Welcome


                                       Ted Smudde
                                       Managing Director
     ...
Alameter
developed by Dr. Frush 1960

• For determining the correct width of the six anterior arch segment
• Selection of ...
Alameter
developed by Dr. Frush 1960

• For determining the correct width of the six anterior arch segment
• Selection of ...
Caliper
• For determining the correct width of the six anterior arch segment
• Selection of anterior teeth
Papillameter
   developed by Dr. Frush 1960


   • For determining the length of the upper lip and the anterior teeth




...
Rim Former

   Device for parallel forming/melting of bite rims to hamular notch

   Product benefits
   • Ensures paralle...
(ECB) Esthetic Control Base
Rim Former

   Product benefits
   • Ensures parallelism between upper and lower rims
   • Functional design
   • Simple h...
Use an extra hard sheet
wax, soften over a flame
and mold onto model
While wax is still soft
bend around aveolar
ridge region
Reference Papillameter measurement from operative appointment
Carve divot in base of   place calipers in divot,
model                    and open to papillameter
                      ...
Transfer Papillameter measurement to ECB
Rimformer- an integral tool for creating the ECB


                                        Wax reservoir
 Hamular notch ri...
Melt wax keeping
Rimformer securely in
hamular notch
Melt to Papillameter mark
Mark midline
Use Alameter measurement to establish buccal corridor
Create bucccal corridor using the Rimformer


                             Hold the Rimformer
                            ...
Alameter, Papillameter, and Rim Former


 ECB (esthetic control base)

• Papillameter measurements for
  Proper length of ...
Vertical and Centric
VCR Kit – Vertical and Centric Recorder Kit

Product
• This Intra Oral balancer can be used for all dental restoration whe...
Vertical and Centric Recorder

                                Includes:
                                2 Striking plates...
While pressing the
striking plate down, align
to the alatragus plane of
the model
Level with the hamular notches
Place bar in center of mark
Top of the bar is to the
                           middle of the retromolar
                           pad




Place bar ...
VCR Kit – Vertical and Centric Recorder Kit


• Vertical - Physiologic rest
• Centric –Unguided Left to right and
protrusi...
Over opened
Over closed
Correct vertical - lips should be touching
Step 2:
Establishing Centric
Ink striking plate
Mandible in rear most position
Mandible in forward most position
Slide lower jaw forward and back
      Do this several
      times, moving the
      jaw forward and
      back
Slide lower jaw forward and back
pushing the condyles back as far as possible
With mandible in REAR most position
slide mandible right then left
Do this several
times, moving the
jaw to the left and
the right
In rear most position
  slide left and right
An arrow is created
The tip of the arrow being the central bearing area




                                              ...
Tip of arrow is the central bear area




Repeat if necessary
steps
Place centric stop on tip of arrow
Lute centric stop to
the striking plate,
with hole of stop
over the tip of the
arrow
Patient will position pin
in hole of centric stop
verify the pin has
dropped into the
hole of the centric
stop
Mix a quick setting plaster
The thickness of the
mix should be like
thick sour cream
Load the plaster mix into a large barrel
syringe, like the one you would get in
the Accu-dent impression system kit.
Patient must keep mouth securely closed,
with pin in centric stop.
Inject plaster starting in the back over the retromolar pad, and move forward to the
tuberasity area
Solid bite block for mounting on an articulator
With proper vertical and centric
to create balanced occlusion
Thank you for your attention.




800 436.3827 . 323.254.1430 . www.candulor.us
Candulor  ECB & VCR
Upcoming SlideShare
Loading in …5
×

Candulor ECB & VCR

2,097 views

Published on

How to create an Esthetic Control Base and Gothic Arch Tracing

0 Comments
1 Like
Statistics
Notes
  • Be the first to comment

No Downloads
Views
Total views
2,097
On SlideShare
0
From Embeds
0
Number of Embeds
3
Actions
Shares
0
Downloads
28
Comments
0
Likes
1
Embeds 0
No embeds

No notes for slide

Candulor ECB & VCR

  1. 1. Welcome Ted Smudde Managing Director Candulor USA 800 436.3827 . 323.254.1430 . www.candulor.us
  2. 2. Alameter developed by Dr. Frush 1960 • For determining the correct width of the six anterior arch segment • Selection of anterior teeth
  3. 3. Alameter developed by Dr. Frush 1960 • For determining the correct width of the six anterior arch segment • Selection of anterior teeth
  4. 4. Caliper • For determining the correct width of the six anterior arch segment • Selection of anterior teeth
  5. 5. Papillameter developed by Dr. Frush 1960 • For determining the length of the upper lip and the anterior teeth 14 mm incisal papilla rest R. Horn, J. Stuck
  6. 6. Rim Former Device for parallel forming/melting of bite rims to hamular notch Product benefits • Ensures parallelism between upper and lower rims • Functional design • Simple handling R. Horn, J. Stuck
  7. 7. (ECB) Esthetic Control Base
  8. 8. Rim Former Product benefits • Ensures parallelism between upper and lower rims • Functional design • Simple handling R. Horn, J. Stuck
  9. 9. Use an extra hard sheet wax, soften over a flame and mold onto model
  10. 10. While wax is still soft bend around aveolar ridge region
  11. 11. Reference Papillameter measurement from operative appointment
  12. 12. Carve divot in base of place calipers in divot, model and open to papillameter measurement
  13. 13. Transfer Papillameter measurement to ECB
  14. 14. Rimformer- an integral tool for creating the ECB Wax reservoir Hamular notch rim channel
  15. 15. Melt wax keeping Rimformer securely in hamular notch
  16. 16. Melt to Papillameter mark
  17. 17. Mark midline
  18. 18. Use Alameter measurement to establish buccal corridor
  19. 19. Create bucccal corridor using the Rimformer Hold the Rimformer tilted to the lingual Start to melt from the tuburasity area, and melt forward to the distal point of the canine
  20. 20. Alameter, Papillameter, and Rim Former ECB (esthetic control base) • Papillameter measurements for Proper length of centrals • Alameter measurements for Proper width of six anterior arch segment • Mid-line • High lip line
  21. 21. Vertical and Centric
  22. 22. VCR Kit – Vertical and Centric Recorder Kit Product • This Intra Oral balancer can be used for all dental restoration when vertical and centric relation needs to be established. Product benefits • Improves function of the dentures • Proper centric relation • Physiologic vertical dimension • Allows free movement of the condyles
  23. 23. Vertical and Centric Recorder Includes: 2 Striking plates 2 Long bars 1 Short Bar 3 Long screws 1 Short screw 3 Threaded sleeves 3 Nuts 5 Plastic stops 1 Screw driver 1 Inking pen 1 Wrench
  24. 24. While pressing the striking plate down, align to the alatragus plane of the model
  25. 25. Level with the hamular notches
  26. 26. Place bar in center of mark
  27. 27. Top of the bar is to the middle of the retromolar pad Place bar from anterior to posterior, parallel to the angle of the alatragus plane
  28. 28. VCR Kit – Vertical and Centric Recorder Kit • Vertical - Physiologic rest • Centric –Unguided Left to right and protrusive and retrusive mandibular movement produces gothic arch tracing
  29. 29. Over opened
  30. 30. Over closed
  31. 31. Correct vertical - lips should be touching
  32. 32. Step 2: Establishing Centric
  33. 33. Ink striking plate
  34. 34. Mandible in rear most position
  35. 35. Mandible in forward most position
  36. 36. Slide lower jaw forward and back Do this several times, moving the jaw forward and back
  37. 37. Slide lower jaw forward and back pushing the condyles back as far as possible
  38. 38. With mandible in REAR most position slide mandible right then left
  39. 39. Do this several times, moving the jaw to the left and the right
  40. 40. In rear most position slide left and right
  41. 41. An arrow is created The tip of the arrow being the central bearing area Balanced pressure Balanced pressure
  42. 42. Tip of arrow is the central bear area Repeat if necessary steps
  43. 43. Place centric stop on tip of arrow
  44. 44. Lute centric stop to the striking plate, with hole of stop over the tip of the arrow
  45. 45. Patient will position pin in hole of centric stop
  46. 46. verify the pin has dropped into the hole of the centric stop
  47. 47. Mix a quick setting plaster
  48. 48. The thickness of the mix should be like thick sour cream
  49. 49. Load the plaster mix into a large barrel syringe, like the one you would get in the Accu-dent impression system kit.
  50. 50. Patient must keep mouth securely closed, with pin in centric stop.
  51. 51. Inject plaster starting in the back over the retromolar pad, and move forward to the tuberasity area
  52. 52. Solid bite block for mounting on an articulator
  53. 53. With proper vertical and centric to create balanced occlusion
  54. 54. Thank you for your attention. 800 436.3827 . 323.254.1430 . www.candulor.us

×