Successfully reported this slideshow.
We use your LinkedIn profile and activity data to personalize ads and to show you more relevant ads. You can change your ad preferences anytime.
Drywell Applications
Commercial Drainage
Free Design Assistance
Residential Drainage Internal Manifold
Variety of Sizes
Si...
The CULTEC Contactor®
and Recharger®
chambers provide cost-effective underground
stormwater retention and detention soluti...
Contactor
Field Drain
C-4
Contactor
EZ-24
Contactor
100
Contactor
100HD
Recharger
150XLHD
Recharger
280HD
Recharger
330XLH...
Contactor®
& Recharger®
Plastic Chambers for Stormwater ManagementPlastic Chambers for Stormwater Management Since 1986Sin...
Upcoming SlideShare
Loading in …5
×

CULTEC We Have Solutions stormwater product specification brochure (CULG087 04-15)

251 views

Published on

CULTEC Contactor & Recharger plastic chambers for stormwater management specification and cross section detail brochure. CULTEC chambers may be used for Commercial / Residential drainage. Version 04-15

Published in: Engineering
  • Be the first to comment

  • Be the first to like this

CULTEC We Have Solutions stormwater product specification brochure (CULG087 04-15)

  1. 1. Drywell Applications Commercial Drainage Free Design Assistance Residential Drainage Internal Manifold Variety of Sizes Since 1986Since 1986 WE HAVE SOLUTIONS The Founder of Plastic Chamber Technology Contactor® & Recharger® Plastic ChambersPlastic Chambers for Stormwaterfor Stormwater ManagementManagement
  2. 2. The CULTEC Contactor® and Recharger® chambers provide cost-effective underground stormwater retention and detention solutions while minimizing area, labor, materials and associated costs. CULTEC’s Recharger® series are higher profile, larger capacity chambers for maximizing storage in a condensed footprint. CULTEC’s low profile Contactor® series can accommodate systems with high water tables or other depth restraints. The lower profile units may also be used when a larger infiltrative surface area is required by design. Recharger® & Contactor® Stormwater Chambers • Chamber Sizes from 8.5” - 48” High • Internal Manifold for Efficiency and Cost-Effectiveness • Earn Up to 22 LEED Credits • Maximized Storage Capability in Minimized Area • Quick and Easy Overlapping Rib-Lock Connection • Corrugated Arch Design for Structural Integrity • Requires Less Heavy Equipment and Labor • Light Weight Allows for Less Downtime During Handling and Placement • Minimized Shipping Costs and Stockpile Area Requirements • Approved for Use in Traffic Applications • Included in Popular Hydrology Modeling Software Programs • Free HydroCAD® CULTEC Edition Available • Complimentary Project-Specific Calculations and Drawings Contactor® & Recharger® Plastic Chambers for Stormwater ManagementPlastic Chambers for Stormwater Management Since 1986Since 1986 The Founder of Plastic Chamber Technology CULG087 04-15
  3. 3. Contactor Field Drain C-4 Contactor EZ-24 Contactor 100 Contactor 100HD Recharger 150XLHD Recharger 280HD Recharger 330XLHD Recharger V8HD Recharger 902HD Length 8.5 2.59 8.5 2.59 8 2.44 8 2.44 11 3.35 8 2.44 8.5 2.59 8 2.44 4.10 1.25 Installed Length 8 2.44 8 2.44 7.4 2.26 7.5 2.29 10.25 3.12 7 2.13 7 2.13 7.5 2.29 3.67 1.12 Length Adjustment 0.50 0.15 0.50 0.15 0.60 0.18 0.50 0.15 0.75 0.23 1.00 0.30 1.50 0.46 -5.83 -1.78 0.44 0.13 Width 48 1219 16 406 36 914 36 914 33 838 47 1194 52 1321 60 1524 78 1981 Height 8.5 216 12 305 12.5 318 12.5 318 18.5 470 26.5 673 30.5 775 32 813 48 1219 Bare Chamber Storage 1.692 12.66 0.16 157.18 0.819 6.13 0.08 76.08 1.961 14.67 0.18 182.17 1.866 13.96 0.17 173.35 2.65 19.82 0.25 246.18 6.079 45.48 0.56 564.73 7.459 55.80 0.69 692.93 8.679 64.93 0.81 806.27 17.660 132.11 1.64 1640.59 Bare Chamber Storage per Unit for Intermediate Unit 13.54 101 0.38 383.28 6.55 49 0.19 185.52 14.51 109 0.41 410.90 14.00 105 0.40 396.28 27.16 203 0.77 769.12 42.55 318 1.21 1204.91 52.21 391 1.48 1478.44 65.09 487 1.84 1843.13 64.75 484 1.83 1833.53 Bare Chamber Storage per Unit for Stand Alone Unit 14.38 108 0.41 407.23 6.96 52 0.20 197.12 15.69 117 0.44 444.21 14.93 112 0.42 422.70 29.15 218 0.83 825.40 48.63 364 1.38 1377.04 63.40 474 1.80 1795.25 44.12 330 1.25 1249.23 70.27 526 1.99 1989.77 Min. Installed Storage per Unit for Intermediate Unit 29.99 224 0.85 849.14 14.06 105 0.40 398.25 28.85 216 0.82 816.94 28.81 216 0.82 815.88 50.17 375 1.42 1420.46 64.46 482 1.83 1825.21 79.26 593 2.24 2244.25 99.56 745 2.82 2818.97 99.99 748 2.83 2831.38 Min. Installed Storage per Unit for Stand Alone Unit 31.86 238 0.90 902.21 14.94 112 0.42 423.14 31.19 233 0.88 883.18 30.73 230 0.87 870.27 53.84 403 1.52 1524.39 73.67 551 2.09 2085.96 96.24 720 2.73 2725.16 67.48 505 1.91 1910.64 120.54 902 3.41 3413.03 Price per Unit Date of Quote:________________ Prices are good for ________ days Contactor® & Recharger® Plastic Chambers for Stormwater ManagementPlastic Chambers for Stormwater Management Since 1986Since 1986 The Founder of Plastic Chamber Technology Information for the Recharger V8HD is based on the V8IHD Intermediate section except where specifically noted. See www.cultec.com for information on Starter and End Sections. The Recharger 902HD only comes in only one model type and requires a separate end plate. The Intermediate model for the Recharger 902HD in this case means a model which has an installed length of 3.67’ (1.12 m) located in the middle of a row. A stand alone model for the Recharger 902HD is a single chamber with two end plates. All other models as stand alone units shall be called Model R. We carry the largest variety of sizes in the industry. inches mm feet meters feet meters ft3 /ft gal/ft m3 /m l/m feet meters ft3 gallons m3 liters ft3 gallons m3 liters inches mm ft3 gallons m3 liters ft3 gallons m3 liters CULG087 04-15
  4. 4. Contactor® & Recharger® Plastic Chambers for Stormwater ManagementPlastic Chambers for Stormwater Management Since 1986Since 1986 CULG087 04-15 Recharger V8HD information is based on V8IHD Intermediate unit. See www.cultec.com for information on Recharger V8HD Starter / End. Other models available. Contact CULTEC for more information. Calculations are based on installed chamber length. Most calculations assume a 6” (152 mm) stone base, 6” (152 mm) stone above and typical center-to-center spacing. Recharger 902HD assumes 9” (229 mm) stone base, 12” (305 mm) stone above and typical center-to-center spacing. SMALL RIB LARGE RIB G TRIM SIDE PORTAL AND INSERT HVLV FEED CONNECTOR TO CREATE INTERNAL MANIFOLD F CULTEC, Inc. 878 Federal Road • P.O. Box 280 • Brookfield, CT 06804 USA P: 203-775-4416 • Toll Free: 1(800)4-CULTEC • F: 203-775-1462 • www.cultec.com • A C B D CULTEC HEAVY DUTY CHAMBER CULTEC HVLV FEED CONNECTOR (WHERE APPLICABLE) 95% COMPACTED FILL NON-WOVEN FILTER FABRIC AROUND STONE E PAVEMENT 6” (152 mm) MIN. TYP. [9” (229 mm) MIN. FOR 902HD] 6” (152 mm) MIN. TYP. [12” (305 mm) MIN. FOR 902HD] 12” (304 mm) TYP. A B C D E F G Model Chamber Width Typical Center- to-Center Spacing Chamber Height Min. Depth (Paved) Max.Depth Min. Depth (Paved) Installed Chamber Length Overall Chamber Length Bare Chamber Volume Min. Installed Storage Min. Stone Required per Chamber CULTEC Contactor 100HD 36” 40” 12.5” 14” 12’ 8” 7.5’ 8’ 1.87 ft3 /ft 3.84 ft3 /ft 28.81 ft3 /unit 1.37 yd3 914 mm 1016 mm 318 mm 356 mm 3.66 m 203 mm 2.29 m 2.44 m 0.17 m3 /m 0.36 m3 /m 0.82 m3 /unit 1.05 m3 CULTEC Recharger 150XLHD 33” 39” 18.5” 14” 12’ 8” 10.25’ 11’ 2.65 ft3 /ft 4.89 ft3 /ft 50.17 ft3 /unit 2.13 yd3 838 mm 991 mm 470 mm 356 mm 3.66 m 203 mm 3.12 m 3.35 m 0.25 m3 /m 0.45 m3 /m 1.42 m3 /unit 1.63 m3 CULTEC Recharger 280HD 47” 52” 26.5” 14” 12’ 8” 7’ 8’ 6.08 ft3 /ft 9.21 ft3 /ft 64.46 ft3 /unit 2.03 yd3 1194 mm 1321 mm 673 mm 356 mm 3.66 m 203 mm 2.13 m 2.44 m 0.56 m3 /m 0.86 m3 /m 1.83 m3 /unit 1.55 m3 CULTEC Recharger 330XLHD 52” 58” 30.5” 16” 12’ 10” 7’ 8.5’ 7.46 ft3 /ft 11.32 ft3 /ft 79.26 ft3 /unit 2.50 yd3 1321 mm 1473 mm 775 mm 406 mm 3.66 m 254 mm 2.13 m 2.59 m 0.69 m3 /m 1.05 m3 /m 2.24 m3 /unit 1.91 m3 CULTEC Recharger V8HD 60” 66” 32” 18” 8’ 12” 7.5’ 8’ 8.68 ft3 /ft 13.27 ft3 /ft 99.56 ft3 /unit 3.19 yd3 1524 mm 1676 mm 813 mm 457 mm 2.44 m 305 mm 2.29 m 2.44 m 0.81 m3 /m 1.23 m3 /m 2.82 m3 /unit 2.44 m3 CULTEC Recharger 902HD 78” 87” 48” 24” 8.3’ 12” 3.67’ 4.10’ 17.66 ft3 /ft 27.27 ft3 /ft 100 ft3 /unit 3.26 yd3 1981 mm 2210 mm 1219 mm 610 mm 2.53 m 305 mm 1.12 m 1.25 m 1.64 m3 /m 2.53 m3 /m 2.83 m3 /unit 2.49 m3

×