SAFETY AND MAINTENANCE SOLUTIONS FOR NETWORK ELECTRICIANS
 GENERAL PRESENTATION
■ THE NOVARC GROUP – ESP DIVISION
1/ To protect operators against electrical risks to work in total...
 GENERAL PRESENTATION
■ THE NOVARC GROUP - ESP DIVISION
 PRODUCTION
 COMMERCIALISATION
 GENERAL PRESENTATION
■ THE NOVARC GROUP - ESP DIVISION
 Key figures
 GENERAL PRESENTATION
■ THE NOVARC GROUP - ESP DIVISION
Our know how
100% Products design and made in France
Compliance ...
 MAINTENANCE AND OPERATION ON THE LOW VOLTAGE NETWORK
UNDERGROUND OPERATIONS
OVERHEADLINE OPERATIONS
 RANGES OF PRODUCTS
 RANGES OF PRODUCTS
■ CLIMBING EQUIPMENTS
 RANGES OF PRODUCTS
■ ANTI-FALL PROTECTIVE EQUIPMENTS
 RANGES OF PRODUCTS
■ ARC FLASH PROTECTION
 RANGES OF PRODUCTS
■ LOW VOLTAGE DETECTOR
TAG780D
Two probes designed
for comfortable
handling with gloves
Slim
probes
Test Bouton
suitable for
electrician’s
gloves
Silicon...
■ Functions of the LV detectorFunctions of the LV detector
 Hazardous voltage light & sound
indication : above 50V AC 120...
Display
 Display accuracy: +/-2% + 1digit
 Display Resolution : 1V
 Standard : IEC 61243-3 = 2010
 Batteries 2 x 1,5V ...
■ Standard and EnvironmentStandard and Environment
 LV DETECTOR TAG 780D
Low voltage detector with digital display TAG 78...
 LV Phase rotation Indicator DR 706
 LV Phase rotation Indicator DR 706
Ergonomically shaped to
fit comfortably in the palm
Replaceable leads
with European
c...
■ Functions of the LV Phase rotation IndicatorFunctions of the LV Phase rotation Indicator
 LV Phase rotation Indicator D...
■ Specification of the Phase rotation IndicatorSpecification of the Phase rotation Indicator
 LV Phase rotation Indicator...
 LV Phase rotation Indicator DR 706
■ Standard and EnvironmentStandard and Environment
 Category of use : cat. IV (netwo...
 LV DEAD UNDERGROUND NETWORK
■ EARTHING and SHORT-CIRCUITING
 LV Live Underground Cable Identifier FC5300
 LV Live Cable Identifier FC5300
 LV Live Cable Identifier FC5300
Heavy duty sealed case Instructions always
visible to guide the
user step by step
Reliab...
 LV Live Cable Identifier FC5300
■ Functions of the LV Live Cable IdentifierFunctions of the LV Live Cable Identifier
 I...
 LV Live Cable Identifier FC5300
■ Specifications of the LV Live Cable IdentifierSpecifications of the LV Live Cable Iden...
 LV Live Cable Identifier FC5300
■ Specifications of the LV Live Cable IdentifierSpecifications of the LV Live Cable Iden...
 LV Live Cable Identifier FC5300
■ Specifications of the LV Live Cable IdentifierSpecifications of the LV Live Cable Iden...
 LV Live Cable Identifier FC5300
■ Specifications of the LV Live Cable IdentifierSpecifications of the LV Live Cable Iden...
 LV Live Cable Identifier FC5300
■ Standard and EnvironmentStandard and Environment
 Compliant and qualified to EDF-Sere...
 LV DEAD LINE NETWORK
■ EARTHING and SHORT-CIRCUITING
 LV UNDERGROUND & OVERHEADLINE NETWORK
■ DETECTION AND EARTHING
INSULATING STICKS
 LV LIVE WORKING
■ INSULATED/INSULATING TOOLS 1000 V
 RANGES OF PRODUCTS
■ CABLE PREPARATION TOOLS
 LV LIVE WORKING
■ TEMPORARY INSULATION
 RANGES OF PRODUCTS
■ SUBSTATION EQUIPEMENT/ RESCUE EQUIPMENT
 OUR CLIENTS
■ THEY ARE TRUSTING US
 END OF THE PRESENTATION
THANK YOU VERY MUCH FOR YOUR ATTENTION
WORK IN TOTAL CONFIDENCE ON YOUR POWER NETWORK
FOR UAE: s...
Upcoming SlideShare
Loading in …5
×

Electrical Safety Equipments PPE Low voltage presentation SFE in UAE

959 views

Published on

- Electrical Safety Products: industrial safety helmet for linemen, safety helmet for linemen with short visor, safety helmet with integrated face screen for electricians, Electrician face shield with headband and brow-guard, Arc-Flash protective face shield, helmet for use in the forestry industry, safety cap, glasses, headgears, safety shoes, safety boots, insulating mats, work gears, high-visibility garments, rain protection, climbing equipment, harnesses, energy absorbers, fall arresters, anchorage, connectors, lanyards, sets, rescue devices, latex gloves, composite chlorinated gloves, leather gloves, handling leather gloves, preliminary identification of cables and phases, no-voltage testing / absence of voltage testing, earthing and short-circuiting, earthing stickes, insulating tools 1000 V, cable cutters, shunt, repowering, network controlling and measuring equipment, substation equipment, (FAMECA, Sibille Safe, Jegou industries, Technowill)
- Hand Tools (short & long tapes, squares, levels & chalk lines, laser, electronic devices & torches, knives, blades, screwdrivers, saws, planes, surforms & chisels, demolition, hammers & cold chisels, clamps & pliers, mechanical tools, stapling, riveting & gluing, tool storage, decoration (Stanley)
- Power Tools: rotary drills, large drills, magnetic drills, percussion drills, compact hammers, combination hammers, small angle grinders, polisher, die grinders, chopsaw (cut-off machine), cordless light/charger, diamond drilling, miter saws, jigsaws, reciprocating saws, circular saws, plunge saw, sanders, routers, planers, screw drivers, impact wrench, lasers, thermometer, stationary machines (Dewalt)
- Air Tool Kits, Air compressors, Tool boxes, Vacuum cleaners, Tool chests (Michelin)
- Welding Tools (Blue Weld)
- Construction Steel binding machines (Gocmaksan)
- Construction Steel cutting machines (portable also) (Gocmaksan)
- Spiral Construction Steel binding machines (Gocmaksan)
- Stirr-up Construction Steel binding machines (Gocmaksan)
- Mesh Steel binding machines (Gocmaksan)
- Scaffolding and formwork accessories
- Power Generators: Open set Generators, Close set Generators, Automatic transfer switch, Light towers. (Engine Perkins)
We deliver everywhere in the UAE.
Website: www.alburaqtools.ae
Email: sales@alburaqtools.ae
T: 042292810
F: 042292811
Dubai, UAE

Published in: Business
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
959
On SlideShare
0
From Embeds
0
Number of Embeds
8
Actions
Shares
0
Downloads
47
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Electrical Safety Equipments PPE Low voltage presentation SFE in UAE

  1. 1. SAFETY AND MAINTENANCE SOLUTIONS FOR NETWORK ELECTRICIANS
  2. 2.  GENERAL PRESENTATION ■ THE NOVARC GROUP – ESP DIVISION 1/ To protect operators against electrical risks to work in total confidence on the network 2/ To provide secured, easy to use and reliable products 3/ To improve maintenance and operations on the network
  3. 3.  GENERAL PRESENTATION ■ THE NOVARC GROUP - ESP DIVISION  PRODUCTION  COMMERCIALISATION
  4. 4.  GENERAL PRESENTATION ■ THE NOVARC GROUP - ESP DIVISION  Key figures
  5. 5.  GENERAL PRESENTATION ■ THE NOVARC GROUP - ESP DIVISION Our know how 100% Products design and made in France Compliance with the EN and IEC standard More 60 years experience in electrical safety equipments
  6. 6.  MAINTENANCE AND OPERATION ON THE LOW VOLTAGE NETWORK UNDERGROUND OPERATIONS OVERHEADLINE OPERATIONS
  7. 7.  RANGES OF PRODUCTS
  8. 8.  RANGES OF PRODUCTS ■ CLIMBING EQUIPMENTS
  9. 9.  RANGES OF PRODUCTS ■ ANTI-FALL PROTECTIVE EQUIPMENTS
  10. 10.  RANGES OF PRODUCTS ■ ARC FLASH PROTECTION
  11. 11.  RANGES OF PRODUCTS ■ LOW VOLTAGE DETECTOR TAG780D
  12. 12. Two probes designed for comfortable handling with gloves Slim probes Test Bouton suitable for electrician’s gloves Silicone double insulated lead CAT IV 1000VCAT IV 1000V IP65IP65 DIGITALDIGITAL  LV Detector TAG 780D LEDs Digital display Go / No Go indication
  13. 13. ■ Functions of the LV detectorFunctions of the LV detector  Hazardous voltage light & sound indication : above 50V AC 120V DC ;  Redundant measurement batteries  Circuit w/o  Unipolar Phase indication on the 2 probes (NEUTRAL FAILURE detection)  PHASE SEQUENCE (field rotation) compatible with Gen Set  Indication of Voltage levels 120V 230V 400V 1000V  Voltage display from 5 V to 999 V (3 digits)  POLARITY indication on DC  CONTINUITY test < 100 Ω  AC or DC indication  TEST BUTTON  LV Detector TAG 780D Every function compatible with electrician gloves
  14. 14. Display  Display accuracy: +/-2% + 1digit  Display Resolution : 1V  Standard : IEC 61243-3 = 2010  Batteries 2 x 1,5V LR03 (AAA) ■ Specifications of the LV detectorSpecifications of the LV detector Field of Use  Voltage range 5V - 1000 V AC ; 5V – 1500V DC  Nominal Voltage indications : 120, 230, 400 et 1000V AC DC  Operating current < 3.5 mA  1000V cat. IV  Frequency range for AC: 15 Hz to 60 Hz  Temperature : - 15°C + 45°C  LV Detector TAG 780D
  15. 15. ■ Standard and EnvironmentStandard and Environment  LV DETECTOR TAG 780D Low voltage detector with digital display TAG 780D Two-pole Low-Voltage Detector Standard IEC 61243-3 (2009-11)  Main purpose: Proving Dead = Checking the absence of operating voltage before connecting earthing device.  Technical Specific feature : the device are equipped with a « low impedance » circuit to drain residual current and make the difference with operating voltage. (vs. Multimeters with ultra high impedance).  100% Availability to secure safety mission:  NO Fuse but reversible variable resistors  Redundant circuit for Hazardous voltage indication operating w/o battery.
  16. 16.  LV Phase rotation Indicator DR 706
  17. 17.  LV Phase rotation Indicator DR 706 Ergonomically shaped to fit comfortably in the palm Replaceable leads with European colour codes and L1/L2/L3 marking (other markings or colours to order). Probes with HPC fuses : Ø 4 mm – IP2X Heavy duty waterproof housing Can be used in all weathers Protection : IP65 housing and circuit totally sealed with compround Unique bright LED display Chasing red LEDs for the counter- clockwise rotation.
  18. 18. ■ Functions of the LV Phase rotation IndicatorFunctions of the LV Phase rotation Indicator  LV Phase rotation Indicator DR 706  PHASE ROTATION / SEQUENCE TESTER INDICATOR
  19. 19. ■ Specification of the Phase rotation IndicatorSpecification of the Phase rotation Indicator  LV Phase rotation Indicator DR 706  Voltage range : 80V to 400 V AC  AC frequency range : 50 Hz & 60 Hz  Maximum rated voltage : 440 V three phase system  Category of use : cat. IV (network)  Class : N = - 10°C to + 55°C
  20. 20.  LV Phase rotation Indicator DR 706 ■ Standard and EnvironmentStandard and Environment  Category of use : cat. IV (network)  Probes with HPC fuses : Ø 4 mm –IP2X  Protection : IP65 housing and circuit totally sealed with campound
  21. 21.  LV DEAD UNDERGROUND NETWORK ■ EARTHING and SHORT-CIRCUITING
  22. 22.  LV Live Underground Cable Identifier FC5300
  23. 23.  LV Live Cable Identifier FC5300
  24. 24.  LV Live Cable Identifier FC5300 Heavy duty sealed case Instructions always visible to guide the user step by step Reliable connectors : double-insultated, sheathed, sheathed conductors, in accordance with new standards Directional probe allows certain identification of the cable Clear Identification Connection of the most universal identification signal and phase generator (modulator) possible on the customer’s network or in a connection bos
  25. 25.  LV Live Cable Identifier FC5300 ■ Functions of the LV Live Cable IdentifierFunctions of the LV Live Cable Identifier  Identification of Low Voltage live cables : - In order to make a live connection - Prior to de-energized operation  Didactic operating mode present on the modulator  Secured identification : The device indicates that it has identified the cable through a cross checking of frequencies and signal patterns.  Signal identification is secure due to current drawing method and digital signature : no signal on the adjacent cables or on MV cables  Overhead and underground cables  “Paper-lead”, “dry”, “double steel armouring” cables.  Urban, suburban and rural areas
  26. 26.  LV Live Cable Identifier FC5300 ■ Specifications of the LV Live Cable IdentifierSpecifications of the LV Live Cable Identifier  FC5300E modulator :  Nominal voltage 220 V rms to 400 V rms three phase, bi phase or single phase  Maximum rated voltage 440 V rms between inputs  Network frequency 50 Hz or 60 Hz to be specified  Number of channels 2  Duration of tapping per channel 0.256 s (per cycle)  Pulse cycle 0.16 Hz  Rms tapping current ~4 A/channel during impulse  Peak current under 230 V or 400 V ~16 A peak
  27. 27.  LV Live Cable Identifier FC5300 ■ Specifications of the LV Live Cable IdentifierSpecifications of the LV Live Cable Identifier  Inputs protection : fast-acting HRC fuses in the housing and at the IP2X leads connecting points  Overvaltage Category : 1000 V – Cat.IV  Operating temperature - 20°C to + 40°C  Forced ventilation 2 + 2 fans  Max. temperature protection by switching off the tapping : 90°C ±3  Approximate dimensions : 470 x 360 x 190 mm  Approximate mass 9.85 kg
  28. 28.  LV Live Cable Identifier FC5300 ■ Specifications of the LV Live Cable IdentifierSpecifications of the LV Live Cable Identifier  FC5300D detector :  Power suply battery 3.7 V (Lithium-ion)  Autonomy over 1000 detections  Display screen LCD 128 x 64 backlight  Battery level check battery level indication  Choice of functions by dedicated buttons  Automatic standby and power cut-off  Menus available in 6 languages  External magnetic probe  Analyser DSP/ARM + PIC
  29. 29.  LV Live Cable Identifier FC5300 ■ Specifications of the LV Live Cable IdentifierSpecifications of the LV Live Cable Identifier  Approximate dimensions 160 x 95 x 50 mm  Approximate mass 0.35 kg (with battery)  Battery charger USB type, mains and vehicle  Protection shockproof rubber-type shell  FC5k3SD probe :  Receiving sensor magnetic, differential  3 sensitivities according to the type of cable  Protection by shockproof “rubber” positioning shoe
  30. 30.  LV Live Cable Identifier FC5300 ■ Standard and EnvironmentStandard and Environment  Compliant and qualified to EDF-Serect specification ST BT 840C (2000- 11)  CE marking  Compliant with European Directives :  Relating to electromagnetic compatibility (EMC Directive) 89/336/EEC, 92/31/EEC, 93/68/EEC et 92-587/RF, 95-283/RF standard EN 55011 edition 2009 + A1/2010  Relating to safety of low-voltage equipment (LV Directive) 73/23/EEC et 75-848/RF standards IEC/EN 61010-1 ed. 3.0 (2010-06) IEC/EN 61010-031 ed.1.1 (2008-06)
  31. 31.  LV DEAD LINE NETWORK ■ EARTHING and SHORT-CIRCUITING
  32. 32.  LV UNDERGROUND & OVERHEADLINE NETWORK ■ DETECTION AND EARTHING INSULATING STICKS
  33. 33.  LV LIVE WORKING ■ INSULATED/INSULATING TOOLS 1000 V
  34. 34.  RANGES OF PRODUCTS ■ CABLE PREPARATION TOOLS
  35. 35.  LV LIVE WORKING ■ TEMPORARY INSULATION
  36. 36.  RANGES OF PRODUCTS ■ SUBSTATION EQUIPEMENT/ RESCUE EQUIPMENT
  37. 37.  OUR CLIENTS ■ THEY ARE TRUSTING US
  38. 38.  END OF THE PRESENTATION THANK YOU VERY MUCH FOR YOUR ATTENTION WORK IN TOTAL CONFIDENCE ON YOUR POWER NETWORK FOR UAE: sales@alburaqtools.ae

×