Water Saturation
ππ€ = (
π Γ π π€
π π‘ Γ ππ)
1/π
= (
0.81 Γ 0.066
47.38 Γ 0.242552)0.5
= ππ. πππ %
a = 0.81
m = 2
n = 2
π π€ = 0.066 ohm m
RESERVOIR INTERVAL: 10362-11160 ft
πβ = 1 β ππ€ = 1 β 0.13848 = π. πππππ ππ ππ. πππ %
Sh > 60 %, it is considered as pay zone for the well.
Negative hydrocarbon saturation values show
water bearing formations.