• Share
  • Email
  • Embed
  • Like
  • Save
  • Private Content
Testo 270 Oil Tester Info Sheet 01
 

Testo 270 Oil Tester Info Sheet 01

on

  • 278 views

 

Statistics

Views

Total Views
278
Views on SlideShare
278
Embed Views
0

Actions

Likes
0
Downloads
0
Comments
0

0 Embeds 0

No embeds

Accessibility

Categories

Upload Details

Uploaded via as Adobe PDF

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

    Testo 270 Oil Tester Info Sheet 01 Testo 270 Oil Tester Info Sheet 01 Document Transcript

    • The right way to measure.Important tips on the operation and maintenance of the testo 270Preparation < cm .1 > in m ! ! °CPlastic compo- Do not touch Remove fried Wait until Observe minimum distance Measure in hot oilnents may not the hot probe. goods before bubbles no of 1 cm to metal objects. (min. 40 °C, max. 190 °C).come into Danger of measuring. longer rise tocontact with the burning! the surfacecooking oil. (approx. 5 min.).Measurement MAX MINSwitch on the instrument Immerse sensor in hot oil. 1. Move sensor in oil (adjustment time approx. 20 sec.) Note down[ /Hold] Watch out for the min/max Auto Hold activated: the recorded marks! • Auto Hold in the display indicates the end of the measu- measurement rement. If set, an audible signal additionally sounds. values. • Final value is fixed. Auto Hold deactivated: • When the temperature on the display no longer changes, a stable TPM value has been reached. • To fix measurement values: briefly press [ /Hold] < 1 sec. 2. To return to the measurement mode: briefly press [ /Hold] < 1 sec.Care and maintenance Cleaning Accuracy test Your specific starting value: ___%TPMClean instrument with mild detergent. Rinse The TopSafe and For a fast and easy instrument test, For an accurate instrument testsensor under running water and dry carefully hand strap can we recommend you to carry out and/or correction, or if measure-with a soft paper towel. be conveniently an accuracy test according to the ment values are implausible, cleaned in the instruction manual. we recommend calibration and dishwasher. If the oil type or the supplier is adjustment in Testo reference oil. changed, a new reference value must be determined.You can download this training card from: www.testo.com/trainingcard-oil-testerFor more information on the testo 270, visit: www.testo.com/oil-tester