Grounding & Lightning Protection SystemOn Bekasi Power CCPP 130MW                                          Created by R. B...
Protection: Human        “Memproteksi manusia dan peralatan dalam              operasionalnya di wilayah PLTGU Bekasi Pow...
V1 > V2 > V3 > V4          Voltage difference in a spot to          another caused electron to move           it caused e...
V1 = V2 = V3 = V4                      ΔV = 0       Air Terminal       Down Conductor           Building      Grounding Gr...
   Grounding     Membuat bidang eq potensial dalam kawasan     semerata mungkin (Create different potential     (voltage...
Grounding Cable: BCC 50 mm²Distance between grounding tap: 7-11m
Equipment 1                              Equipment 2                                                        Bond to Equipm...
Control Room               GTG
Power House              HRSG   GTG
Lightning protection system on Bekasi Power Plant [beta]
Lightning protection system on Bekasi Power Plant [beta]
Lightning protection system on Bekasi Power Plant [beta]
Lightning protection system on Bekasi Power Plant [beta]
Lightning protection system on Bekasi Power Plant [beta]
Lightning protection system on Bekasi Power Plant [beta]
Lightning protection system on Bekasi Power Plant [beta]
Lightning protection system on Bekasi Power Plant [beta]
Lightning protection system on Bekasi Power Plant [beta]
Lightning protection system on Bekasi Power Plant [beta]
Lightning protection system on Bekasi Power Plant [beta]
Lightning protection system on Bekasi Power Plant [beta]
Lightning protection system on Bekasi Power Plant [beta]
Lightning protection system on Bekasi Power Plant [beta]
Upcoming SlideShare
Loading in...5
×

Lightning protection system on Bekasi Power Plant [beta]

808

Published on

Lightning Protection philosophy implemented on Bekasi Power Combined Cycle Power Plant, Bekasi, Indonesia.
I create this with supervisory of my senior engineer. Any suggestions/critics welcomed.
Still in development.

Published in: Education, Technology, Business
2 Comments
2 Likes
Statistics
Notes
No Downloads
Views
Total Views
808
On Slideshare
0
From Embeds
0
Number of Embeds
1
Actions
Shares
0
Downloads
0
Comments
2
Likes
2
Embeds 0
No embeds

No notes for slide
  • Memproteksimanusiadanperalatandalamoperasionalnyadiwilayah PLTGU Bekasi Power.
  • Lightning protection system on Bekasi Power Plant [beta]

    1. 1. Grounding & Lightning Protection SystemOn Bekasi Power CCPP 130MW Created by R. Bambang Widiatmoko wheeqo.web.id
    2. 2. Protection: Human “Memproteksi manusia dan peralatan dalam operasionalnya di wilayah PLTGU Bekasi Power” Equipment
    3. 3. V1 > V2 > V3 > V4 Voltage difference in a spot to another caused electron to move  it caused electric shockV1 V2 V3 V4
    4. 4. V1 = V2 = V3 = V4 ΔV = 0 Air Terminal Down Conductor Building Grounding GridV1 V2 V3 V4
    5. 5.  Grounding  Membuat bidang eq potensial dalam kawasan semerata mungkin (Create different potential (voltage) the same in all area) Down Conductor & Air Terminal  Memasang penyalur petir (Install air terminal)  Memanfaatkan ketinggian bangunan (Using tall building)
    6. 6. Grounding Cable: BCC 50 mm²Distance between grounding tap: 7-11m
    7. 7. Equipment 1 Equipment 2 Bond to Equipment Armored Cable Grounding Grid Bond to Grounding Grid
    8. 8. Control Room GTG
    9. 9. Power House HRSG GTG

    ×