Control Panel VIDEOFIED ® XL GPRS                                       TECHNICAL                               SPECIFICAT...
Control Panel VIDEOFIED® XL GPRS                                                                                          ...
Upcoming SlideShare
Loading in …5
×

00 control panel videofied xl gprs specification sheet

952 views

Published on

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
952
On SlideShare
0
From Embeds
0
Number of Embeds
3
Actions
Shares
0
Downloads
1
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

00 control panel videofied xl gprs specification sheet

  1. 1. Control Panel VIDEOFIED ® XL GPRS TECHNICAL SPECIFICATIO NS Control Panel VIDEOFIED® XL GPRSElectrical Data Physical Data P R O D U C T S P E C I F I C A T I O N S S H E E TPower requirements Eight 1.5V batteries Material ABS—ULV0 Made by RSI VIDEO TECHNOLOGIES 2200-XL-GPRS June 2009Battery type Alkaline, D size, LR20 Dimensions 225 mm x 180 mm x 55mmBattery life 4 years (LxWxD):9in. x 7in. x 2-1/6in. Description Supervised Wireless TechnologyRF technology S2View® Weight 520gr (without batteries) / 1600gr (with batteries)Radio type Spread Spectrum Bidirectional RF The Control Panel Model XL GPRS is a VIDEOFIED® The XL GPRS, along with all VIDEOFIED® devices utilizeOperating frequency 868/915/920 MHz wireless, battery operated security system control panel. patented S2View® - Spread Spectrum, VIDEOFIED®, Interactive,Transmission security AES algorithm encryption Installation/Mounting The control panel is designed for residential and small AES Encrypted Wireless technology, providing optimum signalRadio jam detection Yes Control Panel/Base One screw secures control panel cover commercial security applications where video verification integrity and security. Bi-directional RF communication pathsSupervision Yes to base; four screws secure is needed or desired. between all system devices and the system control panelAntenna Integrated control panel base to the wall assure high signal reliability. The control panel is powered by eight 1.5-volt alkalineTamper detection Wall and cover tamper detection Integrated antennas eliminate protruding wires or rods batteries that last up to four years, with normal systemSiren output 105 dB @ 1 meter cumbersome to install and unsightly to activity. A built-in siren provides status beeps. The embeddedSiren duration programmable, 3 minutes maximum consumers, and if damaged could lead to potential cell modem communicator reports to the monitoring stationProgramming Alphanumeric Keypads or Embedded touchpad Data system communication problems. and and enables 2-way voice communication over cell to the Frontel remote control Software TouchPad to arm/disarm the system with event display monitoring station. The panel supervises every device (excluding the remoteDevices per system 19 per system Automatic back light keyfob) to validate current open/close state, tamper condition,Access codes 20 maximum 3 arming keys / symbols A dual-tamper function is active 24 hours, whether or not serial number, date of manufacture, firmware revision, andInstaller codes One (for system programming only) 3 panic buttons the system is armed. An alarm occurs if the control panel battery status..Security levels 3 Event symbols cover is removed, or if the control panel is removed fromArming modes : 2 Embedded voice speaker and microphone the mounting surface.Special arming modes 4 (Area 1 predefined from factory for No specification mentioned on Proximity Card arming/disarming With the embedded touchpad the user can arm, disarm the entry/exit delay. Areas 2, 3, & 4 programmable.) system and review past events and system status. Under theCommunication formats Voice, Email or IPCommunicator type GPRS and GSM cell TouchPad an integrated proximity card reader that can be used2 way-voice Full duplex, bi-directional to arm and disarm the system without using the TouchPad.Dialing DTMF The proximity card/tag arming system is designed to maximizeProtocols Frontel operator convenience.IP stack IP, TCP/IP, HTTP, SMTP, PPPVoice alarm transmission Up to 3 phone numbersVoice server Pre-recorded messagesRemote maintenance Frontel Downloader protocol onlyVIdeo transmission: By Frontel protocol to central monitoring stationVideo format MPEG V1.0 video fileVideo file size 220 KbytesVideo framing 5 frames/secondImage format JPEGImage size 320 x 240 pixelsHistory/Event Log 4,000 events stored in flash memoryOperating temperature 0°/+40°C (32°/104°F)Maximum relative humidity 70%, non-condensingApprovals CE / EN50131 / EN300220 / INCERT / IDA / NCP (Europe) CP-01 / UL / FCC (USA) A-Tick (Australia) North American Headquarters EMEA SALES 2, rue Alexis de Tocqueville 4455 White Bear Parkway, Suite 700 92160 ANTONY White Bear Lake, MN 55110 FRANCE USA Phone +33 (0)1 55 59 10 25 Phone 877-206-5800 Fax +33 (0)3 90 20 66 36 Fax 651-762-4693 www.videofied.com www.videofied.com © 2009 RSI VIDEO TECHNOLOGIES. VIDEOFIED® is a Registered Trademark of RSI VIDEO TECHNOLOGIES. S2View ® is a registered trademark of RSI VIDEO TECHNOLOGIES. Specifications subject to change without notice.
  2. 2. Control Panel VIDEOFIED® XL GPRS TECHNICAL SPECIFICATIO NSCompatibility The XL GPRS works with all the following VIDEOFIED® wireless devices: Configuration/Programming History/Event Log The XL GPRS records and stores all system activities and Complete system configuration/programming can be done events (armings, disarmings, alarms, access codes entered, on-site using alphanumeric keypads. Easy to understand text systemprogramming changes, etc.) in flash memory, that on a two line, 16-characters liquid-crystal (LCD) display guides cannot be cleared or erased. The log accumulates a maximum you through programming, prompting you for simple yes/no or 4,000 events. data entry responses. Complete punctuation symbols allow for accurate website/IP address entries and device location naming. As additional events occur, the control panel automatically deletes the oldest event. This ensures the most recent events Off-site programming is accomplished by using Frontel reside in the log. Downloader Software. An IP connection between the control panel and a computer with Frontel Downloader The history/event log can be viewed using the embedded Software allows trained operators to configure/program touchpad, an alphanumeric keypad or downloaded at the system settings/parameters. central station.Indoor MotionViewerTM Prox-Tags - allow arming and Door Contacts - detect door Outdoor MotionViewerTM- integrated PIR motion desarming the system. and window open/close activity. - integrated PIR motion Features Communicationdetector, night vision digital An external input allows a wired detector, night vision digital The XL GPRS reports alarms and other system events using the > S2View® - Spread Spectrum, VIDEOFIED®, Interactivecamera, infrared illuminators. connection from standard camera, infrared illuminators. following methods and formats : Frontel and Voice. AES Encrypted Wireless technology provides optimumMotionViewers detect intruders security switches and MotionViewers detect intruders signal integrity and security.and capture a 10 second video detection devices outputs. and capture a 10 second video of > Frontel - provides complete system reporting informationof the intrusion which is sent to the intrusion which is sent to the and video verification to a central monitoring station set > Compatibility - works with all VIDEOFIED® wireless devices.the panel over RF. panel over RF. up with Frontel Monitoring Software. > Supervision of all devices (except remote keyfob). > Voice - reports alarms by digital voice to one, two, > Tamper detection - 24-hour dual-tamper function provides or three customer-designated phone numbers (office, detection for both cover and wall removal. Control panel home, cellular, etc.). also monitors all system device tamper switches. > Zones / Devices - 19 maximum. Voice Verification > Areas - 4 maximum. Area 1 predefined from factory for entry/exit delay. Areas 2, 3, and 4 can be configured The panel incorporates a speaker and a microphone. When as needed. using a GSM/GPRS simcard, the XL GPRS panel allows the monitoring station to do 2-way voice verification. 2-way voice > Access codes - 20 maximum, 4 - 6 digits; one installer Interior Sirens - provide status Exterior Sirens/Strobes - Smoke Sensor - enhances Remote Keyfobs - allow can be launched at any time when the panel is connected to access code for on-site programming only. beeps and alarm sounds provide alarm sounds and protection and uses advanced limited system operation the monitoring station. During the 2 way voice, data connection > Configuration/Programming - on-site using alphanumeric throughout the premises where visual identification of alarm detection technology. The and panic alarm and video download is suspended and resumes after the voice keypads or off-site using Frontel control remote Software. needed. site for responding authorities. Smoke Sensor is totally wireless capability in a portable, communication terminates. and an integrated addition the convenient package. > Communication - reports to central monitoring stations whole security system. using Frontel. Video Verification > Video Verification - video resolution of 320 x 240 pixels, Capacities Incorporating MotionViewers into the security system allows 0 lux sensitivity, 5-frames per second for approx. 10 seconds for video verification of intrusion alarms. When the system is total recording time. 220K MPEG file. Each XL GPRS system can manage up to 19 individual devices There are 20 individual access codes that can be four to six armed and an intruder trips MotionViewerTM, the integrated (MotionViewerTM, keypad, siren, etc.). Each device is assigned digits long. Each access code can be assigned to one of three > History/Event Log - maximum 4,000 events stored in flash camera captures a 10-second digital video clip which is sent to to one of four protection areas. Area 1 is predefined from the security levels for specific operating authority. Levels 1 and 3 memory that cannot be cleared or erased. the central monitoring station by the control panel, which can factory for delayed entry/exit. The other three areas can be provide various system operation limits. One installer code forward them to an alert list. configured/programmed as required for the installation. For allows access to Level 4 which provides the installer/dealer full example, Area 2 could be configured for devices on the main access for configuration/programming. The installer code is level, Area 3 for devices on the upper level, and Area 4 for restricted from system arming and disarming. devices in the basement.

×