860 dspi upstream_level_measurement_appnote
Upcoming SlideShare
Loading in...5
×
 

860 dspi upstream_level_measurement_appnote

on

  • 193 views

 

Statistics

Views

Total Views
193
Views on SlideShare
193
Embed Views
0

Actions

Likes
0
Downloads
1
Comments
0

0 Embeds 0

No embeds

Accessibility

Categories

Upload Details

Uploaded via as Adobe PDF

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

860 dspi upstream_level_measurement_appnote 860 dspi upstream_level_measurement_appnote Document Transcript

  • Application Note 860 DSPi Upstream Level MeasurementThis paper describes the upstream level measurement on the 860DSPi. This level measurement is displayed on the lower right of thePING menu as well as on the CMSTAT Menu. This value was displayed2 dB lower in firmware versions from V4.9.1.0 to V4.12.1.0 due to anattempt to add a calibration factor to compensate for the loss from theSLM input connector to the internal cable modem. Starting in theV5.2.1.0 Release, this correction factor was revised to be a correctioncurve taking into account the actual loss in this same Rf path.The upstream level measurement is tested by the following procedure. 1. Connect the Test setup as follows: 6 dB TAP A B 2. Enter the Setup Menus on the first 860 DSPi “A” and set the “Network Port” to “Internal Cable Modem” and set the “Show Modem Info” to “Yes” For Additional Help Contact Trilithic Applications Engineering 860 DSPi Upstream Level Measurement 1-800-344-2412 or 317-895-3600 P/N 0010275019 – Rev 8/07 support@trilithic.com or 1 of 2 www.trilithic.com Copyright © 2007 Trilithic, Inc. All Rights Reserved.
  • Application Note 3. Enter the Ping Menu on the first 860 DSPi “A” and let the unit log on to the CMTS. Once the unit logs on to the CMTS, start pinging the CMTS at a 100 msec rate. If you enter “0.0.0.0” for the Host IP, the 860 DSPi will use the DHCP server as its ping destination and this is usually the CMTS or near the CMTS. The display should look like following picture. Note the number in the bottom right is the cable modem upstream transmit level. This is the same value that is displayed on the CMSTAT menu. 4. Setup the second 860 DSPi “B” as shown in the screen. Make sure that the RBW is set to your upstream bandwidth (in our case 16QAM, BW=3.2MHz). You may need to set the trigger edge to (auto) until the screen looks good. 5. The peak power level is shown as +50 in these two captures with the front edge being at around +48. If we then add back in the +6 dB for the TAP, the modem should be transmitting around +54. Now, where we measure the power is the question, the flat front end corresponds to the initial fixed symbols and looks like a good place.For Additional Help ContactTrilithic Applications Engineering 860 DSPi Upstream Level Measurement1-800-344-2412 or 317-895-3600 P/N 0010275019 – Rev 8/07support@trilithic.com or 2 of 2www.trilithic.com Copyright © 2007 Trilithic, Inc. All Rights Reserved.