Baykee CHP series industrial low frequency ups 3 phase

  1. 1. CHPCHPCHPCHP SeriesSeriesSeriesSeries ThreeThreeThreeThree PhasePhasePhasePhase OnlineOnlineOnlineOnline upsupsupsups (10kva~120kva)(10kva~120kva)(10kva~120kva)(10kva~120kva) SalientSalientSalientSalient Features:Features:Features:Features: CHP Series 3/3 Online UPS --- Intelligent & Digital UPS BriefBriefBriefBrief Introduction:Introduction:Introduction:Introduction: CHP series ups includes the 10 KVA to 400 KVA (3 phase input & 3 phase output) double conversion On-Line UPS with an isolation transformer at Output. The Load is supplied continuously by the inverter with clean, stabilized and regulated sine wave output power. Input & Output filters increase the immunity of load from power disturbances and surges. CHP series - Double Conversion Online UPS is useful for mission critical applications like IT, Data Centers, Hospitals, Precision Instrument, Intelligent Equipments and Industrial Automation etc.---Applications Thanks to state-of-the-art microprocessor / DSP based outstanding advanced technology design. CHP series Double Conversion Online UPS can be used for monitoring various parameters of the UPS and also can be useful for remote monitoring / control on the web by adding SNMP Card ( Optional ). � Pure sine wave output, true on-line dual conversion design � Adopt 4 layer PCB, and SMD technology � High efficiency IGBT (Insulated Gate Bipolar Transistor) inverter technology. The sixth generation low-exhaust and big-power IGBT with excellent high speed switch feature, high voltage feature and large current feature. Drives by electric voltage, only need small control power. The sixth generation with lower saturation voltage, the inverter has high efficiency, low temperature, high reliability. � Touch screen display, with simple operation and Intuitive data, optional display language and logo. � Set work modes on the display directly, UPS mode, ECO mode, EPS mode � Intelligent detecting function This system microprocessor can continually online detect power status, the breaker status and all the working status of the circuit � Excellent load feature Completely capable to load from 0-100% while no need to change to bypass, which make sure the output reliable. � Isolation Transformer in output for Better Performance � Static & Manual Bypass Inbuilt � Three phase separately control, realizes the control of instantaneous over-loading balance, so as to reach 100% unbalanced load. � DC cold start function When mains failure, can directly use the battery to start the ups until the battery discharge to low voltage, when mains recover, can self start UPS � Generator compatible According to the real electric circumstances, UPS can be compatible to the generator, highly improve the generator input efficiency, save the energy. � Intelligent communication With RS232 and RS485 standard collocation, optional SNMP and dry contact � Perfect protection. Input/output over/low voltage protection, input surge protection, phase sequence protection, battery over charge/discharge
  2. 2. Specifications:Specifications:Specifications:Specifications: model CHP 3010K CHP 3020K CHP 3030K CHP 3040K CHP 3050K CHP 3060K CHP 3080K CHP 3100K CHP 3120K Nominal capacity (KVA) 10KVA 20KVA 30KVA 40KVA 50KVA 60KVA 80KVA 100KVA 120KVA Working mode Low frequency double conversion True Online Phase number 3L+N+G Input power factor ≥0.9(pulse rectifier), ≥0.99(12 pulses rectifier) Rectifier(Input) Input rated voltage 190V/200V/208V or 380V/400V/415V/ range ±25% Input nominal frequency 50Hz±10%,60Hz±10% Input overtone current 6pulses rectifier<30%, 12pulses rectifier plus filter <5% Output ripple wave < 2% Soft start 0~100% 5sec Charging Charge mode Constant current first then constant voltage, charge with temperature compensation, automatic switch of even charge and float charge, programmable timing battery charge-discharge automatic maintenance Float charging voltage 432VDC Equalized charging voltage 464VDC Temperature compensation voltage 3mV/℃(cell battery) Charging current 0.1C(automatic adjust according to battery capacity) 10A~50A Adjustable Charging power 20%of rated capacity Battery type maintenance free lead-acid battery capacity 7~999AH settable (capacity vary with power) battery number 12V-32pcs, 2V-192pcs (nominal voltage 384VDC) Invertor Phase number 3L+N Rated power Rated capacity×0.9 Nominal voltage 190V/200V/208V or 380V/400V/415V/ Output voltage stability ±1%(steady load), ±3%(fluctuation of load) protection, short circuit protection, over-temperature protection and so on, as well as alarm function. � Selectable battery inspection module Can test the single parameter and display on the LCD, battery failure will immediately alarm and inform the administrator � High-powered dynamic feature Adopt kinds of feedback control such as instantaneous control mode and virtual value, not only reach the high dynamic adjustment, but also reduce the output voltage distortion. � Optional input harmonic filter or 12 pulse rectifier Effectively restrain the input THD,raise UPS input power factor, reduce the input THD current
  3. 3. Frequency stability 50Hz,60Hz<±0.5%(desynchronised) Factor of wave crest > 3:1 Output Waveform distortion degree sine wave,linear load < 3%, non-linear load<5% Dynamic feature Transient voltage<±5%(jump form 0% to 100%),instant recovery time<10ms Unbalance load voltage < ±5% Overload protection 115% normal work, 125%60 min, 150%10min, 200%10s Invertor efficiency > 92%(full load) > 93%(full load) Bypass Phase number 3L+N Input nominal voltage 190V/200V/208V or 380V/400V/415V/ Output nominal voltage 190V/200V/208V or 380V/400V/415V/ Switching time 0ms(adopted static switch ) Protection Input protection Voltage, frequency ultra limit, phase wrong, phase lost Output protection Over current, short circuit, power factor low Battery protection Over-charge, Over-discharge Overheat protection Environmental thermal, inverter overheat protection Hardware fault protection Auxiliary power supply abnormal, breaker trip, fuse break, power device over current or overvoltage System specifications Economic running mode Economic mode available, overall efficiency reach up to 98% Audio alert function Any failure will be alerted Work environment Ambient temperature: 0~40℃,relative humidity: 30%~90%,altitude: <1000M (power reduce 1% every 100M raised, 4000M utmost) Cooling method Forced ventilation Telecom interface RS232,RS485. Dry contact interface, Optional SNMP card (network remote control) Redundancy function Cascade or multiple hot spare Anti-surge 10/700μS, 5KV; 8/20μS, 20KA Protection level IP31 Safety performance I/O on ground resistance (3000VAC), stray current less than 3.5mA; insulation resistance exceeding 2MΩ(500VDC) Noise(dB) 48~55 55~60 60~65 Mechanical dimension (W×D×H) mm 600×620×1250 700×620×1530 980×800×1800 Package dimension (W×D×H) mm 670*690*1460 800*690*1760 1050*870*2030 Net Weight (Kg) 205 265 310 407 485 506 770 913 937 Gross Weight (Kg) 236 296 342 447 525 520 812 955 980 AnyAnyAnyAny CustomisedCustomisedCustomisedCustomised parametersparametersparametersparameters areareareare availableavailableavailableavailable
  4. 4. BAYKEE NEW ENERGY TECHNOLOGY INCORPORATED COMPANY --- All Right Revised

×