0981 8114/msp/Si/A/02.2011   Subject to change without notice.
Committing to the futureEverything under control:With testo SaverisTM, measurement data areunder control everywhere.
Unlimited data monitoring.    Whether stationary or mobile.    The data monitoring system testo Saveris measures the tempe...
If measurement parameters are documented during transport, the driver receives all necessary information and alarmsfrom a ...
Overview of application areas    Monitoring of processes in the pharmaceutical industry    In the pharmaceutical industry,...
Monitoring of the building climate                                                       When monitoring the building clim...
Overview of application areas    Monitoring the foodstuff cooling chain    Compliance with predefined temperature values i...
Monitoring in production, transport and storage inindustryIn industry, a number of quality data must be recorded andmonito...
testo Saveris™ system overview    Data monitoring for uninterrupted checks    testo SaverisTM wireless probe              ...
testo SaverisTM Base                                                 testo SaverisTM softwareThe base is the heart of test...
testo Saveris™ software                                                                                                   ...
Small Business Edition (SBE), Professional (PROF) and CFR versionNow more flexible with Professional software             ...
testo Saveris™ Base     The base is the heart of testo Saveris and can save 40,000 readings per     measurement channel in...
testo Saveris™ Cockpit UnitThe Saveris Cockpit Unit displays all measurement values to the driverwithout interruption duri...
testo Saveris™ components: Router, Converter and Extender     The radio link can be improved or lengthened in poor structu...
testo Saveris™: AccessoriesPower supply                                                               Order no.           ...
testo Saveris™ components: Radio probe     Probe versions with internal and external temperature sensors and with humidity...
testo Saveris™ components: Radio probe                                                                                    ...
testo Saveris™ components: Ethernet probes     The existing LAN infrastructure can be used through the Ethernet probe. Thi...
testo Saveris™ components: Ethernet probes                                                                                ...
testo Saveris™ accessories: External temperature probes       Pt     Plug-in probes                              Illustrat...
testo Saveris™ accessories: External temperature and humidity probes NTC     Plug-in probes                              I...
testo Saveris™ set     All components can be assembled individually by you.     However, you also have the option of order...
ServiceTesto is a manufacturer of measuring instruments and measuring systemswith a global presence, with 27 international...
Upcoming SlideShare
Loading in …5
×

Testo - Saveris Wireless Temperature and Humidity Monitoring System

4,169 views
4,061 views

Published on

The data monitoring system testo Saveris measures the temperature and humidity values of
sensitive goods and products in the environment, in processes and during transport. The
easy-to-use measurement system delivers safety and savings in time and costs thanks to
automated measurement data recording. In stationary operation, the transfer of the
measurement data takes place via wireless and/or Ethernet connection to a base station. This
documents and monitors all measurement data. If limit values are exceeded, a whole range of
different alarm options, such as SMS/e-mail alarm or alarm relay is available. Remote alarms
can even be given when the system is not connected to a running PC.

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
4,169
On SlideShare
0
From Embeds
0
Number of Embeds
1
Actions
Shares
0
Downloads
15
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Testo - Saveris Wireless Temperature and Humidity Monitoring System

  1. 1. 0981 8114/msp/Si/A/02.2011 Subject to change without notice.
  2. 2. Committing to the futureEverything under control:With testo SaverisTM, measurement data areunder control everywhere.
  3. 3. Unlimited data monitoring. Whether stationary or mobile. The data monitoring system testo Saveris measures the temperature and humidity values of sensitive goods and products in the environment, in processes and during transport. The easy-to-use measurement system delivers safety and savings in time and costs thanks to automated measurement data recording. In stationary operation, the transfer of the measurement data takes place via wireless and/or Ethernet connection to a base station. This documents and monitors all measurement data. If limit values are exceeded, a whole range of different alarm options, such as SMS/e-mail alarm or alarm relay is available. Remote alarms can even be given when the system is not connected to a running PC.2
  4. 4. If measurement parameters are documented during transport, the driver receives all necessary information and alarmsfrom a Cockpit Unit in the driver’s cabin. Documentation and monitoring takes place via wireless probes, the time-consuming installation of wired sensors in the truck is unnecessary. At the same time, the possibility of printing outmeasurement values at the handover of goods, using an infrared printer, also exists.All data recorded, whether stationary or on the road, are centrally stored in a software. At the same time, Saverisallows the comprehensive analysis and evaluation of all recorded measurement data.With testo Saveris, all measurement data are under control, whether stationary or on the road. 3
  5. 5. Overview of application areas Monitoring of processes in the pharmaceutical industry In the pharmaceutical industry, high demands are placed on the recording and monitoring of quality parameters. Constant documentation during the production, storage and transportation of temperature-sensitive products such as medicines, blood products or cell cultures has long been considered an absolute “must”. testo Saveris automates the central documentation of measurement data as well as the safe monitoring of refrigerated and deep-freeze rooms, incubators and climate cabinets. At the same time, the system allows the uninterrupted recording of measurement data, even during the transport of temperature or humidity-critical products such as medicaments or vaccines. This means testo Saveris offers the optimum control of production and storage, via transport, up to delivery. The comprehensive alarm management allows fast alarming if limit values are violated. Thanks to a combination of wireless and/or Ethernet probes, the system is optimum for many different applications in the pharmaceutical industry. It goes without saying that the data monitoring system testo Saveris meets the requirements of 21 CFR Part 11.4
  6. 6. Monitoring of the building climate When monitoring the building climate, stable ambient conditions are especially necessary in museums and archives in order to protect sensitive and expensive objects. During transportation, valuable goods must be constantly monitored. testo Saveris automates the central recording of all climate data, stationary as well as during transport. By issuing alarms when limit values are exceeded, testo Saveris protects valuable inventory from undesired temperature or humidity influences at all times. The radio probe can be flexibly attached to locations without the effort of routing cables.Monitoring of processes in research and development, laboratories and hospitalsResearch and development areas as well as laboratories and hospitals are responsible for the recording ofambient and process data in order to monitor sensitive products or machines. However, the monitoring oftemperature and humidity-critical goods during transport is also crucial for a high standard of quality. testoSaveris carries out the central documentation of the measurement series, for stationary as well as fortransport applications.testo Saveris thus guarantees the simple and secure monitoring of climate and process data in airconditioning chambers, refrigerators, drying chambers, test benches or blood banks. If critical values areto be monitored during transport, testo Saveris offers the optimum solution. 5
  7. 7. Overview of application areas Monitoring the foodstuff cooling chain Compliance with predefined temperature values is a decisive factor for quality in food production and is important for complying with legal hygiene standards. However, the decisive factor is the uninterrupted monitoring of the cold chain during production, storage, and above all, during transport. Only this uninterrupted monitoring provides a final guarantee that the quality and freshness of the products can be certified. testo Saveris automates not only the monitoring of the ambient and production temperatures during production and storage, but also of defined temperature limit values during transport. The installation of wireless probes in delivery vehicles makes the complicated wiring of the driver’s cabin unnecessary. Alarms are issued whenever the limit values are exceeded. The measurement data from stationary and transport applications are saved centrally in a database and are accessible at any time. All measurement values are under control! testo Saveris conforms to the EN 12830 standard.6
  8. 8. Monitoring in production, transport and storage inindustryIn industry, a number of quality data must be recorded andmonitored in the production, storage and transport of products.testo Saveris automates the documentation of these data andalarms when limit values are exceeded. Products and processesare thus guaranteed at a high level of quality.testo Saveris is ideal for use in the monitoring and documentationof ambient and temperature data in production areas, storerooms,refrigerators and climate cabinets. At the same time, testo Saverisallows the uninterrupted recording of measurement parametersduring the transport of sensitive products. The most variedapplications, stationary as well as in transport, are optimallycovered by testo Saveris radio probes and/or Ethernet probes. 7
  9. 9. testo Saveris™ system overview Data monitoring for uninterrupted checks testo SaverisTM wireless probe testo SaverisTM router testo SaverisTM converter Probe versions with internal and exter- The radio link can be improved or Through the connection of a converter nal temperature and humidity sensors lengthened in poor structural conditi- to an Ethernet jack, the signal of a radio allow the adaptation to every applica- ons by using a router. Several routers probe can be converted into an Ether- tion. The radio probes are available can of course be used in the testo Sa- net signal. This combines the flexible with or without a display as an option. veris system. At the same time, the connection of the radio probe with the Current measurement data, the bat- serial switching of up to 3 routers use of the existing Ethernet even over tery status and the quality of the radio V 2.0 offers highest flexibility in the wi- long transmission paths. link are shown on the display. reless range. testo SaverisTM testo SaverisTM converter V 2.0 router V 2.0 Ethernet testo SaverisTM wireless probe testo SaverisTM analog coupler (Ethernet) Humidity trans- testo SaverisTM mitters analog coupler (wireless) testo Saveris radio probe testo Saveris Ethernet probe testo SaverisTM analog coupler Humidity transmitters testo 6651/6681/6351/6381 The two versions of the analog coupler (wireless / Ethernet) allow the The two versions of the analog coupler (wireless / Ethernet) allow the inclusion of other measurement parameters into the testo Saveris mo- inclusion of other measurement parameters into the testo Saveris mo- nitoring system, by integrating all measurement transmitters with nitoring system, by integrating all measurement transmitters with standarized current/voltage interfaces, e. g. 4 to 20 mA or 0 to 10 V. standarized current/voltage interfaces, e. g. 4 to 20 mA or 0 to 10 V.8
  10. 10. testo SaverisTM Base testo SaverisTM softwareThe base is the heart of testo Saveris The testo Saveris software offers simple operation and anand can save 40,000 readings per intuitive user interface. The Saveris software is available inmeasurement channel independently three different versions: as the basic version SBE (Smallof the PC. This corresponds to around Business Edition), the PROF (Professional) software versionone year of memory capacity at a with diverse additional options, or as the CFR version. Themeasuring rate of 15 minutes. The CFR software fulfils the requirements of the FDA’s 21 CFRsystem data and alarms are visible via Part 11 and is thus validatable.the display of the Saveris base. USB or EthernetEthernet testo SaverisTM Software testo Saver- isTMBase Ethernet testo SaverisTM Control unit testo SaverisTM Ethernet probe Control unittesto SaverisTM Ethernet probe testo SaverisTM extender testo SaverisTM Cockpit UnitIn addition to the radio probes, probes By connecting a Saveris Extender, the The Saveris Cockpit Unit displays allcan be used that are directly con- wireless signal of a transport probe is measurement values to the driver un-nected to the Ethernet. The existing converted into an Ethernet signal. The interruptedly during transport. If limitLAN infrastructure can be used data transfer from wireless probe to values are violated, the driver is imme-through this. This allows the data Extender takes place automatically diately warned. Alternatively, the com-transfer from the probe to the base, when sufficient wireless connection is plete data recording can be printedeven over long distances. present. out at the handover site of the goods using the Testo printer on the Cockpit Unit. 9
  11. 11. testo Saveris™ software 1 Installation made easy · Connect Saveris base to mains. The probes can now be logged on at the base: They are switched on in series and automatically identified by the base. · The Saveris base is connected to the PC via USB or Ethernet. The software is installed on the PC with help from the installation wizard. · The system is ready for configuration: Probe name, limit values, measuring cycles and alarms can be adapted to the individual measuring tasks. 2 Clear and always up-to-date · The measurement data can always be shown as a graphic or table. · Various probes can be compiled into groups. Logical units by measurement task are thus formed. · The measurement data view over days, weeks or months is freely definable. The integrated calendar offers practical assistance here. 3 Automated documentation Daily reportCold storage house zone: Hourly mean values on 03.08.2007Time °C freezer 1 %RH cold room 1 °C refrigerator °C drinks °C freezer 2 °C freezer 3 °C freezer 4 · Form and time of the reporting are predefined once. · The creation and saving of reports as a PDF file now takes place automatically in accordance with the set conditions. The files are therefore ready to be printed at any time.Total maximum valueTotal mean valueTotal minimum value 10
  12. 12. Small Business Edition (SBE), Professional (PROF) and CFR versionNow more flexible with Professional software 4The PROF (Professional) software version offers interesting additionalfunctions beyond the attractive standard functions of the basic version SBE,e.g.: 21 °C 48 %RH· Client-server concept: The measurement data can be monitored by various PCs integrated into the network.· Photographs of machines or rooms can be saved as a picture. The respective measurement values are shown directly at the position of the probe in the room or at the machine in these. The link between the 26 °C 38 %RH location and the measurement value is thus very easily visualized (fig. 4).· A comprehensive alarm management offers the option of alarming more 41 °C 22 %RH than two people at the same time or in succession. Depending on the day of the week or the time, it is possible to choose whether the alarm is given as an e-mail or an SMS.· Tour planning with calendar management allows a clear presentation of planned and completed transports.Validatable CFR software 5The CFR software fulfils the requirements of the FDA’s 21 CFRPart 11 and is thus validatable.Overview of software features SBE PROF CFRDiagrams / tables / Alarm overview / PDF reports • • •Calendar management • • •Presentation of probe groups • • •Alarm dispatch (e-mail, SMS, relay) • • •Comprehensive alarm management in stationary operation • •Automated update of measurement data (“Online mode”) in stationary operation • •Measurement data on background photo of measruement sites • •Integration in network (client-server) • •Tour planning with calendar management • •Allocation of access rights for stationary and mobile probe groups • •Search function for tours • • SBE software, incl. USB connectingConfiguration of print text • • cable base-PCDiagrams / tables with identification of start and stop of tour • •21 CFR Part 11 compliant (validatable) • Order no. 0572 0180Electronic signature •Audit trail • PROF software, incl. USB con-Allocation of access rights on 3 user levels • necting cable base-PC Order no. 0572 0181Overview of application areas Saveris software SBE PROF CFR CFR software, incl. Ethernet con- necting cable base-PCStationary operation • • •Mobile operation • • Order no. 0572 0182Stationary and mobile operation • • 11
  13. 13. testo Saveris™ Base The base is the heart of testo Saveris and can save 40,000 readings per measurement channel independently of the PC. The system data and alarms are visible via the display of the Saveris base. Display for showing alarms and system data Large data memory Issue of alarms via LED/relay SMS alarm (optional) Emergency battery integrated Up to 150 probes can be connected Connection option via USB or Ethernet Technical data Ordering data Memory 40,000 values per channel (total max. 18.000.000 values) Saveris base, radio frequency 868 MHz Saveris base, radio frequency 868 MHz, Dimensions 225 x 150 x 49 mm GSM module integrated (for SMS 868 MHz 868 MHz alarm) Weight approx. 1510 g Protection class IP42 Order no. Order no. Housing material Die-cast zinc/plastic 0572 0220 0572 0221 Radio frequency 868 MHz No mains units or antennas with magnetic base are contained in this ordering data. Power supply (absolutely 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw necessary) terminals, power consumption 4 W Rech. batt. Li-ion battery (for data back-up and for emergency SMS with fai- lure of the power supply) Oper. temp. -10 to +50 °C Storage temp. -40 to +60 °C Display graphical display, 4 control keys Interfaces USB, radio, Ethernet Connectable radio probe max. 15 probes can be directly connected via radio interface, max. 150 total via radio / Router / Converter / Ethernet / Exten- Note on the radio frequencies der max. 450 channels 868 MHz: EU countries and certain other countries (e.g. CH, CN, Alarm relay max. 1 A, max. 30 W, max. 60/25 V DC/AC, NC or NO contact NOR) GSM module 850/900/1800/1900 MHz Country list at www.testo.com/saveris not valid for Japan and South Korea Set up Table base and wall bracket included12
  14. 14. testo Saveris™ Cockpit UnitThe Saveris Cockpit Unit displays all measurement values to the driverwithout interruption during transport. If limit values are violated, thedriver is immediately warned. Alternatively, the complete data recordingcan be printed out at the handover site of the goods using an infraredprinter on the Cockpit Unit. Display for showing alarms and system data Large data memory Alarms via LED Printout of readings using infrared printer Emergency battery integrated Up to 8 probes can be connected Wireless, USB and infrared interfaces Technical data Ordering dataMemory max. 20.000 readings Saveris Cockpit UnitDimensions approx. 150 x 90x 40 mm 868 MHzWeight approx. 210 gProtection class IP40 Order no.Housing material Plastic 0572 0222Radio frequency 868 MHzPower supply (absolutely Mini USB cable incl. adapter 12/24 V DCnecessary)Oper. temp. -30 to +65 °CStorage temp. -40 to +85 °CDisplay graphical display, 4 control keysInterfaces Wireless, USB, infraredConnectable radio probe up to 2 zones of 4 wireless probes each. max. 32 channelsAttachment Sucker pad with telescope function 13
  15. 15. testo Saveris™ components: Router, Converter and Extender The radio link can be improved or lengthened in poor structural conditions by using a router. Several routers can of course be used in the testo Saveris system. At the same time, the serial switching of up to 3 routers V 2.0 offers highest flexibility in the wireless range. Through the connection of a converter to an Ethernet jack, the signal of a radio probe can be converted into an Ethernet signal. This combines the flexible connection of the radio probe with the use of the existing Ethernet even over long transmission paths. By connecting an Extender, the wireless signal of a transport probe is converted into an Ethernet signal. The data transfer from probe to Extender takes place automatically when sufficient wireless connection is present. Radio Radio Radio Radio Radio Ethernet Ethernet Ethernet Saveris Router V 1.0 Saveris Router V 2.0 Saveris Converter V 1.0 Saveris Converter V 2.0 Saveris Extender Use · for Saveris Base Firmware · for Saveris Base · for Saveris Base · for all Saveris Base Firmware · for Saveris Base Version V 1.X Firmware Firmware Version V 1.X versions Firmware Version V 2.X · for wireless probes with Version V 2.X Firmware Version V 2.X Dimensions approx. 85 x 100 x 38 mm Weight approx. 180 g approx. 190 g Power supply 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw ter- 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals, PoE, minals, power consumption power consumption Oper. temp. -20 to +50 °C Storage temp. -40 to +60 °C Housing material Plastic Protection class IP54 Interfaces Radio Radio, Ethernet Connectable radio probe max. 5 max. 15 max. 100 Router cascading No Yes - - - Wall holder included Versions Saveris router, V 1.0,868 MHz, Saveris router, V 2.0,868 MHz, Saveris Cverter V 1.0, Saveris Cverter V 2.0, Saveris Extender 868 MHz, radio transmission medium radio transmission medium 868 MHz, converts the radio 868 MHz, converts the radio converts the radio transmis- transmission medium to transmission medium to sion medium to Ethernet 868 MHz Ethernet Ethernet Order no. Order no. Order no. Order no. Order no. 0572 0119 0572 0219 0572 0118 0572 0218 0572 0217 No mains units are contained in this ordering data.14
  16. 16. testo Saveris™: AccessoriesPower supply Order no. 1Spare batteries for radio probes (4 x AA alkali manganese mignon 0515 0414batteries)Spare batteries for radio probes for operation below -10 °C (4 x 0515 0572Energizer L91 Photo lithium)International mains unit 100-240 V AC / 6.3 V DC; for mains ope- 0554 1096ration or battery charging in intrumentMains unit (top-hat rail mounting) 90 to 264 VAC / 24 VDC (2.5 A) 0554 1749Mains unit (desktop) 110 to 240 VAC / 24 VDC (350 mA) 0554 1748Miscellaneous Order no. Magnetic foot aerial (dual band)1 Magnetic foot aerial (dual band) with 3 m cable, for Base with 0554 0524 GSM module (not suitable for USA, Canada, Chile, Argentina, Mexico) Antenna with magnetic foot (quad band) for Base with 0554 0525 2 GSM module Alarm module (optical + audible), connectable to Base alarm2 relay, Ø 70 x 164 mm, 24 V AC/DC / 320 mA, permanent 0572 9999 light: rot, permanent tone: buzzer approx. 2.4 kHz (mains unit ID-No. 0699 6111/1 0554 1749 required) Programming adapter (from Mini DIN to USB) for Ether- 0440 6723 net probes, Converters and Extenders (necessary if no DHCP server available)3 Saveris protective housing for protection from high-pressure 0572 0200 cleaning and impact, IP 69 K suitable for wireless probes T1 / T1D / T2 / T2D Alarm module (visual + acoustic), can be Testo fast printer with wireless infrared interface, 1 roll of ther- connected to base alarm relay4 0554 0549 mal paper and 4 mignon batteries for printing out readings out on Saveris Cockpit Unit 3Software Order no.SBE software, incl. USB connecting cable base-PC 0572 0180PROF software, incl. USB connecting cable base-PC 0572 0181CFR software, incl. Ethernet connecting cable base-PC 0572 0182Saveris adjustment software incl. connection cable to wireless 0572 0183and Ethernet probesCalibration certificates Order no.ISO temperature calibration certificate; temperature probe; cali- Saveris protective housingbration points -8 °C, 0 °C, +40 °C; per channel/instrument (suit- 0520 0171able for Saveris T1/T2)ISO temperature calibration certificate; temperature probe; cali-bration points -18 °C, 0 °C, +60 °C; per channel/instrument (suit- 0520 0151 4able for Saveris T1/T2)DAkkS temperature calibration certificate*; temperature probe;calibration points -20 °C, 0 °C, +60 °C; per channel/instrument 0520 0261(suitable for Saveris T1/T2)ISO humidity calibration certificate; humidity probe; calibrationpoints 11.3 % RH and 75.3 % RH at +25 °C/+77 °F; per chan- 0520 0076nel/instrumentDAkkS humidity calibration certificate*; humidity probe; calibrationpoints 11.3 % RH and 75.3 % RH at +25 °C/+77 °F; per chan- 0520 0246nel/instrument*Successor organization of the DKD Testo fast printer 15
  17. 17. testo Saveris™ components: Radio probe Probe versions with internal and external temperature sensors and with humidity sensors allow the adaptation to every application. The radio probes are available with or without a display as an option. Current measurement data, the battery status and the quality of the radio link are shown on the dis- play. °C / °F Pt NTC NTC TC TC 100 internal internal external external external 81 mm 81 mm 81 mm 81 mm Radio Saveris T1 Saveris T2 Saveris T3 Saveris Pt Radio probe with internal NTC Radio probe with external probe con- 2-channel radio probe with 2 external TC Radio probe with 1 external Pt100 probe nection and internal NTC, door contact probe connections (TC characteristics can connection be selected) Probe type NTC NTC Internal sensor Measuring range -35 to +50 °C -35 to +50 °C Accuracy ± 0.4 °C (-25 to +50 °C) ± 0.4 °C (-25 to +50 °C) ±0.8 °C (remaining meas. range) ±0.8 °C (remaining meas. range) Resolution 0.1 °C 0.1 °C Probe type NTC TC Type K TC Type J Pt100 Measuring range -50 to +150 °C -195 to +1350 °C -100 to +750 °C -200 to +600 °C (instrument) TC type T TC type S External probe -200 to +400 °C 0 to +1760 °C Accuracy (instrument) ± 0.2 °C (-25 to +70 °C) ±0.5 °C or 0.5% of reading) at 25 °C ±0.4 °C (remaining meas. ± 0.1 °C (0 to +60 °C) range) ±0.2 °C (-100 to +200 °C) ±0.5 °C (remaining meas. range) Resolution (instrument) 0.1 °C 0.1 °C / TC Type S 1 °C 0.01 °C Connection NTC via Mini DIN socket, 2 TCs via TC socket, max. diffe- 1 Pt100 via mini-DIN socket Door contact connection cable rence in potential 2 V included in delivery (1.80 m) Dimensions (housing): 80 x 85 x 38 mm Weight approx. 240 g Battery life Battery life 3 years at +25 °C; 3 years with Energizer L91 Photo lithium batteries for freezer applications (Type: 4 x AA) Housing material Plastic Protection class IP68 IP54 IP68 Radio frequency 868 MHz / 2.4 GHz Meas. cycle Standard 15 min, can be set from 1 min up to 24 h Memory 6.000 readings Conformity with standards DIN EN 12830 Oper. temp. -35 to +50 °C -20 to +50 °C Storage temp. -40 to +55 °C Display (optional) 2-line LCD; 7 segments with symbols Transmission distance approx. 300 m free field at a frequency of 868 MHz, approx. 100 m free field at a frequency of 2.4 GHz Wall holder included Versions Version without display Saveris T1 Saveris T2 Saveris T3 Saveris Pt Order no. Order no. Order no. Order no. 868 MHz 0572 1210 * 0572 1211 * 0572 9212 * 0572 7211 * Version with Saveris T1 D Saveris T2 D Saveris T3 D Saveris Pt D display Order no. Order no. Order no. Order no. 0572 1220 * 0572 1221 * 0572 9222 * 0572 7221 * The AA alkali manganese mignon batteries (0515 0414) are contained in this ordering data (excepting analog coupler). Saveris probes are delivered with a calibration protocol of the works adjustment data. Calibration certificates must be ordered separately. * The Saveris Converter V 2.0 (order no. 0572 0218) is required for integration of Saveris wireless probes into systems with Base firmware V 1.X For more information please contact your Testo partner.16
  18. 18. testo Saveris™ components: Radio probe °C / °F and %RH mA and V % RH NTC % RH NTC % RH NTC mA V external internal external internal Radio Saveris H2D Saveris H3 Saveris H4D Saveris U1 Humidity radio probe Humidity radio probe Radio probe with 1 external humidity Radio probe with current/voltage input probe connection Probe type NTC Humidity sen- 1 channel: Current/voltage input sor Measuring range -20 to +50 °C 0 - 100 %RH 2-wire: 4 ... 20 mA 4-wire: 0/4 ... 20 mA, 0 to 1/5/10 V, load: max. 160 W atInternal sensor 24 V DC Accuracy ± 0.5 °C ±3 % RH Current ±0.03 mA / 0.75 µA Voltage 0 to 1 V ±1.5 mV/39 µV Voltage 0 to 5 V ±7.5 mV / 0.17 mV Voltage 0 to 10 V ±15 mV / 0,34 mV ±0.02% of m.v./K deviating from nominal temperature 22 °C Resolution 0.1 °C 0.1 °C / 0.1 °Ctd Probe type NTC Humidity sensor NTC Humidity sensor Meas. range (instrument) -20 to +50 °C 0 to +100 %RH ** -20 to +70 0 to +100 %RH **External probe Accuracy (instrument) ± 0.5 °C to 90 %RH: ±2 % RH ± 0.2 °C see probes > 90 %RH: ±3 % RH Resolution (instrument) 0.1 °C 0,1%/0.1 °Ctd 0.1 °C 0,1%/0.1 °CtdConnection fixed stump probe 1 x external humidity probe 2/4-wire current/voltage input Mini DIN socket Service interface Mini DIN for adjustmentDimensions (housing): 85 x 100 x 38 mm 80 x 85 x 38 mm approx. 85 x 100 x 38 mmWeight approx. 256 g approx. 245 g approx. 240 gBattery life Batery life 3 years at +25 °C; 3 years with Energizer L91 Photo lithium batteries for freezer applications Supply: Mains unit 6.3 V DC, 2 to(Type: 4 x AA) 30 V DC max. 25 V ACHousing material PlasticProtection class IP54 IP42 IP54Radio frequency 868 MHz / 2.4 GHzMeas. cycle Standard 15 min, can be set from 1 min up to 24 hMemory 6.000 readingsOper. temp. -20 to +50 °CStorage temp. -40 to +55 °CDisplay (optional) 2-line LCD; 7 segments with symbols (no display)Transmission distance approx. 300 m free field at a frequency of 868 MHz, approx. 100 m free field at a frequency of 2.4 GHzWall holder included Versions Version without Saveris H3 Saveris U1 display Order no. Order no.868 MHz 0572 6210 * 0572 3210 * Version with Saveris H2D Saveris H3 D Saveris H4D display Order no. Order no. Order no. 0572 6222 * 0572 6220 * 0572 6224 * The AA alkali manganese mignon batteries (0515 0414) are contained in this ordering data (excepting analog coupler). Saveris probes are delivered with a calibration protocol of the works adjustment data. Calibration certificates must be ordered separately.* The Saveris Converter V 2.0 (order no. 0572 0218) is required for integration of Saveris wireless probes into systems with Base firmware V 1.X For more information please contact your Testo partner.** not for continuous high-humidity applications 17
  19. 19. testo Saveris™ components: Ethernet probes The existing LAN infrastructure can be used through the Ethernet probe. This allows the data transfer from the probe to the base, even over long dis- tances. Ethernet probes have a display. °C TC Pt NTC 100 external external external Ethernet Saveris T1E Saveris T4 E Saveris Pt E Ethernet probe with external NTC probe 4-channel Ethernet probe with 4 external TC probe Ethernet probe with external Pt100 probe connection connections connection Probe type NTC TC Type K TC Type J Pt100 Measuring range -50 to +150 °C -195 to +1350 °C -100 to +750 °C -200 to +600 °C (instrument) TC type T TC type S External probe -200 to +400 °C 0 to +1760 °C Accuracy (instrument) ± 0.2 °C (-25 to +70 °C) ±0.5 °C or 0.5% of reading) at 25 °C ±0.4 °C (remaining meas. ± 0.1 °C (0 to +60 °C) range) ±0.2 °C (-100 to +200 °C) ±0.5 °C (remaining meas. range) Resolution (instrument) 0.1 °C 0.1 °C / TC Type S 1 °C 0.01 °C Connection 1 NTC via mini-DIN socket 4 TCs via TC socket 1 Pt100 via mini-DIN socket max. potential difference 50 V Mini-DIN service interface for adjustment is accessible externally Dimensions (housing): approx. 85 x 100 x 38 mm Weight approx. 220 g Supply 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals, PoE Buffer battery Li-ion Housing material Plastic Protection class IP54 Meas. cycle 2 sec to 24 h Memory 6000 readings Oper. temp. -20 to +60 °C Storage temp. -40 to +60 °C Power consumption PoE Class 0 (typically ≤ 3 W) Display (optional) 2-line LCD; 7 segments with symbols Wall holder included Versions Saveris T1E Saveris T4 E Saveris Pt E With display With display With display Order no. Order no. Order no. 0572 1191 0572 9194 0572 7191 Saveris probes are delivered with a calibration protocol of the works adjustment data. Calibration certificates must be ordered separately. Mains units are not included in delivery.18
  20. 20. testo Saveris™ components: Ethernet probes °C / °F and %RH mA and V % RH NTC % RH NTC % RH NTC mA V external external external internal Ethernet Saveris H1E Saveris H2 E Saveris H4E Saveris U1E Humidity Ethernet probe 1% Humidity Ethernet probe 2 % Ethernet probe with external humidity Radio probe with current/voltage input probe connection Probe type 1 channel: Current/voltage input Measuring range 2-wire: 4 ... 20 mA 4-wire: 0/4 ... 20 mA, 0 to Internal sensor 1/5/10V, load: max. 160 W at 24 V DC Accuracy Current ±0.03 mA / 0.75 µA Voltage 0 to 1 V ±1.5 mV / 39 µV Voltage 0 to 5 V ±7.5 mV / 0.17 mV Voltage 0 to 10 V ±15 mV / 0.34 mV ±0.02% of m.v./K deviating from nominal temperature 22 °C Probe type NTC Humidity sensor NTC Humidity sensor NTC Humidity sensor Measuring range -20 to +70 0 to 100 %RH* -20 to +70 0 to 100 %RH* -20 to +70 0 to 100 %RH* (instrument) External probe Accuracy (instrument) ± 0.2 °C (0 to +30 °C) to 90 %RH: ±(1 %RH ± 0.2 °C (0 to +30 °C) to 90 %RH: ±(1 %RH ± 0.2 °C (-20 to see external probes ±0.5 °C (remaining +0.7 % of m.v.) at +25 ±0.5 °C (remaining +0.7 % of m.v.) at +25 +70 °C) meas. range) °C meas. range) °C > 90 %RH: ±(1.4 %RH > 90 %RH: ±(1.4 %RH +0.7 % of m.v.) at +25 +0.7 % of m.v.) at +25 °C °C Resolution (instrument) 0.1 °C 0.1% / 0.1 °Ctd 0.1 °C 0.1% / 0.1 °Ctd 0.1 °C 0.1%/0.1 °Ctd Connection 1 x external humidity probe Mini DIN so- 1 x 2/4-wire current/voltage input cket Mini-DIN service interface for adjustment is accessible externally Dimensions (housing): approx. 85 x 100 x 38 mm Weight approx. 230 g approx. 254 g approx. 240 g Supply 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals, PoE Buffer battery Li-ion Housing material Plastic Protection class IP54 Meas. cycle 2 sec to 24 h Memory 6.000 readings Oper. temp. -20 to +60 °C Storage temp. -40 to +60 °C Power consumption PoE Class 0 (typically ≤ 3 W) Display (optional) 2-line LCD; 7 segments with symbols no display Wall holder included Versions Saveris H1 E Saveris H2 E Saveris H4E Saveris U1E With display With display With display no display Order no. Order no. Order no. Order no. 0572 6191 0572 6192 0572 6194 0572 3190 Sintered caps for Saveris H1 E, H2 E and H2D Ethernet probes Order no. Metal protective cap, Ø 12 mm for humidity probes, for measurement at flow velocities les than 10 m/s 0554 0755 Stainless steel sintered filter, pore size 100 µm, sensor protection for dusty atmospheres or higher flow velocities, for measurement 0554 0647 in high flow velocities or contaminated air Cap with wire fabric filter, Ø 12 mm 0554 0757 Sintered PTFE filter, Ø 12 mm, for aggressive media, high-humidity applications (long-term measurements), high flow velocities) 0554 0756 Testo saline pots for monitoring and humidity adjustment of humidity probes, 11.3% RH and 75.3% RH, incl. adapter for 0554 0660 humidity probe, quick check or calibration of humidity probe Saveris probes are delivered with a calibration protocol of the works adjustment data. Calibration certificates must be ordered separately. Mains units are not included in delivery. *not for continuous high-humidity applications 19
  21. 21. testo Saveris™ accessories: External temperature probes Pt Plug-in probes Illustration Meas. range Accuracy t99 Order no. 100 Robust, Pt100 stainless steel food probe (IP65) 125 mm 15 mm -50 to +400 °C Class A (-50 to +300 °C), 10 0609 2272 Class B (rem. meas. range) sec Ø 4 mm Ø 3 mm Connection: Fixed cable extended Penetration probe Pt100 with ribbon cable, -50 to +180 °C Class A 10 0572 7001 60 mm 30 mm cable length 2 m, IP 54 sec Ø 5 mm Ø 3.6 mm Robust, watertight Pt100 immersion/penetra- 114 mm 50 mm -50 to +400 °C Class A (-50 to +300 °C), 12 0609 1273 tion probe Class B (rem. meas. range) sec Ø 5 mm Ø 3.7 mm Fixed cable extended Connection cable for unlimited Pt100 stationary probes with screw terminals (4-wire technology) 0554 0213 TC Plug-in probes Illustration Meas. range Accuracy t99 Order no. Stationary probe with stainless steel sheath, TC 40 mm -50 to +205 °C Class 2* 20 0628 7533 Type K Ø 6 mm sec Connection: Fixed cable 1.9 m Robust air probe, TC Type K 115 mm -60 to +400 °C Class 2* 25 0602 1793 Ø 4 mm sec Connection: Fixed cable 1.2 m Penetration probe TC with ribbon cable, Type K, -40 to + 220 °C Class 1 7 0572 9001 60 mm 30 mm sec cable length 2 m, IP 54 Ø 5 mm Ø 3.6 mm Magnetic probe, adhesive power approx. 20 N, with 35 mm -50 to +170 °C Class 2* 150 0602 4792 magnets, for measurements on metal surfaces, TC Ø 20 mm sec type K Fixed cable extended Magnetic probe, adhesive power approx. 10 N, with 75 mm 0602 4892 -50 to +400 °C Class 2* magnets, for higher temperatures, for measurements Ø 21 mm on metal surfaces, TC type K Connection: Fixed cable 1.6 m Pipe wrap probe for pipe diameters from 5 - 65 mm, -60 to +130 °C Class 2* 5 0602 4592 with exchangeable measuring head, measuring sec range briefly up to +280°C, TC type K Connection: Fixed cable 1.2 m 395 mm Pipe wrap probe with Velcro tape, for measuring -50 to +120 °C Class 1* 90 0628 0020 20 mm temperatures on pipes with diameters up to max. sec 120 mm, Tmax +120°C, TC type K Connection: Fixed cable 1.5 m Thermocouple with TC plug, flexible, length 800 800 mm -50 to +400 °C Class 2* 5 0602 0644 mm, fibreglass, TC Type K Ø 1.5 mm sec Thermocouple with TC plug, flexible, length 1500 1500 mm -50 to +400 °C Class 2* 5 0602 0645 mm, fibreglass, TC Type K Ø 1.5 mm sec Thermocouple with TC plug, flexible, length 1500 1500 mm -50 to +250 °C Class 2* 5 0602 0646 mm, fibreglass, TC Type K Ø 1.5 mm sec Immersion measuring tip, flexible, TC type K 500 mm -200 to +1000 Class 1* 5 0602 5792 Ø 1.5 mm °C sec Immersion measuring tip, flexible, for measure- -200 to Class 1* 4 0602 5693 ments in air/exhaust gases (not suitable for mea- 1000 mm +1300 °C sec surements in smelters Ø 3 mm The specified accuracy class of the Saveris radio and Ethernet probe is achieved using these exter- *Acc. to norm EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 nal probes. to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).20
  22. 22. testo Saveris™ accessories: External temperature and humidity probes NTC Plug-in probes Illustration Meas. range Probe accuracy t99 Order no. Stump probe, IP 54 35 mm -20 to +70 ± 0.2 °C (-20 to +40 °C) 15 0628 7510 Ø 3 mm ±0.4 °C (+40.1 to +70 °C) sec Stationary probe with aluminium sleeve, IP 65 40 mm -30 to +90 °C ± 0.2 °C (0 to +70 °C) 190 0628 7503* Ø 6 mm ±0.5 °C (remaining meas. range)sec Connection: Fixed cable; Cable length: 2.4 m Accurate immersion/penetration probe, cable 40 mm -35 to +80 °C ± 0.2 °C (-25 to +74.9 °C) 5 0610 1725*length 6 m, IP 67 Ø 3 mm Ø 3 mm ±0.4 °C (remaining meas. range)sec Connection: Fixed cable; Cable length: 6 m Accurate immersion/penetration probe, cable 40 mm -35 to +80 °C ± 0.2 °C (-25 to +74.9 °C) 5 0628 0006*length 1,5 m, IP 67 Ø 3 mm Ø 3 mm ±0.4 °C (remaining meas. range)sec Connection: Fixed cable; Cable length: 1.5 m Penetration probe NTC with ribbon cable, 60 mm 30 mm -40 to +125 °C ±0.5 % of reading (+100 to +125 °C) 8 0572 1001cable length 2 m, IP 54 ±0.2 °C (-25 to +80 °C) sec ±0.4 °C (remaining meas. range) Ø 5 mm Ø 3.6 mmWall surface temperature probe, e. g. for proof of -50 to +80 °C ± 0.2 °C (0 to +70 °C) 20 0628 7507structural damage in buildings sec Connection: Fixed cable; Cable length: 3 m Stainless steel NTC food probe (IP65) with PU 125 mm 15 mm 0613 2211* -50 to +150 °C2) ±0.5 % of reading (+100 to +150 °C) 8line Ø 4 mm Ø 3 mm ±0.2 °C (-25 to +74.9 °C) sec ±0.4 °C (remaining meas. range) Connection: Fixed cable; Cable length: 1.6 m Watertight NTC immersion/penetration probe 115 mm 50 mm -50 to +150 °C ±0.5 % of reading (+100 to +150 °C) 10 0613 1212 Ø 5 mm ±0.2 °C (-25 to +74.9 °C) sec Ø 4 mm ±0.4 °C (remaining meas. range) Connection: Fixed cable extendedPipe wrap probe with Velcro tape for pipe diame- 300 mm -50 to +70 ± 0.2 °C (-25 to +70 °C) 0613 4611 30 mmters of up to max. 75 mm, Tmax. +75°C, NTC ±0.4 °C (-50 to -25.1 °C) Connection: Fixed cable; Cable length: 1.5 m% RH Plug-in probes Illustration Meas. range Accuracy Order no. Humidity / temperature probe 12 mm -20 to +70 °C, ±0.3 °C, ±2 %RH (2 to 98 0572 6172 Ø 12 mm 0 to +100 %RH %RH) Humidity / temperature probe 4 mm Ø 4 mm 0 to +40 °C, 0 to ±0.3 °C, ±2 %RH (2 to 98 0572 6174 +100 %RH %RH) The specified accuracy class of the Saveris radio and Ethernet probe is achieved using these *Probe tested according to EN 12830 for suitability for the areas of transport and storageexternal probes. 2) Long-term measuring range to +125 °C, briefly to +150 °C or +140 °C (2 minutes) 21
  23. 23. testo Saveris™ set All components can be assembled individually by you. However, you also have the option of ordering a testo Saveris set. This can be supplemented with individual components as required. Set: 868 MHz, consisting of base 0572 0220, 3 NTC radio probes without display 0572 1210, mains unit for base 0554 1096 and SBE software 0572 0180 incl. USB cable Set / 868 MHz Order no. 0572 0210 Adjustment All testo Saveris probes are of course adjusted in the factory, as confirmed by an adjustment report. You can perform further calibrations or adjustments either yourself on site, via a service provider or in a calibration laboratory. The separate Saveris adjustment software is available for this. After successful adjustment, the current adjustment data is stored in the probe. At the same time, the adjustment software and the Saveris software accept this data so that the adjustment histories are available. Radio and Ethernet probes are connected to a cable via the service interface for adjustment. If you do not wish to perform your own calibration, Testo is available as a service provider. Saveris adjustment software incl. connection cable to wireless and Ethernet probes Order no. 0572 018322
  24. 24. ServiceTesto is a manufacturer of measuring instruments and measuring systemswith a global presence, with 27 international subsidiaries andrepresentatives in numerous countries. Naturally, testo also offers you on-site service. For questions regarding testo SaverisTM, from installation toretrofitting further system components, please refer to your competentcontact in your country.You can find an overview of the nearest service location atwww.testo.com 23

×