DESIGN GUIDE
www.megadome.bworxx.com | m...
CHOOSING THE RIGHT MEGADOME
megadome.bworxx.com 2
B
2’
4’
A D
LP
HD 50 60 70 80
A (2’) 4’6” 4’6” 4’6” 4’6”
B (4’) 7’1” 7’1...
3604.794.3628 888.500.1155
LD & HD 50 60 70 80
A (2’) 7’2” 7’2” 7’2” 7’2”
B (4’) 9’10” 9’10” 9’10” 9’10”
C 20’9” 22’4” 24’...
megadome.bworxx.com 4
CBA D
LD & HD 33 40 50 60 70 80
A (2’) 13’11 13’11 12’7” 12’7” 12’7” 12’7”
B (4’) 16’4” 16’4” 15’3” ...
5604.794.3628 888.500.1155
HP
LockBlock Precast
Concrete
LP
Poured Concrete
Footing & Wall
XP
Slab on Grade with
Grade Bea...
megadome.bworxx.com 6
All MegaDomes are CAN/CSA A660 certified, in conformance to the National Building
Code of Canada (NB...
7604.794.3628 888.500.1155
MegaDomes are covered with ultra-durable POWERSHIELD® 12 oz/sq.yd woven polyethylene fabric. So...
LockBlocks
Pouredconcrete&wall
GradeBeam
WoodFoundation
ConcretePiers
HP
LP
XL
70
80
90
100
125
140
byBuildWorks
MODEL
100...
Upcoming SlideShare
Loading in …5
×

MegaDome DESIGN GUIDE 2015 V2

  • Login to see the comments

  • Be the first to like this

MegaDome DESIGN GUIDE 2015 V2

  1. 1. www.megadome.bworxx.com | megadome@bworxx.com 604.794.3628 Toll Free 888.500.1155 DESIGN GUIDE www.megadome.bworxx.com | megadome@bworxx.com 604.794.3628 Toll Free 888.500.1155 DESIGN GUIDE
  2. 2. CHOOSING THE RIGHT MEGADOME megadome.bworxx.com 2 B 2’ 4’ A D LP HD 50 60 70 80 A (2’) 4’6” 4’6” 4’6” 4’6” B (4’) 7’1” 7’1” 7’1” 7’1” C 17’7” 19’3” 20’10” 22’6” D 19’7” 21’3” 22’10” 24’6” base truss 16” 24” 16” 24” 16” 24” 16” 24” LOW PROFILESLP C LD - 2 3/4 x 1 5/8 14 ga HD - 3 9/16 x 2 14 ga HHD - 4 5/16 x 2 3/4 100 - 5 5/16 x 3 8 ga* 16” 24” 30” 33” TRUSS DIMENSIONS TRUSSCHORDS TRUSSDEPTH14 ga 11 ga* * Denotes hot-dip galvanized • Select building Width— 30, 33, 35, 40, 50, 60, 70, 80, 90, 100, 125, or 140'. • Select building Profile— LP (Low), HP (High), XP (Extra High), or XXP (Exxtra High). • EZ-Domes are single-tube arch frames available for 30, 35 and 40’ widths. • The 100+ Series—available in 100’, 125’ and 140’ widths— are only available with heavy-duty 8 ga. large section tubular framing. • Model XP100 (with nominal 100’ width) is actually 30 metres (98’-5”) wide. • Most models are available with optional Hot-Dip or Hot-Dip+ finishes for extra protection. Ask for details. • Truss spacing, truss depths and tube sections (LD, HD, HHD) are primarily a function of engineering design based on the applicable climatic data and other imposed loads.
  3. 3. 3604.794.3628 888.500.1155 LD & HD 50 60 70 80 A (2’) 7’2” 7’2” 7’2” 7’2” B (4’) 9’10” 9’10” 9’10” 9’10” C 20’9” 22’4” 24’0” 25’7” D 22’9” 24’4” 26’0” 27’7” base truss 13” 24” 13” 24” 13” 24” 13” 24” C 2’ 4’ BA D CB DA HP HIGH PROFILES XXP EXTRA HIGH PROFILES HHD 60 70 80 90 A (2’) 6’1” 6’1” 6’1” 6’1” B (4’) 9’3” 9’3” 9’3” 9’3” C 21’9” 23’5” 25’ 26’8” D 24’3” 25’11” 27’6” 29’2” base truss 13” 30” 13” 30” 13” 30” 13” 30” HHD 60 70 80 90 A (2’) 17’1” 17’1” 17’1” 17’1” B (4’) 20’3” 20’3” 20’3” 20’3” C 32’9” 34’5” 36’0” 37’8” D 35’3” 36’11” 38’6” 40’2” base truss 13” 30” 13” 30” 13” 30” 13” 30” 3 604.794.3628888.500.1155 LD&HD50607080 A(2’)7’2”7’2”7’2”7’2” B(4’)9’10”9’10”9’10”9’10” C20’9”22’4”24’0”25’7” D22’9”24’4”26’0”27’7” basetruss13”24”13”24”13”24”13”24” C 2’ 4’ B AD C BD A HPHIGHPROFILES XXPEXTRAHIGHPROFILES HHD60708090 A(2’)6’1”6’1”6’1”6’1” B(4’)9’3”9’3”9’3”9’3” C21’9”23’5”25’26’8” D24’3”25’11”27’6”29’2” basetruss13”30”13”30”13”30”13”30” HHD60708090 A(2’)17’1”17’1”17’1”17’1” B(4’)20’3”20’3”20’3”20’3” C32’9”34’5”36’0”37’8” D35’3”36’11”38’6”40’2” basetruss13”30”13”30”13”30”13”30”
  4. 4. megadome.bworxx.com 4 CBA D LD & HD 33 40 50 60 70 80 A (2’) 13’11 13’11 12’7” 12’7” 12’7” 12’7” B (4’) 16’4” 16’4” 15’3” 15’3” 15’3” 15’3” C 21’9” 22’9” 25’9” 27’5” 29’0” 30’8” D 23’1” 24’1” 27’9” 29’5” 31’0” 32’8” base truss 16” 16” 16” 16” 16” 24” 16” 24” 16” 24” 16” 24” HHD 60 70 80 90 100(30m) A (2’) 11’9” 11’9” 11’9” 11’9” 11’8” B (4’) 14’8” 14’8” 14’8” 14’8” 14’7” C 26’9” 28’5” 30’0” 31’8” 36’0” D 29’3” 30’11” 32’6” 34’2” 38’6” base truss 17” 30” 17” 30” 17” 30” 17” 30” 17” 30” 100 + 100 125 140 A B C 100 125 140 A (4’) 17’6” 17’6” 17’6” B 46’11” 50’0” 51’8” C 50’6” 54’7” 56’2” base truss 7” 33” 7” 33” 7” 33” XP HIGH PROFILES SERIES 4’ 100 (30m)
  5. 5. 5604.794.3628 888.500.1155 HP LockBlock Precast Concrete LP Poured Concrete Footing & Wall XP Slab on Grade with Grade Beam Note: All walls will be designed/engineered to suit building use, soil bearing capacity and MegaDome dead & live weights. FOUNDATIONS Concrete Piers XP Wood Foundation LP EZ-DOMES EZ-Domes are a range of single-tube arch frame structures for 30, 35 and 40’ widths. They are manufactured with heavy duty 4 5/16” HDD galvanized steel oval tubes for superior rigidity. All EZ- Domes are supplied with the same fabric cover options, and warranties, as the standard MegaDome arch-truss buildings. 30 35 40 A (4’) 10’3” 11’3” 12’2” B 14’9” 17’3” 19’8” BA 4’ XL LD 40 A (2’) 6’0” B (4’) 8’6” C 14’11” D 16’3” base truss 16” 16” A B C D EXTRA LOW PROFILES 40 LP
  6. 6. megadome.bworxx.com 6 All MegaDomes are CAN/CSA A660 certified, in conformance to the National Building Code of Canada (NBCC) requirements for all pre-engineered building—ensuring strict quality performance for engineering, manufacturing and assembly. The major Material Quality Standards, such as CSA, ASTM, ULC, AWPA, NFPA, and NBCC are adhered to. MegaDomes are Canadian Welding Bureau (CWB) certified. P. Eng. signed & sealed construction drawings are available for each project, together with Letters of Assurance of Professional Design and Commitment for Field Review (Schedules B1 & B2), if required by the Building Inspector. Designed for your project’s location. MegaDomes are designed for snow, rain, and 30/50 year wind loads for YOUR project’s specific location —in accordance with Appendix C (Climatic Design Data) of the National Building Code of Canada. ENGINEERING & CERTIFICATION MegaDome®is a registered trademark of the manufacturer, Harnois Industries Ltd. ADDITIONAL OPTIONS Side Door Your MegaDome® can be built to suit any need. Doors can be installed on gable ends and/or sides, and can be installed to swing, slide or roll-up. MegaDome® may also be fitted with lighting fixtures, fire sprinklers and different types of ventilation options. Widespan Vinyl Roll-up DoorSectional Steel Overhead Door Louvers Ventilation Mesh Doors Man Door Ventilation Ridge Vent (fixed or motorized)
  7. 7. 7604.794.3628 888.500.1155 MegaDomes are covered with ultra-durable POWERSHIELD® 12 oz/sq.yd woven polyethylene fabric. Some of the colors offered are translucent membranes – which let in natural daylight; are cooler in summer time, and which reduce energy costs. Other colors, featuring a black intermediate layer, are opaque. The interior color of all membranes are white. Membrane Options Colour Transparency Warranty WHITE translucent 2-15 SILVER s-opaque 2-15 GREEN s-opaque 2-15 SANDSTONE translucent 2-10 BLUE opaque 2-10 FIRE-RETARDANT (FR) FABRIC COVERINGS conform to CAN/ULC S-109 and NFPA 701 standards. FR-WHITE translucent 2-15 FR-GREEN opaque 2-10 FR-SANDSTONE translucent 2-10 FR-BLUE opaque 2-10 Membrane Warranty The manufacturer warranties the performance of the fabric covering as follows: 100% replacement warranty for the first 2 years; and thereafter up to 15 years in total on a pro-rated basis—refer to the table above for the specific warranty that applies to different colors and products. white silver green sandstone FR blue/blue MEMBRANE COVERS MegaDomes offer excellent resistance to corrosion. As a standard for effective general corrosion protection, low temperature silicone-bronze welding in conjunction with pre-galvanized steel is employed in the manufacturing of the MegaDomes® arch-frames. For superior protection and for corrosive environments, hot-dip galvanizing, with a 4 mil. thick zinc coating, applied after fabrication and welding is available. This provides a life expectancy of 50 years, in general use; and 25 years in industrial use. CORROSION PROTECTION Pre-galvanized steel with silicon-bronze welding. Hot-dip galvanized steel.Note: In an effort of continual improvement all information contained herein is subject to correction or change, at any time, without notice. All representations, warranties, and scope of products and services, made herein shall be confirmed by the customer and BuildWorks at the time of purchase. ©2014. Buildworks Construction Inc. V 2014.3
  8. 8. LockBlocks Pouredconcrete&wall GradeBeam WoodFoundation ConcretePiers HP LP XL 70 80 90 100 125 140 byBuildWorks MODEL 100+ XXP XP WIDTH 30 33 35 40 50 60 LENGTH: 604.794.3628 megadome@bworxx.com megadome.bworxx.com PROJECT: TITLE: DATE: NO: FreePlainGraphPaperfromhttp://incompetech.com/graphpaper/plain/ NOTTO SCALE BY: NOTES FOUNDATIONS ft

×