Power & Cooling - Edwin Veltman

  1. 1. HP DUTCHWORLD 2008 OUTSMART THE FUTURE! Power and Cooling Edwin Veltman Critical Factility Services © 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice
  2. 2. Agenda • Power & Cooling in het Datacenter • Trends • Design Evolutie • Energie Impact • Efficiëntie Optimaliseren 11 December 2 2008
  3. 3. Trends
  4. 4. Datacenter Trends • 85% van de datacenters gebouwd voor 2001worden obsolete • Beschikbaarheids eisen • TCO druk • Prijs van servers versus power • Snellere Technologie wisselingen • Hogere power footprint “verBlading” • Energie efficiëntie, Milieu 11 December 4 2008
  5. 5. Datacenter economie verandert Prijs van de fysieke ruimte was primare in datacenter design De prijs van Power & Cooling heeft nu prioriteit Datacenter managers geven prioriteit aan investeren in efficiënte power & Cooling systemen voor een lagere Total Cost of Ownership (TCO) Belady, C., “In the Data Center, Power and Cooling Costs More than IT Equipment it Supports”, Electronics Cooling Magazine (Feb 2007) 11 December 5 2008
  6. 6. Design Evolutie
  7. 7. Next Generation Data Center (NGDC) • Flexibel, schaalbaar, aanpasbaar, modulair. Essentieel voor de dynamische technologie in het datacenter vandaag • Mogelijkheid om snel uit te rollen makkelijk te (her)configureren • In hoge mate geautomatiseerd en gevirtualiseerd • Power & Cooling efficiënt benut • Realtime uitgebreide monitoring • Nieuw geïntegreerde aanpak hardware, software, applicaties, netwerk en faciliteiten • “The Data Center is the Computer” 11 December 7 2008
  8. 8. Datacenter Design Trends • Metrics − Energie • PUE-Power Usage Effectiveness − Betrouwbaarheid • Betrouwbaarheid modeling speelt een cruciale rol in optimaliseren van performance/kost ratio − Beschikbaarheid • Tier level • Realistische modellen − Energie − CFD − Betrouwbaarheid − Kosten 11 December 8 2008
  9. 9. Business bepaalt balans Beschikbaarheid Risico Prijs 11 December 9 2008
  10. 10. Data Center Design Trends Voorbeeld; Datacenter 3 jaar geleden gebouwd 20.000 m2 Datacenter 10.000 m2 verhoogde vloer ruimte naast MEP infrastructuur ruimte. Design density 500 W/m2 op dag 1 Schaalbaar tot 1000W/m2. 11 December 10 2008
  11. 11. Datacenter Design Trends The Next Generation Data Center Model •Datacenter bouwstenen •Modulair •Designdensity 1 kW/m2 op dag 1 •Schaalbaar tot >2 kW/m2 •Rack belastingen >20kW 11 December 11 2008
  12. 12. HP Perfomance Optimzed Data Center POD PUE <1.25 20 kW/m2 600kW+ Capaciteit 6 weken “order to ship” Power density Geographic Flexibility Maximum Security IT Flexibility Max Redundancy Energy Efficiency Speed of deployment Brick-and-mortar Container
  13. 13. HP POD Interieur Serviceable high efficiency, variable speed Serviceable high blowers from HP efficiency heat MCS exchangers (HEX) from HP MCS Separate Utility module segregate IT/UPS security access and Standard 50U environmentals racks Hot aisle with Facilities rear access management on through doors in exterior of cold the container aisle 92cm cold aisle Temperatuur >32C 11 December 13 2008
  14. 14. Datacenter Design Trends LEED ® Aanpak • Meeting with clients whose mission requires a high level of operational continuity and performance from their facilities. • Providing LEED® consulting, energy modeling, design and services on LEED ® Platinum, Gold, Silver and Certified facilities. Together with Lawrence Berkeley National Laboratory, focusing on 4 identified areas to reduce energy consumption: • Optimize existing data centers through proper airflow distribution and supply air temperatures. • In new facilities, use different cooling/ventilation alternatives to reduce energy consumption of the HVAC systems by up to 30%. • Use DC power distribution to increase reliability and reduce energy consumption of the UPS/electrical distribution by approximately 25% and to also improve both energy performance and space efficiency. • In new or existing facilities, use on-site power generation to decrease capital expenditures, increase reliability, and significantly reduce utility costs. LEED ® Leadership in Energy and Environmental Design 11 December 14 2008
  15. 15. Energie Impact
  16. 16. Vroeg plannen voor het beste resultaat 11 December 16 2008
  17. 17. Primair Energie voorziening 11 December 17 2008
  18. 18. Power Usage Effectiveness (PUE) Utility Transformer Total Data House Emergency Power = Center Power (+) power Main Generator (kW) (kW) Main Service IT Power Power Power House Misc. Power Mech. Total Data = In (+) (+) Center Power (kW) PP- Gen Lighting UPS House Service Panel Mech. Swgear panels STS Generator Lighting, Block Exit Lights, PDUs Heaters & BMS, EPMS Lighting & Security DATA CENTER CRAC Units, AHUs, RPPs Chillers & Dry Coolers Power To IT Misc. Support IT- Critical load Mech. Support Data Center Data Center Power Usage Effectiveness (PUE) = Total Data Center Power (kW) Total IT Power (kW) 11 December 18 2008
  19. 19. Datacenter Performance Totaal energie verbruik 3 MW, PUE=2.06 Data center Average Power Consumption 1600 1505 1400 1200 1000 771 kW 800 600 374 400 195 200 83 79 22 50 8 9 0 Cooling DC Fans Humidification Other Mech Fuel IT Adjusted UPS Losses Generator Lights Other Elec Heater Cooling Systems Electrical and Building Systems 11 December 19 2008
  20. 20. Electrisch Systeem Performance • High efficiency UPS systemen benaderen 99% − Econo-mode − MV UPS systemen (3.6kV to 24kV) − Batterijloos load-interactive vliegwiel systemen • High efficiency transformeren • DC versus AC power distributie 11 December 20 2008
  21. 21. HP Power Distribution Rack met HP Rackmount Parallel UPS • Power distributie waar en wanneer het nodig is. • Redundantie en schaalbaar power • Incremental investering in facilities 220-240V 1Ø of 380-415 3Ø naar racks UPS PDR PDR UPS Voeding A Voeding B 11 December 21 2008
  22. 22. Koel Systeem Performance Verhoogde Hot and Cold Aisle Temperatuur • Verruimde omgeving condities van ASHRAE: The previous and 2008 recommended envelope data 2004 Version 2008 Version Low End Temperature 20°C (68 °F) 18°C (64.4°F) High End Temperature 25°C (77 °F) 27°C (80.6°F) Low End Moisture 40% RH 30% RH & 5.5°C DP (41.9°F) High End Moisture 55% RH 60% RH & 15°C DP (59°F) − Server inlaat temperatuur tot 27°C • Voordelen − Meer uren vrije koeling − Verhoogd CRAC en Chiller efficiëntie 11 December 22 2008
  23. 23. Koel Systeem Performance • Datacenter Best practices • Hot / Cold aisles • Containment (betere scheiding tussen warm en koud) • Verwijderen van warme lucht • Minimaliseren lucht recirculatie en bypass lucht • Verhoogde vloer optimaliseren • Airflow management • Watergekoelde racks 11 December 23 2008
  24. 24. HP Modular Cooling System (MCS) • Koeling voor High density systemen • 2x17,5kW of 35 kW aan koelvermogen in een rack • Minimale beïnvloeding van het datacenter • Modulaire oplossing • Uniforme horizontale airflow over het gehele rack. • Geen onderbreking van airflow als deuren open zijn. • Consequente scheiding tussen servers en koel unit.
  25. 25. Efficiëntie Optimaliseren
  26. 26. Stappen naar een energie efficient datacenter 0. Efficiënte componenten, systemen technieken – Virtualisatie – Power saving technieken 1. Toepassen van Best Practices 2. Uitvoeren van Thermal Modeling 3. Implementeren van monitoring en Smart Cooling concepten
  27. 27. Power and cooling analyse HP portfolio Thermal Assessments Thermal Quick Assessment is Quick Assessment Quick Analysis gebaseerd op interviews met IT en Intermediate Analysis Comprehensive Analysis facilitair management, HP’s observaties in het datacenter. Deze dienst levert een rapportage met “quick wins” en lange termijn aanbevelingen , een gap analyse en een capaciteit overzicht van e fysieke power en cooling infrastructuur. • Cooling load vs. capaciteit • Data collectie, 3D simulatie • Airflow management onder en boven de • Lucht recirculatie Thermal Comprehensive verhoogde vloer Assessment is een uitbreiding op Data analyse • Rack best practices • het Quick Assessment met • Airflow obstructies • Scenario modeling opties Computational Fluid Dynamics • Rij oriëntatie/plaatsing (CFD) modeling, inzichtelijk maken • Comprehensive analyse en van de thermische eigenschappen uitgebreid rapport en • Gap analyse van een datacenter. Toetst de aanbevelingen • Infrastructuur management robuustheid en simuleert “worste • Thermal ZONE mapping case” scenario's.
  28. 28. Thermal Zone Mapping Computational Fluid Dynamics Optimaal de business faciliteren Quantificeren van overlappende gebieden Bronze – Area covered by one CRAC unit only (no overlapping) • Gebieden waarbij 3 of meer CRAC units invloed hebben, zijn geclassificeerd als “Goldquot; – Deze Silver – Area covered by at least two CRAC units gebieden zijn typisch bestemd voor het plaatsen van de meest business kritische applicaties. Gold – Area covered by three CRAC units or more • Gebieden zonder redundantie hebben een hoger risico CRAC 3 CRAC 1 CRAC 2 Cooling Redundancy Category Room Area Coverage Bronze 21.5% O1 O0 Silver 53.4% O3 O2 RW RW O4 RW RW RW Gold 25.1% Total Overlapping Area (more than 2 CRAC units 78.5% overlapping) CRAC 4 CRAC 5 CRAC 6
  29. 29. Aanvullende informatie • www.hp.com/go/dct • www.hp.com/go/btc • www.hp.com/go/powerandcooling • www.hp.com/go/mcs • www.hp.com/go/pod • www.hpl.hp.com • hp.feedroom.com (Tip: zoek “Patel”) • www.thegreengrid.org • www.upsite.com • tc99.ashraetcs.org 11 December 29 2008
  30. 30. Contact informatie • Critical Facility Services • Sales: rutger.diepeveen@hp.com • Consultant: edwin.veltman@hp.com • Consultant: jaco.pronk@hp.com 11 December 30 2008
  31. 31. Technology for better business outcomes

×