Demonstration Thermography reportCompany    Testo Ltd                        Tester:           Newman Lane                ...
Demonstration Thermography reportFile:                                                   Date:                            ...
Demonstration Thermography reportFile:                                                  Date:                             ...
Demonstration Thermography reportFile:                                                  Date:                             ...
Demonstration Thermography reportFile:                                                  Date:                             ...
Demonstration Thermography reportFile:                                                 Date:                              ...
Demonstration Thermography reportFile:                                                  Date:                             ...
Demonstration Thermography reportFile:                                                  Date:                             ...
Demonstration Thermography reportFile:                                               Date:                                ...
Demonstration Thermography reportFile:                                        Date:                               Measurin...
Demonstration Thermography reportProfile line:Remarks:Thermal and Digital Images of Office Floor, taken with the Testo 880...
Demonstration Thermography reportFile:                                                 Date:                              ...
Demonstration Thermography reportFile:                                               Date:                                ...
Demonstration Thermography reportFile:                                                  Date:                             ...
Demonstration Thermography reportAuto Hot / Cold Spot Indicator has been applied, which automatically highlights the Hotte...
Upcoming SlideShare
Loading in …5
×

Demo report 25 std hvac applications

305 views
233 views

Published on

Published in: Business, Technology
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
305
On SlideShare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
14
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Demo report 25 std hvac applications

  1. 1. Demonstration Thermography reportCompany Testo Ltd Tester: Newman Lane Andy McGrath - Testo Alton, GU34 2QJ Phone: 01420 544433 E-Mail: info@testo.co.ukDevice Testo 880-3, 875-2 & 881-3 Serial No.: 1434423, 01729604 & 01710401 Lens: 32 degree, Wide Angle LensCustomer Testo Ltd Measuring Site: Testo Thermal Imaging Demonstration Thermography Report Cameras Various Applications for Testo Thermal Demo Report Imaging cameras in HVAC. Measuring Date: VariousTask Demonstration Thermography Report to highlight the capabilities of the Testo Thermal Imaging cameras for various applications associated to HVAC. Page 1/15
  2. 2. Demonstration Thermography reportFile: Date: Measuring Time:IV_00518.BMT 14/01/2009 12:57:02Picture parameters:Emissivity: 0.95Refl. temp. [°C]: 20.0Picture markings:Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] RemarksMeasure point 1 20.7 0.95 20.0 Spot Temp 1 to indicate temperature variation across the floorMeasure point 2 30.0 0.95 20.0 Spot Temp 2 to indicate temperature variation across the floorMeasure point 3 30.9 0.95 20.0 Spot Temp 3 to indicate temperature variation across the floorMeasure point 4 23.3 0.95 20.0 Spot Temp 4 to indicate temperature variation across the floorProfile line:Remarks:Thermal Survey, specifically in a Utility Room for Trace and Access application.Thermal and Digital imagesof Floor area taken as part of an investigation for possible leaks. Thermal image highlights temperaturevariation across the floor, this is therefore an indication of the location of the heating pipework under thefloor. Page 2/15
  3. 3. Demonstration Thermography reportFile: Date: Measuring Time:IV_00662.BMT 09/04/2009 08:27:40Picture parameters:Emissivity: 0.95Refl. temp. [°C]: 20.0Picture markings:Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] RemarksMeasure point 1 19.7 0.95 20.0 -Measure point 2 22.5 0.95 20.0 -Measure point 3 19.2 0.95 20.0 -Profile line:Remarks:Thermal Survey at a Domestic Property.Thermal and Digital images of Floor area taken as part of aninvestigation for possible leaks. Thermal image highlights temperature variation across the floor, this istherefore an indication of the location of the heating pipework under the floor.Spot temperature markershighlight temperature difference across floor where heating pipework is located. Page 3/15
  4. 4. Demonstration Thermography reportFile: Date: Measuring Time:IV_00663.BMT 09/04/2009 08:28:15Picture parameters:Emissivity: 0.95Refl. temp. [°C]: 20.0Picture markings:Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] RemarksMeasure point 1 20.9 0.95 20.0 -Measure point 2 23.5 0.95 20.0 -Measure point 3 20.6 0.95 20.0 -Profile line:Remarks:Thermal Survey at a Domestic Property.Thermal and Digital images of Floor area taken as part of aninvestigation for possible leaks. Thermal image highlights temperature variation across the floor, this istherefore an indication of the location of the heating pipework under the floor.Spot temperature markershighlight temperature difference across floor where heating pipework is located. Page 4/15
  5. 5. Demonstration Thermography reportFile: Date: Measuring Time:IV_00383.BMT 08/12/2008 13:26:37Picture parameters:Emissivity: 0.95Refl. temp. [°C]: 20.0Picture markings:Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] RemarksMeasure point 1 17.6 0.95 20.0 Spot Temp 1 on Tiled Floor adjacent to radiatorMeasure point 2 16.9 0.95 20.0 Spot Temp 2 on Tiled Floor adjacent to end of Skirting boardMeasure point 3 16.6 0.95 20.0 Spot Temp 3 on Tiled Floor next to glazed sectionMeasure point 4 14.3 0.95 20.0 Spot Temp 4 on Tiled floor area away from where the hot water pipes are locatedMeasure point 5 14.2 0.95 20.0 Spot Temp 5 on Tiled floor area away from where the hot water pipes are locatedProfile line:Remarks:Demonstration Thermal survey conducted with Testo 880 series Thermal Imaging camera. Conducted inGlazed walkway between Lounge and Kitchen extension.The homeowner is complaining of possible water leak under the tiled floor. At the time that this Thermal andDigital image were taken, the heat pattern effect from the hot water pipes under the floor were able to beseen in the the Thermal image, travelling the length of the walkway but no anomaly is apparent at this stage.Spot Temperatures have been added to the image to indicate the temperatures along the path of the pipes.A temperature profile line graph has been added to the thermal image, to highlight the temperature variationacross the tiled floor. Page 5/15
  6. 6. Demonstration Thermography reportFile: Date: Measuring Time:IV_00386.BMT 08/12/2008 13:32:32Picture parameters:Emissivity: 0.95Refl. temp. [°C]: 20.0Picture markings:Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] RemarksMeasure point 1 18.1 0.95 20.0 Spot Temp 1 to indicate temperature variation across the floorMeasure point 2 18.4 0.95 20.0 Spot Temp 2 to indicate temperature variation across the floorMeasure point 3 15.7 0.95 20.0 Spot Temp 3 to indicate temperature variation across the floorMeasure point 4 14.9 0.95 20.0 Spot Temp 4 to indicate temperature variation across the floorHot spot 1 21.0 0.95 20.0 HS1 Hottest point on Thermal ImageProfile line:Remarks:Thermal survey conducted with Testo 880 series Thermal Imaging camera for Trace and Access application.In Glazed walkway between Lounge and Kitchen extension. The homeowner is complaining of possiblewater leak under the tiled floor. The Thermal image shows the heat pattern effect from the heating pipesunder the floor, travelling the length of the walkway and now a hot spot can be seen clearly. This is anindication of an anomaly, a possible leak from the central Heating system. The temperature in this area hasincreased and is indicating an anomaly that requires investigation. Page 6/15
  7. 7. Demonstration Thermography reportFile: Date: Measuring Time:IV_00585.BMT 10/03/2009 16:15:17Picture parameters:Emissivity: 0.95Refl. temp. [°C]: 20.0Picture markings:Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] RemarksMeasure point 1 22.8 0.95 20.0 Spot Temp 1 for temperature comparison.Measure point 2 15.5 0.95 20.0 Spot Temp 2 for temperature comparison.Measure point 3 15.0 0.95 20.0 Spot Temp 3 for temperature comparison.Measure point 4 23.4 0.95 20.0 Spot Temp 4 for temperature comparison.Measure point 5 26.2 0.95 20.0 Spot Temp 5 for temperature comparison.Profile line:Remarks:Thermal and Digital images of a domestic radiator.Taken with Testo 880 series Thermal imaging camera to demonstrate the capabilities of the camera and theTesto IR software.Spot temperature markers have been added to show the temperature variation across the radiator. Atemperature profile line graph has also been added to visually show the temperature profile across the raditorvertically. Page 7/15
  8. 8. Demonstration Thermography reportFile: Date: Measuring Time:IV_00596.BMT 10/03/2009 16:21:02Picture parameters:Emissivity: 0.95Refl. temp. [°C]: 20.0Picture markings:Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] RemarksMeasure point 1 29.7 0.95 20.0 Spot Temp 1 for temperature comparison.Measure point 2 26.0 0.95 20.0 Spot Temp 2 for temperature comparison.Measure point 3 20.5 0.95 20.0 Spot Temp 3 for temperature comparison.Profile line:Remarks:Thermal and Digital images of a domestic radiator.Taken with Testo 880 series Thermal imaging camera to demonstrate the capabilities of the camera and theTesto IR software.Spot temperature markers have been added to show the temperature variation across the radiator. Atemperature profile line graph has also been added to visually show the temperature profile across the raditordiagonally. The palette has been changed to Hot/Cold. Page 8/15
  9. 9. Demonstration Thermography reportFile: Date: Measuring Time:IV_00601.BMT 10/03/2009 16:24:10Picture parameters:Emissivity: 0.95Refl. temp. [°C]: 20.0Picture markings:Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] RemarksMeasure point 1 31.2 0.95 20.0 -Measure point 2 27.6 0.95 20.0 -Measure point 3 22.0 0.95 20.0 -Measure point 4 39.0 0.95 20.0 -Histogram:Profile line:Remarks:Thermal and Digital images of a domestic radiator.Taken with Testo 880 series Thermal imaging camera to demonstrate the capabilities of the camera and theTesto IR software.Additional spot temperature markers have been added to show the temperature variation across the radiator.A temperature profile line graph has also been added to visually show the temperature profile across theraditor diagonally. A Histogram has also been applied to the thermal image which defines the number oftemperature points at specific temperatures within a defined area. Page 9/15
  10. 10. Demonstration Thermography reportFile: Date: Measuring Time:IV_00537.BMT 29/01/2009 10:58:15Picture parameters:Emissivity: 0.95Refl. temp. [°C]: 20.0Picture markings:Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] RemarksMeasure point 1 29.5 0.95 20.0 Spot Temp 1 indicates Floor temperature above the coilMeasure point 2 29.4 0.95 20.0 Spot Temp 2 indicates Floor temperature above the coilMeasure point 3 22.7 0.95 20.0 Spot Temp 3, indicates the floor temperature at section where there is no heating coilMeasure point 4 28.9 0.95 20.0 Spot Temp 4 indicates Floor temperature above the coilMeasure point 5 29.1 0.95 20.0 Spot Temp 5 indicates Floor temperature above the coilMeasure point 6 24.8 0.95 20.0 Spot Temp 6, indicates the floor temperature at section where there is no heating coilMeasure point 7 30.0 0.95 20.0 Spot Temp 7 indicates Floor temperature above the coilMeasure point 8 29.1 0.95 20.0 Spot Temp 8 indicates Floor temperature above the coilMeasure point 9 24.5 0.95 20.0 Spot Temp 9, indicates the floor temperature at section where there is no heating coilHot spot 1 33.9 0.95 20.0 Auto Hot spot indicator Page 10/15
  11. 11. Demonstration Thermography reportProfile line:Remarks:Thermal and Digital Images of Office Floor, taken with the Testo 880 series Thermal Imaging camera.The Thermal image highlights the location of the underfloor heating coils.A temperature Profile Line graph has been applied to the Thermal image to verify the temperatures acrossthe underfloor heating coils.Spot temperature markers have been added to indicate the temperatures of the system at the floor surface.The thermal image is shown in "Iron" palette. Page 11/15
  12. 12. Demonstration Thermography reportFile: Date: Measuring Time:IV_00538.BMT 29/01/2009 10:58:30Picture parameters:Emissivity: 0.95Refl. temp. [°C]: 20.0Picture markings:Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] RemarksMeasure point 1 34.8 0.95 20.0 -Measure point 2 31.7 0.95 20.0 -Measure point 3 35.0 0.95 20.0 -Hot spot 1 39.1 0.95 20.0 -Profile line:Remarks:Thermal and Digital Images of Office Floor, taken with the Testo 880 series Thermal Imaging camera.The Thermal image highlights the underfloor heating coils.The thermal image also has the auto Hot spot indicator applied to indicate automatically, the hottest point"HS1" in the designated area.A temperature Profile Line graph has been applied to the Thermal image to verify the temperatures acrossthe underfloor heating coils.Spot temperature markers have been added to indicate the temperatures of the system at the floor surface.The Thermal image is shown in "Iron" Palette. Page 12/15
  13. 13. Demonstration Thermography reportFile: Date: Measuring Time:IV_01244.BMT 04/09/2009 17:37:00Picture parameters:Emissivity: 0.96Refl. temp. [°C]: 20.0Picture markings:Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] RemarksMeasure point 1 24.9 0.96 20.0 -Measure point 2 44.4 0.96 20.0 -Measure point 3 51.0 0.96 20.0 -Measure point 4 43.4 0.96 20.0 -Remarks:Demonstration Thermal Survey, at a Domestic Property.Thermal and Digital images of Hot Water system,Dual Pump for shower. Thermal image highlights temperature variation across the equipment and pipework,Spot temperature markers highlight temperature difference in respect of the pipework and pump and indicatewhich sections are operational. Page 13/15
  14. 14. Demonstration Thermography reportFile: Date: Measuring Time:IV_01224.BMT 04/09/2009 16:45:34Picture parameters:Emissivity: 0.96Refl. temp. [°C]: 20.0Picture markings:Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] RemarksMeasure point 1 44.7 0.96 20.0 -Hot spot 1 47.8 0.96 20.0 -Profile line:Remarks:Demonstration Thermal Survey, at a Domestic Property.Thermal and Digital images of Hot Water Pump.Thermal image highlights temperature variation across the equipment and pipework, Spot temperaturemarkers highlight temperature difference in respect of the pipework and pump and indicate which sectionsare operational. Review:Demonstration Thermography Report to highlight the capabilities of the Testo Thermal Imaging cameraS andthe Testo IR software.This is an example report for Demonstration purposes only. The format is the "Standard" report template fromthe selection of Report Templates available in the software.There are various subjects for the Thermal images and this report is compiled to indicate the capability of thecameras and the software for a number of applications in the HVAC Industry.Some of the features of the camera and software have been applied to the Thermal images.Spot Temperature markers have been added to the thermal images to indicate temperatures.Auto Hot / Cold Spot Indicator has been applied, which automatically highlights the Hottest or Coldest point Page 14/15
  15. 15. Demonstration Thermography reportAuto Hot / Cold Spot Indicator has been applied, which automatically highlights the Hottest or Coldest pointin the defined area.Temperature Profile Line Graph shows the temperature variation in graph form across the subject.Palettes Various palettes (from the range available) have been used.The images are automatically Time and Date Stamped to verify the time and date when the images weretaken.The report also details the Emissivity value relating to the image taken. 25/09/2009 , Andy McGrath - Testo Page 15/15

×