Scanning tunneling microscope.pptx

• The scanning tunneling Microscope is an electron microscope that transmits three - dimensional images of the electron cloud around the nucleus.
• The scanning tunneling Microscope (STM) works by scanning a very sharp metal wire tip over a surface. By bringing the tip very close to the surface, and by applying an electrical voltage to the tip or sample, we can image the surface at an extremely small scale - down to resolving individual atoms.

• The scanning tunneling Microscope is an electron microscope that transmits three - dimensional images of the electron cloud around the nucleus.
• The scanning tunneling Microscope (STM) works by scanning a very sharp metal wire tip over a surface. By bringing the tip very close to the surface, and by applying an electrical voltage to the tip or sample, we can image the surface at an extremely small scale - down to resolving individual atoms.

Advertisement
Advertisement

More Related Content

Similar to Scanning tunneling microscope.pptx (20)

More from Aliya Fathima Ilyas (20)

Advertisement

Recently uploaded (20)

Scanning tunneling microscope.pptx

  1. 1. STM
  2. 2. SCANNING TUNNELING MICROSCOPE  The development of the family of scanning probe microscopes started with the original invention of the STM in 1981.  Gerd Binnig & Heinrich Rohrer developed the first working STM while working at IBM Zurich Research Laboratories in Switzerland. This instrument would later win Binnig and Rohrer the Nobel prize in physics in 1986.  The scanning tunneling Microscope is an electron microscope that transmits three - dimensional images of the electron cloud around the nucleus.  The scanning tunneling Microscope (STM) works by scanning a very sharp metal wire tip over a surface. By bringing the tip very close to the surface, and by applying an electrical voltage to the tip or sample, we can image the surface at an extremely small scale - down to resolving individual atoms.  The STM allows the inspection of the properties of a conductive solid surface at an atomic size.
  3. 3. The main components of STM include Scanning tip, Piezoelectric scanner, Distance control and scanning unit, Vibration isolation system and Data processing unit (Computer).  SCANNING TIP - STM tips are usually made from Tungsten metal or platinum - iridium alloy where at the very end of the tip (called apex) there is one atom of the material. Scanning tip is the most important aspect of the STM as tunneling current is carried by that particular atom.  DISTANCE CONTROL & SCANNING UNIT - Position control using piezoelectric means is extremely fine, so a coarse control is needed to position the tip close enough to the sample before the piezoelectric control can take over.  DATA PROCESSING UNIT (COMPUTER) - The computer records the tunneling current and controls the voltage to the piezoelectric tubes to produce a 3 - dimensional map of the sample surface.
  4. 4.  PIEZOELECTRIC SCANNER - Piezoelectric materials are ceramics that change dimensions in response to an applied voltage and conversely, they develop an electrical potential in response to mechanical pressure.  Piezoelectric scanners can be designed to move in x, y, and z by expanding in some directions and contracting in others. Usually fabricated from lead zirconium titanate, (PZT) by pressing together a powder, then sintering the material. They are doped to create specific materials properties.  They are polycrystalline solids. Each of the crystals in a piezoelectric material has its own electric dipole moment. These dipole moments are the basis of the scanner's ability to move in response to an applied voltage.  After sintering, the dipole moments within the scanner are randomly aligned. If the dipole moments are not aligned, the scanner has almost no ability to move. A process called poling is used to align the dipole moments.  During poling the scanners are heated to about 200°C to free the dipoles, and a DC voltage is applied to the scanner. Within hours most of the dipoles become aligned. At that point, the scanner is cooled to freeze the dipoles into their aligned state.
  5. 5.  VIBRATION ISOLATION SYSTEM - STM deals with extremely fine position measurements so the isolation of any vibrations is very important.  The tip and surface distance must be maintained by A⁰ (0.1 nm) to get desired atomic resolution.  Due to extremely high sensitivity of tunneling current between tip and the sample surface height, it is absolutely necessary to reduce inner vibrations and to isolate the system from external vibration.  Damping can be achieved by ; - Pneumatic systems - Spring system - Eddy current system
  6. 6.  The STM is based on several principles. One is the quantum mechanical effect of tunneling. It is this effect that allows us to “see” the surface.  Another principle is the piezoelectric effect. It is this effect that allows us to precisely scan the tip with angstrom-level control.  Lastly, a feedback loop is required, which monitors the tunneling current and coordinates the current and the positioning of the tip.  This is shown schematically below where the tunneling is from tip to surface with the tip rastering with piezoelectric positioning, with the feedback loop maintaining a current setpoint to generate a 3D image of the electronic topography:
  7. 7.  Tunneling is a quantum mechanical effect. A tunneling current occurs when electrons move through a barrier that they classically shouldn’t be able to move through. In classical terms, if you don’t have enough energy to move “over” a barrier, you won’t.  However, in the quantum mechanical world, electrons have wavelike properties. These waves don’t end abruptly at a wall or barrier, but taper off quickly. If the barrier is thin enough, the probability function may extend into the next region, through the barrier.  Because of the small probability of an electron being on the other side of the barrier, given enough electrons, some will indeed move through and appear on the other side. When an electron moves through the barrier in this fashion, it is called tunneling.  Quantum mechanics tells us that electrons have both wave and particle-like properties. tunneling is an effect of the wavelike nature.
  8. 8.  The top image shows us that when an electron (the wave) hits a barrier, the wave doesn’t abruptly end, but tapers off very quickly - exponentially. For a thick barrier, the wave doesn’t get past.  The bottom image shows the scenario if the barrier is quite thin (about a nanometer). Part of the wave does get through and therefore some electrons may appear on the other side of the barrier.  Because of the sharp decay of the probability function through the barrier, the number of electrons that will actually tunnel is very dependent upon the thickness of the barrier. The current through the barrier drops off exponentially with the barrier thickness. Schematic of electron wavefunction
  9. 9. 11  The piezoelectric effect was discovered by Pierre Curie in 1880. The effect is created by squeezing the sides of certain crystals, such as quartz or barium titanate.  The result is the creation of opposite charges on the sides. The effect can be reversed as well; by applying a voltage across a piezoelectric crystal, it will elongate or compress.  These materials are used to scan the tip in an scanning tunneling microscopy (STM) and most other scanning probe techniques. A typical piezoelectric material used in scanning probe microscopy is PZT (lead zirconium titanate).
  10. 10. • Electronics are needed to measure the current, scan the tip, and translate this information into a form that we can use for STM imaging. A feedback loop constantly monitors the tunneling current and makes adjustments to the tip to maintain a constant tunneling current. • These adjustments are recorded by the computer and presented as an image in the STM software. Such a setup is called a constant current image. • In addition, for very flat surfaces, the feedback loop can be turned off and only the current is displayed. This is a constant height image. Feedback loop & electron tunneling for STM
  11. 11. • A voltage bias is applied and the tip is brought close to the sample by coarse sample - tip control, which is turned off when the tip and the sample are sufficiently close. At close range, fine control of the tip in all 3 dimensions near the sample is typically piezoelectric, maintaining tip - sample separation W typically in the 4-7 A⁰ (0.4 - 0.7 nm) range. • The voltage bias will cause electrons to tunnel between the tip and sample, creating a current that can be measured. Once tunnelling is established, tip’s bias and position with respect to the sample can be varied and data are obtained from the resulting changes in the current. • If the tip is moved across the sample in the x-y plane, the changes in surface height and density of states cause changes in current. These changes are mapped in images. This change in current with respect to position can be measured itself, or the height, z of the tip corresponding to a constant current can be measured.
  12. 12. There are two main kinds of operation modes of the STM, I) constant current mode, II) constant height mode. CONSTANT CURRENT MODE - In this mode, feedback loop system forces the tip (using the z-driver) to stay at a distance from the surface that would keep a constant current flowing between the tip and the sample surface.  By recording the voltage, which has to be applied to the z-driver in order to maintain the current constant while scanning, a topographical image of the surface is produced.  Mode can be applied to surfaces that are not necessarily flat on the atomic scale i.e. stepped surfaces. The main disadvantage of this mode is the finite time of the feedback loop, which result in slowing down the scanning process.
  13. 13. CONSTANT HEIGHT MODE - In this mood, the tip is rapidly scanned over the surface at a constant height.  By recording the change in the value of the tunneling current as a function of position, a topographical image of the surface is produced.  This mode has the advantage of being faster than the constant current mode. On the other hand, there are disadvantages to this mode, such as, extracting the topographical information is harder and depending on the sample kind.  The other disadvantage is the tip might get damaged due to a crash with a “step” on the surface while scanning at high speeds. That is why this technique is used for flat surfaces (atomic scale).
  14. 14. 16 In recent years, the microscope has been utilized to investigate biological molecules deposited on suitable conducting surfaces, providing atomic resolution images of single molecules, with no conformational averaging as occurs for spectroscopic techniques associated with the study of bulk molecules.  These studies show that the technique is a potentially valuable biophysical tool complementary to the other well established methods that are extensively reviewed in this volume.  To date, high resolution images of biological systems, such as DNA globular macromolecules, such as vicilin phospholipid membranes have been obtained, with the body of scientific literature increasing rapidly with time. STM images are not direct surface images of the sample as in the case of optical microscopy rather it is measure of the local density of states of a material at its surface as a function of lateral position on the sample surface & energy.
  15. 15. STMs are helpful because they can give researchers a three dimensional profile of a surface, which allows researchers to examine a multitude of characteristics, including roughness, surface defects and determining things about the molecules such as size and conformation Other advantages of the scanning tunneling microscope include:  Capable of capturing much more detail than lesser microscopes. This helps researchers better understand the subject of their research on a molecular level.  STMs are also versatile. They can be used in ultra high vacuum, air, water and other liquids and gasses.  They will operate in temperatures as low as zero Kelvin up to a few hundred degrees Celsius.
  16. 16. There are very few disadvantages to using a scanning tunneling microscope. The two major downsides to using STMs are:  STMs can be difficult to use effectively. There is a very specific technique that requires a lot of skill and precision. STMs require very stable and clean surfaces, excellent vibration control and sharp tips.  STMs use highly specialized equipment that is fragile and expensive.  https://www.researchgate.net/publication/325334823_Scanning_Tunneling_Microscopy_ The_new_eyes_and_hands_of_the_scientists  https://my.eng.utah.edu/~lzang/images/Lecture_6_STM.pdf

×