Committing to the future                                                     2011Measuring Instruments For Indoor Air Qual...
Information                                   Measurement Engineering For Indoor Air Quality, Light and Sound    CO2 measu...
ContentsMeasuring Instrumentstesto 316-1                Detector for leaks in natural gas pipes                           ...
testo 316-1                                   Detector for leaks in natural gas pipes    The testo 316-1 gas leak detector...
testo 317-1                                  Flue gas spillage detector                                                   ...
testo 317-3                               Ambient carbon monoxide warning    The testo 317-3 CO monitor                  3...
testo 315-2                                         CO warning instrument Use testo 315-2 to check the CO                 ...
testo 315-1                                          Versatile CO measurement – For safety and service     testo 315-1 pro...
testo 315-1                                         Accessories and Technical data Accessories                            ...
testo 535                                           CO2 instrument with probe for HVAC fitters and engineers      testo 53...
testo 540                                    Pocket-sized light intensity measuring instrumentThe sensor of the testo 540 ...
testo 545                                            Light meter with location management      In order to have good quali...
testo 319                                       Flexible fiberscope for fast diagnoses The testo 319 fibre-glass          ...
testo 815                                               Sound level measuring instrument      The ideal instrument for dai...
testo 816                                               Sound level measuring instrument with AC/DC output for data readou...
testo 435                                 All-round talent for ventilation and Indoor Air Quality     All measurement para...
435-1/-2/-3/-4                                       Probes 435-1/-2/-3/-4 IAQ probes                                     ...
435-1/-2/-3/-4                                       Accessories / Technical data      Technical data      Probe type     ...
435-1/-2/-3/-4                                        Ordering data Option: Radio 435-1/-2/-3/-4 Radio module for upgradin...
Testo fast printer                        Universal infrared printer     The universal printer with infrared         Syste...
Testo - IAQ - Light And Sound Instruments
Testo - IAQ - Light And Sound Instruments
Testo - IAQ - Light And Sound Instruments
Testo - IAQ - Light And Sound Instruments
Testo - IAQ - Light And Sound Instruments
Testo - IAQ - Light And Sound Instruments
Testo - IAQ - Light And Sound Instruments
Testo - IAQ - Light And Sound Instruments
Upcoming SlideShare
Loading in …5
×

Testo - IAQ - Light And Sound Instruments

743 views

Published on

Measuring Instruments For Indoor Air Quality,
Light And Sound

Published in: Business, Technology
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
743
On SlideShare
0
From Embeds
0
Number of Embeds
2
Actions
Shares
0
Downloads
20
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Testo - IAQ - Light And Sound Instruments

  1. 1. Committing to the future 2011Measuring Instruments For Indoor Air Quality,Light And Sound CH4 C3H8 CO CO2 Lux dB kHz °C %RH m/s hPa V
  2. 2. Information Measurement Engineering For Indoor Air Quality, Light and Sound CO2 measurement engineering Why CO2 measurement? CO2 concentrations CO2 concentration is used as an indicator when assessing indoor air quality. If the CO2 concentration in indoor air is too high (limit value: 1000 ppm), the air feels ppm Humans expired air: „stuffy and stale“. 40.000 40,000 to 52,000 ppm Bad air quality in rooms (e.g. offices) can lead to tiredness, lack of concentration and illness (Sick Building Syndrome SBS) and is caused, in many cases, by insufficient ventilation. The CO2 concentration in demand controlled ventilating (DCV) systems is used to regulate the supply of fresh air. Stationary CO2 transmitters are used and should be Maximum labour safety checked on a regular basis using hand-held measuring instruments. 5.000 concentration (lower toxic limit): 5,000 ppm 3.000 2.000 Limit value for rooms (offices etc.): 1,000 ppm 1.000 Bad Indoor Air Quality 500 Ideal ventilation City air: 700 ppm 0 Over-ventilated Fresh air: 330 to 400 ppm The parameter light Approximately 80% of all sensations are experienced by the eye. Light is required Effects for this purpose. Fatigue on account of too little light occurs more in the organism as a whole than in Approximately 25% of human energy is needed for the sight process. the eye itself. For this reason, insufficient or bad lighting conditions cannot be identified as the cause of accidents or fatigue. Spectral response of the eye Light is made up of very high electromagnetic oscillation between 380 and 770 nm. According to documentation available approx. 30% of all accidents result directly or They are experienced by the eye as light. indirectly from inadequate lighting. In the interest of accident prevention it is imperative that steps are taken to monitor the situation. Light intensities Humans are day-active creatures, i.e. we are used to a light intensity such as that Different light intensities are recommended by standards bodies, depending on the which is available during the day. Values lie between approx. 5000 Lux on a dull task. Light intensities of approx. 100 to 250 Lux are sufficient for simple tasks. A winter’s day and approx. 100 000 Lux on a sunny summer’s day. minimum of 1000 Lux is required for precision work. The light intensity of artifical lights is ususally between 100 and 1000 Lux. Light intensity Light flux: Unit: Lux (lx) Unit: lumen (lm) Light intensity is the ratio of the Light flux is the total radiation light flux on an area to the area. power emitted from a light source and photometrically assessed. E= Φ Light flux (lm) Light intensity (lx) = Area (m2) A The parameter sound Sound waves are fluctuations in air pressure If they are audible to the human ear we talk about audible sound. The fluctuations in mPa dB pressure occurring with audible sound are extremely low. At a normal pressure of 1013 mbar even changes in the µPa range can stimulate the human ear. A suitable 200.000.000 140 PA I N TH RE S HO L D pressure sensor with the appropriate sensitivity is the microphone. 130 Jets starting 20.000.000 120 Sound level meters have been designed for measurements in the free field. There is Pneumatic drill 110 also a free field if the level falls by 6 dB per duplication of the distance from the source. This is the case in most rooms. 2.000.000 100 Truck 90 Example: 200.000 80 – Office with carpet, curtains and partitions = Free field ! 70 Telephone – Cellar with concrete walls, without furniture, highly reverberant = Reverberant field ! 20.000 60 50 Measuring tips Measuring conditions are ideal if there are absolutely no interfering objects in the 2.000 40 Library sound field. This would be the case, for example, on top of a mountain. Because 30 there are no walls or ceilings on which sound can be reflected, free dispersion is Forest 200 20 guaranteed (free field). In a closed room there is usually a wall opposite the noise 10 L I MI T OF source. This can cause reflections which distort the measured result (reverberant A UDI BI L I TY 20 0 field).2
  3. 3. ContentsMeasuring Instrumentstesto 316-1 Detector for leaks in natural gas pipes Page 4testo 316-2 Gas leak detector with built-in pump Page 4testo 317-1 Flue gas spillage detector Page 5testo 317-2 Gas leak detector Page 5testo 317-3 Ambient carbon monoxide warning Page 6testo gas detector Gas detector Page 6testo 315-2 CO warning instrument Page 7testo 315-1 Versatile CO measurement – For safety and service Page 8testo 535 CO2 instrument with probe for HVAC fitters and engineers Page 10testo 540 Pocket-sized light intensity measuring instrument Page 11testo 545 Light meter with location management Page 12testo 319 Flexible fiberscope for fast diagnoses Page 13testo 815 Sound level measuring instrument Page 14testo 816 Sound level measuring instrument with AC/DC output for data readout Page 15testo 435-1/-2/-3/-4 All-rounder for ventilation and indoor air quality Page 16AccessoriesTesto fast printer Testo fast printer Page 20Ethernet adapter Access Ethernet with Testo measuring instruments Page 21ComSoft 3 - Professional Professional Software including Data Filing Page 22Measurement systemstesto 400 The reference measuring instrument for A/C and ventilation systems Page 24 3
  4. 4. testo 316-1 Detector for leaks in natural gas pipes The testo 316-1 gas leak detector Flexible measurement probe for hard quickly detects even the smallest to reach locations leaks. Optical and audible alarms signal when limits are exceeded TopSafe case protects from dirt and impact (optional) DVGW approval Electronic gas leak detector with flexible measurement probe and battery and calibration protocol Part no. 0632 0316 Technical data Accessories Part no. Probe type Semi-conductor sensor Battery type 9V block battery TopSafe for testo 316, protection case incl. stand, protects from dirt and 0516 0189 Meas. range 0 to 10,000 ppm CH4 Battery life >5h impact Dimensions 190 x 57 x 42 mm Transport case (plastic) 0516 3120 Weight Approx. 300 g for transport and secure storage of measuring instrument and accessories Material/Housing ABS Warranty 2 years 1st alarm limit: from 200 ppm CH4 2nd alarm limit: 10,000 ppm CH4 testo 316-2 Gas leak detector with built-in pump The testo 316-2 gas leak detector Optical and audible alarm with bar indicates when gas concentration display for increasing and dangerous increases or becomes gas concentrations dangerously high. The Trend display shows maximum combination of optical and leakage audible warnings as well as the Integrated pump option of zeroing during the Flexible measurement probe for measurement mean that leaks inaccessible places can be detected quickly and Earphone connection for secure reliably. leakage localization in loud surroundings Electronic gas leak detector with flexible measurement probe, incl. mains charger and earphones Part no. 0632 3162 Technical data Meas. range 10 ppm to 4,0 Vol. % CH4 Battery type NiMH battery 10 ppm to 1,9 Vol. % C3H8 Battery life 6h 10 ppm to 4,0 Vol. % H2 Oper. temp. -5 to +50 °C Lower response 10 ppm Storage temp. -25 to +60 °C thresholds Accessories Part no. Dimensions 190 x 57 x 42 mm 1st alarm limit 200 ppm CH4 Weight 348 g Earphones, black with ear cushions 0554 5001 100 ppm C3H8 200 ppm H2 t90 〈2s Heat-up time 60 s Mains unit (output: 12V, DC, 300mA) 0554 1093 2nd alarm limit 10.000 ppm CH4 Other features Earphone socket 5.000 ppm C3H8 10.000 ppm H2 Warranty 2 years Display 18 segment bar display4 Additional information at www.testo.com
  5. 5. testo 317-1 Flue gas spillage detector mmThe testo 317-1 flue gas spillage Reliable recognition of escaping fluedetector reliably detects escaping gases Ø 10 mm 35heating gases. The practical Bendable measurement probe forinstrument immediately gives off a points which are difficult to accessvisual and audible alarm. It is Audible and visual alarmtherefore not necessary to DVGW approvedactually see the detector. Thebendable probe facilitatesapplications in confined areas. m 0m 20teto 317-1, electronic flue gasspillage detector with flexible probe,incl. batteryPart no.0632 3170Technical dataMeasuring medium Ambient air Diameter/Probe pipe Ø 10 mmReaction time 2s tipBattery type 3 AAA micro batteries Length of probe pipe 35 mm tipDimensions 128 x 46 x 18 mmWeight 300 g Length of probe pipe 200 mmDisplay Visual/audibleWarranty 2 yearstesto 317-2 Gas leak detectorHighly practical gas leak detector Shows gas concentration in visual barfor fast checks on gas pipe displayconnections, with visual bar Sensor self-test following switch-ondisplay. Audible confirmation of readiness to operate Increasing alarm sounds with increasing gas concentration Continuous sound if alarm threshold is exceeded Battery monitoring with optical display Self-test functiontesto 317-2, Gas leak detectorincluding case with belt clip andwrist strap, batteries and calibrationprotocolPart no.0632 3172Technical dataMeas. range 0 to 20.000 ppm CH4 Battery type 2 batteries type micro 0 to 10.000 C3H8 AAA 1.5 V (LR03)Display 8 segment trend display Battery life 4 h (LR03) Oper. temp. -5 to +45 °CAlarm thresholds 10.000 ppm CH4 Storage temp. -20 to +50 °C 5000 C3H8 Audible emitter 85 dB(A)Lower response 100 ppm CH4thresholds 50 C3H8t90 〈5sHeat-up time 60 s Additional information at www.testo.com 5
  6. 6. testo 317-3 Ambient carbon monoxide warning The testo 317-3 CO monitor 3 year warranty on CO sensor detects the presence of carbon Visual and audible alarm monoxide in the surrounding area No zero phase, instrument can be and warns the user both visually used immediately and audibly about dangerous gas Adjustable alarm threshold concentrations e.g. when CO zeroing at site installing and servicing gas heaters. testo 317-3, testo 317-3 CO monitor incl. carrying case with belt clip, headphones, wrist strap, sampler and calibration protocol Part no. 0632 3173 Technical data Meas. range 0 to +1999 ppm Oper. temp. -5 to +45°C Accuracy ±10 ppm (0 to +99 ppm) Battery type 2 batteries Type AAA ±1 digit ±10 % (+100 to +499 Battery life 150 h (with beeper ppm) switched off) ±20 % ( >+500 ppm) Reaction time 40 s Resolution 1 ppm Warranty 2 years on the instrument 3 years on the CO sensor testo gas detector Gas detector According to DVGW leaflet G Audible signals if approaching lower 465-4, gas detectors are explosion limit approved for above-ground gas Continuous tone and warning in detection up to the "lower display if explosion limit is reached explosive limit (LEL)". Testos gas detector is a multi-range gas detector for the gas types methane, propane and hydrogen. Gas concentrations are measured by the semi-conductor sensor in the ppm range and are shown in the display with a resolution of 1 ppm. Gas detector incl. flexible probe extension, rechargeable battery and mains unit for mains operation and Technical data battery recharging, with calibration Display range Methane CH4 1 to 999 ppm, 0.1 to 4.4 vol.% Reaction time 2-3 s protocol Propane C3H8 1 to 999 ppm, 0.1 to 1.9 vol.% Oper. temp. -15 to +40 °C Hydrogen H2 1 to 999 ppm, 0.1 to 4.0 vol.% Storage temp. -25 to +70 °C Part no. Resolution 1 ppm / 0.1 vol.% Dimensions 190 x 40 x 28 mm 0632 0323 First reaction >10 ppm Weight 320 g Voltage supply Built-in battery block, NiMH, 1600 mAh Warranty 2 years on instrument, 1 Ex-Protection Sensor intrinsically-safe in accordance with DMT test institute year on sensor Battery life >8 h6 Additional information at www.testo.com
  7. 7. testo 315-2 CO warning instrument Use testo 315-2 to check the CO Reliable warning of CO poisoning level in ambient air. Even low DVGW approval concentrations of the highly Adjustment of different alarm limits poisonous gas are detected. In Printout with date/time and this way, you can judge whether recommended value (alarm limit) the burner flue gases are being With calibration protocol fully drawn off. TopSafe, protection case for tough applications Quick and practical documentation of data on location, printout with date/time and recommended value (alarm limit) testo 315-2 , CO warning instrument, with battery and calibration protocol Part no. 0632 0317 Accessories Part no. Recommended set Transport and Protection testo 315-2, CO warning setTopSafe (protection case), with bench stand 0516 0443 - CO warning instrument, with battery and calibration protocol (Part no. 0632 0317)protects instrument from dirt and impact - TopSafe (protection case), with bench stand (Part no. 0516 0443)Multi-function clip (for instrument with TopSafe) consisting of multi-function 0554 0398 - Case (Part no. 0516 0191)clip and magnetic holderCase 0516 0191for secure storage of measuring instrumentTransport case (plastic) 0516 3120for transport and secure storage of measuring instrument and accessories Printer and Accessories Technical dataTesto fast printer with wireless infrared interface, 1 roll thermal paper and 4 0554 0549 Meas. range 0 to +2000 ppm CO Oper. temp. +5 to +45 °CAA batteries Accuracy ±10 ppm CO (0 to +100 Battery type 9V block batteryExternal fast charger for 1-4 AA rech. batteries, incl. 4 Ni-MH rech. batteries 0554 0610 ±1 digit ppm CO) Dimensions 215 x 68 x 47 mmwith individual cell charging and charge control display, incl. impulse trickle ±10% of mv (+100 to +2000 ppm CO) Weight 400 gcharging, integrated discharge function, with built-in international mains Display LCD, 2 linesplug, 100-240 V, 300 mA, 50/60 Hz Material/Housing ABSSpare thermal paper for printer (6 rolls) 0554 0569 Resolution 1 ppm CO Warranty 2 years Alarm limits 50/100/500 ppmSpare thermal paper for printer (6 rolls), permanent ink 0554 0568 Zero point Automatically whenmeasurement data documentation legible for up to 10 years adjustment switched on Additional Accessories and Spare Parts9V rech. battery for instrument 0515 0025instead of batteryRecharger for 9V rechargeable battery 0554 0025for external recharging of 0515 0025 batterySpare particle filter (10 off) 0554 0040for CO flue gas probe Calibration CertificatesISO calibration certificate/flue gas 0520 0003calibration points 2.5% O2; 100 and 1000 ppm CO; 800 ppm NO; 80 ppm NO2; 1000 ppm SO2ISO calibration certificate/CO 0520 0039CO probes; calibration points 0; 80 ppm Additional information at www.testo.com 7
  8. 8. testo 315-1 Versatile CO measurement – For safety and service testo 315-1 provides you with all Reliable CO warning the measurement functions Three alarm thresholds are freely needed to service gas heating adjustable systems. While measuring Audible and visual alarm draught, pressure difference Automatic zero point adjustment ortemperature, the instrument can Two temperature sockets to compare also simultaneously show the CO flow and return temperature level in ambient air. In this way, you always have the system´s Compensation of deviations in readings due to temperature safety under your watchful eye. TopSafe case protects from dirt, water and impact (optional) testo 315-1 , CO warning and servicing instrument for gas heating systems, with battery and calibration protocol Part no. 0632 0315 Recommended set The testo 315-1 service set with printout on-site - CO warning and servicing instrument for gas heating systems, with battery and calibration protocol (Part no. 0632 0315) - Pressure set with flue draught probe (Part no. 0554 3150) - Pipe wrap probe with Velcro strip, for temperature measurement on pipes with diameter up to max. 120 mm, Tmax +120°C, TC Type K (Part no. 0628 0020) - Pipe wrap probe with Velcro strip, for temperature measurement on pipes with diameter up to max. 120 mm, Tmax +120°C, TC Type K (Part no. 0628 0020) - Testo fast printer with wireless infrared interface, 1 roll thermal paper and 4 AA batteries (Part no. 0554 0549) - TopSafe (protection case), with bench stand (Part no. 0516 0443) - Transport case (plastic) (Part no. 0516 3120) Weitere Fühler Abbildung Messbereich Genauigkeit t99 Best.-Nr. Druckset mit Kaminzugsonde 215 mm 0554 3150 Ø 5 mm Rohranlegefühler mit Klettband, für die -50 ... +120 °C Klasse 1 90 0628 0020 20 mm sec Temperaturmessung an Rohren mit Durchmesser bis max. 120 mm, Tmax +120 °C, TE Typ K Festkabel gestreckt 395 mm8 Additional information at www.testo.com
  9. 9. testo 315-1 Accessories and Technical data Accessories Part no. Technical data Transport and Protection Meas. range 0 to +2000 ppm CO -200 to +200 hPa -40 to +40 hPaTopSafe (protection case), with bench stand 0516 0443 Accuracy ±10% of mv (+100 to ±0.5 hPa (-49.9 to ±1.5% of mv (-40 to -3protects instrument from dirt and impact ±1 digit +2000 ppm CO) +49.9 hPa) hPa) ±10 ppm CO (0 to +100 ±1.5 hPa (-200 to -50 ±1.5% of mv (+3 to +40Multi-function clip (for instrument with TopSafe) consisting of multi-function 0554 0398 ppm CO) hPa) hPa)clip and magnetic holder ±1.5 hPa (+50 to +200 ±0.03 hPa (-2.99 toCase 0516 0191 hPa) +2.99 hPa)for secure storage of measuring instrumentTransport case (plastic) 0516 3120 Resolution 1 ppm CO (0 to +2000 0.1 hPa (-200 to +200 0.01 hPa (-40 to +40for transport and secure storage of measuring instrument and accessories ppm CO) hPa) hPa) Printer and AccessoriesTesto fast printer with wireless infrared interface, 1 roll thermal paper and 4 0554 0549AA batteries Meas. range -40 to +600 °C -100 to +100 µAExternal fast charger for 1-4 AA rech. batteries, incl. 4 Ni-MH rech. batteries 0554 0610 Accuracy ±0.5% of mv (+100 to ±3 µA (-100 to +100 µA)with individual cell charging and charge control display, incl. impulse trickle ±1 digit +600 °C)charging, integrated discharge function, with built-in international mains ±0.5 °C (0 to +99 °C)plug, 100-240 V, 300 mA, 50/60 HzSpare thermal paper for printer (6 rolls) 0554 0569 Resolution 0.1 °C (-40 to +600 °C) 1 µA (-100 to +100 µA)Spare thermal paper for printer (6 rolls), permanent ink 0554 0568measurement data documentation legible for up to 10 years Additional Accessories and Spare Parts9V rech. battery for instrument 0515 0025 Oper. temp. +5 to +45 °Cinstead of battery Storage temp. -20 to +50 °CRecharger for 9V rechargeable battery 0554 0025 Display LCD, 2 linesfor external recharging of 0515 0025 battery Battery type 9V block battery Calibration Certificates Battery life 16 hISO calibration certificate/flue gas 0520 0003 Dimensions 215 x 68 x 47 mmcalibration points 2.5% O2; 100 and 1000 ppm CO; 800 ppm NO; 80 ppm NO2; 1000 ppm SO2 Weight 400 gISO calibration certificate/CO 0520 0039 Material/Housing ABSCO probes; calibration points 0; 80 ppm Warranty 2 years Additional information at www.testo.com 9
  10. 10. testo 535 CO2 instrument with probe for HVAC fitters and engineers testo 535, the efficient CO2 Long-term monitoring based on measuring instrument for maximum and mean calculation measuring indoor air quality. Bad Long-term stable 2 channel infrared air quality in rooms can lead to sensor tiredness, lack of concentration Highly accurate, highly efficient and illness (Sick Building Repeated calibration is unnecessary Syndrome) due to high CO2 concentration (greater than 1000 ppm) You can print the data on location with date and time on the Testo printer. The TopSafe case protects the instrument from dust, dirt and impact (optional). testo 535, CO2 measuring instrument with permanently attached probe, batteries and calibration protocol Part no. 0560 5350 Accessories Part no. Technical data Transport and Protection Probe type 2 channel infrared sensor Measuring medium Air TopSafe (protection case) with bench stand 0516 0183 Meas. range 0 to +9999 ppm CO2 Oper. temp. 0 to +50 °C protects instrument from impact and dirt Storage temp. -20 to +70 °C Case 0516 0191 Accuracy ±(50 ppm CO2 ±2% of Battery type 9V block battery for secure storage of measuring instrument mv) (0 to +5000 ppm ±1 digit Battery life 6h CO2) Printer and Accessories ±(100 ppm CO2 ±3% of Dimensions 190 x 57 x 42 mm Testo fast printer with wireless infrared interface, 1 roll thermal paper and 4 0554 0549 mv) (+5001 to +9999 Weight 300 g AA batteries ppm CO2) Display LCD, 2 lines External fast charger for 1-4 AA rech. batteries, incl. 4 Ni-MH rech. batteries 0554 0610 Material/Housing ABS with individual cell charging and charge control display, incl. impulse trickle Resolution 1 ppm CO2 Warranty 2 years charging, integrated discharge function, with built-in international mains Auto Off 10 min plug, 100-240 V, 300 mA, 50/60 Hz Spare thermal paper for printer (6 rolls) 0554 0569 Spare thermal paper for printer (6 rolls), permanent ink 0554 0568 measurement data documentation legible for up to 10 years Additional Accessories and Spare Parts 9V rech. battery for instrument 0515 0025 instead of battery Recharger for 9V rechargeable battery 0554 0025 for external recharging of 0515 0025 battery Desk-top power supply with international connection options 0554 1143 Calibration Certificates ISO calibration certificate/CO2 0520 0033 CO2 probes; calibration points 0; 1000; 5000 ppm10 Additional information at www.testo.com
  11. 11. testo 540 Pocket-sized light intensity measuring instrumentThe sensor of the testo 540 is Sensor adapted to spectral sensitivityadapted to the spectral sensitivity of the eyeof the eye. This makes testo ideal Hold function and max./min. valuesfor the measurement of light Display lightintensity. The Hold function allows Protective cap for safe storagean easy readout of the Including wrist strap and belt holdermeasurement values. Max. andmin. values are displayed at the Incl. calibration protocolpress of a button. testo 540 isvery handy, small and easy tooperate.testo 540; light intensity measuringinstrument incl. protective cap,batteries and calibration protocolPart no.0560 0540Technical data Accessories Part no.Meas. range 0 to 99,999 Lux Measurement rate 0.5 s Calibration Certificates Storage temp. -40 to +70 °C ISO calibration certificate/light; Calibration points 0;500;1000;2000;4000 0520 0010Accuracy ±3 % (compared to Protection class IP40 Lux±1 digit reference Class B, DIN Oper. temp. 0 to +50 °C 5032 Part 7) Battery type 2 batteries Type AAA Battery life 200 h (average, without display illumination) Dimensions 133 x 46 x 25 mmResolution 1 Lux (0 to 19.999 Lux) Weight 95 g (incl. batteries and 10 Lux (remaining range) protective cap) Warranty 2 years Additional information at www.testo.com 11
  12. 12. testo 545 Light meter with location management In order to have good quality light, Multi-point or timed mean calculation luminous intensity in the Stores up to 99 file locations workplace, hospitals, offices or Logger function (3000 readings) schools has to fulfill specific Fast documentation on site on the minimum guidelines. This can be Testo printer checked using testo 545. A location list with individual luminous intensity values can be saved and later connected to form a curve using software. This "light profile" provides information on the uniformity of the lighting. testo 545, light meter, incl. probe, battery and calibration protocol Part no. 0560 0545 Accessories Part no. Recommended set Transport and Protection testo 545, Comfort Set incl. printer Transport case (plastic) for measuring instrument, probes and accessories 0516 0445 - testo 545, light meter, incl. probe, battery and calibration protocol (Part no. 0560 0545) now larger for safe and orderly storage - Testo fast printer with wireless infrared interface, 1 roll thermal paper and 4 AA batteries (Part no. Case 0516 0191 0554 0549) for secure storage of measuring instrument - Transport case (plastic) for measuring instrument, probes and accessories (Part no. 0516 0445) Printer and Accessories Testo fast printer with wireless infrared interface, 1 roll thermal paper and 4 0554 0549 AA batteries External fast charger for 1-4 AA rech. batteries, incl. 4 Ni-MH rech. batteries 0554 0610 with individual cell charging and charge control display, incl. impulse trickle charging, integrated discharge function, with built-in international mains plug, 100-240 V, 300 mA, 50/60 Hz Spare thermal paper for printer (6 rolls) 0554 0569 Technical data Spare thermal paper for printer (6 rolls), permanent ink 0554 0568 Meas. range 0 to +100000 Lux Display LCD, 4 lines measurement data documentation legible for up to 10 years PC RS232 interface Software und Zubehör Accuracy Accuracy to DIN 13032- Conn. Fixed cable, coiled ComSoft 3 - Professional with data management 0554 0830 ±1 digit 1: Memory 3000 incl. database, analysis and graphics function, data analysis, trend curve f1 = 6% = V (Lambda) Oper. temp. 0 to +50 °C adaptation RS232 cable 0409 0178 f2 = 5% = cos like rating Storage temp. -20 to +70 °C connects instrument to PC (1.8 m) for data transfer Battery type 9V block battery Ethernet adapter, RS232 - Ethernet incl. software driver, mains unit 0554 1711 Battery life 50 h facilitates data communication in network Resolution 1 Lux (0 to +32000 Lux) Dimensions 220 x 68 x 50 mm Calibration Certificates 10 Lux (0 to +100000 Weight 500 g Lux) ISO calibration certificate/light 0520 0010 Material/Housing ABS Calibration points 0;500;1000;2000;4000 Lux Warranty 2 years12 Additional information at www.testo.com
  13. 13. testo 319 Flexible fiberscope for fast diagnoses The testo 319 fibre-glass • Optics: 6,000 pixels with a field of fiberscope facilitates easy view of 50° inspections at difficult-to-access • Low bending radius (50 mm), small points such as in air ducts, diameter (6 mm) ventilators, machines and motors • Stability thanks to Decabon pipe etc. Diagnoses such as corrosion, • Gooseneck casing for medium friction wear, condition of welding flexibility joints, loose parts and lots more • 3-arm gripper: Grips small objects can be made very early, very (optional) quickly and very easily using endoscopy. The flexible testo 319 can be guided through hollow spaces, bore holes and bends. You can adjust the focus using the focussing wheel. In this way the damaged point can be appraised without the need for dismantling. testo 319 testo 319 set Technical data testo 319 fiberscope Fiberscope set, consisting of testo Number of pixels: 6,000 319 fiberscope, gooseneck tube, Fiber optical illumination field of vision: 50° magnet and mirror attachments, Angle field of vision: 45° +/- 5° bag Min. focus distance: 15 mm (focus) Max. focus distance: 150 mm (light) Part no. Part no. Operating and storage temperature: -20° to +60°C 0632 3191 0563 3191 Working temperature probe: -20° to +80°C Probe diameter: 6.5 mm Accessories Part no. Probe length: 1247 mm +/- 6Flexible push-on gooseneck tube, 0554 3196 Max. bend radius: 50 mm Light source: LED two-point lamp Lamp life: typically 50,000 hDecabon push-on tube 0554 3191 Probe durability: Probe tip waterproof up to handle Short-term resistant to silicone oils, gasoline andTwo-channel push-on hose 0554 3190 kerosene. Oils or gasoline must be wiped off immediately after immersion!Mirror attachment 45° angle 0554 3194 Housing: black Battery type: 3 AA mignon 1.5 VTemperature probe for two-channel hose 0554 3193 Battery life: 4 h Warranty: 2 years. This warranty does not cover damage caused3-arm gripper, for two-channel hose 0554 3192 by misuse, accidents or changes made to the instrument. The warranty becomes void if the handle is opened by the user.Bag for basic set testo 319, gooseneck tube, magnet and mirror attachment 0516 3192 Additional information at www.testo.com 13
  14. 14. testo 815 Sound level measuring instrument The ideal instrument for daily use. Easy to adjust (adjustment Whether it is for air conditioning or screwdriver included) heating, disco noise, machine Frequency weighting in accordance noise or noise in combustion with characteristic curve A and C systems, testo 815 is the ideal Maximum and minimum value partner. memory Built-in tripod knuckle screw (1/4 inch) Switchable time weighting Fast/Slow testo 815, Sound level meter, incl. microphone, wind protection cap and battery Part no. 0563 8155 Accessories Part no. Accessories Calibrator, for regular calibration of testo 815, testo 816 0554 0452 Calibration Certificates ISO calibration cert./sound pressure 0520 0111 calibration points 94 dB; 104 dB; 114 dB at different frequencies ISO calibration certificate sound pressure calibrators 0520 0411 Technical data Technical data Sound level calibrator (0554 0452) Meas. range +32 to +130 dB Oper. temp. 0 to +40 °C Battery type 9V block battery Storage temp. -10 to +60 °C Battery life 40 h Accuracy ±1.0 dB Battery type 9V block battery Warranty 2 years ±1 digit Battery life 70 h Accuracy ±0.5 dB in accordance with Class 2 to 0.1 dB Weight 195 g IEC 60942 Resolution Dimensions 255 x 55 x 43 mm Warranty 2 years Sound pressure level: 94 dB(A)/104 dB(A), adjustable Section meas. ranges: 30 to 80 dB; 50 to 100 Frequency: 1000 Hz dB; 80 to 130 dB Distortion factor: less than 3% Time weighting: FAST 125 ms setting / SLOW 1 s setting Also suitable for 1/2 and 1 inch microphones by other Pressure dependency: -0.0016 dB/hPa manufacturers14 Additional information at www.testo.com
  15. 15. testo 816 Sound level measuring instrument with AC/DC output for data readout Compared to testo 815, the larger Easy to adjust (adjustment model has additional features screwdriver included) which make it ideal for assessors, Frequency weighting in accordance workplace measurements and for with characteristic curve A and C measuring industrial and Maximum and minimum value environmental noise. memory Built-in tripod knuckle screw (1/4 inch) Switchable time weighting Fast/Slow Automatic range switchover Backlit display Mains unit connection Bar graph display AC output for connecting recorders and amplifiers DC output with 10 mV/dB for connecting recorders or data loggers testo 816, Sound level meter, incl. microphone, wind protection cap, battery, stereo jack 3.5 mm, in a practical measurement case Part no. 0563 8165 Accessories Part no. AccessoriesCalibrator, for regular calibration of testo 815, testo 816 0554 0452Plug mains unit 8V DC, 1000 mA with exchangeable plugs 0554 1094 Calibration CertificatesISO calibration cert./sound pressure 0520 0111calibration points 94 dB; 104 dB; 114 dB at different frequenciesISO calibration certificate sound pressure calibrators 0520 0411 Technical data Technical data Sound level calibrator (0554 0452) Meas. range +30 to +130 dB Oper. temp. 0 to +40 °C Battery type 9V block battery 31.5 Hz to 8 kHz Storage temp. -10 to +60 °C Battery life 40 h Accuracy ±1.0 dB Battery type 9V block battery Warranty 2 years ±1 digit Battery life 50 h Accuracy ±0.5 dB in accordance with Class 2 to 0.1 dB Weight 315 g IEC 60942 Resolution Dimensions 309 x 68 x 50 mm Warranty 2 years Sound pressure level: 94 dB(A)/104 dB(A), adjustable Section meas. ranges: 30 to 80 dB; 50 to 100 Frequency: 1000 Hz dB; 80 to 130 dB Distortion factor: less than 3% Time weighting: FAST 125 ms setting / SLOW 1 s setting Also suitable for 1/2 and 1 inch microphones by other Pressure dependency: -0.0016 dB/hPa manufacturers Additional information at www.testo.com 15
  16. 16. testo 435 All-round talent for ventilation and Indoor Air Quality All measurement parameters for Common product advantages testo 435 air conditioning ·Wide selection of probes: The testo 435 provides the possibility of analysing the indoor - IAQ probe for evaluating the indoor air quality via CO2, air temperature, indoor air humidity and air. On the one hand, this serves absolute pressure as an indicator for the well-being - Thermal probe with integrated temperature and air of people at their workplaces, and humidity measurement on the other hand as an important and deciding factor in storage - Vane and hot wire probes and production processes. - Radio probes for temperature Easy operation with user profiles In addition to this, the Indoor Air Quality signals whether the air Printout on the testo printer conditioning system (HVAC) is working with as much energy economy as possible, or whether it needs to be adjusted with the help of testo 435. Further product advantages of the The parameters CO2 , relative variants humidity and room temperature Integrated differential pressure measurement (435- are available for evaluating the 3/-4, not retrofittable) quality of the air. Absolute - for flow measurement pressure, draught, Lux, U-value - for monitoring filters and surface temperature can additionally be determined. In Extended instrument function (435-2/-4, not order to determine the volume retrofittable) flow, all the possibilities of flow - Instrument store for 10,000 readings velocity measurement are - PC software for analysing, archiving and available, such as thermal probes, documenting measurement data vane anemometers and Pitot - Humidity probes with radio or wire tubes. - Lux probe connection possible - Comfort level probe connection possible Versatility with wireless probes - U-value probe connection possible In addition to classical probes on wires, a wireless measurement up to a distance of 20 m (without obstruction) is possible. Damage to the wire or hindrances in usage are thus eliminated. A maximum of three wireless probes can be recorded and displayed with testo 435. The wireless probes are for the measurement parameters temperature and, depending on the instrument type, humidity. The optional, easily plugged-in radio module can be retrofitted at any time. testo 435-1 testo 435-2 testo 435-3 testo 435-4 testo 435-1, multi-functional meas. testo 435-2, multi-functional testo 435-3, multi-functional testo 435-4, multi-functional meas. instr., for A/C, ventilation and Indoor measuring instrument for A/C, measuring instrument with built-in instr. with built-in differential Air Quality, with battery and ventilation and Indoor Air Quality differential pressure measurement pressure measurement for A/C, calibration protocol with readings memory, PC software for air conditioning, ventilation and ventilation and Indoor Air Quality and USB data transmission cable, Indoor Air Quality, with battery and with readings memory, PC software incl. battery and calibration protocol calibration protocol and USB data transmission cable, with battery and calibration protocol Part no. Part no. Part no. Part no. 0560 4351 0563 4352 0560 4353 0563 435416 Additional information at www.testo.com
  17. 17. 435-1/-2/-3/-4 Probes 435-1/-2/-3/-4 IAQ probes Illustration Meas. range Accuracy Part no.IAQ probe to assess Indoor Air Quality, CO2, 0 to +50 °C ±0.3 °C 0632 1535 0 to +100 %RH ±2 %RH (+2 to +98 %RH)humidity, temperature and absolute pressure ±(50 ppm CO2 ±2% of mv) (0 to +5000 ppm CO2) 0 to +10000 ppm CO2 ±(100 ppm CO2 ±3% of mv) (+5001 to +10000 ppm CO2)measurement, with desk-top stand +600 to +1150 hPa ±3 hPaAmbient CO probe, for detecting CO in buildings 0 to +500 ppm CO ±5% of mv (+100.1 to +500 ppm CO) 0632 1235and rooms ±5 ppm CO (0 to +100 ppm CO) Flow probe Illustration Meas. range Accuracy Part no.Thermal velocity probe with built-in temperature -20 to +70 °C ±0.3 °C 0635 1535and humidity measurement, Ø 12 mm, with 0 to +100 %RH ±2 %RH (+2 to +98 %RH) 0 to +20 m/s ±(0.03 m/s +4% of mv)telescopic handle (max. 745 mm)Vane meas. probe, 16 mm diameter, with +0.6 to +40 m/s ±(0.2 m/s +1.5% of mv) 0635 9535telescopic handle max. 890 mm, e.g. for meas. in Oper. temp.ducts, can be used from 0 to +60 °C 0 to +60 °CVane meas. probe, 60 mm diameter, with +0.25 to +20 m/s ±(0.1 m/s +1.5% of mv) 0635 9335telescopic handle max. 910 mm, e.g. for meas. at Oper. temp.duct exit, can be used from 0 to +60 °C 0 to +60 °CHot wire probe for m/s and °C, Ø probe head 7.5 0 to +20 m/s ±(0.03 m/s +5% of mv) 0635 1025mm, with telescopic handle (max. 820 mm) -20 to +70 °C ±0.3 °C (-20 to +70 °C) Funnel measurement Illustration Meas. range Accuracy Part no.Vane meas. probe, 100 mm diameter, for +0.3 to +20 m/s ±0.5 °C 0635 9435measurements with funnel set 0563 4170Funnel set consisting of funnel for disc outlets (Ø 200) and funnel 0563 4170for ventilator (330 x 330 mm) for in- and outgoing air Absolute pressure probes Illustration Meas. range Accuracy Part no.Absolute pressure probe 2000 hPa 0 to +2000 hPa ±5 hPa 0638 1835 Air probes Illustration Meas. range Accuracy t99 Part no. 115 mm 50 mmEfficient, robust NTC air probe -50 to +125 °C ±0.2 °C (-25 to +80 °C) 60 s 0613 1712 ±0.4 °C (remaining range) Ø 5 mm Ø 4 mm Conn.: Fixed cable 1.2 m Surface probes Illustration Meas. range Accuracy t99 Part no.Fast-action surface probe with sprung thermocouple 115 mm -60 to +300 °C Class 2* 3s 0602 0393strip, also for uneven surfaces, measurement range Ø 5 mmshort-term to +500°C, TC Type K Ø 12 mm Conn.: Fixed cablePipe wrap probe for pipe diameter 5 to 65 mm, -60 to +130 °C Class 2* 5s 0602 4592with exchangeable measuring head. Meas. rangeshort-term to +280°C, TC Type K Conn.: Fixed cableClamp probe for measurements on pipes, pipe -50 to +100 °C Class 2* 5s 0602 4692diameter 15 to 25 mm (max. 1"), meas. rangeshort-term up to +130°C, TC Type K Conn.: Fixed cableTemperature probe to determine U-value, triple -20 to +70 °C Class 1±0.1 ±2% of mv 0614 1635sensor system for measuring wall temperature,modelling clay included Immers./penetr. probes Illustration Meas. range Accuracy t99 Part no.Waterproof immersion/penetration probe, TC Type 114 mm 50 mm -60 to +400 °C Class 2* 7s 0602 1293K Ø 5 mm Ø 3.7 mm Conn.: Fixed cable 1.2 m 435-2/-4 IAQ probes Illustration Meas. range Accuracy Part no.Comfort level probe for degree of turbulence 0 to +50 °C ±0.3 °C 0628 0109 0 to +5 m/s ±(0.03 m/s +4% of mv)measurement with telescopic handle (max. 820mm) and stand, meets EN 13779 requirements max. 820 mmLux probe, for measuring light intensity Accuracy to DIN 5032, Part 6: 0635 0545 f1 = 6% = V(Lambda) adjustment f2 = 5% = cos-like weighting, Class C Humidity probes Illustration Meas. range Accuracy Part no.Humidity/temperature probe -20 to +70 °C ±0.3 °C 0636 9735 0 to +100 %RH ±2 %RH (+2 to +98 %RH) Ø 12 mm 435-3/-4 Prandtls Pitot tubes Illustration Oper. temp. Part no.Pitot tube, 350 mm long, stainless steel, -60 to +400 °C 0635 2145measures flow in combination with pressureprobes 500 mm longPitot tube, 350 mm / 500 mm / 1000 mm Ø 7 mm 0 to +600 °C 0635 2045Pitot tube, 1000 mm long 0 to +600 °C 0635 2345 *According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C. Additional information at www.testo.com 17
  18. 18. 435-1/-2/-3/-4 Accessories / Technical data Technical data Probe type NTC Type K Type T Testo humid. sensor, Vane Hot wire Absolute CO2 (IAQ probe) cap. pressure probe Meas. range -50 to +150 °C -200 to +1370 °C -200 to +400 °C 0 to +100 %RH 0 to +60 m/s 0 to+20 m/s 0 to +2000 hPa 0 to +10000 ppm CO2 Accuracy ±0.2 °C (-25 to +74.9 °C) ±0.3 °C (-60 to +60 °C) ±0.3 °C (-60 to +60 °C) See probe data See probe data See probe See probe data See probe data ±0.4 °C (-50 to -25.1 °C) ±(0.2 °C +0.3% of mv) ±(0.2 °C +0.3% of mv) data ±1 digit ±0.4 °C (+75 to +99.9 °C) (remaining range) (remaining range) ±0.5% of mv (remaining range) Resolution 0.1 °C 0.1 °C 0.1 °C 0.1 %RH 0.01 m/s (60 vane) 0.01 m/s 0.1 hPa 1 ppm CO2 0.1 m/s (16 vane) Technical data 435-2/-4 Technical data 435-3/-4 Oper. temp. -20 to +50 °C Probe type Lux Probe type Differential pressure Storage temp. -30 to +70 °C probe, internal Dimensions 220 x 74 x 46 mm Meas. range 0 to +100000 Lux Meas. range 0 to +25 hPa Battery type Alkali manganese, Accuracy See probe data Accuracy ±0.02 hPa (0 to +2 hPa) mignon, Type AA ±1 digit ±1 digit 1% of mv (remaining range) Battery life 200 h (typical vane measurement) Weight 450 g Resolution 1 Lux / 0.1 Hz Overload 200 hPa Material/Housing ABS/TPE/Metal Resolution 0.01 hPa Warranty 2 years Accessories Part no. Accessories Part no. Transport and Protection Printer and Accessories Service case for basic equipment of measuring instrument and probes, 0516 0035 Testo fast printer with wireless infrared interface, 1 roll thermal paper and 4 0554 0549 dimensions: 400 x 310 x 96 mm AA batteries, for printing out measurements on site Service case for measuring instrument, probe and accessories, dimensions 0516 0435 Spare thermal paper for printer (6 rolls), permanent ink, measurement data 0554 0568 520 x 380 x 120 mm documentation legible for up to 10 years Additional Accessories and Spare Parts Spare thermal paper for printer (6 rolls) 0554 0569 Handle for attachable humidity probe head for connection to testo 635, incl. 0430 9735 probe wire, for measurement / calibration of humidity probe head External fast charger for 1-4 AA rech. batteries, incl. 4 Ni-MH rech. batteries 0554 0610 Lithium battery button cellCR2032 mignon type battery for radio handle 0515 0028 with individual cell charging and charge control display, incl. impulse trickle charging, integrated discharge function, with built-in international mains plug, 100-240 V, 300 mA, 50/60 Hz Plug-in mains adapter, 5 VDC 500 mA with European adapter, 100-250 VAC, 0554 0447 50-60 Hz Calibration Certificates testovent 410, volume flow funnel, Ø 340 mm/330x330 mm, incl. case 0554 0410 ISO calibration certificate/temperature, meas. instr. with surface probe; 0520 0071 calibration points +60°C; +120°C; +180°C testovent 415, volume flow funnel, Ø 210 mm/210x210 mm, incl. case 0554 0415 ISO calibration certificate humidity, Calibration points 11.3 %RH and 75.3 0520 0006 %RH at +25°C Funnel set consisting of funnel for disc outlets (Ø 200) and funnel for 0563 4170 ventilator (330 x 330 mm) for in- and outgoing air ISO calibration certificate/pressure 0520 0005 differential pressure; 5 points distributed over meas. range Connection hose, silicone, 5m long, max. load 700 hPa (mbar) 0554 0440 ISO calibration certificate velocity, hot wire, vane anemometer; calibration 0520 0024 points 0.5; 0.8; 1; 1.5 m/s testo saline pots for control and humidity adjustment of humidity probes, 0554 0660 ISO calibration certificate velocity, hot wire, vane anemometer, Pitot tube; 0520 0004 11.3 %RH and 75.3 %RH with adapter for humidity probe, quick checks or calibration points 1; 2; 5; 10 m/s calibration of humidity probe ISO calibration certificate/Velocity, hot wire, vane anemometer, Pitot tube; 0520 0034 Sintered PTFE filter, Ø 12 mm, for corrosive media, High humidity range 0554 0756 calibration points 5; 10; 15; 20 m/s (long-term measurements), high flow velocities. ISO calibration certificate/light, Calibration points 0;500;1000;2000;4000 0520 0010 Lux Stainless steel sintered cap, Ø 12 mm, is screwed onto humidity probe, for 0554 0647 ISO calibration certificate/CO2, CO2 probes; calibration points 0; 1000; 0520 0033 measurements at higher flow velocities or in contaminated air 5000 ppm Adhesive material for fixing and sealing 0554 076118 Additional information at www.testo.com
  19. 19. 435-1/-2/-3/-4 Ordering data Option: Radio 435-1/-2/-3/-4 Radio module for upgrading measuring instrument with radio optionCountry versions Radio freq. Part no.Radio module for measuring instrument, 869.85 MHz, approval for the countries: DE, FR, UK, BE, NL, ES, IT, SE, 869.85 MHz FSK 0554 0188AT, DK, FI, HU, CZ, PL, GR, CH, PT, SI, MT, CY, SK, LU, EE, LT, IE, LV, NORadio module for measuring instrument, 915.00 MHz FSK, approval for USA, CA, CL 915.00 MHz FSK 0554 0190 Assembled for you: Radio handles with probe head Radio handles with probe head for surface measurement Meas. range Accuracy Resolution t99 120 mm -50 to +350 °C Radio handle: 0.1 °C (-50 to +199.9 °C) 5s 40 Radio handle for attachable probe heads with mm Short-term to +500 °C ±(0.5 °C +0.3% of mv) (-40 to +500 °C) 1.0 °C (remaining range) T/C probe head for surface measurement ±(0.7 °C +0.5% of mv) (remaining range) Ø 5 mm Ø 12 T/C probe head: Class 2 mmCountry versions Radio freq. Part no.Radio handle for plug-in probe heads, incl. T/C adapter, approval for the countries: DE, FR, UK, BE, NL, ES, IT, SE, AT, DK, FI, 869.85 MHz FSK 0554 0189HU, CZ, PL, GR, CH, PT, SI, MT, CY, SK, LU, EE, LT, IE, LV, NORadio immersion/penetration probes, T/C probe head for surface measurement, attachable to radio handle, T/C Type K 0602 0394Radio handle for plug-in probe heads, incl. T/C adapter, approval for USA, CA, CL 915.00 MHz FSK 0554 0191T/C probe head for surface measurement, attachable to radio handle, T/C Type K 0602 0394435-2/-4Radio probes incl. humidity probe head Meas. range Accuracy Resolution 0 to +100 %RH ±2 %RH (+2 to +98 %RH) 0.1 %RH Radio handle for attachable probe heads with -20 to +70 °C ±0.3 °C 0.1 °C humidity probe headCountry versions Radio freq. Part no.Radio handle for plug-in probe heads, incl. T/C adapter, approval for the countries: DE, FR, UK, BE, NL, ES, IT, SE, AT, DK, FI, HU, CZ, PL, GR, CH, 869.85 MHz FSK 0554 0189PT, SI, MT, CY, SK, LU, EE, LT, IE, LV, NOHumidity probe head, attachable to radio handle 0636 9736Radio handle for plug-in probe heads, incl. T/C adapter, approval for USA, CA, CL 915.00 MHz FSK 0554 0191Humidity probe head, attachable to radio handle 0636 9736 Radio probes: General technical data Radio handle Measuring rate 0.5 s or 10 s, adjustable Radio transmission Unidirectional on handle Battery type 2 AAA micro batteries Oper. temp. -20 to +50 °C Battery life 215 h (meas. rate 0.5 s) Radio coverage Up to 20 m (without Storage temp. -40 to +70 °C 6 months (meas. rate 10 s) obstructions) Protection class IP54 Additional information at www.testo.com 19
  20. 20. Testo fast printer Universal infrared printer The universal printer with infrared System compatibility with other Testo interface saves you time since it measuring instruments (also saves the print data prior to downward compatibility) printing. Data transfer is Fast data transfer, the measuring completed within 2 seconds. The instrument is ready for use again instrument is then immediately within 2 sec. ready for operation. Fast print function thanks to newest line printer The readings are saved black on Energy-saving Auto-off/Wake-up white with date and time. function Testo design with integrated magnetic plate Robust housing (adapted to testo 327) Mains operation possible (same Testo fast printer with wireless mains unit as for testo 327/330) infrared interface, 1 roll thermal paper and 4 AA batteries Part no. 0554 0549 Technical data Accessories Part no. Printer type infrared-controlled Oper. temp. 0 to +50 °C Spare thermal paper for printer (6 rolls) 0554 0569 thermal printer, Storage temp. -40 to +60 °C adjustable contrast, Power supply 4 AA batteries 1.5 V (or Spare thermal paper for printer (6 rolls), permanent ink, measurement data 0554 0568 graphic-capable rechargeables) documentation legible for up to 10 years Mains unit GV/1.2A External fast charger for 1-4 AA rech. batteries, incl. 4 Ni-MH rech. batteries 0554 0610 Reception radius max. 2 m Weight 430 g with individual cell charging and charge control display, incl. impulse trickle Dimensions 147 x 77 x 47 mm charging, integrated discharge function, with built-in international mains plug, 100-240 V, 300 mA, 50/60 Hz20 Additional information at www.testo.com

×