Thong so ky thuat dan lanh fxmq + lo mo tran Thong so ky thuat dan lanh fxmq + lo mo tran Document Transcript

  • 248 Notes) 1. Location of MANUFACTURES LABEL: 4. Space for Service Works Control box surface According to any one of below 1)~3), secure a space 2. Mount the air filter at the suction side. for service works, such as, checking and maintenance Select its colorimethod (gravity method) of control box and drain pumps, etc. Dimensions 50% or more. 1) One inspection hatch (450 × 450) on the control box 3. Do not locate things should not be wet side and a space of 300mm or more under the unit. 16-φ 4.7 hole 27 631 under the indoor unit. (Fig. A) 10 (All around) (Suspention bolt position) Dews may drop when humidity reaches 2) One inspection hatch (450 × 450) on the control box 8 9 over 80%, or a drain gets stuck, or air side and 2 (two) inspection hatches under the unit. filters are not clean. (Arrow View B-1) 3) 3 (three) inspection hatches under the unit and the FXMQ20P / 25P / 32PVE 10-8 × 12 oblong hole control box. (Arrow View B-2) 3. Dimensions (All around) CASE 1) Inspection hatch 1 355 Air Air inlet 210 (450mm × 450mm) Control box 550 outlet 4 × 65=260 Control box 6 × 65=390 200 or less 300 or more 245 215 150 588 (Suspention bolt position) Inspection hatch Ceiling Unit base 22-φ 4.7 hole Air Air 60 200 59 2 × 150=300 49 or less outlet inlet 165 (All around) Fig. A 310 Inspection hatch 1 CASE 2), 3) (450mm × 450mm) 450 or more 335 Control box (Service space) Control box Inspection hatch 3 View (SAME AS THE INDOOR 20 UNIT SIZE +300 OR MORE) 700 or more (From the Air outlet) 200 or more Control box or less (Service space) Inspection hatch 450 or more B 850 Ceiling 550 or more or more Inspection hatch 167 700 700 Inspection hatch 2 or more or more 12 (SAME AS THE INDOOR View B-1 View B-2 UNIT SIZE OR MORE) 3 1 2 5 Air inlet 300 or less 288 Adjustable 6 (467 or less) (Note. 2) 12 Drain hose (Accessory) O. D. φ 32 (Outlet) Air outlet Socket (For maintenance) 700 or less 11 VP25 (O. D. φ 32, I. D. φ 25) 10 Hook For M10 9 Air suction flange 277 247 150 300 232 212 8 Air discharge flange 150 144 80Please purchase PDF Split-Merge on www.verypdf.com to remove this watermark. 7 Power supply connection 169 12-8 × 12 oblong hole 40 11 3 × 150=450 6 Interunit wiring connection 7 4 (All around) 290 28 5 Control box (Inside) 700 475 4 Ground terminal (Terminal in Control box) M4 (Note. 4) 3 × 65=195 2 × 65=130 300 or more 500 3 Drain pipe connection VP25 (O. D. φ 32, I. D. φ 25) 2500 or more (A case without the ceiling) 2 Gas pipe connection φ 12.7 flale connection Ceiling (From the Air inlet) 1 Liquid pipe connection φ 6.4 flale connection Floor surface ITEM PART NAME REMARK 3D062541A Unit (mm) ED34-862 FXMQ-P
  • Notes) 1. Location of MANUFACTURES LABEL: 4. Space for Service Works FXMQ-P ED34-862 Control box surface According to any one of below 1)~3), secure a space 2. Mount the air filter at the suction side. for service works, such as, checking and maintenance Select its colorimethod (gravity method) of control box and drain pumps, etc. FXMQ40PVE 27 631 10 50% or more. 1) One inspection hatch (450 × 450) on the control box 20-φ 4.7 hole (Suspention bolt position) 3. Do not locate things should not be wet side and a space of 300mm or more under the unit. 8 (All around) 9 under the indoor unit. (Fig. A) Dews may drop when humidity reaches 2) One inspection hatch (450 × 450) on the control box over 80%, or a drain gets stuck, or air side and 2 (two) inspection hatches under the unit. filters are not clean. (Arrow View B-1) 3) 3 (three) inspection hatches under the unit and the 12-8 × 12 oblong hole control box. (Arrow View B-2) 505 (All around) Inspection hatch 1 CASE 1) 700 6 × 65=390 Air Air inlet 285 (450mm × 450mm) 8 × 65=520 Control box Control box outlet 200 or less 300 or more 738 (Suspention bolt position) 245 215 150 Inspection hatch Ceiling Unit base 26-φ 4.7 hole Air Air 59 60 200 3 × 150=450 49 or less outlet 165 (All around) inlet Fig. A 460 Inspection hatch 1 CASE 2), 3) (450mm × 450mm) 450 or more 485 Control box (Service space) Control box Inspection hatch 3 View (SAME AS THE INDOOR 20 (From the Air outlet) UNIT SIZE +300 OR MORE) 700 or more or more 200 Control box or less (Service space) Inspection hatch 450 or more B Ceiling 1000 700 or more or more Inspection hatch 167 700 700 Inspection hatch 2 or more or more 12 (SAME AS THE INDOOR View B-1 View B-2 UNIT SIZE OR MORE) 3 1 2 5 Air inlet 300 or less 363 Adjustable 6 12 Drain hose (Accessory) O. D. φ 32 (Outlet) (467 or less) (Note. 2) Air outlet 11 Socket (For maintenance) VP25 (O. D. φ 32, I. D. φ 25) 700 or less 10 Hook For M10 9 Air suction flange 277 247 150 300Please purchase PDF Split-Merge on www.verypdf.com to remove this watermark. 8 Air discharge flange 232 212 150 144 80 7 Power supply connection 169 14-8 × 12 oblong hole 6 Interunit wiring connection 40 11 7 4 (All around) 4 × 150=600 5 Control box (Inside) 290 28 4 Ground terminal (Terminal in Control box) M4 700 (Note. 4) 625 3 × 65=195 2 × 65=130 3 Drain pipe connection 300 or more VP25 (O. D. φ 32, I. D. φ 25) 2500 or more 650 2 Gas pipe connection φ 12.7 flale connection (A case without the ceiling) 1 Liquid pipe connection φ 6.4 flale connection Ceiling (From the Air inlet) Floor surface ITEM PART NAME REMARK 3D060160E Unit (mm) 249 Dimensions 7
  • 250 Notes) 1. Location of MANUFACTURES LABEL: 4. Space for Service Works Control box surface According to any one of below 1)~3), secure a space Dimensions 2. Mount the air filter at the suction side. for service works, such as, checking and maintenance Select its colorimethod (gravity method) of control box and drain pumps, etc. FXMQ50PVE 30-φ 4.7 hole 27 631 10 50% or more. 1) One inspection hatch (450 × 450) on the control box (All around) (Suspention bolt position) 3. Do not locate things should not be wet side and a space of 300mm or more under the unit. 36-φ 4.7 hole under the indoor unit. (Fig. A) (All around) 8 Dews may drop when humidity reaches 2) One inspection hatch (450 × 450) on the control box over 80%, or a drain gets stuck, or air side and 2 (two) inspection hatches under the unit. filters are not clean. (Arrow View B-1) 3) 3 (three) inspection hatches under the unit and the control box. (Arrow View B-2) Inspection hatch 1 CASE 1) (450mm × 450mm) 805 Control box Control box Air Air inlet 1000 200 11 × 65=715 or less outlet 300 13 × 65=845 or more 435 16-8 × 12 oblong hole (All around) Unit base Inspection hatch Ceiling 1038 (Suspention bolt position) 9 Air Air outlet Fig. A inlet 245 215 150 Inspection hatch 1 CASE 2), 3) (450mm × 450mm) 59 200 60 Control box Control box or less 5 × 150=750 49 Inspection hatch 3 165 (SAME AS THE INDOOR 760 20 UNIT SIZE +300 OR MORE) or more Control box 450 or more 200 or less (Service space) 785 B Ceiling 1300 View 1000 or more or more 700 or more Inspection hatch (From the Air outlet) 700 700 (Service space) Inspection hatch 450 or more Inspection hatch 2 or more or more 12 18-8 × 12 oblong hole (SAME AS THE INDOOR View B-1 View B-2 Air inlet (All around) UNIT SIZE OR MORE) 3 1 2 5 300 or less 513 167 6 12 Drain hose (Accessory) O. D. φ 32 (Outlet) (Note. 2) Air outlet 11 Socket (For maintenance) VP25 (O. D. φ 32, I. D. φ 25) Adjustable (467 or less) 10 Hook For M10 9 Air suction flange 700 or less 277 247 150 300Please purchase PDF Split-Merge on www.verypdf.com to remove this watermark. 8 Air discharge flange 232 212 150 144 80 7 Power supply connection 169 6 Interunit wiring connection 40 11 7 4 6 × 150=900 5 Control box (Inside) 290 28 4 Ground terminal (Terminal in Control box) M4 925 (Note. 4) 2 × 65=130 3 × 65=195 700 3 Drain pipe connection 300 or more VP25 (O. D. φ 32, I. D. φ 25) 2500 or more 950 2 Gas pipe connection φ 12.7 flale connection (A case without Ceiling the ceiling) (From the Air inlet) 1 Liquid pipe connection φ 6.4 flale connection Floor surface ITEM PART NAME REMARK 3D060159D Unit (mm) ED34-862 FXMQ-P View slide
  • Notes) 1. Location of MANUFACTURES LABEL: 4. Space for Service Works Control box surface According to any one of below 1)~3), secure a space FXMQ-P 2. Mount the air filter at the suction side. for service works, such as, checking and maintenance ED34-862 Select its colorimethod (gravity method) of control box and drain pumps, etc. 30-φ 4.7 hole 27 631 10 50% or more. 1) One inspection hatch (450 × 450) on the control box (Suspention bolt position) 3. Do not locate things should not be wet side and a space of 300mm or more under the unit. (All around) 36-φ 4.7 hole under the indoor unit. (Fig. A) (All around) Dews may drop when humidity reaches 2) One inspection hatch (450 × 450) on the control box FXMQ63P / 80PVE 8 over 80%, or a drain gets stuck, or air side and 2 (two) inspection hatches under the unit. filters are not clean. (Arrow View B-1) 3) 3 (three) inspection hatches under the unit and the control box. (Arrow View B-2) CASE 1) Inspection hatch 1 (450mm × 450mm) 805 Control box Control box Air Air inlet 1000 200 11 × 65=715 or less outlet 300 13 × 65=845 or more 435 16-8 × 12 oblong hole (All around) Inspection hatch Ceiling Unit base 1038 (Suspention bolt position) 9 Air Air outlet Fig. A inlet 245 215 150 Inspection hatch 1 CASE 2), 3) (450mm × 450mm) 200 59 Control box 65 Control box or less 5 × 150=750 49 Inspection hatch 3 165 (SAME AS THE INDOOR 760 20 UNIT SIZE +300 OR MORE) or more 200 Control box 450 or more or less (Service space) 785 B Ceiling 1300 View 1000 or more or more 700 or more Inspection hatch (Service space) (From the Air outlet) 700 700 Inspection hatch 2 or more or more Inspection hatch 450 or more 12 18-8 × 12 oblong hole (SAME AS THE INDOOR (All around) UNIT SIZE OR MORE) View B-1 View B-2 167 3 1 2 5 Air inlet 300 or less 513 6 (Note. 2) Air outlet 12 Drain hose (Accessory) O. D. φ 32 (Outlet) Adjustable (467 or less) 11 Socket (For maintenance) VP25 (O. D. φ 32, I. D. φ 25) 10 Hook For M10 700 or less 277 247 150 300 9 Air suction flange 232 212 150 144 8 Air discharge flange 80Please purchase PDF Split-Merge on www.verypdf.com to remove this watermark. 7 Power supply connection 169 40 11 7 4 6 × 150=900 6 Interunit wiring connection 290 28 5 Control box (Inside) 925 (Note. 4) 3 × 65=195 2 × 65=130 700 4 Ground terminal (Terminal in Control box) M4 300 or more 950 3 Drain pipe connection 2500 or more VP25 (O. D. φ 32, I. D. φ 25) (A case without the ceiling) 2 Gas pipe connection φ 15.9 flale connection Ceiling (From the Air inlet) Floor surface 1 Liquid pipe connection φ 9.5 flale connection ITEM PART NAME REMARK 3D060161E Unit (mm) 251 Dimensions 7 View slide
  • 252 Notes) 1. Location of MANUFACTURES LABEL: 4. Space for Service Works Control box surface According to any one of below 1)~3), secure a space 2. Mount the air filter at the suction side. for service works, such as, checking and maintenance 27 631 Select its colorimethod (gravity method) of control box and drain pumps, etc. 40-φ 4.7 hole 10 Dimensions (Suspention bolt position) 50% or more. 1) One inspection hatch (450 × 450) on the control box (All around) 48-φ 4.7 hole 3. Do not locate things should not be wet side and a space of 300mm or more under the unit. (All around) under the indoor unit. (Fig. A) 8 Dews may drop when humidity reaches 2) One inspection hatch (450 × 450) on the control box over 80%, or a drain gets stuck, or air side and 2 (two) inspection hatches under the unit. filters are not clean. (Arrow View B-1) FXMQ100P / 125PVE 3) 3 (three) inspection hatches under the unit and the control box. (Arrow View B-2) Inspection hatch 1 CASE 1) (450mm × 450mm) Control box Control box 1205 200 1400 or less 300 16 × 65=1040 or more 19 × 65=1235 Air Air inlet outlet Inspection hatch Ceiling Unit base Air Air 1438 (Suspention bolt position) (SAME AS THE INDOOR outlet inlet UNIT SIZE OR MORE) Fig. A 9 635 20-8 × 12 oblong hole Inspection hatch 1 (All around) CASE 2), 3) (450mm × 450mm) Control box Control box Inspection hatch 3 245 215 150 (SAME AS THE INDOOR 200 59 65 20 or less UNIT SIZE +300 OR MORE) 200 or more Control box or less 7 × 150=1050 49 165 450 or more 1160 B Ceiling (Service space) 1700 1400 or more or more Inspection hatch 1185 700 700 700 or more Inspection hatch 2 or more or more (Service space) View (SAME AS THE INDOOR Inspection hatch 450 or more View B-1 View B-2 12 UNIT SIZE OR MORE) (From the Air outlet) 3 20-8 × 12 oblong hole 12 Drain hose (Accessory) 167 1 2 5 Air inlet 300 or less 713 O. D. φ 32 (Outlet) 6 (Note.2) (All around) 11 Socket (For maintenance) VP25 (O. D. φ 32, I. D. φ 25) Air outlet Adjustable (467 or less) 10 Hook For M10 9 Air suction flange 277 247 150 700 or more 300 8 Air discharge flange 232Please purchase PDF Split-Merge on www.verypdf.com to remove this watermark. 212 150 144 80 7 Power supply connection 169 6 Interunit wiring connection 40 11 7 4 8 × 150=1200 290 28 5 Control box (Inside) 1325 4 Ground terminal (Terminal in Control box) M4 (Note. 4) 700 3 × 65=195 2 × 65=130 300 or more 3 Drain pipe connection VP25 (O. D. φ 32, I. D. φ 25) 1350 2500 or more (A case without the ceiling) 2 Gas pipe connection φ 15.9 flale connection Ceiling (From the Air inlet) Floor surface 1 Liquid pipe connection φ 9.5 flale connection ITEM PART NAME REMARK 3D060162D Unit (mm) ED34-862 FXMQ-P