TS_Mould_Humidity_MASTER_01_2012   25.11.2011   14:04   Seite 1                                                           ...
TS_Mould_Humidity_MASTER_01_2012            07.12.2011      07:37     Seite 2     Thermographic mould and humidity measure...
Upcoming SlideShare
Loading in...5
×

Testo thermography of mold and humidity

108

Published on

Published in: Technology
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
108
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
4
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Testo thermography of mold and humidity

  1. 1. TS_Mould_Humidity_MASTER_01_2012 25.11.2011 14:04 Seite 1 We measure it. TESTOsolutions Thermographic mould and humidity measurement So that you can detect the humidity before your customer can spot the mould. Damp interiors and mould wont stand a chance. Thermal imagers from Testo make it easy for you to keep an eye on all potential sources of risk. How? Simple: Testo thermal imagers calculate the humidity value of each measuring point using the externally determined ambient temperature and air humidity as well as the measured sur- face temperature. And on your display you are immediately able to detect what is invisible to the naked eye.
  2. 2. TS_Mould_Humidity_MASTER_01_2012 07.12.2011 07:37 Seite 2 Thermographic mould and humidity measurement We measure it. The application Humidity-related risks in buildings. Humidity in building interiors often leads to wide-ranging problems. Structural defects and inappropriate user behaviour can result in the formation of mould. Testo thermal imagers can be used in many areas: Locating thermal bridges Detecting air leaks Detecting cracks in the masonry Gas leak detection and location Energy consultancy It is particularly important for moist areas on walls and ceilings to be made visible. This is because the earlier you detect the risk of mould developing, with its associated risks to health and equipment, the sooner you can do something about it. The solution Thermographic mould and humidity measurement with Testo: simple, contactless and efficient. Scientific studies have shown that humidity values of approximately 80 and the thermal imaging camera will take care of the rest and calculate %RH are required for mould to grow. Xerophilic fungi even grow from the relative surface humidity value for each measuring point. In approximately 65 %RH. Testo thermal imagers reveal sites at risk of addition, an external wireless humidity sensor can be connected to the mould, such as ceilings, walls or corners, directly on the camera testo 882, testo 885 and testo 890 models and can be used to display: points at risk are displayed in red, points not at risk appear transmit the ambient parameters to the thermal imaging camera. green. One glance is all it takes for you to be assured that you are in the There is no need to input the readings manually. Thus, the continuous clear. No need to spend time on elaborate and complex calculations of data transmission makes calculating humidity values even easier and humidity values or make a written note of them. Simply input the more reliable. ambient temperature and air humidity into the thermal imaging camera, More info. Tel: 01420 544433 0981 8474/Q/01.2012 Email: info@testo.co.uk Web: www.testolimited.com

×