Informed Prefetching in Distributed Multi-         Level Storage Systems                     Maen M. Al Assaf             ...
Background• Informed Prefetching.• Parallel multi-level storage system.• Distributed parallel multi-level storage system.•...
Informed Caching and Prefetching• My Research’s Core Reference: (TIP) R. Patterson, Hugo, G. Gibson, D. Stodolsky, and J. ...
Informed Caching and Prefetching• Applications can disclose hints about their  future accesses.• Invoke parallel storage p...
Informed Caching and Prefetching• Cost benefit model to determine # prefetching of buffer caches (TIP)     R. Patterson, H...
Multi-level storage system• Speed (Access Time) Vs. Capacity                              6
Parallel (Multi-levels) Storage Systems                             Cache• High I/O performance, bandwidth, scalability, a...
Distributed Parallel (Multi-level) Storage                 Systems• high I/O performance, bandwidth, scalability, and reli...
Research Motivations• The growing needs of multi-level storage  systems,• The I/O access hints offered by applications,  a...
Research Objectives• Minimizing the prefetching time (I/O Delays).• Reducing applications stalls and elapsed time.• Reduci...
My Solutions• iPipe: Informed Prefetching Pipelining for Multi-  levels Storage Systems.• IPO: Informed Prefetching Optimi...
Research Tasks              iPipe                                       IPO   Informed Prefetching Pipelining For        I...
iPipe and IPO Architecture            13
IPODS Architecture• Network and server latency. Data is stripped. T.Madhyastha; G. Gibson; C. Faloutsos: Informed prefetch...
Assumptions• Pipelined data are copies: 1) small portion 2)  do not move data back and forth.• Data initial placement in H...
Validations and Prototyping Test Bed• The following are our labs test bed devices:  – Memory: Samsung 3GB RAM Main Memory....
iPipe and IPO ParametersParameter           Description                      ValueBlock size          Block size in MB    ...
IPODS ParametersParameter              Description                      ValueBlock size             Block size in MB      ...
iPipe•   Parallel multi-levels storage system (SSD and HDD.)•   Pipeline data to uppermost level to reduce Tdisk.•   Reduc...
iPipe: Example Parameters• Assume:•   Tcpu+Thit+Tdriver = 1 Time Unit•   Thdd-cache = 5 Time Units•   Tss-cache = 4 Time U...
iPipe: Informed Prefetching       Tcpu+Thit+Tdriver = 1 Thdd-cache = 5 Xcache = 3              Tstall-hdd = 2 every 3 acce...
iPipe: Informed Prefetching       Tcpu+Thit+Tdriver = 1 Thdd-cache = 5 Xcache = 3              Tstall-hdd = 2 every 3 acce...
iPipe: Informed Prefetching  Stalls time = 16 time units & Elapsed time = 46 time units                  Tcpu+Thit+Tdriver...
iPipe: Pipelining Algorithm             24
iPipe: Pipelining AlgorithmStalls time = 9 time units & Elapsed time = 39 time units < 46 time units               Tcpu+Th...
iPipe: Performance Improvement                            - Elapse Time 1                        56% improvement in most c...
iPipe: Performance Improvement                      - Elapse Time 2   56%                56%                      56% impr...
iPipe: Performance Improvement                      - Elapse Time 3    Total simulation elapsed time when using 35 to 63 p...
Research Tasks              iPipe                                       IPO   Informed Prefetching Pipelining For        I...
IPO•   Parallel multi-levels storage system (SSD and HDD.)•   Pipeline data to uppermost level to reduce Tdisk.•   Reduce ...
IPO: Example Parameters• Assume:•   Tcpu+Thit+Tdriver = 1 Time Unit•   Thdd-cache = 5 Time Units•   Tss-cache = 4 Time Uni...
IPO: Informed Prefetching      Tcpu+Thit+Tdriver = 1, Thdd-cache = 5, Xcache = 2           Tstall-hdd = 3 every 2 accesses...
IPO: Informed Prefetching      Tcpu+Thit+Tdriver = 1, Thdd-cache = 5, Xcache = 2           Tstall-hdd = 3 every 2 accesses...
IPO: Informed Prefetching      Tcpu+Thit+Tdriver = 1, Thdd-cache = 5, Xcache = 2           Tstall-hdd = 3 every 2 accesses...
IPO: Informed Prefetching Stalls time = 45 time units & Elapsed time = 81 time units              Tcpu+Thit+Tdriver = 1, T...
IPO: Pipelining Algorithm     Tcpu+Thit+Tdriver = 1 Thdd-cache = 5 Tss-cache = 4 T hdd-ss = 8 Xcache = 2        Tstall-hdd...
IPO: Pipelining Algorithm     Tcpu+Thit+Tdriver = 1 Thdd-cache = 5 Tss-cache = 4 T hdd-ss = 8 Xcache = 2        Tstall-hdd...
IPO: Pipelining Algorithm     Tcpu+Thit+Tdriver = 1 Thdd-cache = 5 Tss-cache = 4 T hdd-ss = 8 Xcache = 2        Tstall-hdd...
IPO: Pipelining AlgorithmStalls time = 40 time units & Elapsed time = 76 time units < 81           Tcpu+Thit+Tdriver = 1 T...
IPO: Performance Improvement                                   - Elapse Time                          56% improvement in c...
IPODS• Parallel multi-levels storage systems can be  implemented on a distributed system.• Several storage nodes. Data are...
IPODS Architecture• Network and server latency. Data is stripped. T.Madhyastha; G. Gibson; C. Faloutsos: Informed prefetch...
IPODS: Performance Improvement                                    - Elapse TimeLASR2                        6% improvement...
Prototyping Development• We aim to validate our simulations’ results• 1000 I/O reading requests were sufficient to  show t...
iPipe Prototyping Xcache            1               3                5               7               9LASR1 With iPipe    ...
iPipe Prototyping Xcache            25              35              45              55              63LASR1 With iPipe    ...
IPO PrototypingXcache           1               3                    5               7LASR1 With IPO        560.1602      ...
IPODS PrototypingXcache             1              3                    5               7LASR1 With IPODS       48590.39  ...
Conclusion & Future Work• Conclusion:  – Informed prefetching shows better performance    when Tdisk is low.  – Reading da...
Upcoming SlideShare
Loading in...5
×

Informed prefetching in distributed multi level storage systems

1,357

Published on

In this dissertation, we present pipelined prefetching mechanisms that use application-disclosed access patterns to prefetch hinted blocks in multi-level storage systems. The fundamental concept in our approach is to split an informed prefetching process into a set of independent prefetching steps among multiple storage levels (e.g., main memory, solid state disks, and hard disk drives). In the first part of this study, we show that a prefetching pipeline across multiple storage levels is an viable and effective technique for allocating file buffers at the multiple-level storage devices. Our approaches (a.k.a., iPipe and IPO) extends previous ideas of informed prefetching in two ways: (1) our approach reduces applications' I/O stalls by keeping hinted data in caches residing in the main memory, solid state disks, and hard drives; (2) we propose a pipelined prefetching scheme in which multiple informed prefetching mechanisms semi-dependently work to fetch blocks from low-level (slow) to high-level (fast) storage devices. Our iPipe and IPO strategies integrated with the pipelining mechanism significantly reduce overall I/O access time in multiple-level storage systems. Next, we propose a third prefetching scheme called IPODS that aims to maximize the benefit of informed prefetches as well as to hide network latencies in a distributed storage systems. Finally, we develop a simulator to evaluate the performance of the proposed informed prefetching schemes in the context of multiple-level storage systems. We implement a prototype to validate the accuracy of the simulator. Our results show that our iPipe improves system performance by 56% in most informed prefetching cases, IPO and IPODS improve system performance by 56% and 6% respectively in informed prefetching critical cases across a wide range of real-world I/O traces.

Published in: Technology, Business
0 Comments
1 Like
Statistics
Notes
  • Be the first to comment

No Downloads
Views
Total Views
1,357
On Slideshare
0
From Embeds
0
Number of Embeds
2
Actions
Shares
0
Downloads
11
Comments
0
Likes
1
Embeds 0
No embeds

No notes for slide
  • Transition sentence: this is a transition slide for the background section – literature review, related work.
  • Move slide 38 here.
  • 15.2% saving
  • Informed prefetching in distributed multi level storage systems

    1. 1. Informed Prefetching in Distributed Multi- Level Storage Systems Maen M. Al Assaf Advisor: Xiao Qin Department of Computer Science and Software Engineering, Auburn University, Auburn, AL Download the dissertation at:http://www.eng.auburn.edu/~xqin/theses/PhD-Al-Assaf-Infomed- Prefetching.pdf The abstract of this dissertation can be found at: http://etd.auburn.edu/etd/handle/10415/2935
    2. 2. Background• Informed Prefetching.• Parallel multi-level storage system.• Distributed parallel multi-level storage system.• Prefetching pipelining to upper level.• Bandwidth limitation (Enough, Limited). 2
    3. 3. Informed Caching and Prefetching• My Research’s Core Reference: (TIP) R. Patterson, Hugo, G. Gibson, D. Stodolsky, and J. Zelenka: Informed prefetching and caching, In Proceedings of the 15th ACM Symposium on Operating System Principles, pages 79-95, CO, USA, 1995. 3
    4. 4. Informed Caching and Prefetching• Applications can disclose hints about their future accesses.• Invoke parallel storage parallelism.• Make the application more CPU-bound than I/O- bound. – Reducing I/O stalls. – Application’s Elapsed Time.• Tdisk: Disk read Latency (prefetching time). 4
    5. 5. Informed Caching and Prefetching• Cost benefit model to determine # prefetching of buffer caches (TIP) R. Patterson, Hugo, G. Gibson, D. Stodolsky, and J. Zelenka: Informed prefetching and caching, In Proceedings of the 15th ACM Symposium on Operating System Principles, pages 79-95, CO, USA, 1995. 5
    6. 6. Multi-level storage system• Speed (Access Time) Vs. Capacity 6
    7. 7. Parallel (Multi-levels) Storage Systems Cache• High I/O performance, bandwidth, scalability, and reliability.• Disk Arrays (enough / limited bandwidth). 7
    8. 8. Distributed Parallel (Multi-level) Storage Systems• high I/O performance, bandwidth, scalability, and reliability. T.Madhyastha; G. Gibson; C. Faloutsos: Informed prefetching of collective input/output requests, Proceedings of the 1999 ACM/IEEE conference on Supercomputing (CDROM), Portland, Oregon, 1999. 8
    9. 9. Research Motivations• The growing needs of multi-level storage systems,• The I/O access hints offered by applications, and• The possibility of multiple prefetching mechanisms to work in parallel. 9
    10. 10. Research Objectives• Minimizing the prefetching time (I/O Delays).• Reducing applications stalls and elapsed time.• Reducing prefetching time in distributed storage system. 10
    11. 11. My Solutions• iPipe: Informed Prefetching Pipelining for Multi- levels Storage Systems.• IPO: Informed Prefetching Optimization in Multi- levels Storage Systems. (Optimizes iPipe).• IPODS: Informed Prefetching in Distributed Multi- levels Storage Systems. 11
    12. 12. Research Tasks iPipe IPO Informed Prefetching Pipelining For Informed Prefetching Optimization in Multi-levels Storage Systems. Multi-levels Storage Systems IPODS PrototypingInformed Prefetching in Distributed Solution’s prototyping Results Multi-levels Storage Systems. 12 12
    13. 13. iPipe and IPO Architecture 13
    14. 14. IPODS Architecture• Network and server latency. Data is stripped. T.Madhyastha; G. Gibson; C. Faloutsos: Informed prefetching of collective input/output requests, Proceedings of the 1999 ACM/IEEE conference on Supercomputing (CDROM), Portland, Oregon, 1999. 14
    15. 15. Assumptions• Pipelined data are copies: 1) small portion 2) do not move data back and forth.• Data initial placement in HDD. 1) worst case 2) Larger.• Writes and data consistency. 15
    16. 16. Validations and Prototyping Test Bed• The following are our labs test bed devices: – Memory: Samsung 3GB RAM Main Memory. – HDD : Western Digital 500GB SATA 16 MB Cache WD5000AAKS. – SSD: Intel 2Gb/s SATA SSD 80G sV 1A. – Network Switch: Network Dell Power Connect 2824. 16
    17. 17. iPipe and IPO ParametersParameter Description ValueBlock size Block size in MB 10 MBTcpu+Thit+Tdriver Time to consume a buffer 0.00192 sThdd-cache Read time from HDD to cache 0.12 sTss-cache Reading time from SSD to cache 0.052 sThdd-ss Reading time from HDD to SSD 0.122 sMaxBW Maximum # of reading requests 15Xcache Number of prefetching buffers 1 – 63 / 1 - 15 17
    18. 18. IPODS ParametersParameter Description ValueBlock size Block size in MB 200 MBTcpu+Thit+Tdriver Time to consume a buffer 0.037 sThdd-network- cache Read time from HDD to cache 4.43 sTss-network-cache Reading time from SSD to cache 4.158 sThdd-ss Reading time from HDD to SSD 4.5 sMaxBW Maximum # of reading requests 15Xcache Number of prefetching buffers 1 - 15 18
    19. 19. iPipe• Parallel multi-levels storage system (SSD and HDD.)• Pipeline data to uppermost level to reduce Tdisk.• Reduce stalls, elapsed time.• Assumes: – Assume enough bandwidth, and scalability.• iPipe pipelines the informed prefetching process in the SSD. – Prefetching pipelining start (Pstart). – Prefetching pipelining depth (Pdepth). 19
    20. 20. iPipe: Example Parameters• Assume:• Tcpu+Thit+Tdriver = 1 Time Unit• Thdd-cache = 5 Time Units• Tss-cache = 4 Time Units• Thdd-ss = 8 Time Units• Xcache = 3• Tstall-hdd = 2 time units every 3 accesses.• Tstall-ss = 1 time unit every 3 accesses. 20
    21. 21. iPipe: Informed Prefetching Tcpu+Thit+Tdriver = 1 Thdd-cache = 5 Xcache = 3 Tstall-hdd = 2 every 3 accesses. 21
    22. 22. iPipe: Informed Prefetching Tcpu+Thit+Tdriver = 1 Thdd-cache = 5 Xcache = 3 Tstall-hdd = 2 every 3 accesses. 22
    23. 23. iPipe: Informed Prefetching Stalls time = 16 time units & Elapsed time = 46 time units Tcpu+Thit+Tdriver = 1 Thdd-cache = 5 Xcache = 3 Tstall-hdd = 2 every 3 accesses. 23
    24. 24. iPipe: Pipelining Algorithm 24
    25. 25. iPipe: Pipelining AlgorithmStalls time = 9 time units & Elapsed time = 39 time units < 46 time units Tcpu+Thit+Tdriver = 1 Thdd-cache = 5 Tss-cache = 4 T disk-ss = 8 Xcache = 3 Tstall-hdd = 2 every 3 accesses. Tstall-ss = 1 every 3 accesses. 25
    26. 26. iPipe: Performance Improvement - Elapse Time 1 56% improvement in most casesLASR2 56% 56%LASR1 56% 56% Total simulation elapsed time when using 1 to 9 prefetching buffers. 26
    27. 27. iPipe: Performance Improvement - Elapse Time 2 56% 56% 56% improvement 56% 56% Total simulation elapsed time when using 11 to 30 prefetching buffers. 27
    28. 28. iPipe: Performance Improvement - Elapse Time 3 Total simulation elapsed time when using 35 to 63 prefetching buffers. 28
    29. 29. Research Tasks iPipe IPO Informed Prefetching Pipelining For Informed Prefetching Optimization in Multi-levels Storage Systems. Multi-levels Storage Systems IPODS PrototypingInformed Prefetching in Distributed Solution’s prototyping Results Multi-levels Storage Systems. 29 29
    30. 30. IPO• Parallel multi-levels storage system (SSD and HDD.)• Pipeline data to uppermost level to reduce Tdisk.• Reduce stalls, elapsed time.• Assumes: – Limited bandwidth and scalability. – MaxBW = 15 – Pipelining depth = MaxBW - Xcache• IPO pipelines the informed prefetching process in the SSD. – Prefetching pipelining start (Pstart). – Next to Prefetch (Pnext). 30
    31. 31. IPO: Example Parameters• Assume:• Tcpu+Thit+Tdriver = 1 Time Unit• Thdd-cache = 5 Time Units• Tss-cache = 4 Time Units• Thdd-ss = 8 Time Units• Xcache = 2• Tstall-hdd = 3 time units every 2 accesses.• Tstall-ss = 2 time units every 2 accesses.• MaxBW = 5 concurrent reading requests. 31
    32. 32. IPO: Informed Prefetching Tcpu+Thit+Tdriver = 1, Thdd-cache = 5, Xcache = 2 Tstall-hdd = 3 every 2 accesses. 32
    33. 33. IPO: Informed Prefetching Tcpu+Thit+Tdriver = 1, Thdd-cache = 5, Xcache = 2 Tstall-hdd = 3 every 2 accesses. 33
    34. 34. IPO: Informed Prefetching Tcpu+Thit+Tdriver = 1, Thdd-cache = 5, Xcache = 2 Tstall-hdd = 3 every 2 accesses. 34
    35. 35. IPO: Informed Prefetching Stalls time = 45 time units & Elapsed time = 81 time units Tcpu+Thit+Tdriver = 1, Thdd-cache = 5, Xcache = 2 Tstall-hdd = 3 every 2 accesses. 35
    36. 36. IPO: Pipelining Algorithm Tcpu+Thit+Tdriver = 1 Thdd-cache = 5 Tss-cache = 4 T hdd-ss = 8 Xcache = 2 Tstall-hdd = 3 every 2 accesses. Tstall-ss =2 every 2 accesses. 36
    37. 37. IPO: Pipelining Algorithm Tcpu+Thit+Tdriver = 1 Thdd-cache = 5 Tss-cache = 4 T hdd-ss = 8 Xcache = 2 Tstall-hdd = 3 every 2 accesses. Tstall-ss =2 every 2 accesses. 37
    38. 38. IPO: Pipelining Algorithm Tcpu+Thit+Tdriver = 1 Thdd-cache = 5 Tss-cache = 4 T hdd-ss = 8 Xcache = 2 Tstall-hdd = 3 every 2 accesses. Tstall-ss =2 every 2 accesses. 38
    39. 39. IPO: Pipelining AlgorithmStalls time = 40 time units & Elapsed time = 76 time units < 81 Tcpu+Thit+Tdriver = 1 Thdd-cache = 5 Tss-cache = 4 T hdd-ss = 8 Xcache = 2 Tstall-hdd = 3 every 2 accesses. Tstall-ss =2 every 2 accesses. 39
    40. 40. IPO: Performance Improvement - Elapse Time 56% improvement in critical casesLASR2 56% 28%LASR1 0% Total simulation elapsed time when using 1 to 15 prefetching buffers. (MaxBW = 15) 40
    41. 41. IPODS• Parallel multi-levels storage systems can be implemented on a distributed system.• Several storage nodes. Data are stripped.• Tnetwork and Tserver are added to Tdisk .• IPO pipelining was used.• Assumes: – Limited bandwidth and scalability (depends on # of nodes). – MaxBW = 15 41
    42. 42. IPODS Architecture• Network and server latency. Data is stripped. T.Madhyastha; G. Gibson; C. Faloutsos: Informed prefetching of collective input/output requests, Proceedings of the 1999 ACM/IEEE conference on Supercomputing (CDROM), Portland, Oregon, 1999. 42
    43. 43. IPODS: Performance Improvement - Elapse TimeLASR2 6% improvement in critical cases 6% 4%LASR1 2% 0% Total simulation elapsed time when using 1 to 15 prefetching buffers. (MaxBW = 15) 43
    44. 44. Prototyping Development• We aim to validate our simulations’ results• 1000 I/O reading requests were sufficient to show the pattern.• Expect the results if simulated application were used in prototyping.• Simulators used LASR traces: – LASR1 : 11686 I/O Reading Requests – LASR2 : 51206 I/O Reading Requests• Compare the variations. 44
    45. 45. iPipe Prototyping Xcache 1 3 5 7 9LASR1 With iPipe 559.6273 190.3077 117.2071 86.52069 67.93586LASR1 no iPipe 1161.996 408.5916 259.0295 185.8635 151.6153 Xcache 1 3 5 7 9LASR1 With iPipe 607.612 202.537 121.522 86.8018 67.5125LASR1 no iPipe 1402.32 467.44 280.464 200.331 155.813 Motivational Example Xcache 11 13 15 17 19LASR1 With iPipe 57.32708 49.60041 44.31705 39.6187 36.04687LASR1 no iPipe 132.4959 117.7423 114.4435 93.45855 85.93546 Xcache 11 13 15 17 19LASR1 With iPipe 55.2375 46.7394 40.5075 35.7419 31.9796LASR1 no iPipe 127.484 107.871 93.488 82.4894 73.8063 (3-18%) Variation Prototyping Simulation 45
    46. 46. iPipe Prototyping Xcache 25 35 45 55 63LASR1 With iPipe 29.69927 28.52599 27.40414 24.96726 24.22578LASR1 no iPipe 79.44797 63.66883 59.02622 39.04141 37.02078 Xcache 25 35 45 55 63LASR1 With iPipe 24.3045 22.4358 22.4365 22.4369 22.4371LASR1 no iPipe 56.0928 40.0663 31.1627 25.4967 22.4371 Prototyping 35% Variation when Xcache = 63 Simulation (3-18%) Variation in most cases 46
    47. 47. IPO PrototypingXcache 1 3 5 7LASR1 With IPO 560.1602 236.8811 209.8946 169.9799LASR1 no IPO 1161.996 408.5916 259.0295 185.8635Xcache 1 3 5 7LASR1 With IPO 607.876 202.792 201.128 172.036LASR1 no IPO 1402.32 467.516 280.552 200.392Xcache 9 11 13 15LASR1 With IPO 147.101 131.3518 116.7431 114.4435LASR1 no IPO 151.6153 132.4959 117.7423 114.4435Xcache 9 11 13 15LASR1 With IPO 155.768 127.448 107.878 93.5731LASR1 no IPO 155.87 127.547 107.878 93.5731 (3-18%) VariationPrototypingSimulation 47
    48. 48. IPODS PrototypingXcache 1 3 5 7LASR1 With IPODS 48590.39 16377.7 10383.65 7604.548LASR1 no IPODS 51768.98 17772.19 10705.66 7803.21Xcache 1 3 5 7LASR1 With IPODS 48590.9 16200 9933.42 7246.72LASR1 no IPODS 51769 17259.2 10357.2 7397.95Xcache 9 11 13 15LASR1 With IPODS 6061.563 5003.758 4264.514 3750.33LASR1 no IPODS 6151.16 5022.374 4276.2 3750.33Xcache 9 11 13 15LASR1 With IPODS 5750.29 4704.81 3982.53 3454.88LASR1 no IPODS 5754.39 4708.83 3982.53 3454.88 (1-8%) VariationPrototypingSimulation 48
    49. 49. Conclusion & Future Work• Conclusion: – Informed prefetching shows better performance when Tdisk is low. – Reading data from upper levels is faster. – Three solutions (iPipe, IPO, IPODS). – Elapsed time improvement in about 56% and 6%. – Many Contributions.• Future work: – Data migration – More experimental work 49