  1. 1. XT-Series Expanding the Power of Fluorescent Flow Cytometry Shahbaz Shamshad B.S.M.T. 3rd Year S.D.L.S. L.N.H. sysmax
  2. 2. Sysmax Manufacturers <ul><li>Sysmex was the first company to use fluorescent flow cytometry and cell counting methods to reliably detect abnormal samples and reduce false positives. </li></ul><ul><li>Take advantage of our experience. </li></ul>
  3. 3. Sysmex XT-2000i <ul><li>The Sysmex XT-2000i is an automated hematology analyzer for in vitro diagnostic use. The XT-2000i can analyze and output the results of 24 parameters of a blood sample by using an optical detector block based on flow cytometry and a semiconductor laser. </li></ul>
  4. 5. Technologies <ul><li>Fluorescent Flow Cytometry method: </li></ul><ul><li>DC sheath flow method: </li></ul><ul><li>SLS method : </li></ul>
  5. 6. Parameters <ul><li>There are 24 parameters </li></ul><ul><li>WBC,RBC,HGB,HCT,MCV,MCH,MCHC,PLT </li></ul><ul><li>Neut%, Lymph%, Mono%, Eo% ,Baso% </li></ul><ul><li>Neut#, Lymph#, Mono#, Eo#, </li></ul><ul><li>Baso# </li></ul><ul><li>RDW-SD,RDW-CV,MPV,RET%,RET#,IRF </li></ul>
  6. 7. Aspiration Volume <ul><li>80 samples/hour </li></ul><ul><li>Sampler or manual closed mode: </li></ul><ul><li>150 µL </li></ul><ul><li>Manual open mode: </li></ul><ul><li>85 µL </li></ul><ul><li>Capillary mode: </li></ul><ul><li>40 µL </li></ul>Throughput Data Storage <ul><li>10,000 samples (incl .graphics) </li></ul><ul><li>5,000 patients ’information </li></ul><ul><li>1,000 selective test orders </li></ul>
  7. 8. Interfaces <ul><li>Comprehensive QC files including </li></ul><ul><li>“ Current ”and “New ”lot feature </li></ul><ul><li>line printer, </li></ul><ul><li>graphic printer </li></ul>Quality Control Standard <ul><li>Rack sampler for 50 sample tubes </li></ul><ul><li>Hand-held barcode scanner </li></ul>
  8. 9. Fluorescent Flow Cytometry Makes the Difference <ul><li>A difference in managing </li></ul><ul><li>abnormal samples </li></ul><ul><li>Reliable detection of abnormal samples remains the most important issue in the hematology laboratory. </li></ul><ul><li>Accurate WBC, RBC, PLT and Differential results are essential to providing meaningful clinical information and in maintaining an efficient laboratory </li></ul>
  9. 10. Continue <ul><li>The xt-Series, which is comprised of the xt-2000i and the xt-1800i, use the identical and advanced Fluorescent Flow Cytometry technology and state-of-the-art cell counting methods. </li></ul><ul><li>The xt-Series extensive panel of hematology parameters provides more comprehensive data for better clinical decisions. </li></ul>
  10. 11. Continue <ul><li>Fluorescent enhanced </li></ul><ul><li>WBC Differential Counts </li></ul><ul><li>Fluorescent and Impendence </li></ul><ul><li>Platelet Counts* </li></ul><ul><li>Fluorescent Reticulocytes and </li></ul><ul><li>Immature Reticulocyte Fractions </li></ul>
  11. 13. Success of excellence <ul><li>Built on the modern Fluorescent Flow </li></ul><ul><li>Reliable system requiring minimum </li></ul><ul><li>Maintenance (just one shut-down cycle/day) </li></ul><ul><li>Excellent WBC differential with low review </li></ul><ul><li>rate due to fluorochrome staining of cells </li></ul>
  12. 14. Valuable information with diagnostic impact <ul><li>Reticulocyte enumeration including </li></ul><ul><li>maturation indices for efficient monitoring </li></ul><ul><li>of the erythropoietin activity </li></ul><ul><li>Fluorescent optical platelets for accurate plate-let counts even in case of mall RBC or large PLT </li></ul><ul><li>Cumulative patient data and Delta Check </li></ul>
  13. 15. Easy-to-use <ul><li>Windows 2000 graphical user interface </li></ul><ul><li>Q-Flags for quantitative flagging, </li></ul><ul><li>adjustable according to laboratory needs </li></ul><ul><li>Comprehensive software programs for internal and external quality control on board </li></ul>
  14. 16. Cost effective <ul><li>Four random access selective test profiles </li></ul><ul><li>(CBC,CBC/DIFF,CBC/RET,CBC/DIFF/RET) </li></ul><ul><li>Real time bi-directional Host communication </li></ul><ul><li>Network capability for integration </li></ul><ul><li>into a productive laboratory environment </li></ul>
  15. 17. Flexibility <ul><li>Information Processing Unit (IPU) with customizable display </li></ul>
  16. 18. Advantages of xt-2000 I IN DIAGNOSIS <ul><li>Abnormalities in the WBC (myeloid) line </li></ul><ul><li>Abnormalities in the WBC (lymphoid) line </li></ul><ul><li>Abnormalities in the RBC line </li></ul><ul><li>Abnormalities in the PLT line </li></ul>