248                                                                                                                       ...
Notes) 1. Location of MANUFACTURES LABEL:                      4. Space for Service Works        FXMQ-P                   ...
Thong so ky thuat dan lanh fxmq + lo mo tran
Thong so ky thuat dan lanh fxmq + lo mo tran
Thong so ky thuat dan lanh fxmq + lo mo tran
Upcoming SlideShare
Loading in …5
×

Thong so ky thuat dan lanh fxmq + lo mo tran

803 views
711 views

Published on

Published in: Business, Technology
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
803
On SlideShare
0
From Embeds
0
Number of Embeds
2
Actions
Shares
0
Downloads
13
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Thong so ky thuat dan lanh fxmq + lo mo tran

  1. 1. 248 Notes) 1. Location of MANUFACTURES LABEL: 4. Space for Service Works Control box surface According to any one of below 1)~3), secure a space 2. Mount the air filter at the suction side. for service works, such as, checking and maintenance Select its colorimethod (gravity method) of control box and drain pumps, etc. Dimensions 50% or more. 1) One inspection hatch (450 × 450) on the control box 3. Do not locate things should not be wet side and a space of 300mm or more under the unit. 16-φ 4.7 hole 27 631 under the indoor unit. (Fig. A) 10 (All around) (Suspention bolt position) Dews may drop when humidity reaches 2) One inspection hatch (450 × 450) on the control box 8 9 over 80%, or a drain gets stuck, or air side and 2 (two) inspection hatches under the unit. filters are not clean. (Arrow View B-1) 3) 3 (three) inspection hatches under the unit and the FXMQ20P / 25P / 32PVE 10-8 × 12 oblong hole control box. (Arrow View B-2) 3. Dimensions (All around) CASE 1) Inspection hatch 1 355 Air Air inlet 210 (450mm × 450mm) Control box 550 outlet 4 × 65=260 Control box 6 × 65=390 200 or less 300 or more 245 215 150 588 (Suspention bolt position) Inspection hatch Ceiling Unit base 22-φ 4.7 hole Air Air 60 200 59 2 × 150=300 49 or less outlet inlet 165 (All around) Fig. A 310 Inspection hatch 1 CASE 2), 3) (450mm × 450mm) 450 or more 335 Control box (Service space) Control box Inspection hatch 3 View (SAME AS THE INDOOR 20 UNIT SIZE +300 OR MORE) 700 or more (From the Air outlet) 200 or more Control box or less (Service space) Inspection hatch 450 or more B 850 Ceiling 550 or more or more Inspection hatch 167 700 700 Inspection hatch 2 or more or more 12 (SAME AS THE INDOOR View B-1 View B-2 UNIT SIZE OR MORE) 3 1 2 5 Air inlet 300 or less 288 Adjustable 6 (467 or less) (Note. 2) 12 Drain hose (Accessory) O. D. φ 32 (Outlet) Air outlet Socket (For maintenance) 700 or less 11 VP25 (O. D. φ 32, I. D. φ 25) 10 Hook For M10 9 Air suction flange 277 247 150 300 232 212 8 Air discharge flange 150 144 80Please purchase PDF Split-Merge on www.verypdf.com to remove this watermark. 7 Power supply connection 169 12-8 × 12 oblong hole 40 11 3 × 150=450 6 Interunit wiring connection 7 4 (All around) 290 28 5 Control box (Inside) 700 475 4 Ground terminal (Terminal in Control box) M4 (Note. 4) 3 × 65=195 2 × 65=130 300 or more 500 3 Drain pipe connection VP25 (O. D. φ 32, I. D. φ 25) 2500 or more (A case without the ceiling) 2 Gas pipe connection φ 12.7 flale connection Ceiling (From the Air inlet) 1 Liquid pipe connection φ 6.4 flale connection Floor surface ITEM PART NAME REMARK 3D062541A Unit (mm) ED34-862 FXMQ-P
  2. 2. Notes) 1. Location of MANUFACTURES LABEL: 4. Space for Service Works FXMQ-P ED34-862 Control box surface According to any one of below 1)~3), secure a space 2. Mount the air filter at the suction side. for service works, such as, checking and maintenance Select its colorimethod (gravity method) of control box and drain pumps, etc. FXMQ40PVE 27 631 10 50% or more. 1) One inspection hatch (450 × 450) on the control box 20-φ 4.7 hole (Suspention bolt position) 3. Do not locate things should not be wet side and a space of 300mm or more under the unit. 8 (All around) 9 under the indoor unit. (Fig. A) Dews may drop when humidity reaches 2) One inspection hatch (450 × 450) on the control box over 80%, or a drain gets stuck, or air side and 2 (two) inspection hatches under the unit. filters are not clean. (Arrow View B-1) 3) 3 (three) inspection hatches under the unit and the 12-8 × 12 oblong hole control box. (Arrow View B-2) 505 (All around) Inspection hatch 1 CASE 1) 700 6 × 65=390 Air Air inlet 285 (450mm × 450mm) 8 × 65=520 Control box Control box outlet 200 or less 300 or more 738 (Suspention bolt position) 245 215 150 Inspection hatch Ceiling Unit base 26-φ 4.7 hole Air Air 59 60 200 3 × 150=450 49 or less outlet 165 (All around) inlet Fig. A 460 Inspection hatch 1 CASE 2), 3) (450mm × 450mm) 450 or more 485 Control box (Service space) Control box Inspection hatch 3 View (SAME AS THE INDOOR 20 (From the Air outlet) UNIT SIZE +300 OR MORE) 700 or more or more 200 Control box or less (Service space) Inspection hatch 450 or more B Ceiling 1000 700 or more or more Inspection hatch 167 700 700 Inspection hatch 2 or more or more 12 (SAME AS THE INDOOR View B-1 View B-2 UNIT SIZE OR MORE) 3 1 2 5 Air inlet 300 or less 363 Adjustable 6 12 Drain hose (Accessory) O. D. φ 32 (Outlet) (467 or less) (Note. 2) Air outlet 11 Socket (For maintenance) VP25 (O. D. φ 32, I. D. φ 25) 700 or less 10 Hook For M10 9 Air suction flange 277 247 150 300Please purchase PDF Split-Merge on www.verypdf.com to remove this watermark. 8 Air discharge flange 232 212 150 144 80 7 Power supply connection 169 14-8 × 12 oblong hole 6 Interunit wiring connection 40 11 7 4 (All around) 4 × 150=600 5 Control box (Inside) 290 28 4 Ground terminal (Terminal in Control box) M4 700 (Note. 4) 625 3 × 65=195 2 × 65=130 3 Drain pipe connection 300 or more VP25 (O. D. φ 32, I. D. φ 25) 2500 or more 650 2 Gas pipe connection φ 12.7 flale connection (A case without the ceiling) 1 Liquid pipe connection φ 6.4 flale connection Ceiling (From the Air inlet) Floor surface ITEM PART NAME REMARK 3D060160E Unit (mm) 249 Dimensions 7

×