Your SlideShare is downloading. ×
ProCurve Secure Router 7000dl Series
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×

Introducing the official SlideShare app

Stunning, full-screen experience for iPhone and Android

Text the download link to your phone

Standard text messaging rates apply

ProCurve Secure Router 7000dl Series

207
views

Published on


0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
207
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
1
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. QuickSpecs ProCurve Secure Router 7000dl Series Overview ProCurve Secure Router 7102dl ProCurve Secure Router 7203dl Models ProCurve Secure Router 7102dl J8752A ProCurve Secure Router 7203dl J8753A Introduction The ProCurve Secure Router 7000dl series provides an affordable and scalable platform for SMB as well as medium and large enterprises to connect branch offices to their headquarter locations. The Secure Router 7000dl series offers a variety of WAN interface modules and supports wire-speed routing performance with integrated security and convergence capabilities to secure branch office connections edge to edge while enabling centralized management via command from the center. Features and Benefits Security-enabled: Stateful firewall includes an integrated stateful firewall and a Cyber Attack Defense Engine that stops common attacks firewall: to ensure continuous availability of critical Internet-dependent applications; the firewall also supports NAT and port- forwarding operations IPSec VPN optional IPSec VPN module enables site-to-site and client sessions; tunneling protocols include IPSec and VPN: GRE; encryption methods include 3DES-CBC, DES-CBC, AES-CBC, 128-bit, 192-bit, and 256-bit; hash algorithms supported are SHA-1, MD5, and manual IPSec policies; supports the ability to route traffic between tunnels (hub and spoke VPNs) 802.1X supplicant supports 802.1X supplicant mode where the router transmits and receives EAP requests from the supplicant: authenticator to support 802.1X-enabled environments and prevent rogue networking equipment deployments Management security utilizes SSHv2, secure copy, encrypted user passwords, and user authentication via AAA and security: RADIUS to prevent unauthorized management access; utilizes SSL to encrypt all HTTP traffic, allowing secure access to the browser-based management GUI in the router; supports AAA systems, including authentication methods that utilize RADIUS servers or local user database for operator and privileged mode passwords Access control lists (ACLs): provide IP layer 3 filtering based on source/destination IP address/subnet and source/destination TCP/UDP port number Ease of use: Industry-standard CLI utilizes familiar CLI to minimize training and certification costs CLI: Link Layer Discovery Protocol (LLDP): supported by ProCurve Manager to enable real-time mapping of Ethernet nodes connected to the router ports Compact flash port facilitates remote site installation by allowing system image and configuration file to boot from port: externally accessible compact flash drive; can be configured to support ProCurve "AutoSynch" technology to simultaneously update external CF and onboard flash with system image and configuration file to limit downtime and switchover in the event of failure Dual flash images provide independent primary and secondary OS and configuration files for backup while images: DA - 12288 North America — Version 1 — June 6, 2005 Page 1
  • 2. QuickSpecs ProCurve Secure Router 7000dl Series Overview upgrading; the file system also supports the storage of multiple configuration and image files Firewall and VPN wizards the GUI provides a simplified format for configuring firewall policies and access control lists wizards: (ACLs), as well as setting up VPN tunnels; novice and expert users will find the GUI to be intuitive and easy to use Central management supports SNMPv2 and can be centrally managed to archive and update configuration and management: software image files Convergence-ready: VoIP support supports H.323 and SIP ALGs through a firewall support: Layer 2/3/4 QoS mechanisms supports IP Precedence and DiffServ priority tagging based on IP address, IP type of mechanisms: service (ToS), L3 protocol, TCP/UDP port number, and source port Scheduling mechanisms supports Weighed Fair Queuing (WFQ), FIFO, Low Latency Queuing (LLQ), and Priority mechanisms: Queuing (PQ) Policy and shaping supports Frame Relay Traffic Shaping (FRTS) and frame relay fragmentation (FRF.12) to minimize shaping: insertion delay across low-speed WAN links Redundancy and high availability: Multilink capability MLFR and MLPPP enable multiple T1/E1 ports to be aggregated and dynamically load balanced capability: across Frame Relay or PPP links Optional redundant power supply provides uninterrupted power (provided by ProCurve 600 RPS/EPS) supply: Supports standardized protocols: IP routing protocols supports static routes, RIP, RIPv2, OSPF, and BGP4 protocols: VLAN support and tagging support 802.1Q (4,095 VLAN IDs) and 256 VLANs simultaneously tagging: IP multicast supports IGMPv2 and multicast stub routing multicast: WAN protocols PPP, Frame Relay, IPSec, HDLC encapsulation, MLPPP, MLFR protocols: Low cost of ownership: Lifetime warranty for as long as you own the product, with next-business-day advance replacement (available in most warranty: countries) Services ProCurve Secure Router 3-year, 4-hour onsite, 13x5 coverage for hardware UA432A/E 7102dl 3-year, 4-hour onsite, 24x7 coverage for hardware UA433A/E 3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone support UA434A/E ProCurve Secure Router 3-year, 4-hour onsite, 13x5 coverage for hardware UA435A/E 7203dl 3-year, 4-hour onsite, 24x7 coverage for hardware UA436A/E 3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone support UA437A/E Check http://www.hp.com/go/procurveservices for part numbers and service-level descriptions. For details about services and response times in your area, please contact your local HP sales office. DA - 12288 North America — Version 1 — June 6, 2005 Page 2
  • 3. QuickSpecs ProCurve Secure Router 7000dl Series Technical Specifications ProCurve Secure Router Ports 2 10/100 ports (IEEE 802.3u Type 100Base-TX) 7102dl (J8752A) 2 dl module slots 1 Compact Flash port 500 Max VPN sessions 1 RS-232C DB-9 console port RPS option N/A VPN encryption module Yes slot Physical characteristics Dimensions 17.42 x 11.52 x 1.73 in. (44.25 x 29.26 x 4.39 cm) (1U height) Weight (fully loaded) 10.26 lb. (4.62 kg) Memory Flash capacity 32 MB SDRAM 128 MB T-Flow management Packet buffer size 8 MB per module (J4879A) Processor type and speed 4 Motorola PowerPC @ 466 MHz each SDRAM capacity 1.25 GB per module Flash capacity 16 MB Mounting Mounts in an EIA-standard 19 in. telco rack or equipment cabinet Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only Performance WAN throughput Up to 4xT1/E1 lines Environment Operating temperature 32° to 122° F (0° to 50° C) Operating relative 0% to 95%, non-condensing humidity Non-operating/ -4° to 158° F (-20° to 70° C) Storage temperature Non-operating/ 0% to 95%, non-condensing Storage relative humidity Electrical characteristics Voltage 100-127 VAC/200-240 VAC Current 0.4 A/0.2 A Power consumption 15 W Frequency 50/60 Hz Safety CSA 22.2 No. 60950 3rd edition; CE Labeled; cUL Certified; EN 60950/IEC 60950, 3rd edition; UL 60950; UL Listed; AS/NZS60950; KN60950; GOST R MEK60950; TS60950 Emissions FCC Rules Part 15, Subpart B Class A; CISPR22/A2:2002; EN55022/A2:2002; ICES-003; VCCI V-3/2000.04; IEC/EN61000-3-2; IEC/EN61000-3-3; EN55024/A1:2001; IEC61000: 4-2, 4-3, 4-4, 4-5, 4-6, 4-8, 4-11; BSMI CNS13438, MIC KN22 Telecom TBR-1; TBR-2; TBR-3; TBR-12; TBR-13; TBR-21; ITU-T G.992.1; NZ PTC 200, PTC 270; AS/ACIF 5016. 5031. 5043; ETSI TS101 388; FCC CFR47 p.68, TIA 968-A; IC CS-03; JATE MPHPT; TEC IR/TCP-01/03; MIC; CHINA NAL; IDA TS PSTN1; SIRiM; DGT PSTN01; ICASA TE-0001/03/08 (except K21); NOM-151-SCT1 DA - 12288 North America — Version 1 — June 6, 2005 Page 3
  • 4. QuickSpecs ProCurve Secure Router 7000dl Series Technical Specifications ProCurve Secure Ports 2 10/100 ports (IEEE 802.3u Type 100Base-TX) Router 7203dl 2 dl module slots (J8753A) 1 dl wide module slot 1 Compact Flash port 500 Max VPN sessions 1 RS-232C DB-9 console port RPS option Yes VPN encryption Yes module slot Physical Dimensions 17.42 x 11.52 x 1.73 in. (44.25 x 29.26 x 4.39 cm) (1U characteristics height) Weight (fully loaded) 10.95 lb. (4.93 kg) Memory Flash capacity 32 MB SDRAM 256 MB Mounting Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only Performance WAN throughput Up to 8xT1/E1 lines Environment Operating 32° to 122° F (0° to 50° C) temperature Operating relative 0% to 95%, non-condensing humidity Non-operating/ -4° to 158° F (-20° to 70° C) Storage temperature Non-operating/ 0% to 95%, non-condensing Storage relative humidity Shock and vibration EN 60068 (IEC 68) Electrical Voltage 100-127 VAC/200-240 VAC characteristics Current 0.4 A/0.2 A Power consumption 50 W Frequency 50/60 Hz Safety CSA 22.2 No. 60950 3rd edition; CE Labeled; cUL Certified; EN 60950/IEC 60950, 3rd edition; UL 60950; UL Listed; AS/NZS60950; KN60950; GOST R MEK60950; TS60950 Emissions FCC Rules Part 15, Subpart B Class A; CISPR22/A2:2002; EN55022/A2:2002; ICES-003; VCCI V-3/2000.04; IEC/EN61000-3-2; IEC/EN61000-3-3; EN55024/A1:2001; IEC61000: 4-2, 4-3, 4-4, 4-5, 4-6, 4-8, 4-11; BSMI CNS13438, MIC KN22 Telecom TBR-1; TBR-2; TBR-3; TBR-12; TBR-13; TBR-21; ITU-T G.992.1; NZ PTC 200, PTC 270; AS/ACIF 5016. 5031. 5043; ETSI TS101 388; FCC CFR47 p.68, TIA 968-A; IC CS-03; JATE MPHPT; TEC IR/TCP-01/03; MIC; CHINA NAL; IDA TS PSTN1; SIRiM; DGT PSTN01; ICASA TE-0001/03/08 (except K21); NOM-151-SCT1 DA - 12288 North America — Version 1 — June 6, 2005 Page 4
  • 5. QuickSpecs ProCurve Secure Router 7000dl Series Modules and RPS dl Modules ProCurve Secure Router dl Connectivity Connectors: (T1) RJ-48C, 1 RJ-45 for optional backup module 1xT1 Module (J8451A) T1: 1.544 Mbps (24x64 kbps) FrT1: DS0 channelized (Nx64 kbps) 1-port T1/FrT1 dl module Line code: AMI/B8ZS with integrated CSU/DSU. Input signal: 0 to -36 dB (DS1) Includes 1 RJ48-RJ48 Line build out: 0, -7.5, -15, -22.5 dB Telco straight-through Physical Dimensions: 4.65 x 3.2 x 1.3 in. (11.81 x 8.13 x 3.3 cm) cable (5 m). characteristics Weight: 0.13 lb. (0.06 kg) Environment Operating temperature: 32° to 122° F (0° to 50° C) Operating relative humidity: 0% to 95%, non-condensing Non-operating/Storage temperature: -40° to 185° F (-40° to 85° C) Non-operating/Storage relative humidity: 0% to 95%, non-condensing ProCurve Secure Router dl Connectivity Connectors: (T1) RJ-48C, (DSX-1) RJ-48C, 1 RJ-45 for optional backup 1xT1 + DSX-1 Module module (J8452A) T1: 1.544 Mbps (24x64 kbps) FrT1: DS0 (Nx64 kbps); programmable DS0 assignment to allow DSX-1 TDM 1-port T1 dl module with drop off to PBX integrated CSU/DSU and Line code: AMI/B8ZS DSX-1 TDM interface to Input signal: 0 to -36 dB (DS1) connect to a PBX for voice Line build out: 0, -7.5, -15, -22.5 dB service. Includes 2 RJ48- Physical Dimensions: 4.65 x 3.2 x 1.3 in. (11.81 x 8.13 x 3.3 cm) RJ48 Telco straight- characteristics Weight: 0.13 lb. (0.06 kg) through Environment Operating temperature: 32° to 122° F (0° to 50° C) cables (5 m). Operating relative humidity: 0% to 95%, non-condensing Non-operating/Storage temperature: -40° to 185° F (-40° to 85° C) Non-operating/Storage relative humidity: 0% to 95%, non-condensing ProCurve Secure Router dl Connectivity Connectors: (2xT1) RJ-48C, 1 RJ-45 for optional backup module 2xT1 Module (J8453A) T1: 1.544 Mbps (24x64 kbps) for each T1 interface FrT1: DS0 channelized (Nx64 kbps) 2-port T1/FrT1 dl module Line code: AMI/B8ZS with integrated CSU/DSU. Input signal: 0 to -36 dB (DS1) Includes 2 RJ48-RJ48 Line build out: 0, -7.5, -15, -22.5 dB Telco straight-through Physical Dimensions: 4.65 x 3.2 x 1.3 in. (11.81 x 8.13 x 3.3 cm) cables (5 m). characteristics Weight: 0.13 lb. (0.06 kg) Environment Operating temperature: 32° to 122° F (0° to 50° C) Operating relative humidity: 0% to 95%, non-condensing Non-operating/Storage temperature: -40° to 185° F (-40° to 85° C) Non-operating/Storage relative humidity: 0% to 95%, non-condensing DA - 12288 North America — Version 1 — June 6, 2005 Page 5
  • 6. QuickSpecs ProCurve Secure Router 7000dl Series Modules and RPS ProCurve Secure Router dl Connectivity Connectors: (E1) RJ-48C, 1 RJ-45 for optional backup module 1xE1 Module (J8454A) E1: 2.048 Mbps (30x64 kbps) FrE1: DS0 channelized (Nx56/64 kbps) 1-port E1/FrE1 dl module Line code: AMI or HDB3 with integrated CSU/DSU. Framing: FAS with optional CRC-4 Includes 1 RJ48-RJ48 Receiver sensitivity: -30 dB Telco straight-through Physical Dimensions: 4.65 x 3.2 x 1.3 in. (11.81 x 8.13 x 3.3 cm) cable (5 m). characteristics Weight: 0.13 lb. (0.06 kg) Environment Operating temperature: 32° to 122° F (0° to 50° C) Operating relative humidity: 0% to 95%, non-condensing Non-operating/Storage temperature: -40° to 185° F (-40° to 85° C) Non-operating/Storage relative humidity: 0% to 95%, non-condensing ProCurve Secure Router dl Connectivity Connectors: (E1) RJ-48C, (G.703) RJ-48C, 1 RJ-45 for optional backup 1xE1+G.703 Module module (J8455A) E1: 2.048 Mbps (30x64 kbps) FrE1: DS0 channelized (Nx56/64 kbps) 1-port E1/FrE1 dl module Line code: AMI or HDB3 with integrated CSU/DSU Framing: FAS with optional CRC-4 and G.703 TDM interface Receiver sensitivity: -30 dB to connect to a PBX for Physical Dimensions: 4.65 x 3.2 x 1.3 in. (11.81 x 8.13 x 3.3 cm) voice service. Includes 2 characteristics Weight: 0.16 lb. (0.07 kg) RJ48-RJ48 Telco straight- Environment Operating temperature: 32° to 122° F (0° to 50° C) through cables (5 m). Operating relative humidity: 0% to 95%, non-condensing Non-operating/Storage temperature: -40° to 185° F (-40° to 85° C) Non-operating/Storage relative humidity: 0% to 95%, non-condensing ProCurve Secure Router dl Connectivity Connectors: (2xE1) RJ-48C, 1 RJ-45 for optional backup module 2xE1 Module (J8456A) E1: 2.048 Mbps (30x64 kbps) for each E1 interface FrE1: DS0 channelized (Nx56/64 kbps) 2-port E1/FrE1 dl module Line code: AMI or HDB3 with integrated CSU/DSU. Framing: FAS with optional CRC-4 Includes 2 RJ48-RJ48 Receiver sensitivity: -30 dB Telco straight-through Physical Dimensions: 4.65 x 3.2 x 1.3 in. (11.81 x 8.13 x 3.3 cm) cables (5 m). characteristics Weight: 0.13 lb. (0.06 kg) Environment Operating temperature: 32° to 122° F (0° to 50° C) Operating relative humidity: 0% to 95%, non-condensing Non-operating/Storage temperature: -40° to 185° F (-40° to 85° C) Non-operating/Storage relative humidity: 0% to 95%, non-condensing DA - 12288 North America — Version 1 — June 6, 2005 Page 6
  • 7. QuickSpecs ProCurve Secure Router 7000dl Series Modules and RPS ProCurve Secure Router dl Connectivity Connectors: (ADSL) RJ-11, 1 RJ-45 for optional backup module 1-port ADSL2+ Annex B Supported standards: ADSL, ADSL2, and ADSL2+ for Annex B over ISDN Module (J8759A) lines Min/Max upstream rate: 1-port ADSL2+ Annex B dl Module supports ADSL: 32 kbps to 800 kbps ADSL/ADSL2/ADSL2+ ADSL2: 32 kbps to 800 kbps over ISDN lines ADSL2+: 32 kbps to 2 Mbps Min/Max downstream rate: ADSL: 224 kbps to 8 Mbps ADSL2: 224 kbps to 12 Mbps ADSL2+: 224 kbps to 24.5 Mbps Line code: DMT Physical Dimensions: 4.65 x 3.2 x 1.3 in. (11.81 x 8.13 x 3.3 cm) characteristics Weight: 0.18 lb. (0.08 kg) Environment Operating temperature: 32° to 122° F (0° to 50° C) Operating relative humidity: 0% to 95%, non-condensing Non-operating/Storage temperature: -40° to 185° F (-40° to 85° C) Non-operating/Storage relative humidity: 0% to 95%, non-condensing NOTE: ADSL2/ADSL2+ capability not available at first release, but will be upgradable via a future software release. ProCurve Secure Router dl Connectivity Connectors: (ADSL) RJ-11, 1 RJ-45 for optional backup module 1-port ADSL2+ Annex A Supported standards: ADSL, ADSL2, and ADSL2+ for Annex A over POTS Module (J8459A) lines Min/Max upstream rate: 1-port ADSL2+ Annex B dl Module supports ADSL: 32 kbps to 800 kbps ADSL/ADSL2/ADSL2+ ADSL2: 32 kbps to 800 kbps over ISDN lines ADSL2+: 32 kbps to 2 Mbps Min/Max downstream rate: ADSL: 224 kbps to 8 Mbps ADSL2: 224 kbps to 12 Mbps ADSL2+: 224 kbps to 24.5 Mbps Line code: DMT Physical Dimensions: 4.65 x 3.2 x 1.3 in. (11.81 x 8.13 x 3.3 cm) characteristics Weight: 0.18 lb. (0.08 kg) Environment Operating temperature: 32° to 122° F (0° to 50° C) Operating relative humidity: 0% to 95%, non-condensing Non-operating/Storage temperature: -40° to 185° F (-40° to 85° C) Non-operating/Storage relative humidity: 0% to 95%, non-condensing NOTE: ADSL2+ capability not available at first release, but will be upgradable via a future software release. DA - 12288 North America — Version 1 — June 6, 2005 Page 7
  • 8. QuickSpecs ProCurve Secure Router 7000dl Series Modules and RPS ProCurve Secure Router dl Connectivity Connectors: (Serial) 26-pin interface, 1 RJ-45 for optional backup module 1-port Serial Module Rate: Up to 10 Mbps to an external CSU/DSU (J8458A) Interface: V.35 or X.21 interface support 1-port serial dl module Physical Dimensions: 4.65 x 3.2 x 1.3 in. (11.81 x 8.13 x 3.3 cm) supporting up to 10 Mbps characteristics over V.35/X.21 DTE interfaces to an external Weight: 0.11 lb. (0.05 kg) CSU/DSU. Requires a V.35 or X.21 serial cable Environment Operating temperature: 32° to 122° F (0° to 50° C) to connect to an external Operating relative humidity: 0% to 95%, non-condensing CSU/DSU. Serial interface Non-operating/Storage temperature: -40° to 185° F (-40° to 85° C) operates in DTE Non-operating/Storage relative humidity: 0% to 95%, non-condensing mode only. dl Backup Modules ProCurve Secure Router dl Supports speeds from 300 bps to 33.6 kbps. Analog Modem Backup Module (J8462A) Physical Dimensions: 3.75 x 2.5 x 0.73 in. (9.53 x 6.35 x 1.85 cm) 1-port v.90 analog characteristics modem module attaches Weight: 0.36 lb. (0.16 kg) as a daughter card to dl modules to provide backup capability. Users Environment Operating temperature: 32° to 122° F (0° to 50° C) can also initiate an out-of- Operating relative humidity: 0% to 95%, non-condensing band console session Non-operating/Storage temperature: -40° to 185° F (-40° to 85° C) through the modem Non-operating/Storage relative humidity: 0% to 95%, non-condensing interface. ProCurve Secure Router dl Connectivity Connector: RJ-45 1-port ISDN BRI S/T Interface: S/T interface support; support for 1B channel (64 kbps) Backup Module (J8461A) Physical Dimensions: 3.75 x 2.5 x 0.73 in. (9.53 x 6.35 x 1.85 cm) 1-port ISDN BRI S/T characteristics module attaches as a Weight: 0.4 lb. (0.18 kg) daughter card to dl Environment Operating temperature: 32° to 122° F (0° to 50° C) modules to provide Operating relative humidity: 0% to 95%, non-condensing backup capability. Includes Non-operating/Storage temperature: -40° to 185° F (-40° to 85° C) 1 RJ11-RJ45 straight- Non-operating/Storage relative humidity: 0% to 95%, non-condensing through cable (3 m). DA - 12288 North America — Version 1 — June 6, 2005 Page 8
  • 9. QuickSpecs ProCurve Secure Router 7000dl Series Modules and RPS ProCurve Secure Router dl Connectivity Connector: RJ:45 1-port ISDN BRI U Backup Interface: U interface support; support for 1B channel (64 kbps) Module (J8460A) Physical Dimensions: 3.75 x 2.5 x 0.73 in. (9.53 x 6.35 x 1.85 cm) 1-port ISDN BRI U module characteristics attaches as a daughter Weight: 0.4 lb. (0.18 kg) card to dl modules to Environment Operating temperature: 32° to 122° F (0° to 50° C) provide backup capability. Operating relative humidity: 0% to 95%, non-condensing Includes 1 RJ11-RJ45 Non-operating/Storage temperature: -40° to 185° F (-40° to 85° C) straight-through cable (3 Non-operating/Storage relative humidity: 0% to 95%, non-condensing m). dl Wide Modules ProCurve Secure Router dl Connectivity Connectors: (8xT1/E1) RJ-48C Wide 8xT1/E1 Module T1: 1.544 Mbps (24x64 kbps) for each T1 (J8463A) E1: 2.048 Mbps (30x64 kbps) for each E1 FrT1/E1: DS0 channelized (Nx64 kbps) 8-port T1/FrT1/E1/FrE1 dl T1 line code: AMI/B8ZS wide module can support E1 line code: HDB3 either T1 or E1 Physical Dimensions: 6.0 x 8.64 x 0.94 in. (15.24 x 21.95 x 2.39 cm) functionality via onboard characteristics Weight: 2.93 lb. (1.33 kg) dipswitch setting. Includes Environment Operating temperature: 32° to 122° F (0° to 50° C) 8 RJ48-RJ48 Telco Operating relative humidity: 0% to 95%, non-condensing straight-through cables (5 Non-operating/Storage temperature: -40° to 185° F (-40° to 85° C) m). Non-operating/Storage relative humidity: 0% to 95%, non-condensing Cables ProCurve Secure Router Connectivity Connectors: 26-pin interface to dl serial module, V.35 DTE interface to Serial Cable V.35 DTE external CSU/DSU (J8757A) Length: 2-meter cable V.35 DTE serial cable to be used with ProCurve Secure Router Serial dl module to connect to external CSU/DSU ProCurve Secure Router Connectivity Connectors: 26-pin interface to dl serial module, X.21 DTE interface to Serial Cable X.21 DTE external CSU/DSU (J8755A) Length: 2-meter cable X.21 DTE serial cable to be used with ProCurve Secure Router Serial dl module to connect to external CSU/DSU DA - 12288 North America — Version 1 — June 6, 2005 Page 9
  • 10. QuickSpecs ProCurve Secure Router 7000dl Series Modules and RPS VPN Encryption Modules ProCurve Secure Router Terminates IPSec VPN site-to-site and client sessions 7100/7200 IPSec VPN Encryption: DES, 3DES, AES Module (J8471A) Physical Dimensions (D x W x H): 3.12 x 3.1 x 1.26 in. (7.92 x 7.87 x 3.2 cm) characteristics Weight: 0.27 lb. (0.12 kg) IPSec VPN encryption module for Environment Operating temperature: 32° to 122° F (0° to 50° C) 7100dl/7200dl series Operating relative humidity: 0% to 95%, non-condensing routers enables VPN Non-operating/Storage temperature: -40° to 185° F (-40° to 85° C) capability Non-operating/Storage relative humidity: 0% to 95%, non-condensing VPN Client Licenses ProCurve VPN Client 100 Supports Windows® 95, 98, 2000, XP SP1/SP2 User License (J8758A) Encryption: DES, 3DES, AES 100-user license for IPSec VPN client software ProCurve VPN Client Supports Windows 95, 98, 2000, XP SP1/SP2 Unlimited License Encryption: DES, 3DES, AES (J8750A) Unlimited-user license for IPSec VPN client software Additional accessories ProCurve 600 Redundant External Power Supply J8168A (See the ProCurve Accessories QuickSpec for details.) Services for accessories are covered under the product in which they are installed. © Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. ARM is a registered trademark of ARM Limited. Intel and Pentium are U.S. registered trademarks of Intel Corporation. Microsoft, Windows, and Windows NT are U.S. registered trademarks of Microsoft Corporation. UNIX is a registered trademark of The Open Group. Some product specifications are subject to change. For up-to-date information please visit http://www.hp.com/go/procurve. 5982-4071EN, 05/2005 DA - 12288 North America — Version 1 — June 6, 2005 Page 10