Successfully reported this slideshow.

EMS 12-Lead Transmission Solution

1,026 views

Published on

Published in: Business
  • Be the first to comment

  • Be the first to like this

EMS 12-Lead Transmission Solution

  1. 1. <ul><li>EMS 12-Lead Transmission Solution </li></ul><ul><ul><li>Rosetta </li></ul></ul><ul><ul><ul><li>Data Translators </li></ul></ul></ul><ul><ul><li>CAREpoint </li></ul></ul><ul><ul><li>EMS Workstation </li></ul></ul>
  2. 2. Who Is GD? Since 1979 <ul><li>General Devices, a leader in advanced Telemedicine and Communications products for Emergency Medical Services, Emergency Departments and Public Safety, providing solutions for voice, telemetry, patient care information and interoperability via radio, cellular, and landline. </li></ul><ul><li>GD is a FDA registered manufacturer. </li></ul><ul><li>         </li></ul>
  3. 3. What is Rosetta? <ul><li>The Rosetta™ Family - The Key to Reliable Communications </li></ul><ul><li>The &quot;Rosetta™&quot; family of communications products developed by General Devices help to solve the dilemma of EMS being locked into imperfect communications mediums, be it cellular, UHF/VHF/800 Radio or landline telephone. With Rosetta™ you can utilize the best communications means available for each situation. When the need is critical, count on ROSETTA™ to get the information through! </li></ul>Definition : rosetta o-,zet-e- : 1) A stone that deciphered ancient Egyptian hieroglyphs. 2) A unique device that translates medical information from one communications medium to another (as in translating from digital cellular to UHF radio or analog cellular).
  4. 4. Rosetta System Components <ul><li>Rosetta-Lt Rosetta-Rx CAREpoint </li></ul><ul><li>Ambulance Hospital (print only) Hospital (full solution) </li></ul>
  5. 5. Rosetta-Lt Field (EMS) Side <ul><li>Creates a “portable” 12-lead </li></ul><ul><ul><li>Transmit from where you want </li></ul></ul><ul><li>No need for monthly cellular/data service </li></ul><ul><ul><li>Use your existing radio system </li></ul></ul><ul><li>Meets requirements for single lead </li></ul><ul><ul><li>Sends standard ECG strips </li></ul></ul><ul><li>Cable connection to most radios </li></ul><ul><ul><li>Keys the radio for you </li></ul></ul><ul><ul><li>Frees up your hands </li></ul></ul>Receives digital 12 lead files from compatible monitors and “translates” to a format for transmission by radio or certain cell phones…
  6. 6. Rosetta-Lt Monitor Compatibility <ul><li>Compatible with: </li></ul><ul><li>MRx </li></ul><ul><li> LP12 </li></ul><ul><li>M & E-Series </li></ul><ul><li>Data Types: </li></ul><ul><li>Single Lead </li></ul><ul><li>12-Lead Reports </li></ul><ul><li>Vitals (MRx only) </li></ul>
  7. 7. Rosetta-Lt Communications Compatibility <ul><li>Transmit Single & 12 Lead ECG Using: </li></ul><ul><li>2-Way Radio </li></ul><ul><ul><li>VHF Cable Connection ( recommended ) </li></ul></ul><ul><ul><li>UHF or Acoustic Couple </li></ul></ul><ul><ul><li>800 (analog) Transmits in just over 1 minute! </li></ul></ul><ul><ul><li>Automatic PTT </li></ul></ul><ul><li>Cellular </li></ul><ul><ul><li>Analog </li></ul></ul><ul><ul><li>Nextel, Cingular (GSM)* </li></ul></ul><ul><ul><ul><li>* Waveform Only </li></ul></ul></ul><ul><li>Landline </li></ul><ul><li>Rosetta-Lt can transmit virtually over any analog voice channel </li></ul>
  8. 8. Rosetta-Lt Communications What Does NOT Work? <ul><li>Trunked radio systems with digital only voice </li></ul><ul><li>Some newer trunk systems are set up for digital only (even though they are likely capable of both analog & digital voice). Rosetta can not transmit on these systems. It does however work on trunk radio with analog voice channels/talk groups. </li></ul><ul><li>Digital Cellular Limitations </li></ul><ul><li>Rosetta works well over analog cellular but that coverage is on the way out. Rosetta does transmit the waveform portion of the report well over iDEN (Nextel) & GSM cellular (Cingular, etc) Reception of the text info & interpretations is not guaranteed! </li></ul><ul><li>Rosetta does NOT work on CDMA cellular systems (Verizon). </li></ul><ul><li>Use of the Rosetta-Cell headset jack cable is recommended. </li></ul><ul><li>Contact General Devices for verify your systems compatibility. </li></ul>Rosetta-Lt is very versatile, but there are limitations:
  9. 9. Rosetta-Rx Hospital Side (basic print-out only solution) <ul><li>Data: </li></ul><ul><li>Single Lead </li></ul><ul><li>12-Lead Reports </li></ul><ul><li>Communications (Input): </li></ul><ul><li>2-Way Radio (receive pair) </li></ul><ul><li>Phone line ( GSM Cell, Landline ) </li></ul><ul><li>Printing (Output): </li></ul><ul><li>HP LaserJet (or compatible) printer with “parallel port” </li></ul><ul><li>Fully Automatic Operation </li></ul>
  10. 10. CAREpoint Hospital Side Full Solution! <ul><li>ECG Display </li></ul><ul><li>Printing </li></ul><ul><ul><li>Local printer </li></ul></ul><ul><ul><li>Network printers -Cath. lab, etc. </li></ul></ul><ul><li>Forwarding </li></ul><ul><ul><li>Fax </li></ul></ul><ul><ul><li>e-mail </li></ul></ul><ul><ul><li>PDA </li></ul></ul><ul><li>Documentation (storage) </li></ul><ul><ul><li>QA Review from office </li></ul></ul><ul><ul><li>D-Scribe Digital Recorder </li></ul></ul><ul><ul><ul><li>Voice and data </li></ul></ul></ul>
  11. 11. CAREpoint EMS Workstation <ul><li>Communications </li></ul><ul><ul><li>Voice & Data </li></ul></ul><ul><ul><li>Radio Landline & Cellular </li></ul></ul><ul><li>Information </li></ul><ul><ul><li>InfoManager –Protocols, etc </li></ul></ul><ul><ul><li>Single & 12 Lead ECG </li></ul></ul><ul><li>Documentation </li></ul><ul><ul><li>D-Scribe Digital Recorder </li></ul></ul><ul><ul><li>Networked – Remote Access </li></ul></ul><ul><li>Telemedicine Ready </li></ul><ul><ul><li>e-Bridge platform </li></ul></ul><ul><ul><li>Voice * Video * Data * e-PCR * 12L </li></ul></ul><ul><li>300+ Currently Installed </li></ul>
  12. 12. CAREpoint In Action….
  13. 13. Keys to Rosetta’s Success <ul><li>Ease Of Use </li></ul><ul><li>Rugged / Robust </li></ul><ul><li>Integrated </li></ul><ul><li>Interoperable </li></ul><ul><li>Physician / Paramedic Acceptance </li></ul>
  14. 14. Tell Me More! <ul><li>How does it work? </li></ul><ul><li>What does it cost? </li></ul><ul><li>Who do we contact? </li></ul>
  15. 15. How does it work? 12-Lead Data Flow… Monitor Cable (RS-232) Radio Cable (Audio / PTT) VHF UHF 800 Trunked GSM Phone
  16. 16. How does it work? - Alternate Method Fax from monitor company system 12-Lead Data Flow… CAREpoint EMS Workstations Display – Print - Forward IP Cellular Forward to Hosp. Fax, e-mail Monitor’s Receiving Station Auto-FAX
  17. 17. What Does it cost? <ul><li>Rosetta-Lt </li></ul><ul><li>$800 </li></ul><ul><li>+ </li></ul><ul><li>Cables </li></ul>Rosetta-Rx $2000 + Printer CAREpoint 20 -30K (config/options)
  18. 18. Sampling of GD’s Hundreds of Customers… <ul><li>Richland County - SC </li></ul><ul><li>Baptist Health - AL </li></ul><ul><li>Wellmont Healthcare - TN </li></ul><ul><li>Loma Linda University Med. Cntr. CA </li></ul><ul><li>New York City FD EMS - FDNY </li></ul><ul><li>Spartanburg Regional EMS - SC </li></ul><ul><li>University of Chicago - IL </li></ul><ul><li>Cook County Hosp - IL </li></ul><ul><li>New York Presbyterian – NY </li></ul><ul><li>Ocean City EMS </li></ul><ul><li>Anne Arundel County FD </li></ul><ul><li>Tucson FD-EMS - AZ </li></ul><ul><li>Milwaukee County EMS -WI </li></ul>
  19. 19. Need More Information? <ul><li>Refer to the Rosetta Product Description document available on the GD web site. </li></ul><ul><li>Contact: </li></ul><ul><li>General Devices </li></ul><ul><li>Sales Department </li></ul><ul><li>201.313.7075 </li></ul><ul><li>[email_address] </li></ul><ul><li>www.general-devices.com </li></ul>

×