Your SlideShare is downloading. ×
Testo 270 Oil Tester Info Sheet 02
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×
Saving this for later? Get the SlideShare app to save on your phone or tablet. Read anywhere, anytime – even offline.
Text the download link to your phone
Standard text messaging rates apply

Testo 270 Oil Tester Info Sheet 02

180

Published on

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
180
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
1
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. Correctcalibrationandadjustment.Important tips on the calibration and adjustment of the testo 270Preparation ! °CUse only the original Testo The sensor must be completely Before calibration / adjustment,reference oil! clean. warm the reference oil to approximately 50 °C in hot water.Calibration 1. 2. 3. 4.1. Immediately after switching on, during the display Remove reference oil Immerse sensor in Begin adjustment pro- As soon as LEDs light test, press and hold [ /Hold] and [▲] for approx. 3 from hot water. reference oil, LEDs cedure with [ /Hold]. up in green, measure- sec. The oil may not light up in orange. • LEDs light up in red. ment is ended.2. °C or F appears in display. come into contact Compare value with • Move sensor in oil. with the water! label value from refe-3. Switch through the menu with [ /Hold], until CAL and on or OFF appear. rence oil bottle: Select with [▲] or [▼] on. Deviation 1%4. Confirm with[ /Hold]. • Adjustment necessary OIL and CAL appear in display. Deviation /= 1% • Finish calibration without adjustmentAdjustment Finishing calibration without adjustment/Adjustment after calibration Exit calibration menu • Set to the TPM value on the reference oil bottle with [▲] or [▼] • Confirm with [ /Hold]. • Keep [ /Hold] pressed to leave • rSt and on or OFF appear. configuration mode. • With [▲] or [▼], select OFF. • Afterwards you get back to the • Confirm with [ /Hold]. measurement mode. • The set value is taken over, instrument swit- • You can now take further measurements ches to measurement mode. or switch off the instrument.You can download this training card from www.testo.com/trainingcard-calibration-oil-testerMore information on testo 270 at www.testo.com/oil-tester

×