2010 Electrical And Data Presentation

  1. 1. USA Ele ct r ica l & D a t a Solu t ion s UL Approved US cabling solutions for Ahrend Ahrend Ltd. - 27 november 2009 1
  2. 2. A5 0 0 D e sk in g Ca ble M a n a ge m e n t Solu t ion s A500 Cable Clamps Plastic colour 27 soft black, allow wires to be run along the beam. Guiding and securing surplus Data wires and user wires for a clean wiring solution. These clamps are also used to install the S2 Metal and Plastic Panels that are used for modesty and privacy in the A500 Desking solution. Ahrend Ltd. - 27 november 2009 2
  3. 3. A5 0 0 D e sk in g Ca ble M a n a ge m e n t Solu t ion s A500 Cable Trays Metal Trays, allow wires to be hidden & secured in the housing that opens to allow the user to access and maintain the desks wiring needs. Chargers, phones and computer cables are managed neatly. We do not run power in these trays as they are not to UL code. This is a neater solution for wire management Ahrend Ltd. - 27 november 2009 3
  4. 4. Le g Cove r s Infeed entry through cover at base of leg Infeed exits through cover at top of leg For many types of legs – M e t a l le g cove r s cle a n ly br in gin g pow e r fr om t h e floor to the shared cable tray or A500 beam. Ahrend Ltd. - 27 november 2009 4
  5. 5. Ele ct r ica l Solut ion – 2 Cir cu it – Be a m clippe d Solut ion Ele ct r ica l Syst e m for A5 0 0 Desking and Benching solutions 4 wires 2 Circuits , 20 amps each (Circuit 1 & 2 Only) 13 Duplex receptacles per circuit maximum. 26-15 amps Duplex per Power Entry maximum. Easy to install and reconfigure. UL listed as a Manufactured Wiring system All Components come in optional Plastic flexible Conduit or Steel flexible Conduit Ahrend Ltd. - 27 november 2009 5
  6. 6. Electrical Solution – 4 Circuit – Ca ble t r a y M ou n t e d Solu t ion Used for Benching solution to provide shared power down the spine so both sides have access to electrical outlets. UL approved Panel based Byrne Electrical components allow us to install a more robust electrical solution for denser workstation environments. 8 Wires 4 circuits with Dedicated ground and NYC Code Infeeds for work in New York City. These components are mounted to the cable tray creating a Code compliant solution for the Bench. Ahrend Ltd. - 27 november 2009 6
  7. 7. A500 Benching – u se s Ca ble t r a ys t o se cu r e t h e sh a r e d e le ct r ica l solu t ion s w h ich m a k e s it UL a ppr ove d Standard 8”w Bench Cable Tray Extra Capacity 14”w Cable tray Ahrend Ltd. - 27 november 2009 7
  8. 8. A5 0 0 Be n ch in g Solu t ion – 8 ” t r a y Clamps off the beams secure the 8”tray at the center of bench for access to both sides for Electrical & Data solutions Ahrend Ltd. - 27 november 2009 8
  9. 9. A5 0 0 Be n ch in g Solu t ion – for 1 4 ” t r a y Ph ot os sh ow t h e m oun t ing of t h e 1 4 ” Ex t r a Ca pa cit y t r a y Ahrend Ltd. - 27 november 2009 9
  10. 10. A5 0 0 D a t a Sock e t Solu t ion A500 Data socket Housing for Data solution in a Data Accessory A Faceplate with an A500 beam clamp to attach socket to furniture No Wiring provided by Ahrend Wires and outlets by others Ahrend Ltd. - 27 november 2009 10
  11. 11. A5 0 0 D a t a Sock e t Solu t ion Data socket fixed to A500 beam Ahrend Ltd. - 27 november 2009 11
  12. 12. Ple a se con t a ct u s for m or e in for m a t ion Ahrend Sales Rep: Ingrid Narvaez Inarvaez@ahrend.com Ahrend Ltd. - 27 november 2009 12

×