RFT Tutorial - 5 How Do We Record Data Verification Point For Test Objects Using RFT - Presentation Transcript
RFT Tutorial - 5: How do we record data verification point for test objects using RFT?
This short tutorial describes a method of recording a data verification points for test
objects using RFT.
The purpose of creating verification points is to verify that a particular desired action has taken
place, or to verify the state of an object.
Step - 1: Start the Recording:
a) In RFT Java Scripting, click the "Record a Functional Tester Script" button on the Functional
Tester toolbar or the "File" > "New" > "Functional Tester Script Using Recorder" menu command
to start recording a script.
b) In RFT VB.NET Scripting, click the "Record a Functional Tester Script" button on the
Functional Tester toolbar or the "File" > "New" > "Add Script Using Recorder" menu command to
start recording a script.
Step - 2: Start the test application by clicking the "Start Application" button in the RFT Recording
Monitor.
Step - 3: Locate the list in the application which is intended to be tested.
Step - 4: In the RFT Recording Monitor, click the "Insert Verification Point or Action Command"
button on the toolbar.
Step - 5: On the "Select an Object" page of the Verification Point and Action Wizard, use the
Object Finder to select the list in the application intended to be tested. To test the entire list, we
can select any item in the list.
Step - 6: After selecting the list, we can see that one of the values shown on the Object
recognition properties grid is "list." Verify this "List" and click Next.
Step - 7: Go to the "Select an Action" page. Select the first option on the page i.e. "Perform Data
Verification Point" option.
Step - 8: In the "Data Value" field, select either of the following:
a) "List Elements" - to test the contents of the entire list. or
b) "Selected List Elements" test - to test only the items which are selected.
Step - 9: In the "Verification Point Name" field, accept the default suggestion, or provide a new
name of own choice.
Step - 10: Use the "Include Retry Parameters" to set a retry time for a verification point during
playback to check for its existence. This retry option shall be helpful to us when playback will fail
to find the verification point in the application.
Step - 11: After accepting or editing the above fields, click "Next" to continue.
Step - 12: After viewing or editing the list data, click "Finish" button. This will record the
verification point & it will be added to the script.
Step - 13: Finish the recording by clicking the "Stop Recording" button on the "Recording
Monitor" toolbar.
We can open the Verification Point Editor any time to edit the data recorded earlier.