  1. 1. Brown Brothers Milawa Winery CO2 Heat Pump Case Study Automatic Heating Global Pty Ltd 208-09/05/2019 – Melbourne, Australia #GoNatRefs
  2. 2. AHG Intro • In Heating and Hot Water since 1926! • Commercial and Industrial • Focus on Performance, Sustainability and Affordability 308-09/05/2019 – Melbourne, Australia #GoNatRefs Brown Brothers Milawa Winery
 CO2 Heat Pump Case Study

  3. 3. Brown Brothers Milawa Winery
 CO2 Heat Pump Case Study
 Eco-Cute CO2 Heat Pump Intro • Unique Heat Pump technology – CO2 Nat Ref producing 90°C Hot Water • Ozone depletion potential (ODP) 
 of zero • Global warming potential (GWP) 
 of 1 • Increasing demand from users in Government, Commercial and Industrial sectors 408-09/05/2019 – Melbourne, Australia #GoNatRefs
  4. 4. Project Challenges: • Hot water required for rinsing filtration equipment 500-750 L/hr • Selectable temperature 55-85°C • Existing boilers fired by LPG - expensive to run and fossil fuel dependant • Additional pipework needed for LPG in new location • Minimum ambient temp -5°C • Quick install time needed 508-09/05/2019 – Melbourne, Australia #GoNatRefs Brown Brothers Milawa Winery
 CO2 Heat Pump Case Study

  5. 5. Project Solution: • Eco-Cute CO2 Heat Pump • 1500L stainless steel twin coil WaterMark approved tank • Compact pre-fab skid Frame for ease of transportation 608-09/05/2019 – Melbourne, Australia #GoNatRefs Brown Brothers Milawa Winery
 CO2 Heat Pump Case Study

  6. 6. Project Outcomes: • New installation at Brown Brothers has been calculated to save 75% of energy costs • Environmentally friendly – CO2 refrigerant • 4 Hour Install Time • Produces 65-90°C hot water • No new gas pipework required 708-09/05/2019 – Melbourne, Australia #GoNatRefs Brown Brothers Milawa Winery
 CO2 Heat Pump Case Study

  7. 7. 808-09/05/2019 – Melbourne, Australia #GoNatRefs Other CO2 Heat Pump Projects
 Yarra’s Edge Tower 1
  8. 8. 908-09/05/2019 – Melbourne, Australia #GoNatRefs Other CO2 Heat Pump Projects
 Nightingale 2
  9. 9. Thank You! CO2 Heat Pump Summary: • Affordable system for Heating and Domestic Hot Water (DHW) • Works all seasons -10°C to 40°C • COP of 3.5-4.0 (Highly Efficient) • Reduce dependence on Fossil Fuels • Utilises electricity generated from PV, Wind and other clean energy sources What we offer: • Free site assessments • In-house Engineering System Analysis and Design • Ongoing Technical Support and After Sales Service • World-class product range including Heat Pumps and Condensing Boilers • Focus on Efficiency and Performance 1008-09/05/2019 – Melbourne, Australia #GoNatRefs

×