Output Voltage 110V TO 600V 3W or 3W +N Output Frequency either 50±0.5Hz or 60±0.6Hz or 400±2Hz Waveform Pure Sine Wave Response Time 10ms Noise Level soundproof 65dBA Type of cooling Nature air cooled/Forced air cooled Efficiency 92% Instruments Status Lamp, Voltmeter, Ammeter, Frequency Meter, Thermometer MONITORING FACILITY INPUT VOLTAGE & OUTPUT VOLTAGE INPUT FREQUENY & OUTPUT FREQUENCY OUTPUT LOAD
  24. 24. ROTARY FREQUNCY CONVERTOR Characteristics Capacity 50KVA TO 5000KVA Number of Phase 1 phase or 3 phase Input Voltage 110V TO 600V 3W or 3W+N Input Frequency either 50Hz or 60 Hz Output Voltage 110V TO 600V 3W or 3W +N Output Frequency either 50±0.5Hz or 60±0.6Hz or 400±2Hz Waveform Pure Sine Wave Response Time 20ms Coupling Belts and Pulleys System or Common Shaft or Direct Coupler Soft Start Soft Starter Control Circuitry or Soft Starting Technology Efficiency 92% Instruments Status Lamp, Voltmeter, Ammeter, Frequency Meter, Thermometer Protections Fuses, Over Current, Under Voltage, Under Frequency, Over Frequency, Over Temperature Type of cooling Nature air cooled/Forced air cooled Noise Level Standard 88dBA, low noise 75dBA or soundproof 65dBA Monitoring facility HMI A. Input voltage B. Output voltage C. Input Frequency D. Output Frequency E. Load Current F. Fault Annunciation TECHNICAL SPECIFICATION
  25. 25. UPS ( Uninterruptible power supply ) In an online UPS, the batteries are always connected to the inverter, so it isn’t necessary to have a power transfer switch. When a loss of power occurs, the rectifier just drops out of the circuit and the batteries keep the flow of power steady and unchanged. When the power is restored, the rectifier resumes carrying most of the load and also begins charging the batteries. However, the charging current may be limited to prevent the high-power rectifier from overheating the batteries and boiling off the electrolyte. The most beneficial advantage of an on-line UPS, in comparison with the other types of UPS, is its ability to provide an “electrical firewall” between the incoming utility power and sensitive electronic equipment. The online UPS is ideal for environments where electrical isolation is necessary or for equipment that is very sensitive to power fluctuations. However, with the advances in technology, the online UPS unit was once only used for very large installations of 10 kW or more. Now they are available as a common consumer device, supplying 500 W or less. The initial cost of the online UPS may be higher, but its total cost of ownership is generally lower due to longer battery life. The online UPS may be necessary when the power environment is “noisy”, when utility power sags, outages and other anomalies are frequent, when protection of sensitive IT equipment loads are required or when operation from an extended-run backup generator is necessary. The basic technology of the online UPS is the same as in the standby or line-interactive UPS. However, it typically costs much more, due to it having a much greater current AC-to- DC battery-charger/rectifier, and with the rectifier and inverter designed to run continuously with improved cooling systems. It is called a double-conversion UPS due to the rectifier directly driving the inverter, even when powered from normal AC current. Input connection Dual input, hardwired Output connection Hardwired Nominal input voltage (Vac) 220/230/240 Vac single phase; 220/380, 230/400, 240/415 Vac three phase Input voltage range +10%, -15% Operating frequency 50/60 Hz (45 to 65 Hz) Input power factor 0.99 Input current distortion 5% THD Nominal output voltage 220/230/240 VAC single phase Output voltage regulation ±2% static; ±5% dynamic at 100% load change, <1 ms response time Overload capacity 150% for 5 sec / 125% for 1 min (online), 1000% for 5 msec (bypass) Efficiency 92% with nominal linear load; 91% with nominal computer load. User interface LCD-display Std. Graphical LDC with blue back light; English, Germany, French and Spanish language support as standard. Standard communication ports 1 x RS232 for local support, 2 x X-slot (empty); 1 x relay contacts, 1 x emergency power off input Optional External battery cabinets; Isolation transformer; X-slot: SNMP/web, Modbus/Jbus, Relay card;
  26. 26. Reasons to choosing us…. Work in optimizing system regulationMaximum stability Excellent power quality even under weakgrid conditions Independent voltageand current control Maximum flexibility with respect to raw material types − Robust and reliable de- sign Reasons for choosing BETA Customized rectifier, transformer and DC reactor system Intelligent control add-on packages for even higher electrode regulation performance Support throughout the full life cycle and access to our worldwide 24x7 support line Vast experience in various DC applications Total power system simulation capability Integration of rectifier and power quality control equipment to enhance flickerperformance RECTIFIERS OUR WATER-COOLED THYRISTORS • High power density • Compact design/small dimensions • Integration in already existing cooling • Systems/heat recovery • No fire protection measures required • No environmental constraints • Low maintenance requirements • Micro SCADA interfaceable OPTIONAL An intuitive touchscreen controller Integrated with a programmable logic Controller that features: • System protection • Dynamic unit response • Easy to browse menus
  27. 27. SupplyVoltage: Up to 0.48kV VAC ±5%, 1 –3Phase, 45-60 Hz Output Voltage: Upto 400V (Custom higher outputs avail- able) Output Current: Upto 5000A (Custom higher outputs available) Pulse: Up to 24 pulse system Ambient Temp: Max 40°C Protection Class: NEMA 1 Cooling: Air or water-cooled with air to water or water to water heat exchangers Control Precision: Voltage/current ±1% Regulation Range: Stepless at constant voltage or current 10- 100% Documentation We provide Factory Test Report(Routine Test) As per standard & Instruction Operation Manul Book,(Third party test certification SGS,SASO,INTEK Which can be incorporated extra cost) Oil cooled voltage variable rectifier Air cooled rectifier TECHNICAL SPECIFICATION
  28. 28. SYMPTOMS OF HARMONICS WHEN IT PRESENT IN SYSTEM • Increase KVA Demand. • Neutral Over loading & excessive N-G Voltage. • Excessive Capacitor current, frequent capacitor failure. • Overheating of transformer. • Error in electricity metering i.e. erratic meter reading. CAUSES OF HARMONICS Harmonics are generated by various sources which inherently have non – linear load like VFD, Diode, Computer, & all electronics equipment’s. That is generally where frequency as well as voltage conversion system are used. These loads use current in a pulsating manner at times of feed harmonic currents back in to the wiring. In non-linear load current waveform is different from voltage waveform. The major equipment’s which generates Harmonics. • AC /DC Drives • VFD • LED • Booster • Converters • Electronics load HARMONIC FILTER PLANT STANDARD HARMONIC LIMIT AS PER IEEE Institute Electrical & Electronics Engineering (IEEE) has set recommended limit on both current & voltage distortion in IEEE 519-1992 Sr. No. Bus Voltage at PCC Individual Voltage Distortion Total Voltage Distortion 1 Below 69 kV 3.0 5.0 2 69 kV to 161 kV 1.5 2.5 3 161 kV & above 1.0 1.5 Voltage Harmonics Distortion Limit
  29. 29. HARMONICS FILTER CONSISTS OF 1. Double Dielectric type ultra-heavy duty All PP Capacitor 2. Dry type Aluminum / Copper Reactor (percentage of reactance is depends on harmonics level) 3. Conducting Material: 99% pure Aluminum foil 4. Housing — CRCA / Stainless steel Panel. 5. Busbar – Aluminum / Copper. 6. Finish – Anti corrosive & UV Protected powder coating. Active Harmonic Filtering Provides harmonic compensation by being installed on the line side of the offendingload (for example, VSD).They introduce current waveforms which cancel out undesired harmonic components. Trend Impact Line and load reactors Reactors are used to provide current limiting. Reactors oppose rapid changes in current and hence limit spikes as a result of current pulses Passive harmonic filtering Uses a combination of reactors and capacitors to filter out harmonic frequencies.
  30. 30. Grid voltage (+10/-15% 415 ˜ 690 Urms Grid Frequency 50Hz(+/-)5% (60Hz on request) FILTER Inverter technology 2-level /3-level/Multi-level Controller 32-bit digital signal processors Reactive compensation Both leading/lagging Load balancing Yes(negative sequence) Harmonic range All natural harmonics up to51st order(zerosequence in APF3+N model only Individual harmonic selection Available Magnetics Solid core technology C.T secondary 5A Interface(communication) MODBUS TCP, USB, Ethernet, SD Card, CAN. PHYSICAL CHARACTERISTICS Protection class 1130/IP41(higher on request) Cooling Forced air cooling Overheating protection Yes Cable entry Bottom /top (on request) ENVIRONMENTAL Ambient temperature Upto 45Deg Relative Humidity 95%(non condensing) Maximum operating altitude 1500m Acoustic noise(at1m) <70db USER INTERFACE HMI BETA POWER CONTROLS offers the advanced HMI in the industry PROTECTIONS AND STANDARDS Hardware protections MCCB,Fuses,Gate Driver protection for IGBT,over temperature cutoff, single phasing, Software protections DC over voltage, over current, no synchronization, voltage high/low, improper phasesequence, temperature derating. Total harmonic current distortion THDi * <8% @ rated power for drives without Ldc <5% @ rated power for drives equipped with 4% Ldc Efficiency >99% for rated voltage and power Overload capability 1.6x rated current for 1 minute, once per hour SCCR** 100 kA (UL approved) High potential test voltage P -> E 2520 VAC (1s) Overvoltage category OV III (IEC 60664-1) Cooling External cooling Ambient temperature range –25°C to +40°C fully operational | +40°C to +70°C derated operation**** | – 25°C to +85°C transport and storage Flammability corresponding to UL 94 V-0 TECHNICAL SPECIFICATION
  31. 31. Electrical Panels are primarily designed to distribute and control the power for various mechanical implements. These panels are unit products of smart quality raw materials in accordance with industrial quality standards. Electrical control panels are widely used in the industrial and commercial sector for various applications and utilities, including commercial buildings, hospitals, dairies, telecommunications, research laboratories, and others. There are primarily two types of electrical panels available in the market – High Tension (HT) and Low Tension (LT) panels, each one is designed for a specific arrangement and include devices to operate specific equipment LT Panels are used with low tension cables to obtain power from the generator or transformer and distribute electricity to various electrical devices and distribution boards. LT panels are designed to function at lower voltages (up to 690 Volts) with low insulation levels. L.T PANEL SPECIFICATION AS PER CUSTOMER REQUIREMENTS
  32. 32. Automatic power factor control or APFC panels are mainly used for the improvement of power Factor. Power factor is the ratio of active power to apparent power and it is a major component in measuring electrical consumption. APFC is an automatic power factor control panel which is used to improve the power factor, whenever required, by switching ON and OFF the required capacitor bank units automatically. Control APFC PANEL Parameters Design Standardized Modular Sheet Steel Enclosures Rated Voltage 415V-440V/50Hz (Design available for 380V, 480V, 690V, 750V - 50/60Hz) Output Rating Refer to the table Other output ratings, switching combination or design voltages are available upon request Capacitors DUCA POWDER Super Heavy Duty Series used are rated at525V, 690V and 880V, 50/60Hz as per network voltage Reactors H-Class5.6%, 7%,14% or other Tuning/Detuning rating on request Incoming / Outgoing MCCB / ACB as Incomer and HRC Fuses for backup protection (other combination on request) Protection class IP 40 Unbalanced Activcomp System For Unbalanced ACTi comp System ratings &specifications Contact our Sales Office TECHNICAL SPECIFICATION
  33. 33. Let's get started! First, let's talk about the power control center (PCC Panel), PCC panel contains all of the electrical switchgear like an air circuit breaker, MCC’s, MCB, and suitable size aluminum or copper busbar. The main circuit breaker is where the power comes into the control panel for all of the switchgear. This circuit breaker generally has an isolate on the panel that allows us to shut off the power. Always remember the incoming side of the breaker will still have power. The power that comes into the panel can be anywhere from 440 volts to 800V AC. POWER CONTROL CENTER (PCC Panel) SPECIFICATION AS PER CUSTOMER REQUIREMENTS In many commercial and Industry applications, multiple electric motors are required, and it is often desirable to control some of the motors. The apparatus designed for this type of function is the motor control center panel (MCC Panel).When a motor operation runs with the protection of overload relays or solid-state motor controllers. An MCC Panel manufacturer has a control from a remote or local that is called a motor control panel. There are combinations of different types of starters like direct online (DOL) Starter or star-delta starter. MCC Panel (motor control center) is using for motor control of various electrical power Industries. Therefore, it is most important in electricity. MCC panel is an Electrical control panel in LT panels. In other words, it can control the motor from generation to production MCC PANEL SPECIFICATION AS PER CUSTOMER REQUIREMENTS
  34. 34. From 3 KV to 36 KV switchgear system is categorized as medium voltage switchgear or MV switchgear. These switchgears are of many types. They may metal enclosed indoor type, metal enclosed outdoor type, outdoor type without metal enclosure, etc. The interruption medium of this switchgear may be oil, SF and vacuum. The main requirement of MV power network is to interrupt current during faulty condition irrespective of what type of CB is used in the MV switchgear system. Although it may be capable of functioning in other conditions also. A medium voltage switchgear, should be capable of, MV PANEL SPECIFICATION AS PER CUSTOMER REQUIREMENTS LOAD BANK Performance testing of any equipment is very crucial step ensuring that it would function very efficiently without breakdown when the actual load is used. The importance of this test OS slowly being realized in different sectors of the electrical and power electronic industry and is on its way to becoming mandatory norm for erection, commissioning and maintenance of electrical equipment’s. These load bank has been employed as dummy loads to energy generators to keep voltage regulation in check. Load bank is a device which develops an electrical load, applies the load to an electrical power source and converters or dissipates the resultant power output of the source. SPECIFICATION AS PER CUSTOMER REQUIREMENTS
  35. 35. Programmable Logic Controllers (PLCs) are small industrial computers with modular components designed to automate customized control processes. PLCs are often used in factories and industrial plants to control motors, pumps, lights, fans, circuit breakers and other machinery. Integrated PLC Panel can monitor any process and provide data wherever and however you need it. There are many components to a PLC, but most of them can be put in the following three categories: • Processor (CPU) • Inputs • Outputs PLCs are complex and powerful computers; it takes inputs, performs logic on the inputs in the CPU and then turns on or off outputs based on that logic. We can take the following case for example: 1. The CPU monitors the status of the inputs (for example, proximity sensor off, valve 40% open, etc.) 2. The CPU takes the information that it gets from the inputs and performs logic on the inputs 3. The CPU operates the outputs based on the logic (for example, turn off motor, open valve, etc.) PLC PANEL SPECIFICATION AS PER CUSTOMER REQUIREMENTS
  36. 36. What is VFD Panel? Variable frequency drive control panel (also named VFD panel, AC drive electrical control panel) is consisted of inner VFD inside the cabinet with external control, protect, display and other electrical, it's an frequency conversion device to control three phase AC motor (including fans and pumps) in variable speed to save energy. Why we use VFD Panels? 1, Power switching and protection VFD panels are designed with a circuit breaker usually, which are connected to the input line power supply to switch the panel on/off, and provide protection when short circuit or overload occurs in the circuits and variable speed drives. In addition, VFD panels can disconnect power to ensure operator's safety during motor maintenance. 2, Adjustable speed A frequency control potentiometer is installed on the VFD panel's door, to transmit command signals to the motor according to operator assigned. VFD panel has mains switching function to ensure the system continues operation in case of the variable frequency drive failed. 3, Visual control VFD panel has display and operation panel on the front body, which is connected to the electrical components inside the control cabinet. It can display the panel's operational status visually, and convenient for operator control the motor in actual field operations. Manufacturers also equip with a variety of instruments and indicators inside the variable frequency drive panels, such as voltmeter, ammeter, frequency meter, and power indicator light, alarm lights, running lights, power frequency lights etc., which will monitor the VFD control panels working status in real time. 4, Security protection Include variable frequency drive, all other electrical components are integrated inside the VFD panel, thus reducing the impact of external environment to the electrical components, and ensure the operator safety level like reducing shock hazard rate, so it has a better safety protection function. Typical applications: water supply, air compressors, central air conditioning, port machinery, machine tools, boilers, paper machinery, food machinery and so on. VFD CONTROL PANEL SPECIFICATION AS PER CUSTOMER REQUIREMENTS
  37. 37. Supervisory Control and Data Acquisition (SCADA) systems are robust industrial control systems that allow multiple users to monitor and control an unlimited number of processes from multiple locations throughout your facility. The key advantage to SCADA controlled systems is that the controlling software is located at a single, central location. All the users access the system through a basic internet web browsing program. Hydro-Flo SCADA systems are a reasonable-cost alternative to operating and maintaining multiple systems throughout your facility. Managing and maintaining a SCADA system is much less cumbersome than trying to keep multiple systems updated. A SQL database (common throughout most network systems) stores all the data in a single location. Your IT staff will find system updates fast and simple. A Hydro-Flo SCADA system will make your overall operation more efficient, and less prone to operating system errors. SCADA Control Panel Systems SPECIFICATION AS PER CUSTOMER REQUIREMENTS Most modern control systems employ a PLC (Programmable Logic Controller) as a means to control motors, pumps, valves and various other equipment used in a process. Computer based HMI (Human Machine Interface) products provide the means by which process personnel interact with the PLC control system. A well designed combination of PLC’s and HMI’s can be a solid foundation for your process automation needs. Van Ert Electric blends the right components with customized design to build quality automation solutions. Our goal is to provide efficient, well documented programs that blend well with existing system logic and maintenance personnel expertise. Our extensive system control history and knowledge of current development platforms allows us to provide proven technologies that can improve your process efficiencies PLC & HMI Panels SPECIFICATION AS PER CUSTOMER REQUIREMENTS
  38. 38. BETA is an Energy Efficiency Technology Company that Consults, designs, automate and manufacture to utilize energy optimization techniques and savings energy for industries, Commercial and Residential buildings. The company was founded to focus on optimizing Energy losses and resolving the issues of weak power transmissions to create a better solution in Energy Efficiency. EMPORES is dedicated to the research of Electrical Efficiency, suppression of energy losses and improve Energy savings. ENERGY SAVING EQUIPMENT BETA Combines Machine learning (ML), Embedded Artificial intelligence (AI) and impedance matching technique in which the Maximum power is transferred from a source to load when the load resistance matches the internal resistance of the source. The system is high advanced and sophisticated that are equipped with State of the Art Control systems that has monitoring, measuring and reporting techniques. Each System is carefully calibrated according to the electrical equipment and load profile of the client. In BETA addition to allowing considerable energy savings, this also guarantees safe and protected operation and a longer service life for both the system and the connected equipment. All power transferring devices, including transformers, have inherent impedance with resistive, inductive or capacitive components. The resistive component is of particular importance in energy efficiency because it causes a power loss (I2R). In the power loss is less than 0.3%, contributing to the overall reduction of energy costs. Electrical feeders cause a power loss due to the resistive component of their impedance, and this power consumption is increased when the line and load impedances are not matched. Being positioned between the feeder line and the load, BETA units are capable of providing impedance matching, dynamic control and equipment protection which reduces resistive losses and conserves energy, optimizing the delivery of electrical power to the user’s equipment. TECHNOLOGY
  39. 39. BENEFITS BETA does not have any moving parts, which means that none of its components will suffer mechanical wear over time. This eliminates maintenance costs and ensures a long service life of more than 20 years. The Advanced Design of BETA has been able to achieve an efficiency of more than 99.3% at both full-load and part-load conditions. This high efficiency is not achievable with regular step down transformers, where it is affected negatively during part-load operation. Few Autotransformers or voltage management transformers are implemented only with the goal of saving energy, without considering the presence of transient phenomena in the electric supply. BETA transformer design has a unique winding configuration that provides additional benefits such as power quality, phase balancing, protection against transients and mitigation of harmonics. This device protects your electrical installation completely and provides a risk-free electrical power supply. Each device is manufactured according to the needs and requirements of the customer, considering the specific electrical issues at each facility. We have an individual approach to our customers, considering in each case the electrical devices owned, type of operation and load characteristics. This allows us to calculate with great precision, the potential energy savings and the reduction in power consumption. We have clear and established procedures, technological expertise and very attractive return on your investment. COMMERCIAL POWER OPTIMIZER WITH AUTOMATED DEMAND RESPONSE
  40. 40. SOLAR PROJECT Working principle The whole system comprises of Solar PV Modules, Inverters, Mounting Structures, Transformers, LV/MV/EHV switchgears & other vital components. The Solar PV Modules generates DC electricity in proportion to the amount of sunlight available, generating the most power on a clear day when the sun is at a normal angle to the Solar PV Modules. These Solar PV Modules are connected in series and parallel to form a Solar Array. Sri Lanka Project
  41. 41. 4/305, Bodipalayam, Mother India Industrial Land, Madukkarai Via, Coimbatore -641 105, Tamilnadu, India. GST : 33AAIFB6031E1ZZ | IEC : 3214002252 +91 422 296 1101 | +91 9092 987 744 | +91 8754 860 606 Email: betaservo@gmail.com | info@servostabliser.com Website: www.servostabliser.com | www.betapower.in Thank You

×