Bruperite Testing Report

  1. 1. Architectural Testing FIELD TEST REPORT Rendered to: BUMPERITE WATERGUARDS, LLC. PROJECT: City of Hope Arnold and Mabel Beckman Building Mockup LOCATION: Duarte, California Report No.: 90353.01-701-43 Set-Up Date: 03/11/09 Test Date: 03/11/09 Report Date: 04/02/09 Revision 1 Date: 05/28/09 4 Rancho Circle Lake Forest, CA 92630 phone: 949-460-9600 fax: 949-460-9601 www.archtest.com
  2. 2. Architectural Testing FIELD TEST REPORT Rendered to: Bumperite Waterguards, LLC. 1560-1 Newbury Road #101 Newbury Park, CA 91320 Report No.: 90353.01-701-43 Set-Up Date: 03/11/09 Test Date: 03/11/09 Report Date: 04/02/09 Revision 1 Date: 05/28/09 Project Identification: City of Hope Arnold and Mabel Beckman Building Mockup Duarte, California Project Summary: Architectural Testing was contracted to perform on-site testing at the above referenced project. One water penetration test was performed on a Bumperite® scaffold tie installed into plaster cement mockup test wall. The specimen tested met the performance requirements listed herein. Test Methods: Tests were conducted in accordance with the following: ASTM E 1105-00, Field Determination of Water Penetration of Installed Exterior Windows, Curtain Walls, and Doors by Uniform or Cyclic Static Air Pressure Difference. (Uniform static air pressure difference was employed during these tests). ASTM E 331-00, Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference Pre-Test Inspection: A visual inspection of the designated test area was performed prior to testing. The test area was compared to adjacent wall sections on the mockup. No obvious deficiencies or anomalies were observed. 4 Rancho Circle Lake Forest, CA 92630 phone: 949-460-9600 fax: 949-460-9601 www.archtest.com
  3. 3. 90353.01-701-43-r1 Architectural Testing Page 2 of 5 Test Procedure: The perimeter of the chamber was attached and sealed to framing members at the interior side of the wall between the studs. The chamber was equipped with a centrifugal vacuum pump, air flow meter, and a pressure sensing device to maintain the desired air pressure differential across the assembly. Water penetration tests were conducted at 15.0 psf pressure differential while simultaneously spraying water on to the exterior face of the assembly at the required rate of 5 gph/ft2. During testing, the interior face of the test area was inspected for water leakage. Testing continued for 15 minutes. The interior wall cavity adjacent to the test specimen was open allowing visual access. Performance Criteria: Provided by Bumperite Waterguards LLC Water Leakage: ASTM E 1105-00: Water penetration shall be defined as penetration of water beyond a plane parallel to the glazing (the vertical plane) intersecting the innermost projection of the test specimen, not including interior trim and hardware under the specified conditions of air pressure difference across the specimen. Any such water penetration shall constitute failure of the water penetration resistance test. It shall also constitute failure if water penetrates through the perimeter frame of the test specimen. Water contained within drained flashing, gutters, and sills shall not be considered failure. ASTM E 331-00: Water penetration is defined as penetration of water beyond the vertical plane intersecting the innermost projection of the test specimen, not including interior trim and hardware, under the specified conditions of air pressure difference across the specimen. Failure also occurs whenever water penetrates through the perimeter frame of the test specimen. Water contained with drained flashing, gutters, and sills is not considered failure.
  4. 4. 90353.01-701-43-r1 Architectural Testing Page 3 of 5 TEST RESULTS Date: 03/11/09 Ambient Exterior Air Temperature: 66oF General Note: All locations referenced are as viewed from the interior unless otherwise noted. Test Specimen #1: (See Photo No.1) Manufacturer: Bumperite Waterguards, LLC. Description: Scaffold tie installed into a cement plaster mockup wall Location: Left side of the mockup, approximately 4 feet high, between the studs Title of Test Test Results Allowable Water Penetration @ 15.0 psf No water leakage No water leakage Witnesses: The following representatives witnessed all or part of the testing: Name Company Logan Archer Bumperite Waterguards, LLC. Octavian Vlagea Architectural Testing, Inc. John Mayfield Architectural Testing, Inc.
  5. 5. 90353.01-701-43-r1 Architectural Testing Page 4 of 5 This report is prepared for the convenience of our customer and endeavors to provide accurate and timely project information. It contains a summary of observations made by a qualified representative of Architectural Testing. This report is intended to help in your Quality Assurance Program, but it does not represent a continuous nor exhaustive evaluation. The statements made herein do not constitute approval, disapproval, certification, acceptance of performance or materials, or an endorsement by this laboratory. It is the exclusive property of the client so named herein and relates only to the specimen(s) tested. A copy of this report will be retained by Architectural Testing for a period of four years from the original test date. At the end of this retention period, this report shall be discarded without notice, and the service life of this report will expire. Results obtained are tested values and were secured by using the designated test methods. This report may not be reproduced, except in full, without the written approval of Architectural Testing. For ARCHITECTURAL TESTING, INC: John Mayfield Blaize Baehrens. Project Manager Project Engineer JM:bu Attachments (pages): This report is complete only when all attachments listed are included. Appendix-A: Photographs (1)
  6. 6. 90353.01-701-43-r1 Architectural Testing Revision Log Rev. # Date Page(s) Revision(s) 0 3/20/09 N/A Original Report 1 5/28/09 1 Changed Test Methods section from ASTM E 331-96 to ASTM E 331-00 1 5/28/09 2 Changed Performance Criteria section from ASTM E 331-96 to ASTM E 331-00 This report produced from controlled document template ATI 00069, revised 10/08/08.
  7. 7. 90353.01-701-43-r1 Architectural Testing APPENDIX A Photographs
  8. 8. 90353.01-701-43-r1 Architectural Testing Photo No. 1: Bumperite® scaffold tie installed into the cement plaster mockup wall

×