• Share
  • Email
  • Embed
  • Like
  • Save
  • Private Content
Sun fire x2250 technical training presentation
 

Sun fire x2250 technical training presentation

on

  • 845 views

 

Statistics

Views

Total Views
845
Views on SlideShare
845
Embed Views
0

Actions

Likes
1
Downloads
21
Comments
0

0 Embeds 0

No embeds

Accessibility

Categories

Upload Details

Uploaded via as Adobe PDF

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

    Sun fire x2250 technical training presentation Sun fire x2250 technical training presentation Presentation Transcript

    • Sun Fire X2250Technical Training v1.4Token # 535321Ron GrahamSystems Technical MarketingSun Microsystems
    • Agenda • Introduction • Architectural overview • Hardware • Software • Remote managementPage: 2 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Sun Fire X2250 Compute Entry x64 Intel Rackmount ● Two Intel Xeon processors (5200 series 1U 2-Socket dual-core or 5400 series quad-core) ● Eight FB-DIMM slots (DDR2-667/800, 32GB max) I/O ● One PCIe x16 slot ● Two 3.5-inch 7,200 RPM SATA HDD ● Two Gigabit Ethernet ports ● Tray load slim DVD ● Five USB 2.0 ports Ideal for HPC and Web 2.0 Hardware RAS applications ● Remote management with ILOM 2.0 ● RAID 0, 1 ● Trusted Platform Module (TPM) ● DIMM Mirroring and Sparing Software ● Solaris, Linux, and WindowsPage: 3 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Sun Fire X2200 M2 vs X2250 Feature Sun Fire X2200 M2 Sun Fire X2250 Form Factor 1RU 1RU Processor 2 AMD Opteron 2000 series 2 Intel Xeon 5000 sequence (dual- or quad-core) (dual- or quad-core) I/O Chipset nVidia nForce Professional 3600 Intel 5400 Chipset CPU to I/O Interconnect HyperTransport 2.0 Front Side Bus Memory Type ECC registered DDR2-667 FB DIMM DDR2-667/800 Memory Capacity 16 DIMM slots, 64GB max 8 DIMM slots, 32GB max (512MB, 1GB, 2GB, & 4GB) (1GB, 2GB, & 4GB) Storage Up to 2 SATA or SAS HDD Up to 2 SATA HDD Optical Drive DVD-ROM or DVD-RW DVD-ROM or DVD-RW Service Processor Aspeed AST2000 Aspeed AST2000 Remote Management Embedded LOM ILOM 2.0 Network Management Shared 10/100 with Broadcom port Dedicated 10/100 port through AST2000 PCI Express 2 x8 PCIe or 1 x16 PCIe (1.0) 1 x16 PCIe (1.0) Ethernet 2 nVidia GigE, 2 Broadcom GigE 2 Intel GigE USB 2.0 6 (2 front, 4 rear) 5 (2 front, 2 rear, 1 internal) Serial Ports 1 serial DB-9 male port 1 TIA/EIA-232-F asynchronous RJ45 port Power Supply 450 Watt 500 Watt Operating System Solaris, RedHat, SuSE, Windows, Solaris, RedHat, SuSE, & Windows & VmwarePage: 4 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Sun Fire X2250 Competitive Landscape Competitors → HP Dell Dell IBM Sun Fire X2250 Features ↓ DL160 G5 PE SC1435 PE1950 X3550 Rack Space 1U 1U 1U 1U 1U CPU Type Intel Xeon 5000 Intel Xeon 5000 AMD Opteron 2200 Intel Xeon 5000 Intel Xeon 5000 Broadcom HT-2100 Chipset Intel 5400 Intel 5400 Intel 5000X Intel 5000X and HT-1000 DIMMs / Chassis 8 FBDIMM 8 FBDIMM 8 RDDR2 8 FBDIMM 8 FBDIMM Max Memory 32GB 32GB 32GB 32GB 32GB Memory FB DDR2-667/800 FB DDR2-667 RDDR2-667 FB DDR2-667 FB DDR2-667 2x 3.5” SATA/SAS HDD 2x 3.5” SATA 4x 3.5” SATA/SAS 2x 3.5” SATA/SAS 4x 2.5” SAS 4x 2.5” SAS GbE Ports 2x GbE 2x GbE 2x GbE 2x GbE 2x GbE Expansion Slots 1x PCIe x16 2x PCIe x16 (2.0) 1x PCIe x8 or PCI-X2x PCIe x8 or PCI-X 2x PCIe or PCI-X I/O ports USB, Serial USB, Serial,PS/2 USB, Serial USB, Serial USB, Serial PSU 500W 650W 600W 2x670W 2x670W Management ILOM 2.0 LO 100i IPMI 2.0 IPMI 2.0 IPMI 2.0Page: 5 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Agenda • Introduction • Architectural overview • Hardware • Software • Remote managementPage: 6 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Sun Fire X2250 Architecture Overview X2250 is based on Intel Stoakley Platform • Intel Xeon 5000 sequence processors > Intel Quad Core Xeon 5400 series processor (Harpertown) > Intel Dual Core Xeon 5200 series processor (Wolfdale-DP) • Intel 5400 Chipset > Intel 5400 Chipset Memory Controller Hub (MCH) (Seaburg) > Intel 632xESB I/O Controller Hub (IOCH) For more details on Intel Platforms, see SunWIN document #520953 “Intel Codenames Explained”Page: 7 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Sun Fire X2250 – Block Diagram DIMM B1 IDE DIMM B0 CD/DVD 1x Internal USB 2.0 DIMM A1 2x Rear Intel Xeon DIMM A0 USB 2.0 5200/5400 5.3 GB/s 5.3 GB/s Channel B Channel A 2x Front USB 2.0 10.5 GB/s PCIe Dual FSB to MCH MCH ESI (PCIe) IOH Intel Xeon 1333/1600 MT/s Intel 5400 ESB-2 5200/5400 GB Ethernet 10.5 GB/s 0&1 PCI 32-bit 33 MHz Channel C Channel D SATA 5.3 GB/s 5.3 GB/s PCIe x16 Serial RJ-45 DIMM C0 DIMM C1 Management USB 10/100 Ethernet DIMM D0 USB VGA Video DIMM D1 2x SATA PCIe x16 - 1 HDDsPage: 8 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Intel Xeon 5200/5400 Series 45nm Hi-k (penryn) next generation Intel Core microarchitecture • Intel Xeon 5400 series (Harpertown) > 2x 6MB L2 cache, quad-core > 2.0GHz – 3.2GHz clock speeds > 1333 and 1600 MT/s FSB • Intel Xeon 5200 series (Wolfdale) > 6MB L2 cache, dual-core > 1.86GHz – 3.4GHz clock speeds > 1066, 1333, and 1600 MT/s FSB • Single or dual processor configurationsPage: 9 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Intel 5400 Chipset MCH (Seaburg) • Two independent Front Side Bus (FSB) connections > FSB speed of 1066/1333/1600 MT/s > Integrated 24MB snoop filter > Quad pumped • Four channels of Fully Buffered DIMM (FBD) memory with 8 DIMMs/channel > FBD DDR2-533/667/800, up to 128GB > Memory sparing support (post RR) > No memory mirroring support • Nine x4 PCIe 2.0 ports, supporting configurations of x8 and x16 slots > PCIe 1.0 support only • Intel 631x/632x IOCH connectivityPage: 10 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Intel 632x ESB IOCH • Dual-gigabit MAC IDE > Compliant with 1000 Mb/sec CD/DVD Ethernet/802.3z spec 1x Internal USB 2.0 > Multi-speed operation: 10/100/1000Mb/s 2x Rear USB 2.0 • Integrated Serial ATA controller 2x Front USB 2.0 > Six ports, data transfer rates up to 3.0 Gbs (300 MB/s) IOH • Integrated IDE controller ESB-2 GB Ethernet 0&1 PCI 32-bit 33 MHz > Ultra ATA/100/66/33 SATA • USB 2.0 Serial RJ-45 • PCI v2.3 Bus Interface USB Management 10/100 Ethernet > PCI v1.0 support only USB VGA Video 2x SATA HDDsPage: 11 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Snoop Filter Overview > Snoop Filter helps lower FSB utilization and improves FSB headroom > Snoop Filter (SF) is a cache-tag structure stored in the chipset – Keeps track of the status of cache lines in the processor caches – Contains only TAGs and status of cache lines and NOT the data – Filters all unnecessary snoops to the remote bus > Snoop Filter decreases the FSB utilizations C C C C C C C C – Forwards only requests that need to be snooped on O R O R O R O R O R O R O R O R the remote bus E E E E E E E E 1 2 3 4 1 2 3 4 – Cache line that could potentially be present in a dirty state on the remote bus 6MB Cache 6MB Cache 6MB Cache 6MB Cache – Cache lines that need to be invalidated – Filters all the other processor snoops & large fraction of IO-snoops – All I/O-bound applications benefit automatically 24MB Snoop Filter Cache – No source code changes or recompile required Intel® 5400 chipsetPage: 12 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Agenda • Introduction • Architectural overview • Hardware • Software • Remote managementPage: 13 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Sun Fire X2250 – Internal Layout 2 Blowers cooling CPUs and DIMMs High Efficiency Power Supply 2 SATA Drives DVD 8 FB-DIMM Slots 1 PCI-Express Expansion Slot 2 Intel Xeon 5200/5400 CPUsPage: 14 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Sun Fire X2250 – Chassis Design 3.5-inch SATA HDD Locator light Status LEDs Power button USB ports Tray load DVD 3.5-inch SATA HDD 500W PSU NET MGT SER MGT USB ports HD-15 VGA 2 Intel GigE Ethernet x16 PCIe slotPage: 15 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Sun Fire X2250 – Storage • Two internal 3.5-inch 7,200 RPM SATA HDD > Intel SATA controller > RAID 0,1 – Windows only > 250 GB, 500 GB, and 1 TB disk drives available – Mixing different density disk drives is supported • Internal tray load DVD • PCIe based HBAs > Sun StorageTek PCI Express x4 Dual Channel Ultra320 SCSI Host Bus Adapter > Sun StorageTek PCIe Enterprise 4Gb Fiber Channel Host Bus Adapter, Dual channel > 4Gb Dual Fiber Channel PCIe Host Bus Adapter, Emulex > Sun StorageTek (TM) PCIe SAS Host Bus Adapter, 8 port pass-thru > 4Gb Single Fiber Channel PCIe Host Bus Adapter, Emulex > Sun StorageTek PCIe Enterprise 4 Gb Fiber Channel Host Bus Adapter, Single ChannelPage: 16 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Sun Fire X2250 - I/O ports • Three network ports > Two 10/100/1000 RJ45 connected to the host MACs provided by Intel ESB, brought out through Gilgal PHY > One 10/100 RJ45 to the AST2000 • One serial port > TIA/EIA-232-F asynchronous RJ45 port routed through AST2000 • 5+2 USB ports > Two USB 2.0 front, two rear, one internal, two wired to AST2000 • One video port > Analog HD15 VGA connectorPage: 17 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • PCIe Expansion Slot • PCI-Express slot > Low Profile form factor > PCIe v1.0 > x16 electrical, x16 mechanical > Right-angle riser > Connected to MCH PCIe RiserPage: 18 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Dimensions and Rack Mount • Same chassis as Sun Fire X2100/X2200 M2 > Height x Width x Depth – 43 x 425.5 x 633.7 mm – 1.7 x 16.8 x 25.4-inches > Maximum weight: 27.2 lbs (13.3 kg) • Two 4-post rack mount options > Standard slide rail kit > Tool-less slide rail kit – Snaps into most 3rd party racks > Cable management kit – Ordered separately from slide rail kitsPage: 19 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Sun Fire X2250 – Power, Cooling • One 500 Watt power supply > Non-redundant, non-hot swappable > High efficiency, 80+ > 120/240V auto sensing > Built-in 2 cooling fans • Three internal fans > Two blowers for main chassis area (CPU & memory) > One fan for PCIe cardsPage: 20 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Sun Fire X2250 – Cooling and Fans • Cooling Front to Back • Airflow provided by 3 Fans + 2 Blowers > 2 blowers forcing air to CPUs/DIMMs area > 1 fan for PCIe slot area > 2 fans in PSU 2 Air Blowers Fan for PCIe slot areaPage: 21 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Sun Fire X2250 Options Intel Xeon Processor Choices Infiniband, 10GbE, Fiber Channel, SCSI, SAS, Crypto Quad Core ● Sun Dual Port 4x Infiiniband (X1236A)-Z ● X5472 ( 1600MHz FSB, 3.00GHz,120W) ● Sun Dual Port DDR IB Host Channel Adapter (X4127A-Z) ● E5462 ( 1600MHz FSB – 2.80GHz – 80W) ● Sun Dual-Port Multi-threaded 10GbE NIC (X1027A) ● X5460 ( 1333MHz FSB – 3.16GHz – 120W) ● Sun Single-Port (Intel 82598 Controller) (X1106A-Z) ● E5405 ( 1333MHz FSB – 2.0GHz – 80W) ● Sun Dual-Port (Intel 82598 Controller) (X1107A-Z) Dual Core ● Sun StorageTek dual-channel Ultra320 (SG-XPCIE2SCSIU320Z) ● X5272 (1600MHz FSB – 3.4GHz) ● Sun StorageTek 8-port SAS HBA (SG-XPCIE8SAS-E-Z) ● Sun StorageTek Dual-channel 4Gb FC HBA (SG-XPCIE2FC-QF4) 50W Quad Core ● L5420 ( 1333MHz FSB – 2.5GHz) ● Emulex 4Gb Dual FC HBA (SG-XPCIE2FC-EM4) ● Sun StorageTek 4Gb Single-channel FC HBA (SG-XPCIE1FC-EM4) ● Sun StorageTek 4Gb Single-channel FC HBA (SG-XPCIE1FC-QF4) Memory Choices ● Sun 2-port Gigabit Ethernet NIC Copper (X7280A-2) ● 8GB 800MHz: 2x4GB ● Sun 2-port Gigabit Ethernet NIC Fiber (X7281A-2) ● 4GB 800MHz: 2x2GB ● Sun 4-port Gigabit Ethernet NIC Copper (X4446A-2) ● 8GB 667MHz: 2x4GB ● Sun Crypto Accelerator 6000 SSL/IPsec Accelerator (X600A) ● 4GB 667MHz: 2x2GB ● Storage Choices Standard Configurations ● One X5472, 2x 4GB 800MHz (X2250-14-H300-24-A) - $3,395 ● 1TB SATA 7,200rpm ● One E5460, 2x 2GB 667MHz (X2250-14-H316-22-A) - $2,995 ● 500GB SATA 7,200rpm ● One E5405, 2x 2GB 667MHz (X2250-14-M200-22-A) - $1,495 ● 250GB SATA 7,200rpm ● One L5420, 2x 2GB 667MHz (X2250-14-L250-22-A) - $1,995 ● DVD-ROM or 8x double-layer DVD burner ● JBODs, RAID Arrays, Tape options (40+)Page: 22 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Agenda • Introduction • Architectural overview • Hardware • Software • Remote managementPage: 23 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Sun Fire X2250 – Operating Systems Operating System Notes Solaris 10 8/07 Pre Installed Red Hat Enterprise Linux 4.0 AS Update 6 64 bit version Red Hat Enterprise Linux 5.0 AS Update 1 64 bit version SuSE Linux Enterprise Server 10 w/ SP1 64 bit version Microsoft Server 2003 Standard & Enterprise 32 & 64 bit version VMWare ESX 3.5, ESXi Not SupportedPage: 24 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Sun Fire X2250 – Tools & Drivers • Hardware Diagnostics (PC-Check) > DOS based diagnostics utility, run from CD/DVD > Writes results to diagnostics partition on primary HDD • System BIOS/SP flash update utility > Updates BIOS and SP together • OS specific drivers > Post-installation scripts for each OS > Microsoft Windows 2003 reburn scriptPage: 25 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Agenda • Introduction • Architectural overview • Hardware • Software • Remote managementPage: 26 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Sun Fire X2250 – Remote Management • ILOM 2.0 > GUI and CLI based management > Remote KVMS > User access control – Local users, LDAP, Active Directory • Service Processor based on Aspeed AST2000 > One 10/100 BaseT Ethernet (RJ45) > Serial port multiplexed with system serial port > BIOS flash upgrades via SP or hostPage: 27 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Aspeed AST2000 • Embedded 200MHz ARM CPU • BMC controller with IPMI 2.0/1.5 • Graphics controller > VGA/2D controller > 1600 x 1200 @ 60Hz • Video Redirection over IP • Storage over IP • Single 10/100 Mbps MACPage: 28 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Sun Fire X2250 – Management Interfaces • All management interfaces call the same underlying system management functions, allowing the user to choose preferred access method > Secure web browser (GUI) – Remote Console application > Secure Shell (SSH) command line (DMTF SMASH CLP) > Serial port through terminal server or direct host attach > IPMI v2.0 command interface > Simple Network Management Protocol (SNMP)Page: 29 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Sun Fire X2250 – RKVMS • Remote keyboard, video, mouse, and storage > Full video passed to remote application – Max resolution 1600x1200 > Connect local CD/DVD or .iso image to host through SP • Java Web Start application > Downloaded through secure web connectionPage: 30 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Sun Fire X2250 – System Sensors • The service processor can monitor and report status and errors on the following system components > CPU core voltage > Memory voltage > System 3.3V, 5V, and 12V > System fans > CPU temperature > Chassis temperaturePage: 31 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only
    • Sun Fire X2250Technical TrainingRonald GrahamRonald.Graham@sun.com