T H EC A B L EA N DA C C E S S O R YC A T A L O G U EA W O R L D P O W E R I N C A B L E S U P P L Y
CLEVELANDCABLELOCATIONS 2CLEVELAND CABLE LOCATIONS
3CLEVELANDCABLECOMPANYAs is illustrated within our catalogue, we stock acomprehensive range of cables for everyconceivable...
4CLEVELANDCABLECOMPANYCLEVELAND CABLE COMPANYCleveland Cable Company, established in 1978, isundoubtedly the foremost dist...
6GLAND SELECTION GUIDELINESThere are many factors to considered when selectingcable glands for industrial installations. N...
7CONTENTSSECTION 1 Low Voltage PVC Fixed Wiring & Mains Cables6491X (HO7V-R) PVC insulated wiring, 1.5mm2– 630mm2............
8SECTION 4 Medium Voltage 11000V & aboveBS6622 Mains, single core, XLPE, CTS, PVC, aluminium wire armoured, PVC, 11000V, 5...
9SECTION 7 Flexible Cables, RubberBS6500 EPR insulated, CSP sheathed, flexible power & control, 0.75 – 2.5mm2................
10CONTENTSPetroleum jelly filled telephone cable to CW1128, CW1128/1198 and BS3573...........................................
11FIXED WIRING ANDMAINS CABLESPVCFIXEDWIRINGANDMAINSCABLESPVC
FIXEDWIRINGANDMAINSCABLESPVC 12Please note that gland and cleat sizes are intended to be indicative and may vary according...
FIXEDWIRINGANDMAINSCABLESPVC13Please note that gland and cleat sizes are intended to be indicative and may vary according ...
FIXEDWIRINGANDMAINSCABLESPVC 14Please note that gland and cleat sizes are intended to be indicative and may vary according...
MAINS CABLES PVCStranded plain annealed copper conductors, XLPE insulated, PVC bedding,galvanised steel wire armour, PVC o...
FIXEDWIRINGANDMAINSCABLESPVCPlease note that gland and cleat sizes are intended to be indicative and may vary according to...
FIXEDWIRINGANDMAINSCABLESPVC17Please note that gland and cleat sizes are intended to be indicative and may vary according ...
18FIXEDWIRINGANDMAINSCABLESPVCPlease note that gland and cleat sizes are intended to be indicative and may vary according ...
19FIXEDWIRINGANDMAINSCABLESPVCPlease note that gland and cleat sizes are intended to be indicative and may vary according ...
20FIXEDWIRINGANDMAINSCABLESPVCPlease note that gland and cleat sizes are intended to be indicative and may vary according ...
21FIXEDWIRINGANDMAINSCABLESPVCEEMUA133 MAINS CABLES PVCPlain annealed stranded copper conductors, XLPE insulated, lead she...
22FIXEDWIRINGANDMAINSCABLESPVCPlease note that gland and cleat sizes are intended to be indicative and may vary according ...
23FIXEDWIRINGANDMAINSCABLESPVCPlease note that gland and cleat sizes are intended to be indicative and may vary according ...
24FIXEDWIRINGANDMAINSCABLESPVCSPLIT CONCENTRIC CABLES PVCPlain annealed stranded copper phase conductor, XLPE insulated su...
25FIXED WIRING ANDMAINS CABLES3300V PVCFIXEDWIRINGANDMAINSCABLESPVC
26SINGLE CORE ARMOURED MAINS CABLES 1900/3300VStranded plain annealed copper conductors, XLPE insulated, PVC bedding,galva...
27XLPE INSULATEDMAINS CABLE3300 VOLT(16MM2 TO 400MM2)Please note that gland and cleat sizes are intended to be indicative ...
28FIXEDWIRINGANDMAINSCABLESPVCMAINS CABLES FOR MINES & QUARRIES 1900/3300VPlain annealed stranded copper conductors, XLPE ...
29Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers t...
31FIXED WIRING ANDMAINS CABLESLSZHFIXEDWIRINGANDMAINSCABLESLSZH
32FIXEDWIRINGANDMAINSCABLESLSZHPlease note that gland and cleat sizes are intended to be indicative and may vary according...
33SURFACE WIRING CABLES LSZH 624*BPlain annealed compacted copper conductor, XLPE insulated, one, two or threecores laid f...
FIXEDWIRINGANDMAINSCABLESLSZH 34Please note that gland and cleat sizes are intended to be indicative and may vary accordin...
MAINS CABLES LSZHStranded plain annealed copper conductors, XLPE insulated, low smoke andzero halogen (LSZH) extruded bedd...
FIXEDWIRINGANDMAINSCABLESLSZH 36Please note that gland and cleat sizes are intended to be indicative and may vary accordin...
37SINGLE CORE ARMOURED MAINS CABLE LSZHStranded plain annealed compacted circular copper conductor, XLPE insulated,low smo...
38SCREENEDFIXEDWIRINGANDMAINSCABLESTOBS8436Plain annealed stranded copper, XLPE insulated, tinned annealed strandedcopper ...
39FIXED WIRING ANDMAINS CABLES11000VFIXEDWIRINGANDMAINSCABLES
403 CORE MAINS CABLES PVC 11000VStranded plain annealed circular compacted copper conductors, XLPE insulated,semi-conducti...
FIXEDWIRINGANDMAINSCABLES41Please note that gland and cleat sizes are intended to be indicative and may vary according to ...
FIXEDWIRINGANDMAINSCABLESPlease note that gland and cleat sizes are intended to be indicative and may vary according to di...
FIXEDWIRINGANDMAINSCABLES43Please note that gland and cleat sizes are intended to be indicative and may vary according to ...
FIXEDWIRINGANDMAINSCABLESPlease note that gland and cleat sizes are intended to be indicative and may vary according to di...
45FIREPROOF CABLESFIREPROOFCABLES
46FIREPROOF CABLES - MINERAL INSULATEDSolid plain annealed copper conductors, magnesium oxide insulated, solid coppersheat...
47FIREPROOFCABLESPlease note that gland and cleat sizes are intended to be indicative and may vary according to different ...
48FIREPROOF MAINS AND CONTROL CABLES LSZHPlain annealed stranded copper conductor, mica fire resistant tape, XLPEinsulated...
49Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers t...
51FLEXIBLE CABLESFLEXIBLECABLES
FLEXIBLECABLES 52Please note that gland and cleat sizes are intended to be indicative and may vary according to different ...
FLEXIBLECABLES53Please note that gland and cleat sizes are intended to be indicative and may vary according to different m...
FLEXIBLECABLES 54Please note that gland and cleat sizes are intended to be indicative and may vary according to different ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, ...
Upcoming SlideShare
Loading in …5
×

Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, Alarms & Security Cables, LSZH Fixed Cables, Low Voltage PVC Fixed Wiring & Mains Cables

1,250 views
1,115 views

Published on

Cleveland Cables are leading UK distributors of LV HV power cables, 3.3kV, 6.6kV, 11kV and 33kV.

Cleveland Cable Cables - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, Alarms & Security Cables, Low Smoke Zero Halogen Fixed Cables, Low Voltage PVC Fixed Wiring & Mains Cables

Published in: Technology
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
1,250
On SlideShare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
18
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Cleveland Cable - Marine & Offshore, Railway, Instrumentation, Control & Communication, Flexible Cables, Fire Protection, Alarms & Security Cables, LSZH Fixed Cables, Low Voltage PVC Fixed Wiring & Mains Cables

  1. 1. T H EC A B L EA N DA C C E S S O R YC A T A L O G U EA W O R L D P O W E R I N C A B L E S U P P L Y
  2. 2. CLEVELANDCABLELOCATIONS 2CLEVELAND CABLE LOCATIONS
  3. 3. 3CLEVELANDCABLECOMPANYAs is illustrated within our catalogue, we stock acomprehensive range of cables for everyconceivable application. All types shown areconsidered as standard items to our range and arealways available for immediate delivery. Our stocksare extremely large and unrivalled in the industry.We are fortunate to have a veryexperienced and dedicated team ofpeople who are able to assist andadvise. Additionally our policy ofcontinuing investment in the bestavailable technology, warehousing,handling and measuring equipmentand delivery vehicles enables us toguarantee all our customers anextremely high quality service.Enquiries are welcome from customers worldwide. Our export service is efficientand reliable with the ability to ship by air or sea freight to any destination.Please feel free to contact the depot of yourchoice for an immediate, professional andtrouble free service.Middlesbrough 01642 241133Bristol 01179 382222Glasgow 0141 6465000Milton Keynes 01908 221414London 0208 3114141Newcastle 0191 2633363Warrington 01925 655383
  4. 4. 4CLEVELANDCABLECOMPANYCLEVELAND CABLE COMPANYCleveland Cable Company, established in 1978, isundoubtedly the foremost distributor of electricalcables in Great Britain and possibly Europe.The Head Office and principal stocking location is located at Middlesbrough in theNorth East of England. This site covers an area of twelve acres and includes over160,000 square feet of warehousing. Additionally there are regional depots atBristol, Glasgow, London, Milton Keynes, Newcastle and Warrington. Each locationholds comprehensive stocks and is equipped with the most modern handling andmeasuring equipment. Deliveries are made by our own fleet of purpose-designedvehicles, all of which are fitted with hydraulic lifting equipment for safe offloadingonsite and also efficient collection of empty drums.
  5. 5. 6GLAND SELECTION GUIDELINESThere are many factors to considered when selectingcable glands for industrial installations. Neglecting togive due attention to these factors could causeunnecessary difficulties at a crucial point in time wheremost inconvenience and expense can result. It is mostdesirable to avoid discovering that, once all otherequipment is on site or installed, the glands have notbeen ordered or are the wrong size or type.Good practise would be to allocate some planning andpreparation time to cable gland selection. This will helpavoid the possible disruption which could result at acritical point of the installation process. In the event of aproject schedule of cables being available ClevelandCable Company are happy to offer a gland selection andsizing service. Please contact any of our depots forfurther information or assistance.Here is a summary of some aspects to carefully considerwhen selecting cable glands.• Identify the type of cable to be used.• Check the construction, size and material propertiesof the cable.• Check the type and material of the cable armour(*)• Check the short circuit fault current rating of thecable armour(**)• Check the actual diameter of the inner bedding(where present) against this catalogue.• Check the actual diameter of the lead covering (wherepresent) against this catalogue.• Check the actual size of the overall cable diameteragainst this catalogue.• Check the size and type or armour or braid (wherepresent) against this catalogue.• Check any special environmental requirements inrelation to corrosion protection• Check the material of the mating electrical enclosuresto eliminate dis-similar metals.• Consider whether any protective plating is required tobe applied to the cable gland.• Check the type and size of the cable entry hole in themating electrical equipment.• Check the ingress protection rating of the electricalequipment or site standard.• Check whether a single or double seal cable gland isrequired.• Check whether an entry thread seal is required forIP66 (or IP67/IP68) conditions.• Check whether fixing accessories such as locknutsand serrated washers are required.• Check whether earth tags are required. (**)• Check whether shrouds are required.• Select a corresponding cable gland type from thiscatalogue.• For installations in Hazardous Areas, specialconsiderations should be taken into account to ensurecompliance with national or international codes ofpractice.• Check whether a thread conversation adaptor orreducer is required to make the installation.• Select corresponding adaptors or reducers from thiscatalogue.• Check whether any stopper plugs are required to closeunused cable entries.• Select corresponding stopper plugs from thiscatalogue.Note (*): If the cable armour is of a non standardmaterial, i.e. Aluminium Wire Armour, it may benecessary to consider an alternative cable gland material,e.g. Aluminium.Note (**): For certain medium voltage and high voltagecables where the fault current carrying capacity of thecable armour is greater that that of the standard earthtag it may be necessary to consider a cable gland utilisingthe a heavy Cast Integral Earth Lug (CIEL) option whichcan be identified in the body of this catalogue.
  6. 6. 7CONTENTSSECTION 1 Low Voltage PVC Fixed Wiring & Mains Cables6491X (HO7V-R) PVC insulated wiring, 1.5mm2– 630mm2........................................................................................................................12Bare copper strand, soft drawn to BS6360/81, 6mm2 - 400mm2............................................................................................................126181Y PVC insulated, PVC sheathed surface wiring, 1.5mm2– 120mm2..............................................................................................13624*Y PVC insulated, PVC sheathed surface wiring, 1mm2– 16mm2....................................................................................................13BS5467 Mains & control, XLPE, PVC SWA, PVC, 1.5mm2– 16mm2including multicores................................................................14BS5467 Mains, XLPE, PVC, SWA, PVC, copper conductors, 25mm2– 400mm2....................................................................................15BS5467 Mains, XLPE, PVC, SWA, PVC, aluminium conductors, 25mm2– 300mm2............................................................................16BS7889 Mains, single core, XLPE, PVC, non-armoured, 6mm2– 1000mm2..........................................................................................17BS5467 Mains, single core, XLPE, PVC, aluminium wire armoured, PVC, 50mm2–1000mm2......................................................18Mines & Quarries Mains, XLPE, PVC, SWA, PVC, with 60% Conductivity in armour, 10mm2– 300mm2................................19EEMUA 133 Multicore, XLPE, lead sheathed, PVC, SWA, PVC, Control cable for petro-chemical industries, 1.5mm2– 4mm2......20EEMUA 133 Mains, XLPE, lead sheathed, PVC,SWA, PVC, for petro-chemical industries, 1.5mm2– 16mm2..........................21EEMUA 133 Mains, XLPE, lead sheathed, PVC, SWA, PVC, for petro-chemical industries, 25mm2– 300mm2......................22Cathodic Protection Cables. XLPE, PVC, and XLPE, PVC, SWA, PVC, 6mm2– 185mm2......................................................................23Concentric, split & straight, single phase service cable, 4mm2– 35mm2............................................................................................24SECTION 2 3300V Mains CableBS5467 Mains, single core XLPE, PVC, aluminium wire armoured, PVC, 3300V, 120mm2– 630mm2......................................26BS5467 Mains three core, XLPE, PVC, SWA, PVC, 3300V, 16mm2– 300mm2........................................................................................27Mines & Quarries Mains, XLPE, PVC, SWA, PVC, with 60% conductivity in armour, 3300V, 16mm2– 300mm2..................28EEMUA 133 Mains, XLPE, Lead sheathed, PVC, SWA, PVC, for petro-chemical industries, 3300V, 25mm2– 300mm2......29SECTION 3 LSZH Fixed Wiring & Mains Cables6491B (H07Z-R) LSZH insulated wiring, 1.5mm2– 630mm2......................................................................................................................326181B XLPE insulated, LSZH sheathed, surface wiring, 1.5mm2– 120mm2........................................................................................33624*B LSZH insulated, LSZH sheathed surface wiring 1.5mm2– 16mm2..............................................................................................33BS6724 Mains & control, XLPE, LSZH, SWA, LSZH, 1.5mm2– 16mm2including multicores..........................................................34BS6724 Mains, XLPE, LSZH, SWA, LSZH, 25mm2– 400mm2........................................................................................................................35BS6724 Mains, single core, XLPE, LSZH, 50mm2– 1000mm2......................................................................................................................36BS6724 Mains, single core, XLPE, LSZH, aluminium wire armoured, LSZH, 50mm2– 1000mm2................................................37BS8436 Protected fixed wiring cable, 1mm2– 6mm2....................................................................................................................................38
  7. 7. 8SECTION 4 Medium Voltage 11000V & aboveBS6622 Mains, single core, XLPE, CTS, PVC, aluminium wire armoured, PVC, 11000V, 50mm2– 630mm2............................40BS6622 Mains, three core, XLPE, CTS, PVC, SWA, PVC, 11000V, 25mm2– 400mm2..........................................................................40BS6622 Mains, three core, aluminium conductor, XLPE, CTS, PVC, SWA, PVC, 11000V, 95mm2– 300mm2............................41Triplex, BS7870, aluminium conductor XLPE, CTS, MDPE, 11000V, utility cable, 70mm2– 300mm2........................................42Paper insulated, BS6480 Mains, three core, SWA, PVC, 11000V, 25mm2– 400mm2........................................................................43BS7835 Mains, single core, XLPE, CTS, LSZH, aluminium wire armoured, LSZH, 11000V, 50mm2– 630mm2........................44BS7835 Mains, three core, XLPE, CTS, LSZH, SWA, LSZH, 11000V, 35mm2– 400mm2......................................................................44SECTION 5 Fire Protection, Alarm & Security CablesMineral Insulated............................................................................................................................................................................................................46BS5839/BS7629 Fire performance alarm and security cable, 1mm2– 4mm2....................................................................................47BS6387/BS7846Mainsandcontrol,micatape,XLPE,LSZH,SWA,LSZH,fireresistant,1.5mm2–16mm2,includingmulticores................48BS6387/BS7846 Mains, mica tape, XLPE, LSZH, SWA, LSZH, fire resistant, 25mm2– 400mm2....................................................49SECTION 6 Flexible Cables, PVC218*Y ( H03VV-F) PVC, PVC, 0.5mm2– 0.75mm2..............................................................................................................................................52318*Y (H05VV-F) PVC, PVC, 0.5mm2– 2.5mm2................................................................................................................................................52309*Y Heat resisting PVC, PVC, 0.5mm2– 2.5mm2........................................................................................................................................53Artic grade low temperature flex, 1.5mm2– 4mm2........................................................................................................................................53318*B (H05ZIZI-F) LSZH, LSZH, 0.75mm2– 2.5mm2........................................................................................................................................54YY Control cable, 0.75mm2– 1.5mm2....................................................................................................................................................................55YY Control cable, 2.5mm2– 50mm2........................................................................................................................................................................56SY Control cable, 0.75mm2– 2.5mm2....................................................................................................................................................................57SY Control cable, 4.0mm2– 95mm2........................................................................................................................................................................58CY Control cable, 0.5mm2– 16mm2........................................................................................................................................................................59YY Control cable, LSZH, 0.75mm2– 25mm2........................................................................................................................................................60CY Control cable, LSZH, 0.75mm2– 1.5mm2......................................................................................................................................................60Tri-rated and Bi-rated BS6195, switchgear and control panel wire, 0.5mm2– 400mm2................................................................616381Y PVC, PVC, 6mm2– 400mm2..........................................................................................................................................................................62CONTENTS
  8. 8. 9SECTION 7 Flexible Cables, RubberBS6500 EPR insulated, CSP sheathed, flexible power & control, 0.75 – 2.5mm2................................................................................63BS7919 EPR insulated, CSP sheathed, flexible mains 4mm2......................................................................................................................64BS7919 EPR insulated, CSP sheathed, flexible mains, 6mm2– 630mm2..............................................................................................65HO7RN-F EPR insulated, PCP sheathed, flexible mains, 1.0mm2– 400mm2........................................................................................66380*P EPR insulated, copper braided screen, PCP sheathed, flexible mains, 1mm2– 16mm2......................................................67BS6500 EPR insulated, TR sheathed, flexible power & control 0.75mm2– 2.5mm2........................................................................67Coil lead BS6195 EPR, CSP, 0.5mm2– 400mm2..................................................................................................................................................68Welding cable, O361TQ EPR, CSP, 16mm2– 185mm2....................................................................................................................................69Flatform cable, PVC, PVC, 1.5mm2– 95mm2......................................................................................................................................................70Flatform cable, EPR, PCP, 1.5mm2– 70mm2........................................................................................................................................................70Silicon insulated, silicon sheathed, flexible cable, 0.75mm2– 2.5mm2..................................................................................................71SECTION 8 Instrumentation, Control & Communication CablesBS5308 Control and instrumentation cable, non-armoured with collective screen, 0.5mm2– 1.5mm2, part 1 and part 2 ......74BS5308 Control and instrumentation cable, non-armoured with individual and collective screen, 0.5mm2– 1.5mm2,part 1 and part 2 ............................................................................................................................................................................................................75BS5308 Control and instrumentation cable, armoured with collective screen, 0.5mm2– 2.5mm2, part 1 and part 2 ....76BS5308 Control and instrumentation cable, armoured with individual and collective screen, 0.5mm2– 1.5mm2,part 1 and part 2 ............................................................................................................................................................................................................77BS5308 Control and instrumentation cable, lead sheathed, armoured with collective screen, 0.75mm2– 1.5mm2,part 1 and part 2 ............................................................................................................................................................................................................78BS5308 Control and instrumentation cable, lead sheathed, armoured with individual and collective screen,0.75mm2– 1.5mm2, part 1 and part 2 ..................................................................................................................................................................79BS5308 part 1 core identification............................................................................................................................................................................80BS5308 part 2 core identification............................................................................................................................................................................81British Steel specification CES20 type 134, 0.75mm2....................................................................................................................................82British Steel specification CES20 type 143, 0.75mm2....................................................................................................................................83CW1308 telephone cable............................................................................................................................................................................................84Telephone cable to ESI 09-6 standard ............................................................................................................................................................85/86ESI 09-6 section 3.6 core identification ................................................................................................................................................................87ESI 09-6 section 4.5 core identification ................................................................................................................................................................88CONTENTS
  9. 9. 10CONTENTSPetroleum jelly filled telephone cable to CW1128, CW1128/1198 and BS3573................................................................................89Defence standard screened cable type 61-12....................................................................................................................................................90Defence standard 61-12 parts 4 & 5 core identification ..............................................................................................................................91Thermocouple extension and compensating cable, 0.75mm2..................................................................................................................92Thermocouple core identification............................................................................................................................................................................93Traffic signal cable, loop feeder cable and loop detector cable ..........................................................................................................94/95SECTION 9 Data CablesBelden equivalents ........................................................................................................................................................................................................98Coaxial cables ..................................................................................................................................................................................................................98Cat 5 data cables ............................................................................................................................................................................................................98SECTION 10 Railway CablesSignalling cable types A1, A2, A3, B1 and B2, 0.75mm2 – 95mm2........................................................................................................100Signalling cable types C1, C2, C3, D1, D2, D3, E1, E2 and E3, 0.75mm2 – 35mm2 ........................................................................101Train protection warning system cable..............................................................................................................................................................102Point heater cable ........................................................................................................................................................................................................102Axle counting cable ....................................................................................................................................................................................................103Datalink cable ................................................................................................................................................................................................................103Copper trackside cable ..............................................................................................................................................................................................104Power cables, 16mm2 – 95mm2 ..........................................................................................................................................................................105Trackfeeder cables, 150mm2 – 1000mm2........................................................................................................................................................105SECTION 11 Marine and Offshore CablesEPR insulated, non-armoured shipwiring cable, 1.5mm2 – 6mm2 ......................................................................................................108EPR insulated, non-armoured shipwiring cable, 10mm2 – 630mm2 ..................................................................................................109EPR insulated, braided armoured shipwiring cable, 1.5mm3 – 4mm2................................................................................................110EPR insulated, braided armoured shipwiring cable, 6mm3 – 300mm2 ..............................................................................................111EPR insulated, single core braided shipwiring cable, 6mm2 – 630mm2 ............................................................................................112SECTION 12 Installation Accessories ....................................................................................................................................................114SECTION 13 Current Ratings........................................................................................................................................................................127
  10. 10. 11FIXED WIRING ANDMAINS CABLESPVCFIXEDWIRINGANDMAINSCABLESPVC
  11. 11. FIXEDWIRINGANDMAINSCABLESPVC 12Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.PVC INSULATED WIRINGCABLE 6491X(1.5MM2 TO 630MM2)AND BARE COPPER STRAND(6MM2 TO 400MM2)6491X (HO7V-R) PVCStranded plain annealed compacted circular copper conductor, PVC outer sheath.Ref 6491X. Harmonised code HO7V-R. 450 volts grade to BS6004. Flamepropagation to BS4066 PT1 and IEC 60502-1.CCC CONDUCTOR STRANDING WEIGHT OVERALLCODE SIZE (MM2) (MM) KG/KM DIAMETER(MM)6491X1/5 1.5 7/0.53 21 3.006491X2/5 2.5 7/0.67 35 3.656491X4 4.0 7/0.85 50 4.206491X6 6.0 7/1.04 71 4.756491X10 10.0 7/1.35 120 6.156491X16 16.0 7/1.70 180 7.106491X25 25.0 7/2.14 280 8.906491X35 35.0 7/2.52 380 9.956491X50 50.0 19/1.78 510 11.706491X70 70.0 19/2.14 720 13.356491X95 95.0 19/2.52 990 15.606491X120 120.0 37/2.03 1200 17.206491X150 150.0 37/2.25 1500 19.106491X185 185.0 37/2.52 1900 21.306491X240 240.0 61/2.25 2500 24.306491X300 300.0 61/2.52 3000 27.056491X400 400.0 61/2.85 3950 30.356491X500 500.0 61/3.20 4950 32.806491X630 630.0 127/2.50 6250 36.50Temperature limits:-15 to +70°C.Bending radius:up to 10mm2- 3 x overall diameter.above 25mm2- 6 x overall diameter.Standard colours available:1.5mm2& 2.5mm2- Brown, Black,Grey, Blue, Green/Yellow, White,Orange, Turquoise, Violet, Pink.4mm2-630mm2- Brown, Black, Grey,Blue, Green/Yellow.Should not be installed attemperatures below 0°C orabove +60°C.Current ratings see page 128.BARE COPPER STRANDStranded plain annealed compacted circular copper conductor, non insulatedand non sheathed. 450 volts grade, soft drawn to BS6360/81.CCC CONDUCTOR STRANDING WEIGHT OVERALLCODE SIZE (MM2) (MM) KG/KM DIAMETER(MM)CB006 6.0 7/1.04 58 3.0CB010 10.0 7/1.35 96 4.2CB016 16.0 7/1.70 154 5.1CB025 25.0 7/2.14 240 5.9CB035 35.0 7/2.52 336 7.8CB050 50.0 19/1.78 480 8.8CB070 70.0 19/2.14 672 9.8CB095 95.0 19/2.52 912 12.5CB120 120.0 37/2.03 1152 12.8CB150 150.0 37/2.25 1440 14.4CB185 185.0 37/2.52 1776 16.1CB240 240.0 61/2.25 2304 19.8CB300 300.0 61/2.52 2800 20.6CB400 400.0 61/2.85 3750 26.4Temperature limits:- 15 to + 70°CBending radius:Up to 10mm - 3 x overall diameter.Above 25mm - 6 x overall diameter.Current ratings see page 128.
  12. 12. FIXEDWIRINGANDMAINSCABLESPVC13Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.SURFACE WIRING CABLES PVC 6181YPlain annealed stranded circular copper conductor, single core, PVC insulated,PVC sheathed, Ref 6181 Y. 300/500 volts grade to BS6004. Brown/Grey orBlue/Grey. Flame propagation to BS4066 PT1 and IEC 60502-1.CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLECODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT(MM) (MM)6181Y1 1.0 1/1.13 1 28 4.5 20/166181Y1/5 1.5 1/1.38 1 36 5.1 20/166181Y2/5 2.5 1/1.78 1 51 6.0 20/166181Y4 4.0 7/0.85 1 75 6.8 20/166181Y6 6.0 7/1.04 1 98 7.4 20/166181Y10 10.0 7/1.35 1 150 8.8 20S6181Y16 16.0 7/1.70 1 220 10.5 20S 0.56181Y25 25.0 7/2.14 1 340 12.5 20 0.56181Y35 35.0 7/2.52 1 440 13.5 25 0.66181Y50 50.0 19/1.78 1 540 14.38 25A2 0.66181Y70 70.0 19/2.14 1 750 15.3 25A2 0.76181Y95 95.0 19.2.52 1 1010 17.7 25A2 0.76181Y120 120.0 37/2.03 1 1250 19.3 32A2 0.8SURFACE WIRING CABLES PVC 624*YPlain annealed copper conductor, PVC insulated one, two or three coreslaid flat with an uninsulated circuit protective conductor and PVCsheathed. Grey. Ref 6241/2/3Y 300/500 V to BS6004. Flame propagationto BS4066 PT1 and IEC 60502-1Temperature limits:-15 to +70°C.Bending radius:up to 10mm2- 3 x overall diameter.over 10mm2- 4 x overall diameter.Should not be installed attemperatures below 0°C orabove +60°C.Temperature limits:-15 to +70°C.Bending radius:Fixed 3 x overall diameter.Should not be installed attemperatures below 0°C orabove +60°C.CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALLCODE SIZE (MM2) (MM) CORES KG/KM DIAMETER(MM) (MM)6241Y1BR 1.0 1/1.13 1 49 4.15 X 5.406241Y1/5BR 1.5 1/1.37 1 51 4.65 X 5.806242Y1 1.0 1/1.13 1 69 4.10 X 8.656242Y1/5 1.5 1/1.38 2 85 4.55 X 8.806242Y1/5BRBR 1.5 1/1.38 2 85 4.55 X 8.806242Y2/5 2.5 1/1.77 2 120 5.40 X 10.506242Y4 4.0 7/0.85 2 175 6.10 X 12.006242Y6 6.0 7/1.04 2 240 6.90 X 13.806242Y10 10.0 7/1.35 2 390 8.40 X 18.506242Y16 16.0 7.1.70 2 560 9.70 X 20.606243Y1 1.0 1/1.13 3 92 4.60 X 10.206243Y1/5 1.5 1/1.37 3 115 4.75 X 11.456243Y2/5 2.5 1/1.77 3 170 5.45 X 13.40PVC INSULATEDPVC SHEATHED SURFACEWIRING CABLETYPE 6181Y(1MM2 TO 120MM2)PVC INSULATEDPVC SHEATHEDWIRING CABLETYPE 624*Y(1MM2 TO 16MM2)
  13. 13. FIXEDWIRINGANDMAINSCABLESPVC 14Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.MAINS AND CONTROL CABLES PVCStranded plain annealed copper conductors, XLPE insulated, PVC bedding,galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade toBS5467. Flame propagation to IEC 60502-1 and BS4066 PT1.CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLECODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT(MM) (MM)XLPE2X1/5 1.5 7/0.53 2 295 12.00 20/16 0.5XLPE3X1/5 1.5 7/0.53 3 324 12.9 20/16 0.6XLPE4X1/5 1.5 7/0.53 4 367 13.7 20S 0.6XLPE5X1/5 1.5 7/0.53 5 380 14.2 20S 0.6XLPE7X1/5 1.5 7/0.53 7 463 15.6 20S 0.7XLPE8X1/5 1.5 7/0.53 8 501 16.7 20 0.7XLPE10X1/5 1.5 7/0.53 10 750 18.7 20 0.8XLPE12X1/5 1.5 7/0.53 12 791 20.1 20 0.8XLPE19X1/5 1.5 7/0.53 19 1030 23.2 25 1.0XLPE27X1/5 1.5 7/0.53 27 1420 27.7 32 1.1XLPE37X1/5 1.5 7/0.53 37 1750 30.3 32 1.2XLPE48X1/5 1.5 7/0.53 48 2100 32.3 32 1.4XLPE2X2/5 2.5 7/0.67 2 340 13.2 20S 0.6XLPE3X2/5* 2.5 7/0.67 3 392 13.8 20S 0.6XLPE4X2/5 2.5 7/0.67 4 440 14.7 20S 0.6XLPE5X2/5 2.5 7/0.67 5 480 16.1 20S 0.7XLPE7X2/5 2.5 7/0.67 7 584 17.1 20 0.7XLPE10X2/5 2.5 7/0.67 10 910 21.4 25 0.9XLPE12X2/5 2.5 7/0.67 12 950 22.0 25 0.9XLPE19X2/5 2.5 7/0.67 19 1500 26.5 25 1.1XLPE27X2/5 2.5 7/0.67 27 1928 30.7 32 1.4XLPE37X2/5 2.5 7/0.67 37 2300 33.8 32 1.4XLPE48X2/5 2.5 7/0.67 48 3010 39.0 40 1.6XLPE2X4 4.0 7/0.85 2 419 14.3 20S 0.6XLPE3X4* 4.0 7/0.85 3 460 14.9 20S 0.6XLPE4X4 4.0 7/0.85 4 550 16.2 20 0.7XLPE5X4 4.0 7/0.85 5 600 18.0 20 0.8XLPE7X4 4.0 7/0.85 7 700 19.7 20 0.8XLPE12X4 4.0 7/0.85 12 1300 25.0 25 1.0XLPE19X4 4.0 7/0.85 19 1750 28.1 32 1.4XLPE27X4 4.0 7/0.85 27 2500 35.2 40 1.4XLPE2X6 6.0 7/1.04 2 490 15.4 20S 0.7XLPE3X6* 6.0 7/1.04 3 639 16.6 20 0.7XLPE4X6 6.0 7/1.04 4 780 18.3 20 0.8XLPE5X6 6.0 7/1.04 5 900 20.0 25 0.8XLPE7X6 6.0 7/1.04 7 1100 21.9 25 0.9XLPE2X10 10.0 7/1.35 2 700 17.9 20 0.8XLPE3X10* 10.0 7/1.35 3 860 18.9 25 0.8XLPE4X10 10.0 7/1.35 4 1029 20.3 25 0.8XLPE5X10 10.0 7/1.35 5 1130 22.5 25 0.9XLPE7X10 10.0 7/1.35 7 1500 25.00 25 1.0XLPE2X16 16.0 7/1.70 2 900 20.0 25 0.8XLPE3X16* 16.0 7/1.70 3 1100 22.0 25 0.9XLPE4X16 16.0 7/1.70 4 1350 23.6 25 1.0XLPE5X16 16.0 7/1.70 5 1750 26.0 25 1.1XLPE7X16 16.0 7/1.70 7 2150 28.1 32 1.2XLPE INSULATEDMAINS ANDCONTROL CABLE(1.5MM2 TO 16MM2)Temperature limits:-15 to +90°C.Bending radius:6 x overall diameter.Core identification:2 core - Brown, Blue.3 core - Brown, Black, Grey.4 core - Brown, Black, Grey, Blue.5 core and above - up to 6mm2-White with Black numbers.5 core - 10mm2and 16mm2- Brown,Black, Grey, Blue, Green/Yellow1.5 & 2.5 - 2,3,4 core also available inwhite numbered cores to ESI 09-6Should not be installed attemperatures below 0°C orabove +60°C.Current ratings, see page 130.* Additionally these cables arestocked with Brown, Blue andGreen/Yellow core identification.
  14. 14. MAINS CABLES PVCStranded plain annealed copper conductors, XLPE insulated, PVC bedding,galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade toBS5467. Flame propagation to IEC 60502-1 and BS4066 PT1.15Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLECODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT(MM) (MM)6942X25 25 7/2.14 2 1000 20.4 25 0.96943X25 25 7/2.14 3 1500 23.6 32 1.06944X25 25 7/2.14 4 1950 26.1 32 1.26945X25 25 7/2.14 5 2370 31.0 32 1.26942X35 35 7/2.52 2 1490 27.9 32 1.26943X35 35 7/2.52 3 1940 29.6 32 1.26944X35 35 7/2.52 4 2350 32.1 32 1.46945X35 35 7/2.52 5 3150 35.0 40 1.46942X50 50 19/1.78 2 1750 25.8 32 1.26943X50 50 19/1.78 3 2225 28.5 32 1.26944X50 50 19/1.78 4 2875 32.0 32 1.46945X50 50 19/1.78 5 4260 40.0 50S 1.66942X70 70 19/2.14 2 2300 29.0 32 1.26943X70 70 19/2.14 3 3025 32.2 32 1.46944X70 70 19/2.14 4 4250 37.7 40 1.66945X70 70 19/2.14 5 5685 43.0 50S 1.86942X95 95 19/2.52 2 3100 33.1 40 1.66943X95 95 19/2.52 3 4275 37.0 40 1.66944X95 95 19/2.52 4 5475 41.7 50S 1.86945X95 95 19/2.52 5 7700 52.0 50 TC96942X120 120 37/2.03 2 3700 36.1 40 1.66943X120 120 37/2.03 3 5250 40.4 50S 1.86944X120 120 37/2.03 4 7175 47.1 50 2.06942X150 150 37/2.25 2 4400 39.3 40 1.86943X150 150 37/2.25 3 6650 45.5 50S 2.06944X150 150 37/2.25 4 8475 51.4 50 TC96942X185 185 37/2.52 2 5700 44.7 50S 2.06943X185 185 37/2.52 3 8000 49.8 50 2.06944X185 185 37/2.52 4 10350 56.6 63S TC106942X240 240 61/2.25 2 7100 49.0 50 2.06943X240 240 61/2.25 3 10150 55.1 63S TC96944X240 240 61/2.25 4 13000 63.0 63 TC106942X300 300 61/2.52 2 8500 53.5 63S TC96943X300 300 61/2.52 3 12400 60.2 63 TC106944X300 300 61/2.52 4 15750 68.8 75S TC116942X400 400 61/2.85 2 10650 58.0 63S TC106943X400 400 61/2.85 3 14770 65.8 75S TC116944X400 400 61/2.85 4 19950 75.4 90 TC12XLPE INSULATEDMAINS CABLE(25MM2 TO 400MM2)FIXEDWIRINGANDMAINSCABLESPVCTemperature limits:-15 to +90°C.Bending radius:8 x overall diameter.Core identification:2 core - Brown, Blue.3 core - Brown, Black, Grey.4 core - Brown, Black, Grey, Blue.5 core - Brown, Black, Grey, Blue,Green/Yellow.Should not be installed attemperatures below 0°C orabove +60°C.Current ratings, see page 130.
  15. 15. FIXEDWIRINGANDMAINSCABLESPVCPlease note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.MAINS CABLES WITH ALUMINIUM CONDUCTORS PVCSolid plain aluminium sectoral conductors, XLPE insulated, PVC bedding,galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade toBS5467. Flame propagation to BS4066 PT1 and IEC 60502-1.CCC CONDUCTOR NO. OF WEIGHT OVERALL GLAND SINGLECODE SIZE (MM2) CORES KG/KM DIAMETER SIZE CLEAT(MM) (MM)SAC4X25 25 4 1235 25.4 25 1.0SAC4X35 35 4 1515 28.9 32 1.2SAC4X50 50 4 1686 29.5 32 1.2SAC4X70 70 4 2401 34.7 40 1.4SAC4X95 95 4 2905 38.3 40 1.6SAC4X120 120 4 3705 42.2 50S 1.8SAC4X150 150 4 4550 46.0 50 2.0SAC4X185 185 4 5076 51.1 50 9SAC4X240 240 4 6104 56.4 63S 9SAC4X300 300 4 7212 61.4 63 1016XLPE INSULATEDMAINS CABLEWITH ALUMINIUMCONDUCTORS(25MM2 TO 300MM2)Temperature limits:-15 to +90°C.Bending radius:8 x overall diameter.Core identification:Brown, Black, Grey, Blue.Should not be installed attemperatures below 0°C orabove +60°C.Current ratings, see page 132.
  16. 16. FIXEDWIRINGANDMAINSCABLESPVC17Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.SINGLE CORE NON-ARMOURED MAINS CABLES PVCPlain annealed stranded compacted circular copper conductor, single core,XLPE insulated, PVC outer sheath Black. 600/1000 volts grade to BS7889/97.Flame propagation to BS4066 PT1 and IEC 60502-1.CCC CONDUCTOR STRANDING WEIGHT OVERALL GLAND SINGLE TREFOILCODE SIZE (MM2) (MM) KG/KM DIAMETER SIZE CLEAT CLEAT(MM) (MM)6181X50 50 19/1.78 540 13.6 25 0.66181X70 70 19/2.14 750 15.6 25 0.76181X95 95 19/2.52 1010 17.5 25 0.76181X120 120 37/2.03 1250 19.2 32 0.86181X150 150 37/2.25 1530 21.3 32 0.96181X185 185 37/2.52 1900 23.4 32 1.0 2076181X240 240 61/2.25 2470 26.3 40 1.1 5026181X300 300 61/2.52 3080 29.0 40 1.2 5046181X400 400 61/2.85 3890 32.7 50S 1.4 5066181X500 500 61/3.20 4970 36.6 50S 1.6 5096181X630 630 127/2.52 6370 41.3 50 1.8 5116181X800 800 127/2.85 8150 46.3 63S 2.0 5156181X1000 1000 127/3.20 9860 53.0 63 TC9 519XLPE INSULATEDSINGLE CORENON-ARMOUREDMAINS CABLE(50MM2 TO 1000MM2)Temperature limits:-15 to +90°C.Bending radius:8 x overall diameter.Core identification:Brown inner / Black outer.Should not be installed attemperatures below 0°C orabove +60°C.Current ratings, see page 134.
  17. 17. 18FIXEDWIRINGANDMAINSCABLESPVCPlease note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.XLPE INSULATEDSINGLE CORE ARMOUREDMAINS CABLE(50MM2 TO 1000MM2)SINGLE CORE ARMOURED MAINS CABLE PVCStranded plain annealed compacted circular copper conductor, XLPE insulated,PVC bedding, aluminium wire armour, PVC outer sheath. Black. 600/1000 voltsgrade to BS5467. Flame propagation to BS4066 PT1 and IEC 60502-1.CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE TREFOILCODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT CLEAT(MM) (MM)6941AX50 50 19/1.78 1 800 17.7 20 0.86941AX70 70 19/2.14 1 940 19.6 25 0.96941AX95 95 19/2.52 1 1220 21.5 25 1.06941AX120 120 37/2.03 1 1490 23.2 25 1.26941AX150 150 37/2.25 1 1870 26.3 32 1.2 5026941AX185 185 37/2.52 1 2290 28.7 32 1.4 5046941AX240 240 61/2.25 1 2880 31.4 40 1.4 5056941AX300 300 61/2.52 1 3520 34.1 40 1.8 5076941AX400 400 61/2.85 1 4520 38.9 50S 1.8 5106941AX500 500 61/3.20 1 5680 42.8 50S 1.8 5126941AX630 630 127/2.52 1 7120 47.3 50 2.0 5156941AX800 800 127/2.85 1 9220 53.9 63S TC9 5196941AX1000 1000 127/3.20 1 11270 58.8 63S TC10 523Temperature limits:-15 to +90°C.Bending radius:6 x overall diameter.Core identification:Brown inner / Black outer.Should not be installed attemperatures below 0°C orabove +60°C.Current ratings, see page 129.
  18. 18. 19FIXEDWIRINGANDMAINSCABLESPVCPlease note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.MAINS CABLES FOR MINES & QUARRIES PVCPlain annealed stranded copper conductors, XLPE insulated, PVC extrudedbedding, galvanised steel wire armour incorporating tinned copper wires toprovide 60% conductivity of any one phase, PVC outer sheath. Black. 600/1000volts grade generally to BS5467 and BC295. Flame propagation to BS4066 PT1and IEC 60502-1.CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLECODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT(MM) (MM)NCB3X10/1 10 7/1.04 3 896 18.9 20 0.8NCB4X10/1 10 7/1.04 4 1038 20.3 20 0.8NCB3X16/1 16 7/1.70 3 1205 23.1 25 1.0NCB4X16/1 16 7/1.70 4 1675 26.3 25 1.1NCB3X25 25 7/2.14 3 1550 26.9 25 1.1NCB4X25 25 7/2.14 4 1880 29.1 32 1.2NCB3X35 35 7/2.52 3 1940 29.6 32 1.2NCB4X35 35 7/2.52 4 2350 32.1 32 1.4NCB3X50 50 19/1.78 3 2360 28.4 32 1.2NCB4X50 50 19/1.78 4 2950 31.3 32 1.4NCB3X70 70 19/2.14 3 3120 32.0 32 1.4NCB4X70 70 19/2.14 4 4230 36.8 40 1.6NCB3X95 95 19/2.52 3 4310 36.7 40 1.6NCB4X95 95 19/2.52 4 5390 40.6 50S 1.6NCB3X120 120 37/2.03 3 5160 40.0 50S 1.6NCB4X120 120 37/2.03 4 6980 45.8 50S 2.0NCB3X150 150 37/2.25 3 6610 45.1 50S 1.8NCB4X150 150 37/2.25 4 8300 49.9 50 2.0NCB3X185 185 37/2.52 3 7920 49.3 50 2.0NCB4X185 185 37/2.52 4 10070 54.9 63S TC9NCB3X240 240 61/2.25 3 9930 54.5 63S TC9NCB4X240 240 61/2.25 4 12680 61.0 63 TC10NCB3X300 300 61/2.52 3 11970 59.5 63 TC10NCB4X300 300 61/2.52 4 15380 66.5 75S TC11XLPE INSULATED MAINSCABLE WITH 60%CONDUCTIVITYIN ARMOUR.(MINES & QUARRIES &BRITISH COAL)(10MM2 TO 300MM2)Temperature limits:-15 to +70°C.Bending radius:up to 16mm2- 6 x overall diameter.over 16mm2- 8 x overall diameter.Core identification:3 core - Brown, Black, Grey.4 core - Brown, Black, Grey, Blue.Should not be installed attemperatures below 0°C orabove +60°C.Current ratings, see page 130.
  19. 19. 20FIXEDWIRINGANDMAINSCABLESPVCPlease note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.EEMUA133 CONTROL CABLES PVCPlain annealed stranded copper conductors, XLPE insulated, lead sheathed,PVC bedding, galvanised steel wire armour, PVC outer sheath. Cores whitewith black numbers. 600/1000 volts grade to BS5467 and EEMUA 133.Flame propogation to BS 4066 PT1 and IEC 60502-1.CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLECODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT(MM) (MM)EEMUA2X1/5ESI 1.5 7/0.53 2 566 15.3 20S 0.6EEMUA3X1/5ESI 1.5 7/0.53 3 593 15.8 20 0.6EEMUA4X1/5ESI 1.5 7/0.53 4 813 16.0 20 0.7EEMUA5X1/5 1.5 7/0.53 5 695 16.8 20 0.7EEMUA7X1/5 1.5 7/0.53 7 1072 17.7 20 0.8EEMUA12X1/5 1.5 7/0.53 12 1387 22.3 25 0.9EEMUA19X1/5 1.5 7/0.53 19 1686 24.8 25 1.0EEMUA27X1/5 1.5 7/0.53 27 2418 30.0 32 1.2EEMUA37X1/5 1.5 7/0.53 37 2850 32.7 40 1.4EEMUA2X2/5ESI 2.5 7/0.67 2 772 15.8 20 0.7EEMUA3X2/5ESI 2.5 7/0.67 3 842 16.3 20 0.7EEMUA4X2/5ESI 2.5 7/0.67 4 934 17.2 20 0.7EEMUA5X2/5 2.5 7/0.67 5 1038 18.4 20 0.8EEMUA7X2/5 2.5 7/0.67 7 1324 19.3 25 0.9EEMUA12X2/5 2.5 7/0.67 12 1750 23.9 25 1.0EEMUA19X2/5 2.5 7/0.67 19 2489 28.9 32 1.2EEMUA27X2/5 2.5 7/0.67 27 3248 33.3 40 1.4EEMUA37X2/5 2.5 7/0.67 37 3840 36.7 40 1.6EEMUA5X4 4.0 7/0.85 5 1014 20.6 25 0.9EEMUA7X4 4.0 7/0.85 7 1110 21.5 25 0.9XLPE INSULATED LEADSHEATHED CONTROLCABLE FORPETRO-CHEMICALINDUSTRIES(1.5MM2 TO 4MM2)Temperature limits:-15 to +90°C.Bending radius:12 x overall diameter.Core identification:White with Black numbers.Should not be installed attemperatures below 0°C orabove +60°C.
  20. 20. 21FIXEDWIRINGANDMAINSCABLESPVCEEMUA133 MAINS CABLES PVCPlain annealed stranded copper conductors, XLPE insulated, lead sheathed,PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000volts grade to BS5467 and EEMUA 133 (formerly OCMA 4B). Flamepropagation to BS4066 PT1 and IEC 60502-1.XLPE INSULATED LEADSHEATHED MAINS CABLEFOR PETRO-CHEMICALINDUSTRIES(1.5MM2 TO 16MM2)Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLECODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT(MM) (MM)EEMUA2X1/5 1.5 7/0.53 2 690 14.5 20S 0.6EEMUA3X1/5 1.5 7/0.53 3 744 15.0 20 0.6EEMUA4X1/5 1.5 7/0.53 4 813 16.0 20 0.7EEMUA2X2/5 2.5 7/0.67 2 772 15.8 20 0.7EEMUA3X2/5 2.5 7/0.67 3 842 16.3 20 0.7EEMUA4X2/5 2.5 7/0.67 4 934 17.2 20 0.7EEMUA2X4 4.0 7/0.85 2 883 20.4 20 0.7EEMUA3X4 4.0 7/0.85 3 1190 21.0 20 0.7EEMUA4X4 4.0 7/0.85 4 1310 22.1 20 0.8EEMUA2X6 6.0 7/1.04 2 1001 18.2 20 0.8EEMUA3X6 6.0 7/1.04 3 1122 18.8 20 0.8EEMUA4X6 6.0 7/1.04 4 1402 20.9 25 0.9EEMUA2X10 10.0 7/1.35 2 1227 20.1 20 0.8EEMUA3X10 10.0 7/1.35 3 1493 21.7 25 0.9EEMUA4X10 10.0 7/1.35 4 1710 23.1 25 1.0EEMUA2X16 16.0 7/1.70 2 1565 23.2 25 1.0EEMUA3X16 16.0 7/1.70 3 1813 24.4 25 1.0EEMUA4X16 16.0 7/1.70 4 2191 26.4 25 1.1Temperature limits:-15 to +90°C.Bending radius:12 x overall diameter.Core identification:2 core - Brown, Blue.3 core - Brown, Black, Grey.4 core - Brown, Black, Grey, Blue.Should not be installed attemperatures below 0°C orabove +60°C.
  21. 21. 22FIXEDWIRINGANDMAINSCABLESPVCPlease note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.EEMUA133 MAINS CABLES PVCPlain annealed stranded copper conductors, XLPE insulated, lead sheathed,PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000volts grade to BS5467 and EEMUA 133 (formerly OCMA 4B). Flamepropagation to BS4066 PT1 and IEC 60502-1.CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLECODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT(MM) (MM)EEMUA2X25 25 7/2.14 2 2094 27.1 25 1.1EEMUA3X25 25 7/2.14 3 2673 29.7 32 1.2EEMUA4X25 25 7/2.14 4 3204 32.1 32 1.4EEMUA2X35 35 19/1.53 2 2868 30.9 32 1.4EEMUA3X35 35 19/1.53 3 3338 32.6 32 1.4EEMUA4X35 35 19/1.53 4 4043 35.3 40 1.4EEMUA2X50 50 19/1.78 2 2783 28.1 32 1.2EEMUA3X50 50 19/1.78 3 3572 31.4 32 1.4EEMUA4X50 50 19/1.78 4 4456 34.5 40 1.4EEMUA2X70 70 19/2.14 2 3566 31.1 32 1.4EEMUA3X70 70 19/2.14 3 4639 35.2 40 1.4EEMUA4X70 70 19/2.14 4 6160 40.2 50S 1.6EEMUA2X95 95 19/2.52 2 4678 35.1 40 1.4EEMUA3X95 95 19/2.52 3 6023 40.1 50S 1.6EEMUA4X95 95 19/2.52 4 7592 44.2 50S 1.8EEMUA2X120 120 37/2.03 2 5641 38.5 50S 1.6EEMUA3X120 120 37/2.03 3 7392 43.6 50S 1.8EEMUA4X120 120 37/2.03 4 9802 49.5 50 2.0EEMUA2X150 150 37/2.25 2 6660 41.8 50S 1.8EEMUA3X150 150 37/2.25 3 9242 48.9 50 2.0EEMUA4X150 150 37/2.25 4 11757 54.1 63S TC9EEMUA2X185 185 37/2.52 2 8457 47.1 50 2.0EEMUA3X185 185 37/2.52 3 11054 53.1 63S TC9EEMUA4X185 185 37/2.52 4 14117 59.3 63 TC10EEMUA2X240 240 61/2.25 2 10286 52.3 63S TC9EEMUA3X240 240 61/2.25 3 13792 55.9 63S TC9EEMUA4X240 240 61/2.25 4 17700 65.8 75S TC11EEMUA2X300 300 61/2.52 2 12245 56.7 63S TC9EEMUA3X300 300 61/2.52 3 16519 64.1 63 TC11EEMUA4X300 300 61/2.52 4 21173 71.5 75S TC12XLPE INSULATEDLEAD SHEATHED MAINSCABLE FORPETRO-CHEMICALINDUSTRIES(25MM2 TO 300MM2)Temperature limits:-15 to +90°C.Bending radius:12 x overall diameter.Core identification:2 core - Brown, Blue3 core - Brown, Black, Grey.4 core - Brown, Black, Grey, Blue.Should not be installed attemperatures below 0°C orabove +60°C.
  22. 22. 23FIXEDWIRINGANDMAINSCABLESPVCPlease note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.SINGLE CORE NON-ARMOURED CATHODICPROTECTION CABLES PVCPlain annealed compacted circular copper conductor, XLPE insulated, PVC outersheath, 600/1000 volts grade generally to BS5467 & IEC 502/1. ColoursBlack/Black or Red/Red.CCC CONDUCTOR STRANDING WEIGHT OVERALL GLANDCODE SIZE (MM2) (MM) KG/KM DIAMETER SIZE(MM) (MM)6181X6 6 7/1.04 105 7.2 20/166181X10 10 7/1.35 150 8.1 20/166181X16 16 7/1.70 210 9.0 20S6181X25 25 7/2.14 305 10.6 20S6181X35 35 7/2.52 395 11.6 206181X50 50 19/1.78 515 13.0 206181X70 70 19/2.14 725 14.9 256181X95 95 19/2.52 1230 17.5 256181X120 120 37/2.03 1355 19.2 326181X150 150 37/2.25 1695 21.3 326181X185 185 37/2.52 2110 23.4 32SINGLE CORE ARMOURED CATHODICPROTECTION CABLES PVCPlain annealed compacted circular copper conductor, XLPE insulated, PVCbedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000volts grade generally to IEC 502/1 & BS5467.CCC CONDUCTOR STRANDING WEIGHT OVERALL GLANDCODE SIZE (MM2) (MM) KG/KM DIAMETER SIZE(MM) (MM)6941X6 6 7/1.04 285 11.5 20/166941X10 10 7/1.35 355 12.5 20/166941X16 16 7/1.70 435 13.5 20S6941X25 25 7/2.14 585 15.0 20S6941X35 35 7/2.52 685 16.0 206941X50 50 19/1.78 835 17.5 206941X70 70 19/2.14 1080 19.5 206941X95 95 19/2.52 1375 21.6 256941X120 120 37/2.03 1685 23.4 256941X150 150 37/2.25 2120 26.4 256941X185 185 37/2.52 2505 28.9 32XLPE INSULATED NON-ARMOURED ANDARMOURED SINGLE CORECABLE FOR CATHODICPROTECTION(6MM2 TO 185MM2)Bending radius:4 x overall diameter.Should not be installed attemperatures below 0°C orabove +60°C.Bending radius:4 x overall diameter.Should not be installed attemperatures below 0°C orabove +60°C.
  23. 23. 24FIXEDWIRINGANDMAINSCABLESPVCSPLIT CONCENTRIC CABLES PVCPlain annealed stranded copper phase conductor, XLPE insulated surroundedby a concentric layer of plain annealed solid copper neutral conductors. XLPEinsulated and plain annealed solid strand bare copper earth conductors, PVCouter sheath. Black. 600/1000 volts grade to BS 7870.CCC CONDUCTOR STRANDING WEIGHT OVERALL GLANDCODE SIZE (MM2) (MM) KG/KM DIAMETER SIZE(MM) (MM)4 SPLITCON 4 7/0.85 206 9.6 20S6 SPLITCON 6 7/1.04 281 11.4 2010 SPLITCON 10 7/1.35 394 12.7 2016 SPLITCON 16 7/1.70 583 14.6 2525 SPLITCON 25 *7/2.14 843 18.7 3235 SPLITCON 35 7/2.52 1300 23.0 40STRAIGHT CONCENTRIC CABLES PVCPlain annealed stranded copper phase conductor, PVC insulated surrounded bya concentric layer of plain annealed solid copper neutral/earth conductors inconcentric layer, PVC outer sheath. Black. 600/1000 volts grade to BS 7870 &ESI 09-7. Combined neutral and earth (CNE).CCC CONDUCTOR STRANDING WEIGHT OVERALL GLANDCODE SIZE (MM2) (MM) KG/KM DIAMETER SIZE(MM) (MM)4 STRCON 4 7/0.85 180 9.0 20S6 STRCON 6 7/1.04 230 10.0 20S16 STRCON 16 7/1.70 440 12.0 2025 STRCON 25 7/2.14 600 15.0 2535 STRCON 35 7/2.25 850 16.0 25Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.XLPE INSULATED SINGLEPHASE SPLIT ANDSTRAIGHT CONCENTRICSERVICE CABLE(4MM2 TO 35MM2)* Stranding of neutral is the same asphase conductor except 25 sq mmwhich has 11 x 1.70mm.Conductor identification:Brown Live/Blue Neutral.Should not be installed attemperatures below 0°C orabove +60°C.Also available in Violet outer sheathin 6mm, 10mm, 16mm & 25mm.Temperature limits:-15 to +70°C.Bending radius:10 x overall diameter.Should not be installed attemperatures below 0°C orabove +60°C.
  24. 24. 25FIXED WIRING ANDMAINS CABLES3300V PVCFIXEDWIRINGANDMAINSCABLESPVC
  25. 25. 26SINGLE CORE ARMOURED MAINS CABLES 1900/3300VStranded plain annealed copper conductors, XLPE insulated, PVC bedding,galvanised steel wire armour, PVC outer sheath. Black. 1900/3300 volts gradeto BS5467. Flame propagation to BS4066 PT1 and IEC 60502-1.CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE TREFOILCODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT CLEAT(MM) (MM)6941AX120/3 120 37/2.03 1 1490 23.2 25 1.26941AX150/3 150 37/2.25 1 1870 26.3 32 1.2 5026941AX185/3 185 37/2.52 1 2290 28.7 32 1.4 5046941AX240/3 240 61/2.25 1 2880 31.4 40 1.4 5056941AX300/3 300 61/2.52 1 3520 34.1 40 1.8 5076941AX400/3 400 61/2.85 1 4520 38.9 50S 1.8 5106941AX500/3 500 61/3.20 1 5680 42.8 50S 1.8 5126941AX630/3 630 127/2.52 1 7120 47.3 50 2.0 515Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.XLPE INSULATEDSINGLE CORE ARMOUREDMAINS CABLE3300V(120MM2 TO 630MM2)Temperature limits:-25 to +90°C.Bending radius:6 x overall diameter.Core identification:Brown inner/Black outer.Should not be installed attemperatures below 0°C orabove +60°C.FIXEDWIRINGANDMAINSCABLESPVC
  26. 26. 27XLPE INSULATEDMAINS CABLE3300 VOLT(16MM2 TO 400MM2)Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.3 CORE MAINS CABLES 1900/3300V PVCStranded plain annealed copper conductors, XLPE insulated, PVC bedding,galvanised steel wire armour, PVC outer sheath. Black. 1900/3300 volts gradeto BS5467. Flame propagation to BS4066 PT1 and IEC 60502-1.CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLECODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT(MM) (MM)XLPE3X16/3 16 7/1.70 3 1600 29.5 32 1.2XLPE3X25/3 25 7/2.14 3 2060 32.3 32 1.4XLPE3X35/3 35 7/2.52 3 2330 35.0 40 1.4XLPE3X50/3 50 19/1.78 3 3040 34.9 40 1.4XLPE3X70/3 70 19/2.14 3 3800 38.0 40 1.6XLPE3X95/3 95 19/2.52 3 4730 41.4 50S 1.8XLPE3X120/3 120 37/2.03 3 6070 45.6 50S 1.8XLPE3X150/3 150 37/2.25 3 7010 48.3 50 2.0XLPE3X185/3 185 37/2.52 3 8270 51.6 50 TC9XLPE3X240/3 240 61/2.25 3 10310 56.5 63S TC9XLPE3X300/3 300 61/2.52 3 12300 60.7 63 TC10XLPE3X400/3 400 61/2.85 3 14780 65.8 75S TC11Temperature limits:-15 to +90°C.Bending radius:8 x overall diameter.Core identification:Brown, Black, Grey.Should not be installed attemperatures below 0°C orabove +60°C.Current ratings, see page 134.FIXEDWIRINGANDMAINSCABLESPVC
  27. 27. 28FIXEDWIRINGANDMAINSCABLESPVCMAINS CABLES FOR MINES & QUARRIES 1900/3300VPlain annealed stranded copper conductors, XLPE insulated, PVC extrudedbedding, galvanised steel wire armour incorporating tinned copper wires toprovide 60% conductivity of any one phase, PVC outer sheath. Black.1900/3300 volts grade generally to BS5467 and BC295. Flame propagation toBS4066 PT1 and IEC 60502-1.CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLECODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT(MM) (MM)NCB3X16/3 16 7/1.70 3 1600 29.5 32 1.2NCB3X25/3 25 19/1.35 3 2060 32.3 32 1.4NCB3X35/3 35 19/1.53 3 2330 35.0 40 1.4NCB3X50/3 50 19/1.78 3 3040 34.9 40 1.4NCB3X70/3 70 19/2.14 3 3800 38.0 40 1.6NCB3X95/3 95 19/2.52 3 4730 41.4 50S 1.8NCB3X120/3 120 37/2.03 3 6070 45.6 50S 1.8NCB3X150/3 150 37/2.25 3 7110 48.3 50 2.0NCB3X185/3 185 37/2.52 3 8270 51.6 50 TC9NCB3X240/3 240 61/2.25 3 10310 56.5 63S TC9NCB3X300/3 300 61/2.52 3 12300 60.7 63 TC10XLPE INSULATED MAINSCABLE 3300VWITH 60%CONDUCTIVITYIN ARMOUR.(MINES & QUARRIES &BRITISH COAL)(16MM2 TO 300MM2)Temperature limits:-15 to +70°C.Bending radius:up to 16mm2- 6 x overall diameter.over 16mm2- 8 x overall diameter.Core identification:3 core - Brown, Black, GreyShould not be installed attemperatures below 0°C orabove +60°C.Current ratings, see page 134.Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
  28. 28. 29Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.EEMUA133 MAINS CABLES 1900/3300V PVCPlain annealed stranded copper conductors, XLPE insulated, lead sheathed,PVC bedding, galvanised steel wire armour, PVC outer sheath. Black.1900/3300 volts grade to BS5467 and EEMUA 133 (formerly OCMA 4B).Flame propagation to BS4066 PT1 and IEC 60502-1.CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLECODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT(MM) (MM)EEMUA3X25/3 25 7/2.14 3 3400 32.5 32 1.4EEMUA3X35/3 35 19/1.53 3 3560 38.4 40 1.6EEMUA3X50/3 50 19/1.78 3 4520 38.1 40 1.6EEMUA3X70/3 70 19/2.14 3 5550 41.4 50S 1.8EEMUA3X95/3 95 19/2.52 3 6770 45.0 50S 2.0EEMUA3X120/3 120 37/2.03 3 8390 49.4 50 2.0EEMUA3X150/3 150 37/2.25 3 9630 52.3 50 TC9EEMUA3X185/3 185 37/2.52 3 11270 55.8 63S TC9EEMUA3X240/3 240 61/2.25 3 13720 60.9 63 TC10EEMUA3X300/3 300 61/2.52 3 16380 65.3 75S TC11XLPE INSULATEDLEAD SHEATHED MAINSCABLE FORPETRO-CHEMICALINDUSTRIES3300 VOLT(25MM2 TO 300MM2)Temperature limits:-15 to +90°C.Bending radius:12 x overall diameter.Core identification:Brown, Black, Grey.Should not be installed attemperatures below 0°C orabove +60°C.FIXEDWIRINGANDMAINSCABLESPVC
  29. 29. 31FIXED WIRING ANDMAINS CABLESLSZHFIXEDWIRINGANDMAINSCABLESLSZH
  30. 30. 32FIXEDWIRINGANDMAINSCABLESLSZHPlease note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.LOW SMOKE ZEROHALOGEN INSULATEDWIRING CABLE 6491B(1.5MM2 TO 630MM2)6491B (HO7Z-R) LSZHStranded plain annealed compacted circular copper conductor, low smoke andzero halogen (LSZH) outer sheath. 450/750 volts grade to BS7211. Flamepropagation to BS4066 PT1 and IEC 60502-1 Harmonised code HO7 Z-R.CCC CONDUCTOR STRANDING WEIGHT OVERALLCODE SIZE (MM2) (MM) KG/KM DIAMETER(MM)6491B1/5 1.5 7/0.53 22 3.006491B2/5 2.5 7/0.67 33 3.656491B4 4.0 7/0.85 49 4.206491B6 6.0 7/1.04 69 4.756491B10 10.0 7/1.35 116 6.156491B16 16.0 7/1.70 175 7.106491B25 25.0 7/2.14 273 8.906491B35 35.0 7/2.52 367 9.956491B50 50.0 19/1.78 510 11.706491B70 70.0 19/2.14 715 13.356491B95 95.0 19/2.52 990 15.606491B120 120.0 37/2.03 1230 17.206491B150 150.0 37/2.25 1510 19.106491B185 185.0 37/2.52 1900 21.306491B240 240.0 61/2.25 2490 24.306491B300 300.0 61/2.52 3050 27.056491B400 400.0 61/2.85 3842 30.356491B500 500.0 61/3.20 4900 32.806491B630 630.0 127/2.50 6334 36.50Temperature limits:-15 to +70°C.Bending radius:up to 10mm2- 3 x overall diameterabove 25mm2- 6 x overall diameterStandard colours available:1.5mm2& 2.5mm2- Brown, Black,Grey, Blue, Green/Yellow, White,Orange, Turquoise, Violet, Pink.Should not be installed attemperatures below 0°C orabove +40°C.Current ratings, see page 128.
  31. 31. 33SURFACE WIRING CABLES LSZH 624*BPlain annealed compacted copper conductor, XLPE insulated, one, two or threecores laid flat with an uninsulated circuit protective conductor and (LSZH)sheathed. White. Ref 6241/2/3B 300/500V to BS7211 low smoke and zerohalogen (LSZH). Flame propogation to BS4066 PT1 and IEC 60502-1CCC CONDUCTOR STRANDING NO.OF WEIGHT OVERALLCODE SIZE (MM2) (MM) CORES KG/KM DIAMETER(MM)6241B1/5BR 1.5 1/1.37 1 51 4.65 X 5.806241B1/5BY 1.5 1/1.37 1 51 4.65 X 5.806242B1/WH 1.0 1/1.13 2 69 4.10 X 8.656242B1/5WH 1.5 1/1.37 2 85 4.55 X 8.806242B1/5BRBR 1.5 1/1.37 2 85 4.55 X 8.806242B2/5WH 2.5 1/1.77 2 120 5.40 X 10.506242B4WH 4.0 7/0.85 2 175 6.10 X 12.006242B6WH 6.0 7/1.04 2 240 6.90 X 13.806242B10WH 10.0 7/1.35 2 390 8.40 X 18.506242B16WH 16.0 7/1.70 2 560 9.70 X 20.606243B1WH 1.0 1/1.13 3 92 4.60 X 10.206243B1/5WH 1.5 1/1.37 3 115 5.75 X 11.456243B2/5WH 2.5 1/1.77 3 170 5.30 X 12.80CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND CLEATCODE SIZE (MM2) (MM) CORES KG/KM DIAMETER REF SIZE(MM) (MM)6181B1 1.0 1/1.13 1 28 4.5 20/166181B1/5 1.5 1/1.38 1 34 5.1 20/166181B2/5 2.5 1/1.78 1 49 6.0 20/166181B4 4.0 7/0.85 1 75 6.8 20/166181B6 6.0 7/1.04 1 99 7.4 20/166181B10 10.0 7/1.35 1 155 8.8 20S6181B16 16.0 7/1.04 1 225 10.5 20S 0.56181B25 25.0 7/2.14 1 340 12.5 20 0.56181B35 35.0 7/2.52 1 440 13.5 25 0.6Temperature limits:-25 to +90°C.Bending radius:up to 10mm2- 3 x overall diameterover 10mm2- 4 x overall diameterShould not be installed attemperatures below 0°C orabove +40°C.Temperature limits:-25 to +90°C.Bending radius:Fixed = 3 x diameterShould not be installed attemperatures below 0°C orabove +40°C.Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.FIXEDWIRINGANDMAINSCABLESLSZHXLPE INSULATEDLSZH SHEATHED SURFACEWIRING CABLE TYPE6181B(1MM2 TO 35MM2)XLPE INSULATEDLSZH SHEATHEDWIRING CABLE TYPE624*B(1MM2 TO 16MM2)SURFACE WIRING CABLES LSZH 6181BPlain annealed stranded circular copper conductor, single core, XLPE insulated,(LSZH) sheathed, Ref 6181B. 300/500 volts grade o BS 7889. Brown/White orGrey/White. Flame propagation to BS4066 PT1 and IEC 60502-1 low smokeand zero halogen (LSZH).
  32. 32. FIXEDWIRINGANDMAINSCABLESLSZH 34Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.MAINS AND CONTROL CABLES LSZHPlain annealed stranded copper conductors, XLPE insulated, low smoke andzero halogen (LSZH) bedding, galvanised steel wire armour, low smoke andzero halogen (LSZH) outer sheath. Black. 600/1000 volts grade to BS6724.Flame propagation to BS4066 PT1 and IEC 60502-1. (Bunched cables toBS4066 PT3 and IEC 60502-3).CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLECODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT(MM) (MM)LSF2X1/5 1.5 7/0.53 2 295 12.0 20/16 0.5LSF3X1/5 1.5 7/0.53 3 324 12.9 20S 0.6LSF4X1/5 1.5 7/0.53 4 367 13.7 20S 0.6LSF5X1/5 1.5 7/0.53 5 380 14.2 20 0.6LSF7X1/5 1.5 7/0.53 7 463 15.6 20 0.7LSF12X1/5 1.5 7/0.53 12 791 20.1 20 0.8LSF19X1/5 1.5 7/0.53 19 1030 23.2 25 1.0LSF27X1/5 1.5 7/0.53 27 1420 27.7 32 1.2LSF37X1/5 1.5 7/0.53 37 1750 30.3 32 1.4LSF48X1/5 1.5 7/0.53 48 2100 32.3 32 1.4LSF2X2/5 2.5 7/0.67 2 340 13.2 20S 0.6LSF3X2/5 2.5 7/0.67 3 392 13.8 20S 0.6LSF4X2/5 2.5 7/0.67 4 440 14.7 20S 0.6LSF5X2/5 2.5 7/0.67 5 480 16.1 20 0.7LSF7X2/5 2.5 7/0.67 7 584 17.1 20 0.7LSF12X2/5 2.5 7/0.67 12 950 22.0 25 0.9LSF19X2/5 2.5 7/0.67 19 1500 26.5 25 1.1LSF27X2/5 2.5 7/0.67 27 1928 30.7 32 1.4LSF37X2/5 2.5 7/0.67 37 2300 33.8 40 1.4LSF48X2/5 2.5 7/0.67 48 3010 39.0 40 1.6LSF2X4 4.0 7/0.85 2 419 14.3 20S 0.6LSF3X4 4.0 7/0.85 3 460 14.9 20S 0.7LSF4X4 4.0 7/0.85 4 550 16.2 20 0.7LSF5X4 4.0 7/0.85 5 600 18.0 20 0.8LSF7X4 4.0 7/0.85 7 700 19.7 20 0.9LSF12X4 4.0 7/0.85 12 1300 25.0 25 1.0LSF27X4 4.0 7/0.85 27 2500 35.2 40 1.4LSF2X6 6.0 7/1.04 2 490 15.4 20 0.7LSF3X6 6.0 7/1.04 3 639 16.6 20 0.7LSF4X6 6.0 7/1.04 4 780 18.3 20 0.8LSF5X6 6.0 7/1.04 5 900 20.0 25 0.9LSF7X6 6.0 7/1.04 7 1100 21.9 25 0.9LSF2X10 10.0 7/1.35 2 700 17.9 20 0.8LSF3X10 10.0 7/1.35 3 860 18.9 25 0.8LSF4X10 10.0 7/1.35 4 1029 20.3 25 0.9LSF5X10 10.0 7/1.35 5 1130 22.5 25 0.9LSF7X10 10.0 7/1.35 7 1500 25.00 25 1.0LSF2X16 16.0 7/1.70 2 900 20.0 20 0.8LSF3X16 16.0 7/1.70 3 1100 22.0 25 0.9LSF4X16 16.0 7/1.70 4 1350 23.6 25 1.0LSF5X16 16.0 7/1.70 5 1750 26.0 25 1.1LSF7X16 16.0 7/1.70 7 2150 28.1 32 1.2XLPE INSULATEDLOW SMOKE ZEROHALOGEN MAINS ANDCONTROL CABLE(1.5MM2 TO 16MM2)Temperature limits:-25 to +90°CBending radius:6 x overall diameter.Core identification:2 core - Brown, Blue.3 core - Brown, Black, Grey.4 core - Brown, Black, Grey, Blue.5 core and above - Up to 6mm2-White with Black numbers.5 - 10mm2and 16mm2- Brown,Black, Grey, Blue, Green/Yellow.1.5 & 2.5 - 2,3,4 core also available inwhite numbered cores to ESI 09-6Should not be installed attemperatures below 0°C orabove +40°C.Current ratings, see page 130.
  33. 33. MAINS CABLES LSZHStranded plain annealed copper conductors, XLPE insulated, low smoke andzero halogen (LSZH) extruded bedding, galvanised steel wire armour, lowsmoke and zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade toBS6724. Flame propagation to BS4066 PT1 and IEC 60502-1. (Bunched cablesto BS4066 PT3 and IEC 60502-3).CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLECODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT(MM) (MM)LSF2X25 25 7/2.14 2 1250 24.3 25 1.2LSF3X25 25 7/2.14 3 1720 26.9 32 1.2LSF4X25 25 7/2.14 4 2090 29.1 32 1.2LSF5X25 25 7/2.14 5 2370 31.0 32 1.4LSF2X35 35 7/2.52 2 1720 27.9 32 1.2LSF3X35 35 7/2.52 3 2130 29.6 32 1.2LSF4X35 35 7/2.52 4 2590 32.1 32 1.4LSF5X35 35 7/2.52 5 3150 35.0 40 1.4LSF2X50 50 19/1.78 2 1800 25.3 32 1.2LSF3X50 50 19/1.78 3 2380 28.4 32 1.2LSF4X50 50 19/1.78 4 2960 31.3 32 1.4LSF5X50 50 19/1.78 5 4260 40.0 50S 1.6LSF2X70 70 19/2.14 2 2330 28.1 32 1.2LSF3X70 70 19/2.14 3 3150 32.0 32 1.4LSF4X70 70 19/2.14 4 4240 36.8 40 1.6LSF5X70 70 19/2.14 5 5685 43.0 50S 1.8LSF2X95 95 19/2.52 2 3170 31.9 32 1.6LSF3X95 95 19/2.52 3 4320 36.7 40 1.6LSF4X95 95 19/2.52 4 5410 40.6 50S 1.8LSF5X95 95 19/2.52 5 7700 52.0 50 TC9LSF2X120 120 37/2.03 2 3810 35.1 40 1.6LSF3X120 120 37/2.03 3 5200 40.0 50S 1.8LSF4X120 120 37/2.03 4 6980 45.8 50 2.0LSF5X120 120 37/2.03 5 9030 56.7 63S TC9LSF2X150 150 37/2.25 2 4530 38.2 40 1.8LSF3X150 150 37/2.25 3 6630 45.1 50S 2.0LSF4X150 150 37/2.25 4 8320 49.9 50 TC9LSF5X150 150 37/2.25 5 10752 64.31 63 TC11LSF2X185 185 37/2.52 2 5860 43.3 50S 2.0LSF3X185 185 37/2.52 3 7980 49.3 50 2.0LSF4X185 185 37/2.52 4 10080 54.9 63S/63 TC9LSF2X240 240 61/2.25 2 7300 48.3 50 2.0LSF3X240 240 61/2.25 3 9960 54.5 63S TC9LSF4X240 240 61/2.25 4 12690 61.0 63 TC10LSF2X300 300 61/2.52 2 8790 52.5 63S TC9LSF3X300 300 61/2.52 3 12060 59.5 63 TC10LSF4X300 300 61/2.52 4 15420 66.5 75S TC11LSF3X400 400 61/2.85 3 15330 68.0 75S TC11LSF4X400 400 61/2.85 4 20215 77.5 90 TC12MXLPE INSULATEDLOW SMOKE ZEROHALOGEN MAINS CABLE(25MM2 TO 400MM2)FIXEDWIRINGANDMAINSCABLESLSZH35Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.Temperature limits:-25 to +90°C.Bending radius:8 x overall diameter.Core identification:2 core - Brown, Blue.3 core - Brown, Black, Grey.4 core - Brown, Black, Grey, Blue.5 core - Brown, Black, Grey, Blue,Green/Yellow.Should not be installed attemperatures below 0°C orabove +40°C.Current ratings, see page 130.
  34. 34. FIXEDWIRINGANDMAINSCABLESLSZH 36Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.SINGLE CORE NON-ARMOURED MAINS CABLES LSZHPlain annealed stranded compacted circular copper conductor, single core,XLPE insulated, low smoke and zero halogen (LSZH) outer sheath. Black.600/1000 volts grade to BS6724. Flame propagation to BS4066 PT1 andIEC 60502-1. (Bunched cables to BS4066 PT3 and IEC 60502-3).CCC CONDUCTOR STRANDING WEIGHT OVERALL GLAND SINGLE TREFOILCODE SIZE (MM2) (MM) KG/KM DIAMETER SIZE CLEAT CLEAT(MM) (MM)6181B50 50 19/1.78 540 13.6 25 0.66181B70 70 19/2.14 750 15.6 25 0.76181B95 95 19/2.52 1010 17.5 25 0.76181B120 120 37/2.03 1250 19.2 32 0.86181B150 150 37/2.25 1530 21.3 32 0.96181B185 185 37/2.52 1900 23.4 32 1.0 2076181B240 240 61/2.25 2470 26.3 40 1.1 5026181B300 300 61/2.52 3080 29.0 40 1.2 5046181B400 400 61/2.52 3890 32.7 50S 1.4 5066181B500 500 61/3.20 4970 36.6 50S 1.6 5096181B630 630 127/2.52 6370 41.3 50 1.8 5116181B800 800 127/2.85 8150 46.3 63S 2.0 5156181B1000 1000 127/3.20 9860 53.00 63 TC9 519XLPE INSULATEDLOW SMOKE ZEROHALOGEN SINGLE CORENON-ARMOUREDMAINS CABLE(50MM2 TO 1000MM2)Temperature limits:-25 to +90°C.Bending radius:6 x overall diameter.Core identification:Brown inner/Black outer.Should not be installed attemperatures below 0°C orabove +40°C.Current ratings, see page 134.
  35. 35. 37SINGLE CORE ARMOURED MAINS CABLE LSZHStranded plain annealed compacted circular copper conductor, XLPE insulated,low smoke and zero halogen (LSZH) extruded bedding, aluminium wirearmour, low smoke and zero halogen (LSZH) outer sheath. Black. 600/1000volts grade to BS6724. Flame propagation to BS4066 PT1 and IEC 60502-1.(Bunched cables to BS4066 PT3 and IEC 60502-3).CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE TREFOILCODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT CLEAT(MM) (MM)6941AB50 50 19/1.78 1 800 17.7 20 0.86941AB70 70 19/2.14 1 940 19.6 25 0.96941AB95 95 19/2.52 1 1220 21.5 25 1.06941AB120 120 37/2.03 1 1490 23.2 25 1.26941AB150 150 37/2.25 1 1870 26.3 32 1.2 5026941AB185 185 37/2.52 1 2290 28.7 32 1.4 5046941AB240 240 61/2.25 1 2880 31.4 40 1.4 5056941AB300 300 61/2.52 1 3520 34.1 40 1.8 5076941AB400 400 61/2.85 1 4520 38.9 50S 1.8 5106941AB500 500 61/3.20 1 5680 42.8 50S 1.8 5126941AB630 630 127/2.52 1 7120 47.3 50 2.0 5156941AB800 800 127/2.85 1 9220 53.9 63S TC9 5196941AB1000 1000 127/3.20 1 11270 58.8 635 TC10 523FIXEDWIRINGANDMAINSCABLESLSZHPlease note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.XLPE INSULATEDLOW SMOKE ZEROHALOGEN SINGLE COREARMOURED MAINS CABLE(50MM2 TO 1000MM2)Temperature limits:-25 to +90°C.Bending radius:6 x overall diameter.Core identification:Brown inner/Black outer.Should not be installed attemperatures below 0°C orabove +40°C.Current ratings, see page 129.
  36. 36. 38SCREENEDFIXEDWIRINGANDMAINSCABLESTOBS8436Plain annealed stranded copper, XLPE insulated, tinned annealed strandedcopper earth wire, bonded aluminium tube applied longitudinally, low smokeand zero halogen (LSZH) outer sheath, to BS EN 50267-1:1998 and BS EN50268-2:2000, UV Stable. 600/1000v to BS8436, White.FIXEDWIRINGANDMAINSCABLESLSZHCCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND 1 HOLE GLANDCODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLIP REF(MM) (MM) REFFSX2X1WH 1.0 7/0.44 2 85 8.60 20S RCHL20 20SA2FSX3X1WH 1.0 7/0.44 3 105 9.40 20S RCHL20 20SA2FSX4X1WH 1.0 7/0.44 4 130 10.00 20 RCHL20 20A2FSX2X1/5WH 1.5 7/0.53 2 106 9.80 20 RCHL20 20A2FSX3X1/5WH 1.5 7/0.53 3 140 10.40 20 RCHL20 20A2FSX4X1/5WH 1.5 7/0.53 4 158 11.30 20 RCHL20 20A2FSX2X2/5WH 2.5 7/0.67 2 135 10.80 20 RCHL20 20A2FSX3X2/5WH 2.5 7/0.67 3 182 11.10 20 RCHL20 20A2FSX4X2/5WH 2.5 7/0.67 4 259 12.60 20 RCHL20 20A2FSX2X4WH 4 7/0.85 2 206 11.50 20 RCHL20 20A2FSX3X4WH 4 7/0.85 3 265 13.10 25 RCHL25 25A2FSX4X4WH 4 7/0.85 4 320 13.90 25 RCHL25 25A2FSX2X6WH 6 7/1.04 2 258 13.10 25 RCHL25 25A2FSX3X6WH 6 7/1.04 3 328 14.20 25 RCHL25 25A2FSX4X6WH 6 7/1.04 4 450 14.90 25 RCHL25 25A2MECHANICALLYPROTECTEDWIRING CABLEMinimum installation temperature:-10°C.Maximum continuous conductorsoperating temperature:+90°C.Core identification:2 core - Brown, Blue.3 core - Brown, Black, Grey.4 core - Brown, Black, Grey, Blue.*Solid cores available on request.Different sheath and core coloursavailable on request.10mm2and 16mm2availableon requestAlso available in 300/500 volt rating.Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
  37. 37. 39FIXED WIRING ANDMAINS CABLES11000VFIXEDWIRINGANDMAINSCABLES
  38. 38. 403 CORE MAINS CABLES PVC 11000VStranded plain annealed circular compacted copper conductors, XLPE insulated,semi-conducting tape insulated, each core copper tape screened, PVC bedding,galvanised steel wire armour, PVC outer sheath - Red. 6350/11000 volts gradeto BS6622 and IEC 502/1. Flame retardant to BS 4066 PT1 and IEC 60502-1.Red outer sheath can be prone to fading when exposed to U.V rays.CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE RAYCHEMCODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT TERMINATION(MM) (MM) REFERENCE11KV XLPE3X25RD 25 7/2/14 3 4400 48.8 50 2.0 EPKT 17A3XIH211KV XLPE3X35RD 35 19/1/53 3 4900 51.6 50 TC9 EPKT 17B3XIH211KV XLPE3X50RD 50 19/1/78 3 5600 54.6 63S TC9 EPKT 17B3XIH211KV XLPE3X70RD 70 19/2/14 3 6500 58.5 63S TC10 EPKT 17B3XIH211KV XLPE3X95RD 95 19/2/52 3 7800 62.6 63 TC10 EPKT 17C3XIH211KV XLPE3X120RD 120 37/2/03 3 8900 66.6 75S TC11 EPKT 17C3XIH211KV XLPE3X150RD 150 37/2/25 3 10000 68.8 75S TC11 EPKT 17C3XIH211KV XLPE3X185RD 185 37/2/52 3 11600 74.1 75 TC12 EPKT 17C3XIH211KV XLPE3X240RD 240 61/2/25 3 14800 81.2 90 TC14 EPKT 17C3XIH211KV XLPE3X300RD 300 61/2/52 3 17300 86.8 90 TC15 EPKT 1D3XIH211KV XLPE3X400RD 400 61/2/85 3 19300 93.0 TC15 EPKT 17D3XIH2SINGLE CORE ARMOURED MAINS CABLES PVC 11000VStranded plain annealed circular compacted copper conductors, XLPEinsulated, semi-conducting tape insulated, copper tape screen, PVC bedding,aluminium wire armour, PVC outer sheath - Red. 6350/11000 volts grade toBS6622 and IEC 502/1. Flame retardant to BS4066 PT1 and IEC 60502-1.Red outer sheath can be prone to fading when exposed to U.V rays.CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE TREFOIL RAYCHEMCODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT CLEAT TERMINATION(MM) (MM) REFERENCE10001 50 19/1.78 1 1200 28.0 32 1.2 503/504 EPKT 17B1XI10002 70 19/2.14 1 1500 29.9 32 1.2 504 EPKT 17B1XI10003 95 19/2.52 1 1600 31.7 32 1.4 506 EPKT 17C1XI10004 120 37/2.03 1 2100 33.3 40 1.4 506 EPKT 17C1XI10005 150 37/2.25 1 2500 35.7 40 1.6 508/509 EPKT 17C1XI10006 185 37/2.52 1 2900 37.5 40 1.6 508/509 EPKT 17C1XI10007 240 61/2.25 1 3600 40.1 50S 1.6 510/511 EPKT 17C1XI10008 300 61/2.52 1 4300 42.4 50S 1.8 512/513 EPKT 17D1XI10009 400 61/2.85 1 5200 45.8 50S 2.0 514 EPKT 17D1XI10010 500 61/3.20 1 6500 50.5 50 2.0 516/517 EPKT 17E1XI10011 630 127/2.52 1 8000 54.7 63S R9 519/521 EPKT 17E1XIPlease note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.Temperature limits:up to 90°C.Bending radius:12 x overall diameter.Core identification:Brown, Black, Grey tapes.Should not be installed attemperatures below 0°C orabove +60°C.Current ratings, see page 138.Temperature limits:up to 90°C.Bending radius:12 x overall diameter.Core identification:Brown.Should not be installed attemperatures below 0°C orabove +60°C.Current ratings, see page 137.FIXEDWIRINGANDMAINSCABLESSINGLE CORE(50MM2 TO 630MM2)AND 3 CORE(25MM2 TO 400MM2)XLPE INSULATED MEDIUMVOLTAGE MAINS CABLES11000 VOLT
  39. 39. FIXEDWIRINGANDMAINSCABLES41Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE RAYCHEMCODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT TERMINATION(MM) (MM) REFERENCE10115RD 95 19/2.52 3 5800 62.6 63 TC10 EPKT 17C3XIH210116RD 120 37/2.03 3 6400 66.6 75S TC11 EPKT 17C3XIH210117RD 150 37/2.25 3 7000 68.6 75S TC11 EPKT 17C3XIH210118RD 185 37/2.52 3 7800 74.1 75 TC12 EPKT 17C3XIH210119RD 240 61/2.25 3 9800 81.2 90 TC14 EPKT 17C3XIH210120RD 300 61/2.52 3 11000 86.8 90 TC15 EPKT 17D3XIH23 CORE MAINS CABLES PVC 11000VPlain stranded aluminium conductors, XLPE insulated, semi-conducting tapeinsulated, each core copper tape screened, PVC bedding (extruded), galvanisedsteel wire armour, PVC outer sheath. Red. 6350/11000 volts grade to BS6622and IEC 502/1. Flame propagation to BS4066 PT1 and IEC 60502-1. Red outersheath can be prone to fading when exposed to U.V rays.XLPE INSULATEDMEDIUM VOLTAGEMAINS CABLE11000 VOLT(95MM2 TO 300MM2)Temperature limits:up to 90°C.Bending radius:13 x overall diameter.Core identification:Brown, Black, Grey tapes.Should not be installed attemperatures below 0°C orabove +60°C.Current ratings see page 139.
  40. 40. FIXEDWIRINGANDMAINSCABLESPlease note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.42TRIPLEX CABLES 11000VSolid or stranded aluminium conductor, XLPE insulated, copper wire screen(35mm2). MDPE outer sheath. Red. 6350/11000 volts grade to BS7870.Red outer sheath can be prone to fading when exposed to U.V rays.CCC CONDUCTOR CONDUCTOR NOMINAL NO. OF WEIGHT DIAMETERCODE SIZE (MM2) TYPE CONDUCTOR CORES KG/KM IN TRIPLEXDIAMETER FORMATION11KVTRIP3X70AL 70 SOLID 9.30 3 2763 57.411KVTRIP3X70AL 70 STRANDED 9.80 3 2650 58.311KVTRIP3X95AL 95 SOLID 10.70 3 3055 60.811KVTRIP3X95AL 95 STRANDED 12.16 3 2901 57.8311KVTRIP3X185AL 185 SOLID 14.90 3 4095 70.511KVTRIP3X185AL 185 STRANDED 15.80 3 4060 72.511KVTRIP3X300AL 300.0 SOLID 19.00 3 5374 80.411KVTRIP3X300AL 300.0 STRANDED 20.50 3 5360 81.4Temperature limits:-15 to +90°C.Bending radius:15 x overall diameter.Current ratings, see page 135.Core identification:Brown, Black, Grey tapes.Should not be installed attemperatures below 0°C.3 CORE UTILITY CABLETRIPLEX FORMATION XLPEINSULATEDMEDIUM VOLTAGE CABLE11000 VOLT(70MM2 TO 300MM2)
  41. 41. FIXEDWIRINGANDMAINSCABLES43Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.PAPER INSULATED MAINS CABLES PVC 11000VCOPPER CONDUCTORPlain annealed copper conductors, paper insulated, paper belted, semi-conducting carbon paper tape bedding, lead sheathed, textile compoundbedding, galvanised steel wire armour, PVC outer sheath - Red. 6350/11000volts grade to BS6480/88. Flame propagation to BS4066 PT1 and IEC 60502-1.Red outer sheath can be prone to fading when exposed to U.V rays.CCC CONDUCTOR STRANDING No. OF WEIGHT OVERALL SINGLE RAYCHEMCODE SIZE (MM2) (MM) CORES KG/KM DIAMETER CLEAT TERMINATION(MM) REFERENCEPILC3X25RD 25 7/2.14 3 5230 43.6 1.8 EPKT 17A3MIH2PILC3X35RD 35 19/1.53 3 5890 42.3 2.0 EPKT 17B3MIH2PILC3X50RD 50 19/1.78 3 6620 45.6 2.0 EPKT 17B3MIH2PILC3X70RD 70 19/2.14 3 7820 49.7 2.0 EPKT 17B3MIH2PILC3X95RD 95 19/2.52 3 9240 53.3 TC9 EPKT 17C3MIH2PILC3X120RD 120 37/2.03 3 10400 56.2 TC9 EPKT 17C3MIH2PILC3X150RD 150 37/2.25 3 11770 59.2 TC10 EPKT 17C3MIH2PILC3X185RD 185 37/2.52 3 13550 62.8 TC10 EPKT 17C3MIH2PILC3X240RD 240 61/2.25 3 16390 67.8 TC11 EPKT 17C3MIH2PILC3X300RD 300 61/2.52 3 19870 73.6 TC12 EPKT 17D3MIH2PILC3X400RD 400 61/2.85 3 23700 79.4 TC14 EPKT 17D3MIH2ALUMINIUM CONDUCTORPlain aluminium stranded conductors, paper insulated, paper belted, semi-conducting carbon paper tape bedding, lead sheathed, textile compoundbedding, galvanised steel wire armour, PVC outer sheath - Red. 6350/11000volts grade to BS6480/88. Flame propagation to BS4066 PT1 and IEC 60502-1.Red outer sheath can be prone to fading when exposed to U.V rays.CCC CONDUCTOR STRANDING No. OF WEIGHT OVERALL SINGLE RAYCHEMCODE SIZE (MM2) (MM) CORES KG/KM DIAMETER CLEAT TERMINATION(MM) REFERENCE10100RD 95 19/2.52 3 7115 53.2 TC9 EPKT 17C3MIH210103RD 185 37/2.52 3 9521 63.5 TC11 EPKT 17C3MIH210105RD 300 61/2.52 3 13403 71.5 TC12 EPKT 17D3MIH2PAPER INSULATEDMEDIUM VOLTAGEMAINS CABLE11000 VOLT(25MM2 TO 400MM2)Temperature limits:up to 65°C.Bending radius:13 x overall diameter.Core identification:White printed numbers oninsulating papers.Should not be installed attemperatures below 0°C orabove +60°C.Temperature limits:up to 65°C.Bending radius:13 x overall diameter.Core identification:White printed numbers oninsulating papers.Should not be installed attemperatures below 0°C orabove +60°C.
  42. 42. FIXEDWIRINGANDMAINSCABLESPlease note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.44SINGLE CORE(50MM2 TO 630MM2)AND 3 CORE(25MM2 TO 400MM2)XLPE INSULATED LOWSMOKE ZERO HALOGENMEDIUM VOLTAGE MAINSCABLES 11000 VOLTSINGLE CORE ARMOURED MAINS CABLES LSZH 11000VStranded plain annealed compacted circular copper conductor, XLPE insulated,semi-conducting tape insulated, copper tape screen, low smoke and zero halogen(LSZH) bedding, aluminium wire armour, low smoke and zero halogen (LSZH)outer sheath - Red. 6350/11000 volts grade to BS7835. Flame retardant toBS4066 PT1 and IEC 60502-1. (Bunched cables to BS4066 PT3 and IEC 60502-3).Due to poor U.V resistant qualities, red outer sheath cables are not recomendedfor outdoor installation.CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE TREFOIL RAYCHEMCODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT CLEAT TERMINATION(MM) (MM) REFERENCE10050 50 19/1.78 1 1200 28.8 32 1.2 504 EPKT 17B1XI10051 70 19/2.14 1 1500 29.9 32 1.2 504 EPKT 17B1XI10052 95 19/2.52 1 1600 31.7 32 1.4 505 EPKT 17C1XI10053 120 37/2.03 1 2100 33.3 40 1.4 506 EPKT 17C1XI10054 150 37/2.25 1 2500 35.7 40 1.6 508 EPKT 17C1XI10055 185 37/2.52 1 2900 37.5 40 1.6 509 EPKT 17C1XI10056 240 61/2.25 1 3600 40.1 50S 1.6 511 EPKT 17C1XI10057 300 61/2.52 1 4300 42.4 50S 1.8 512 EPKT 17D1XI10058 400 61/2.85 1 5200 45.8 50S 2.0 514 EPKT 17D1XI10059 500 61X3.20 1 6500 50.5 50 2.0 517 EPKT 17E1XI10060 630 127X2.52 1 8000 54.7 63S TC9 520 EPKT 17E1XITemperature limits:up to 90°C.Bending radius:15 x overall diameter.Core identification:Brown.Should not be installed attemperatures below 0°C orabove +40°C.Current ratings, see page 137.3 CORE MAINS CABLES LSZH 11000VStranded plain annealed compacted circular copper conductors, XLPEinsulated, semi-conducting tape insulated, each core copper tape screened,low smoke and zero halogen (LSZH) bedding, galvanised steel wire armour,low smoke and zero halogen (LSZH) outer sheath - Red. 6350/11000 voltsgrade to BS7835. Flame retardant to BS4066 PT1 and IEC 60502-1.(Bunched cables to BS4066 PT3 and IEC 60502-3). Due to poor U.V resistantqualities red outer sheath cables are not recomended for outdoor installation.CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE RAYCHEMCODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT TERMINATION(MM) (MM) REFERENCE10302RD 35 19/1.53 3 4900 51.6 50 TC9 EPKT 17B3XIH210304RD 50 19/1.78 3 5600 54.6 63S TC9 EPKT 17B3XIH210306RD 70 19/2.14 3 6500 58.5 63S TC10 EPKT 17B3XIH210308RD 95 19/2.52 3 7800 62.6 63 TC10 EPKT 17C3XIH210310RD 120 37/2.03 3 8900 66.6 75S TC11 EPKT 17C3XIH210312RD 150 37/2.25 3 10000 68.8 75 TC11 EPKT 17C3XIH210314RD 185 37/2.52 3 11600 74.1 75 TC12 EPKT 17C3XIH210316RD 240 61/2.25 3 14800 81.2 90 TC14 EPKT 17C3XIH210318RD 300 61/2.52 3 17300 86.8 90 TC15 EPKT 17D3XIH210320RD 400 70/3.15 3 19300 90.9 TC15Temperature limits:up to 90°C.Bending radius:12 x overall diameter.Core identification:Brown, Black, Grey tapes.Should not be installed attemperatures below 0°C orabove +40°C.Current ratings, see page 138.
  43. 43. 45FIREPROOF CABLESFIREPROOFCABLES
  44. 44. 46FIREPROOF CABLES - MINERAL INSULATEDSolid plain annealed copper conductors, magnesium oxide insulated, solid coppersheath to BS6207, IEC 331 and BS 6387 CWZ. Available in the following options:(a) Light Duty = 500 volts grade (b) Outer sheath finishes, bare copper,Heavy Duty = 1000 volts grade PVC or LSZH(c) Outer sheath colours. Orange, Red,White or Black.SIZE BARE SHEATHED OVERALL OVERALL GLAND SINGLE HOLE CLIP NOMINALREF. KG/KM KG/KM DIAMETER DIAMETER FOR USE REFERENCE STD DRUMBARE SHEATHED WITH RPS BARE SHEATHED LTHS (MTS)(MM) (MM) SEALS2L1.0 105 126 5.1 6.4 20 20 26 5002L1.5 131 154 5.7 7.0 20 20 28 5002L2.5 180 206 6.6 7.9 20 26 32 5002L4.0 262 322 7.7 9.2 20 30 37 5003L1.0 136 159 5.8 7.1 20 22 28 5003L1.5 168 194 6.4 7.7 20 24 30 5003L2.5 222 272 7.3 8.8 20 28 34 5004L1.0 162 187 6.3 7.6 20 24 30 5004L1.5 203 231 7.0 8.3 20 28 34 5004L2.5 286 336 8.1 9.6 20 32 37 5007L1.5 310 351 8.4 9.9 25 32 40 3807L2.5 433 475 9.7 11.2 25 37 43 2851H6.0 173 213 6.4 7.7 20 24 34 6501H10 233 273 7.3 8.8 20 28 34 5101H16 321 361 8.3 9.8 20 32 37 4001H25 456 506 9.6 11.1 20 37 43 2751H35 600 650 10.7 12.2 20 40 47 2221H50 782 842 12.1 13.6 25 47 54 1701H70 1087 1147 13.7 15.2 25 54 59 1901H95 1450 1520 15.4 17.4 25 59 67 1551H120 1790 1870 16.8 18.8 32 63 75 1351H150 2130 2230 18.4 20.4 32 71 79 1101H240 3146 3312 23.3 26.1 40 88 101 67Temperature limits:PVC sheath -20 to +70°C.LSF sheath -20 to +80C.Bending radius: 6 x overall diameter.Should not be installed attemperatures below 0°C.Should not be installed attemperatures below 0°C.SIZE BARE SHEATHED OVERALL OVERALL GLAND SINGLE HOLE CLIP NOMINALREF. KG/KM KG/KM DIAMETER DIAMETER FOR USE REFERENCE STD DRUMBARE SHEATHED WITH RPS BARE SHEATHED LTHS (MTS)(MM) (MM) SEALS2H1.5 224 259 7.9 9.4 20 30 37 5002H2.5 275 314 8.7 10.2 20 34 40 5002H4.0 355 398 9.8 11.3 20 37 43 5002H6.0 433 483 10.9 12.4 20 43 47 5002H10 637 697 12.7 14.2 25 47 54 5002H16 888 968 14.7 16.2 25 54 63 1122H25 1175 1275 17.1 19.1 32 67 75 803H1.5 253 290 8.3 9.8 20 32 37 5003H2.5 324 365 9.3 10.8 20 37 43 5003H4.0 416 461 10.4 11.9 20 40 47 5003H6.0 530 590 11.5 13.0 25 43 51 1843H10 783 853 13.6 15.1 25 54 59 1303H16 1000 1080 15.6 17.1 25 59 71 1003H25 1442 1548 18.2 20.2 40 71 79 704H1.5 303 344 9.1 10.6 20 34 43 5004H2.5 385 430 10.1 11.6 20 40 47 5004H4.0 517 577 11.4 12.9 25 43 54 1954H6.0 658 718 12.7 14.2 25 47 54 1444H10 980 1050 14.8 16.3 25 54 63 1104H16 1300 1390 17.3 19.3 32 67 75 894H25 1800 1943 20.1 22.3 40 79 88 607H1.5 431 478 10.8 12.3 25 43 47 2457H2.5 561 614 12.1 13.6 25 47 54 19512H2.5 875 970 15.6 17.9 32 59 71 14819H1.5 989 1086 16.6 18.9 40 63 71 112FIREPROOFCABLESPlease note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.MINERALINSULATED CABLE(1.0MM2 TO 240MM2)
  45. 45. 47FIREPROOFCABLESPlease note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.STANDARD FIRE ALARM AND SECURITYWIRING CABLESPlain annealed copper conductor, silicon rubber insulated aluminium/polyestertape screen, tinned annealed copper earth wire, low smoke zero halogen (LSZH)outer sheath. Red, White, Orange or Black. Fire resistant to IEC 331 and BS6387.Flame retardant to BS5839-1:2003 and IEC 60332-3 CAT CWZ, BS7629-1 1997.CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND 1 HOLE GLANDCODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLIP REF REF(MM) (MM)FP2X1 1.0 1/1.13 2+E 90 7.5 20 32 251FP3X1 1.0 1/1.13 3+E 110 8.0 20 34 251FP4X1 1.0 1/1.13 4+E 135 8.8 20 40 251FP7X1 1.0 1/1.13 7+E 170 10.5 20 47 252FP12X1 1.0 1/1.13 12+E 270 13.7 25 59 254FP2X1/ 5 1.5 1/1.38 2+E 110 8.0 20 34 251FP3X1/ 5 1.5 1/1.38 3+E 130 8.4 20 40 251FP4X1/5 1.5 1/1.38 4+E 160 9.5 20 43 251FP7X1/5 1.5 1/1.38 7+E 230 11.3 20 51 252FP12X1/5 1.5 1/1.38 12+E 365 15.2 25 67 254FP19X1/5 1.5 1/1.38 19+E 540 17.8 25 79 254FP2X2/5 2.5 7/0.67 2+E 160 9.0 20 40 252FP3X2/5 2.5 7/0.67 3+E 200 10.5 20 47 252FP4X2/5 2.5 7/0.67 4+E 250 11.7 20 47 252FP7X2/5 2.5 7/0.67 7+E 285 13.7 20 54 252FP12X2/5 2.5 7/0.67 12+E 470 17.9 25 75 254FP19X2/5 2.5 7/0.67 19+E 720 21.4 32 88 255FP2X4 4.0 7/0.85 2+E 260 11.3 20 43 252FP3X4 4.0 7/0.85 3+E 315 12.1 25 54 254FP4X4 4.0 7/0.85 4+E 380 13.3 25 54 254FIRE RESISTANTFIRE ALARM &SECURITY CABLESTANDARD ANDENHANCED(1.0MM2 TO 4MM2)E = Bare earth conductor.Temperature limits:-10 to +80°C.Bending radius:6 x overall diameter.Core identification:2 core - Brown, Blue.3 core - Brown, Black, Grey.4 core - Brown, Black, Grey, Blue.7 core and above - White with Blacknumbers.Should not be installed attemperatures below 0°C orabove +40°C.E = Bare earth conductor.Temperature limits:-10 to +80°C.Bending radius:6 x overall diameter.Core identification:2 core - Brown, Blue.3 core - Brown, Black, Grey.4 core - Brown, Black, Grey, Blue.Should not be installed attemperatures below 0°C or above+40˚C.CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND 1 HOLE GLANDCODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLIP REF REF(MM) (MM)ENH2X1/5 1.5 1/1.38 2+E 110 8.0 20 34 251ENH3X1/5 1.5 1/1.38 3+E 130 8.4 20 40 251ENH4X1/5 1.5 1/1.38 4+E 160 9.5 20 43 251ENH2X2/5 2.5 7/0.67 2+E 160 9.0 20 40 252ENH3X2/5 2.5 7/0.67 3+E 200 10.5 20 47 252ENH4X2/5 2.5 7/0.67 4+E 250 11.7 20 47 252ENH2x4 4.0 7/0.85 2+E 260 11.3 20 43 252ENH3x4 4.0 7/0.85 3+E 315 12.1 25 54 254ENH4x4 4.0 7/0.85 4+E 380 13.3 25 54 254ENHANCED FIRE ALARM AND SECURITYWIRING CABLES
  46. 46. 48FIREPROOF MAINS AND CONTROL CABLES LSZHPlain annealed stranded copper conductor, mica fire resistant tape, XLPEinsulated, low smoke & zero halogen (LSZH) bedding, galvanised steel wirearmour, low smoke & zero halogen (LSZH) outer sheath. Black. 600/1000 volts.Fire resistant to IEC 331 & BS7846 / BS6387 & CWZ. Flame propagation toBS4066 PT1 and IEC 60332-3 (PT3 for bunched cables).FIRE RESISTANT POWERAND CONTROL CABLE(1.5MM2 TO 16MM2)FIREPROOFCABLESPlease note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.CCC CONDUCTOR STRANDING NO. OF WEIGHT OUTSIDE GLAND SINGLECODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT(MM) (MM)6942F1/5 1.5 7/0.53 2 295 12.00 20/16 0.56943F1/5 1.5 7/0.53 3 324 12.50 20/16 0.66944F1/5 1.5 7/0.53 4 367 13.30 20S 0.66947F1/5 1.5 7/0.53 7 463 15.30 20S 0.76940/12F1/5 1.5 7/0.53 12 791 20.00 25 0.86940/19F1/5 1.5 7/0.53 19 1030 22.90 25 1.06940/27F1/5 1.5 7/0.53 27 1534 27.90 32 1.26940/37F1/5 1.5 7/0.53 37 1849 30.70 32 1.46942F2/5 2.5 7/0.67 2 352 13.10 20S 0.66943F2/5 2.5 7/0.67 3 392 13.70 20S 0.66944F2/5 2.5 7/0.67 4 454 14.70 20S 0.66947F2/5 2.5 7/0.67 7 584 17.00 20 0.76940/12F2/5 2.5 7/0.67 12 1003 22.50 25 0.96940/19F2/5 2.5 7/0.67 19 1525 27.00 32 1.16940/27F2/5 2.5 7/0.67 27 1990 31.60 32 1.46940/37F2/5 2.5 7/0.67 37 2435 34.80 40 1.46942F4 4 7/0.85 2 424 14.10 20S 0.66943F4 4 7/0.85 3 478 14.80 20S 0.66944F4 4 7/0.85 4 556 16.00 20 0.76945F4 4 7/0.85 5 725 18.12 20 0.86947F4 4 7/0.85 7 852 19.50 20 0.86942F6 6 7/1.04 2 504 15.20 20 0.76943F6 6 7/1.04 3 573 16.00 20 0.76944F6 6 7/1.04 4 783 18.20 20 0.86945F6 6 7/1.04 5 865 19.65 20 0.86942F10 10 7/1.35 2 620 16.90 20 0.76943F10 10 7/1.35 3 868 18.50 20 0.86944F10 10 7/1.35 4 1029 20.00 25 0.86945F10 10 7/1.35 5 1222 22.64 25 0.96942F16 16 7/1.70 2 954 19.50 20 0.86943F16 16 7/1.70 3 1136 20.80 25 0.96944F16 16 7/1.70 4 1367 22.50 25 0.96945F16 16 7/1.70 5 1812 26.55 25 1.1Temperature limits:-25 to +90°C.Bending radius:8 x overall diameter.Core identification:2 core - Brown, Blue.3 core - Brown, Black, Grey.4 core - Brown, Black, Grey, Blue.5 core and above 4mm2and 6mm2-White with Black numbers.5 core - 10mm2and 16mm2- Brown,Black, Grey, Blue, Green/Yellow.Should not be installed attemperatures below 0°C orabove 40˚C.
  47. 47. 49Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.FIREPROOFCABLESFIREPROOF MAINS CABLES LSZHPlain annealed stranded copper conductor, mica fire resistant tape, XLPEinsulated, low smoke, zero halogen (LSZH) bedding, galvanised steel wirearmour, low smoke, zero halogen (LSZH) outer sheath. Black. 600/1000 voltsgrade. Fire resistant to BS6387/7846 & CWZ. Flame propagation to BS4066PT1 and IEC 60332-3 (PT3 for bunched cables).FIRE RESISTANTPOWER CABLE(25MM2 TO 400MM2)CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLECODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT(MM) (MM)FP 2X25 25 7/2.14 2 1460 24.50 25 1.0FP 3X25 25 7/2.14 3 1960 27.5 25 1.1FP 4X25 25 7/2.14 4 2320 32.0 32 1.4FP 5X25 25 7/2.14 5 2700 32.0 32 1.4FP 2X35 35 7/2.52 2 2100 28.0 25 1.2FP 3X35 35 7/2.52 3 2380 30.0 32 1.2FP 4X35 35 7/2.52 4 2870 32.0 32 1.4FP 2X50 50 19/1.78 2 1900 27.0 32 1.2FP 3X50 50 19/1.78 3 2770 30.5 32 1.4FP 4X50 50 19/1.78 4 3450 34.0 40 1.4FP 2X70 70 19/2.14 2 2450 30.0 40 1.2FP 3X70 70 19/2.14 3 3550 34.0 40 1.4FP 4X70 70 19/2.14 4 4800 39.5 50S 1.6FP 2X95 95 19/2.52 2 3400 34.0 40 1.4FP 3X95 95 19/2.52 3 4780 39.0 50S 1.6FP 4X95 95 19/2.52 4 5980 43.0 50S 1.8FP 2X120 120 37/2.03 2 4000 36.0 40 1.6FP 3X120 120 37/2.03 3 5720 42.0 50S 1.8FP 4X120 120 37/2.03 4 7690 48.5 50 2.0FP 2X150 150 37/2.25 2 4800 40.5 40 1.6FP 3X150 150 37/2.25 3 7100 46.5 50 2.0FP 4X150 150 37/2.25 4 8900 52.5 50 TC9FP 2X185 185 37/2.52 2 6200 44.0 50S 1.8FP 3X185 185 37/2.52 3 8490 51.0 50 TC9FP 4X185 185 37/2.52 4 10800 58.0 63S TC9FP 2X240 240 61/2.25 2 7600 50.0 50 2.0FP 3X240 240 61/2.25 3 10620 56.5 63S TC9FP 4X240 240 61/2.25 4 13600 64.5 63 TC11FP 2X300 300 61/2.52 2 9200 53.0 63S TC9FP 3X300 300 61/2.52 3 12740 61.5 63 TC10FP 4X300 300 61/2.52 4 16500 70.0 75S TC11FP 3X400 400 61/2.85 3 15810 68.0 75S TC11FP 4X400 400 61/2.85 4 21800 79.0 75 TC14Temperature limits:-25 to +90°C.Bending radius:8 x overall diameter.Core identification:2 core - Brown, Blue.3 core - Brown, Black, Grey.4 core - Brown, Black, Grey, Blue.5 core - Brown, Black, Grey, Blue,Green/Yellow.Should not be installed attemperatures below 0°C orabove 40˚C.
  48. 48. 51FLEXIBLE CABLESFLEXIBLECABLES
  49. 49. FLEXIBLECABLES 52Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.PVC INSULATED FLEXIBLE CORDS 218*Y - 318*YPlain annealed flexible copper conductors, PVC insulated, PVC outer sheath.Black or White. 300/500 volts grade to BS6500. (Harmonized code HO5VV-F).Flame propagation to BS4066 PT1 and IEC 332 PT1. (*HO3VV-F)CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLANDCODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE(MM) (MM)*2182Y/5 0.5 16/0.2 2 36 5.4 20/16*2182Y/75 0.75 24/0.2 2 45 5.8 20/16*2183Y/5 0.5 16/0.2 3 44 5.6 20/16*2183Y/75 0.75 24/0.2 3 55 6.1 20/163182Y/5 0.5 16/0.2 2 52 6.3 20/163183Y/5 0.5 16/0.2 3 54 6.3 20/163182Y/75 0.75 24/0.20 2 59 6.8 20/163183Y/75 0.75 24/0.20 3 70 7.2 20/163184Y/75 0.75 24/0.20 4 85 7.7 20/163185Y/75 0.75 24/0.20 5 110 8.5 20S3182Y1 1.0 24/0.20 2 69 7.2 20/163183Y1 1.0 32/0.20 3 82 7.6 20/163184Y1 1.0 32/0.20 4 105 8.5 20S3185Y1 1.0 32/0.20 5 130 9.1 20S3182Y1/5 1.5 30/0.25 2 95 8.2 20/163183Y1/5 1.5 30/0.25 3 120 8.9 20S3184Y1/5 1.5 30/0.25 4 150 10.0 20S3185Y1/5 1.5 30/0.25 5 180 11.0 203182Y2/5 2.5 50/0.25 2 145 9.9 20S3183Y2/5 2.5 50/0.25 3 180 10.8 20S3184Y2/5 2.5 50/0.25 4 220 11.3 203185Y2/5 2.5 50/0.25 5 265 12.8 20PVC INSULATEDFLEXIBLE CORDSTYPE 218*Y & 318*Y(0.5MM2 TO 2.5MM2)Temperature limits:Fixed - -5 to +60°C.Flexing - +5 to +60°C.Bending radius:Fixed 2 x overall diameter.Flexing 6 x overall diameter.Core identification:2 core - Blue, Brown.3 core - Blue, Brown, Green/Yellow.4 core - Blue, Brown, Black,Green/Yellow or Brown, Black, Grey,Green/Yellow.5 core - Blue, Brown, Black, Grey,Green/Yellow.As per Cenelec HD 308 four core isavailable in two alternative coreidentification methods.Should not be installed attemperatures below 0°C.
  50. 50. FLEXIBLECABLES53Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.PVC INSULATED FLEXIBLE CORDS 309*YPlain annealed flexible copper conductors heat resisting PVC outer sheath. White300/500 volts grade to BS6141. Flame propagation to BS4066 PT1 and IEC 332 PT1.CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLANDCODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE(MM) (MM)3092Y/5 0.5 16/0.20 2 46 6.3 20/163093Y/5 0.5 16/0.20 3 66 6.5 20/163094Y/5 0.5 16/0.20 4 70 7.2 20/163092Y/75 0.75 24/0.20 2 56 6.8 20S3093Y/75 0.75 24/0.20 3 68 7.2 20S3094Y/75 0.75 24/0.20 4 85 7.7 20S3095Y/75 0.75 24/0.20 5 104 8.5 20S3092Y1 1.0 32/0.20 2 65 7.2 20S3093Y1 1.0 32/0.20 3 77 7.6 20S3094Y1 1.0 32/0.20 4 100 8.5 20S3092Y1/5 1.5 30/0.25 2 80 8.2 20S3093Y1/5 1.5 30/0.25 3 100 8.9 20S3094Y1/5 1.5 30/0.25 4 130 10.0 203092Y2/5 2.5 50/0.25 2 135 10.0 20S3093Y2/5 2.5 50/0.25 3 150 10.8 203094Y2/5 2.5 50/0.25 4 195 11.8 20Temperature limits:Fixed - -5 to +90°C.Flexing - +5 to +90°C.Bending radius:Fixed - 2 x overall diameter.Flexing - 6 x overall diameter.Current ratings, see page 129.Core identification:2 core - Blue, Brown.3 core - Blue, Brown, Green/Yellow.4 core - Blue, Brown, Black,Green/Yellow.Should not be installed attemperatures below 0°C.ARTIC GRADE FLEXIBLE CORDSPlain annealed flexible copper conductors, low temperature PVC insulation, lowtemperature PVC outer sheath. Blue or Yellow. 300/500 volts grade to BS7919 table44 and BS6500. Flame propagation to BS4066 PTI and IEC332PTI.CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLANDCODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE(MM) (MM)3183AG1/5 1.5 30/0.25 3 90 8.20 20S3184AG1/5 1.5 30/0.25 4 130 9.55 20S3183AG2/5 2.5 50/0.25 3 180 10.15 20S3184AG2/5 2.5 50/0.25 4 220 11.30 203183AG4 4 56/0.30 3 240 11.40 20Temperature limits:Flexing - 40 to + 70°CBending radius:6 x overall diameter.Current ratings, see page 129.Core identification:3 core - Blue, Brown, Green/Yellow.4 core - Blue, Brown, Black,Green/Yellow.PVC INSULATEDFLEXIBLE CORDSTYPE 309*Y(0.5MM2 TO 2.5MM2)AND ARTIC GRADE(1.5MM2 TO 4MM2)
  51. 51. FLEXIBLECABLES 54Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.ZERO HALOGEN FLEXIBLE CORDS (HO5 ZIZI-F)Plain annealed copper conductors, Low smoke and zero halogen (LSZH) insulated,low smoke and zero halogen (LSZH) outer sheath. Black or white. 300/500 voltsgrade (Generally to BS6500) flame propagation to BS4066 PT1 and IEC 332 PT1Harmonised code HO5 ZIZI-F.CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLANDCODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE(MM) (MM)3182B/75 0.75 24/0.2 2 59 6.8 20/163183B/75 0.75 24/0.2 3 70 7.2 20/163184B/75 0.75 24/0.2 4 85 7.7 20/163185B/75 0.75 24/0.2 5 110 8.5 20S3182B1 1.00 32/0.2 2 69 7.2 20/163183B1 1.00 32/0.2 3 82 7.6 20/163184B1 1.00 32/0.2 4 105 8.5 20S3185B1 1.0 32/0.2 5 130 9.1 20S3182B1/5 1.5 30/0.25 2 95 8.2 20/163183B1/5 1.5 30/0.25 3 120 8.9 20S3184B1/5 1.5 30/0.25 4 150 10 20S3185B1/5 1.5 30/0.25 5 180 11 203182B2/5 2.5 50/0.25 2 145 9.9 20S3183B2/5 2.5 50/0.25 3 180 10.8 20S3184B2/5 1.5 50/0.25 4 220 11.3 203185B2/5 2.5 50/0.25 5 265 12.8 20LOW SMOKEZERO HALOGEN FLEXIBLECORDS TYPE 318*B(0.75MM2 TO 2.5MM2)Temperature limits:-15 to +70°cBending radius:Fixed 4x overall diameterFlexing 6x overall diameterCore identification:2 core - Brown, Blue.3 core - Blue, Brown, Green/Yellow.4 core - Blue, Brown, Black,Green/Yellow or Brown, Black, Grey,Green/Yellow.5 core - Blue, Brown, Black, Grey,Green/Yellow.As per Cenelec HD 308, four core isavailable in two alternative coreidentification methods.Should not be installed attemperatures below 0°C.

×