SymCom Product Overview           Presented by:           Steve Johnson           Power Quality Asia inc.
Agenda Introductions SymCom Overview Industry Issues Product Overview    Motor Protection    Voltage Monitors    Pu...
Company Overview SymCom was established in 1974 in Rapid City SD The company is a leading engineering and manufacturing ...
SymCom BrandsMotorSaver®                      PumpSaver® Motor Protection                                  Alternating R...
SymCom BrandsMotorSaver®                      PumpSaver® Motor Protection                                  Alternating R...
Popular Protection Products Goal    Detect problems BEFORE damage can occur to     the motor, compressor, pump or other ...
Typical Applications   Air handlers   Conveyor drive   Oil and gas pumps   Elevator drives   Irrigation pumps   Powe...
Industry Issues Voltage      Low Voltage           A long reduction in voltage, for example, the heavy            usage...
Industry Issues• Phase Loss / Phase Reversal   •   Can occur from lightening, down power lines, blown       fuse, wiring e...
Industry Issues  Voltage Imbalance               • Voltage Unbalance                                     • Voltage unbalan...
Protecting These Industries Air Conditioning Industry                                     Industrial Pumping Industry • Ai...
Model 777 Motor Protection        Overview
Overload Relays – Power Monitors 777 Voltage and Current Protection Monitor      The 777 overload relay resides within c...
Model 777        Protects 3-phase motors and pumps from:Underload (Low KW or HP)             Single Phasing (Voltage and...
Model 777 Features Direct Current Readings 2-90 Amps (CT’s not required) Current Reading 90 to 800 Amps with CT’s Alpha...
Model 777 Additional Features Automatic, Semi- Automatic or Manual Reset      # of Restarts After Under load (Manual, 1,...
Model 777 Benefits Extends motors and pump life by offering superior    motor protection.   Helps with troubleshooting a...
777 KW/HPPower Monitor   Overload Relay
Programming the 777The 777 can be programmed from:   a. The front of the 777   b. A remote computer   c. A remote display1...
Programmable ParametersThe Model 777-KW/HP is a fully-programmable electronic overload relay. Analphanumeric LED display p...
Typical 777 Wiring DiagramPhase leads connected  to the primary side of       the contactorCurrent leads pass through th...
Communications Modules
Communications ModulesModbus Network Communications: Most commonly used overall for other PLCs and Scanners Use of any s...
Communications ModulesEthernet Communications Module Compatible (plug and play) with the 777 Plus Series. User configura...
Communications ModulesDeviceNet Network Communications (Most commonly used by Allen Bradley / Rockwell  Automation PLCs a...
Communications ModulesProfibus Network Communications (Most commonly used by Siemens PLCs and  Scanners). Requires use o...
Communications ModulesCIO-MB (for 24V dry contact inputs) / CIO-120-MB (for  120VAC inputs)      Compatible (plug and pla...
Communications ModulesAnalog Network Communications (Most commonly used by network systems requiring scalable analog  inp...
777 Coupled With Remote Monitor 777 coupled with Remote Monitor      An RM2000 remote monitor mounted on the control box...
Model RM-2000
Remote Displays RM2000/RM1000 Monitors vital motor parameters    Voltage, Current, Unbalance, Power, Ground     current ...
RM-2000 Features Liquid crystal display LED’s indicate mode of operation, fault status,    communication status and run ...
Key Features - Benefits1. REAL-TIME 3 LINES VOLTGAGE AND CURRENT        •    This is a real time screen to read if one lin...
Key Features - Benefits7. ACCUMLATIVE HOURS AND ENERGY     •   This displays the accumulative hours of operation (when the...
Key Features - Benefits12. FAULT 2      • This shows the Current Unbalance when a fault occurs along with the        day a...
RM 1000 Remote Display
RM 1000 Features Monitors up to 16 Model 777 devices Easily mounted on the front of a panel Displays current and voltag...
777-KW/HP Competitive Advantages   Under-Power Tripping – Being able to trip on under-power instead of    under-current m...
Voltage Monitor Overview
460 3-Phase MonitorSurface or DIN railmount three phase           Four adjustment potsvoltage monitor with        Voltag...
460 Phase Wiring Diagram
201A-AU 3-Phase Voltage Monitor8 pin plug-in Octal Phase Monitor for 3-Phase Motor protection    Loss of any phase    Lo...
201A-AU Wiring Diagram
201A-AU 3-Phase Voltage MonitorUniversal voltage adjustment       190-480 VAC – 50/60 HzAdjustment knobs allow the user t...
460 & 201A-AU Advantages Universal Voltage – Being able to set our unit to work on voltages from  190-480V means that the...
201 New ProductsModel 201-XXX-DPDTFeatures: Low voltage protection   Single-phase protection   Reverse-phase protection...
455 3-Phase Voltage MonitorMicrocontroller based 3-Phase voltagemonitor that combines load and line sidemonitoring and has...
455 Advantages   Contactor Failure Protection – By having a second set of voltage    inputs to monitor the three legs of ...
Pump Controllers
Pump Controllers SymCom has,     7 models     Control a Single or Multiple pumps     Detect pump seal leaks and/or mot...
PC 102PC-102CICI-DL    Dual seal-leak detector using probes of your choice      and inputs to sense seal failures on pump...
PC 105 PC-105    Five channel pump controller designed to      handle multiple pump applications         Duplex, Triple...
PC-XXX-LLC-GM                                                              New Liquid Level Sensors                       ...
Intrinsically SafeRelays Overview
Intrinsically Safe (IS) Products IS products are considered an “intrinsically safe associated   apparatus.” Our products...
Intrinsically Safe ISS-105 Super Cell PumpSaver ISS-105 IS Super Cell is a  smart, five-channel, intrinsically safe  rela...
Intrinsically Safe ISS-105 Super Cell• The ISS-105 has three adjustable controls to set  the mode of operation.           ...
Intrinsically Safe ISS-105 Super Cell        • Time DelayTime            • The time delay can be set from 2-255 secondsDel...
Intrinsically Safe ISS-105 Super Cell           • Mode Selector Mode         • This dial is used to select the operationSe...
Intrinsically Safe ISS-105 Super Cell Option    • Option SelectorSelector              Hand-out:              http://www.s...
Typical Wiring     Refer to manual for more wire diagrams, etc. - http://www.symcom.com/documentation/inst/pdf/II_ISS-105....
ISS-105 Advantages   Combine multiple products – This unit combines the functions of    an alternating relay (for 2, 3 or...
Intrinsically SafeISS-100 Compact design Finger-safe terminals DIN rail or surface mountable LED state indicator Isol...
Alternating Relays
Alternating RelaysModel ALT alternating relays are used to alternate betweentwo loads. The ALT is commonly used in duplex ...
New Alternating RelaysModel ALT-XXX-1-SW   Features:      Single float input and two isolated Form C       relay outputs ...
Alternating Relays50-400-ALT   480 Volt inputs and relay outputs eliminate the    need for a control power transformer. ...
Load Sensors
LSR-0The Model LSR-0 is a self-powered load sensorintended for use as a proof relay. It is used to verifythat current is f...
LSR-24, -115 & -230The Model LSR-XXX load sensors use current levelsto determine feed rates, tool wear, loss of prime onpu...
LSRUThe Model LSRU is a microcontroller-based family of loadsensors that employ three basic types of control logic:Motor C...
LSRX & LSRX-CThe Model LSRX is an AC current sensordesigned to energize the output contactwhenever 4.5 Amps or greater is ...
Private Label – Custom Designs We design and develop both private label and custom  control products      Our engineerin...
Why SymCom? Over 34 years designing, manufacturing    and testing motor protection and control    equipment   UL/cUL, CE...
SymCom Website SymCom’s website www.symcom.com        Look for products        Download/print catalog                 ...
Upcoming SlideShare
Loading in...5
×

Power Point Presentation For Symcom 2012

809

Published on

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
809
On Slideshare
0
From Embeds
0
Number of Embeds
1
Actions
Shares
0
Downloads
14
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide
  • Current transformer selection guide is in the installation instructions or product brochure. Press the blue reset button to display last fault. 100,000 Amp UL Listing withstand rating allow the units to be installed in any control panel at any time. This enables you to add the unit to a control panel without violating any UL requirements.
  • The 777KW/HP monitors current for full load and and overload conditions. At no load conditions when a motor is lightly loaded because of low or restricted flow through a pump the 777KW/HP acts like a power monitor. This enables the unit to consistently trip at the same selected horsepower value.
  • The units will be factory set for a given motor horsepower. The units will be locked out to prevent any unauthorized tampering of the set points. Parameters can be changed by turning the mode selection dial(yellow) to GF. Turn the (grey) knob fully clockwise and depress the (blue) reset button. While holding the (blue) reset button begin turning the (grey) knob counter clockwise until the display changes from (Loc) to (Unlock)
  • The Model 201A-AU is the newest, most versatile, plug-in style voltage monitor designed to protect 3-phase motors from damaging power conditions. Its wide operating range combined with UL, cUL and CE compliance enables quick access to domestic and global markets.
  • The Model 201A-AU is the newest, most versatile, plug-in style voltage monitor designed to protect 3-phase motors from damaging power conditions. Its wide operating range combined with UL, cUL and CE compliance enables quick access to domestic and global markets.
  • Power Point Presentation For Symcom 2012

    1. 1. SymCom Product Overview Presented by: Steve Johnson Power Quality Asia inc.
    2. 2. Agenda Introductions SymCom Overview Industry Issues Product Overview  Motor Protection  Voltage Monitors  Pump Controllers  Intrinsically Safe Relays  Alternating Relays  Load Sensors Information  Website  Contacts
    3. 3. Company Overview SymCom was established in 1974 in Rapid City SD The company is a leading engineering and manufacturing firm that designs and develops:  Electronic Control and Protection Products  Custom and Private Labeled Products for Major OEMs  The company’s focus is on five (5) main markets:  Industrial Electrical  Fresh Water Pumping  Waste Water Pumping  HVAC/R  Custom OEM Designed, manufactured and tested in the USA
    4. 4. SymCom BrandsMotorSaver® PumpSaver® Motor Protection  Alternating Relays  Motor protection devices  Communication modules  Intrinsically-Safe Relays  Remote monitoring devices  Pump Controllers  Power Monitors  PumpSavers®  Solutions software  3-phase PumpSavers® Voltage Monitors  Single-phase PumpSavers®  3-phase voltage monitors  Load Sensors  Single-phase voltage  Auxiliary Products monitors  Custom OEM Controls Current Monitors  3-phase current monitors  Single-phase current monitors
    5. 5. SymCom BrandsMotorSaver® PumpSaver® Motor Protection  Alternating Relays  Motor protection devices  Communication modules  Intrinsically-Safe Relays  Remote monitoring devices  Pump Controllers  Power Monitors  PumpSavers®  Solutions software  3-phase PumpSavers® Voltage Monitors  Single-phase PumpSavers®  3-phase voltage monitors  Load Sensors  Single-phase voltage  Auxiliary Products monitors  Custom OEM Controls Current Monitors  3-phase current monitors  Single-phase current monitors
    6. 6. Popular Protection Products Goal  Detect problems BEFORE damage can occur to the motor, compressor, pump or other equipment How?  Sense changes in the electrical load and by monitoring the power supply Outcome  Protects motors and pumps against damage caused by dry running, overload, blocked % discharge, etc. n st 63 ts agai of all P rotec causes s! e ut of th r burno moto
    7. 7. Typical Applications Air handlers Conveyor drive Oil and gas pumps Elevator drives Irrigation pumps Power substation monitoring Lift station pumps Water waste and sewage machinery Robotics equipment Computer power protection Sawmill and wood pump machinery Automatic transfer switching for emergency power supplies Commercial/Industrial air conditioning and refrigeration compressors
    8. 8. Industry Issues Voltage  Low Voltage  A long reduction in voltage, for example, the heavy usage of air conditioning during summer could lead to low voltage or brownouts and cause  Equipment shutdowns  Reduced motor torque, increased stalling  Overheating of motors (insulation breakdown)  Tripping of protective devices  High Voltage  Electronic and electrical devices are designed to operate at a certain maximum supply voltage  Considerable damage can be caused by voltage that is higher than that for which the devices are rated
    9. 9. Industry Issues• Phase Loss / Phase Reversal • Can occur from lightening, down power lines, blown fuse, wiring error or contactor failure • This causes motor windings to over heat and prevents the motor from operating at its rated horse power
    10. 10. Industry Issues Voltage Imbalance • Voltage Unbalance • Voltage unbalance - a voltage unbalance between the three phases. Possible causes, • Lines are lost • A tin can transformer is replaced by another model • A contactor becomes wornA power outage, caused byhigh winds, affected 150,000 • A new load is added to one phase of a facility’scustomers in eight counties power systemnorth and east of Houston. Aspokesman with Entergy Texassaid 16 transmission lines were • A slight voltage unbalance causes a significantlost, which caused a voltage temperature increase and causes prematureunbalance and led to theemergency shutdown of a failurepower plant in Willis, about 45miles north of Houston.
    11. 11. Protecting These Industries Air Conditioning Industry Industrial Pumping Industry • Air handling units • Water and petroleum • Rooftop systems • Screw compressors pumping markets • Scroll compressors • Heat pumps Fire pump Control Industry • Chillers • Specialty products used in • Self-contained A/C systems fire pump control panelsMining Industry Submersible Pumping IndustryPump protection, ground faultand monitoring on motors for • Water pumping marketsprotection of• Crushers* Refrigeration Industry• Conveyors • Devices work with existing• Pulverizers*• Pelletizers systems to perform critical*contact factory for applications operational functions
    12. 12. Model 777 Motor Protection Overview
    13. 13. Overload Relays – Power Monitors 777 Voltage and Current Protection Monitor  The 777 overload relay resides within control box and monitors a motor.  Protects any 3-Phase motor drawing 2-800 amps.  Multi ranging voltage 190-480 VAC.  UL listed, CSA recognized and CE approved,  UL - UL508, UL1053  CE - IEC 60947-1, IEC 60947-5-1  CSA - C22.2 Popular Features  Low Power Protection  Current unbalance  Over Current protection  Voltage unbalance  Single/Reverse Phase  Ground fault  High Voltage  Low Voltage
    14. 14. Model 777 Protects 3-phase motors and pumps from:Underload (Low KW or HP) Single Phasing (Voltage and Current)High Power Unbalance (Voltage andOverload (UL Listed) Current) Trip Classes: 5, 10, 15, 20, 30 Ground Fault (Class 2)Jams Contact FailureUnder voltage (Brownout) Rapid CyclingOvervoltage (6PM Syndrome) Phase Reversal
    15. 15. Model 777 Features Direct Current Readings 2-90 Amps (CT’s not required) Current Reading 90 to 800 Amps with CT’s Alphanumeric LED Diagnostic Display  Last Fault  All 3 Line-Line Voltages  All 3 Phase Currents  Real-time KW or HP Last Four Fault Memory Fully programmable – Onboard or via S/W Tamper guard 100 KA Withstand Rating UL Listed, CSA Approved, CE compliant
    16. 16. Model 777 Additional Features Automatic, Semi- Automatic or Manual Reset  # of Restarts After Under load (Manual, 1, 2, 3, 4, Always)  # of Restarts After Faults (Manual, 1, 2, 3, 4, Always) Automatic Dry Well Recovery Calculator (Auto Compensates for “Dry” vs. “Wet” Periods) RS485 communications port (ModBus/DeviceNet/ProfiBus/ENet) View Data from Remote Monitor (RM1000 or RM2000 or PC) Addressable – Up to 99 Units per Network Protocol Manual Available (Interface to PLC, SCADA, DCS, PC) 5 Year Warranty Made in USA
    17. 17. Model 777 Benefits Extends motors and pump life by offering superior motor protection. Helps with troubleshooting adverse conditions without having to change out a damaged motor or pump. Reduces arc flash hazards when remote monitors are used. Allows the user to monitor, diagnose, and control motors remotely. Reduce warranty replacement costs Economical motor and pump protection Saves time troubleshooting motor and pump problems.
    18. 18. 777 KW/HPPower Monitor Overload Relay
    19. 19. Programming the 777The 777 can be programmed from: a. The front of the 777 b. A remote computer c. A remote display1. Rotate the MODE SELECT switch to the parameter to be programmed2. Depress and hold the RESET/PROGRAM button3. Rotate the DISPLAY/PROGRAM screw to the desired setting as shown in the LED display and4. Release the RESET/PROGRAM buttonUnit can be locked-out to prevent unauthorized tampering of set-points
    20. 20. Programmable ParametersThe Model 777-KW/HP is a fully-programmable electronic overload relay. Analphanumeric LED display provides programming and diagnosticinformation. Sixteen parameters can be programmed in the Model 777-KW/HP:1. Low voltage set point 9. Rapid Cycle Timer (RD1)2. High voltage set point 10. Overload Restart Delay (RD2)3. Voltage unbalance set point 11. Under power Restart Delay (RD3 - Dry Well Recovery Timer)4. CT size/loop setting 12. # of restarts after an under load (Manual, Semi-Automatic or Automatic)5. Over current trip point 13. RS485 Address6. Low Power trip point 14. # of restarts after Faults other than ULoad7. Current unbalance trip point 15. KW or HP Range Table8. Trip class (5,10,15,20,30,Jam) 16. Ground Fault Trip Point
    21. 21. Typical 777 Wiring DiagramPhase leads connected to the primary side of the contactorCurrent leads pass through the built in CT’sNO Contact connected in the control circuitNC Contact connected to an alarm circuit.
    22. 22. Communications Modules
    23. 23. Communications ModulesModbus Network Communications: Most commonly used overall for other PLCs and Scanners Use of any standard 777 series or 777 Plus series Power Monitor/Overload Relay, or 601 Voltage Monitor (limited communications with the 777-Accupower when 4-20 mA communications module is not used). Requires use of the following communications module:  RS485MS-2W Communications Module Modbus RTU over RS485 two wire connection. No external power source required for unit operation. Will communicate with RM-1000 or RM-2000 Remote Monitors* Will communicate with Solutions-M Software (can be used, but not required).* NOTE: at this time the RM-1000 and RM-2000 are not able to communicate with the LR versions of the 777 Plus series when configured with external current transformers, or the P1 versions of the 777 Plus series. (RM unit updates available soon.)
    24. 24. Communications ModulesEthernet Communications Module Compatible (plug and play) with the 777 Plus Series. User configurable to work with the standard 777 series and the 601. Requires use of the following items:  777 Plus series Power Monitor/Overload Relay.  CIO-EN Communications Module.  24VDC source required for unit operation. Modbus RTU over RS485 two wire connection. Modbus TCP over Ethernet cable. Will communicate with RM-1000 or RM-2000 Remote Monitors* Will communicate with Solutions-M Software (can be used, but not required).* NOTE: at this time the RM-1000 and RM-2000 are not able to communicate with the LR versions of the 777 Plus series when configured with external current transformers, or the P1 versions of the 777 Plus series. (RM unit updates available soon.)
    25. 25. Communications ModulesDeviceNet Network Communications (Most commonly used by Allen Bradley / Rockwell Automation PLCs and Scanners). Requires use of the following items:  777 Plus series Power Monitor/Overload Relay.  CIO-DN-P Communications Module (for 24V dry contact inputs), or CIO-120-DN-P Communications Module (for 120VAC inputs). 24VDC source required for unit operation. Will not communicate with RM-1000 or RM-2000 Remote Monitors. Will communicate with Solutions-D Software (can be used, but not required).
    26. 26. Communications ModulesProfibus Network Communications (Most commonly used by Siemens PLCs and Scanners). Requires use of the following items:  777 Plus series Power Monitor/Overload Relay.  CIO-777-PR Communications Module.  24VDC source required for unit operation. Will not communicate with RM-1000 or RM-2000 Remote Monitors. Will not communicate with Solutions Software.
    27. 27. Communications ModulesCIO-MB (for 24V dry contact inputs) / CIO-120-MB (for 120VAC inputs)  Compatible (plug and play) with the 777 Plus series  User configurable to work with the standard 777 series and the 601.  Modbus RTU over RS485 two wire connection.  24VDC source required for unit operation.
    28. 28. Communications ModulesAnalog Network Communications (Most commonly used by network systems requiring scalable analog inputs, i.e. PLCs, SCADA or data recorders). Requires use of the following items:  777-Accupower Power Monitor/Overload Relay.  Com 4-20mA Communications Module.  Module output pertains to motor shaft power scaled at 4-20 mA.  No external power source required for unit operation. Will not communicate with RM-1000 or RM-2000 Remote Monitors (when 4-20 mA module is used). Will not communicate with Solutions-M Software when 4-20 mA module is used.
    29. 29. 777 Coupled With Remote Monitor 777 coupled with Remote Monitor  An RM2000 remote monitor mounted on the control box door displays critical information and allows changes to set points on the 777 without having to expose one to the hazards of arc flash.  The RM2000-RTDW will accept up to 8 RTD inputs.  The RM1000 could monitor up to 16 units.
    30. 30. Model RM-2000
    31. 31. Remote Displays RM2000/RM1000 Monitors vital motor parameters  Voltage, Current, Unbalance, Power, Ground current  Limits exposure to ARC Flash Hazards by having information displayed on outside of MCC cabinet. Displays last 4 motor fault information  (RM 2000 records voltages and currents values at time of fault) Program the 777 remotely Allows for remote reset
    32. 32. RM-2000 Features Liquid crystal display LED’s indicate mode of operation, fault status, communication status and run status Easily mounted on the front of a panel and rated for environmental protection (NEMA 3R) Stores motor history information with date and time stamp Can be mounted up to 4000 ft. from the motor starter Second communication port is standard
    33. 33. Key Features - Benefits1. REAL-TIME 3 LINES VOLTGAGE AND CURRENT • This is a real time screen to read if one line is out of balance.2. REAL-TIME 3 CURRENT LEVELS • Currents on lines 1, 2 & 3 with average between the three lines displayed.3. REAL-TIME 3 VOLTGAGE LEVELS • Incoming voltage levels on Lines 1-2, 2-3 and 3-1 with average between the three lines displayed.4.CURRENT & VOLTGAGE UNBALANCE • Indicates the unbalance percentage of the current the motor is running at and the incoming line voltage.5. RESTART DELAY TIMERS • This display shows the time left to reset, if the 777 has tripped on a fault6. GROUND FAULT CURRENT AMPS • Displays the amount of ground fault, in amps. This helps guard against ground faults that could lead to premature motor failure overtime.
    34. 34. Key Features - Benefits7. ACCUMLATIVE HOURS AND ENERGY • This displays the accumulative hours of operation (when the motor is running) and the energy used in KW hours. This screen feature helps one to schedule maintenance for the motor and/or driven equipment.8. # OF FAULTS AND # OF TRIPS • This display feature shows the number of actual starts the motor has had and the number of times the unit tripped on a current fault.9. VOLTAGE, CURRENT, POWER FACTOR • This screen shows the average of the voltage and current and power factor.10.POWER CONSUMTION • The actual power consumption is displayed as well as the KVARS.11. PENDING FAULT • This screen will ‘pop up’ and display at anytime when a pending fault problem may be occurring. The unit displays multiple fault indications such as Voltage and Current unbalance, etc. and captures relevant data like date and time.
    35. 35. Key Features - Benefits12. FAULT 2 • This shows the Current Unbalance when a fault occurs along with the day and time the fault occurred.13. FAULT 2 was a CURRENT UNBALANCE • This display indicates the current levels at the time of the fault. If we did the math, we would see that the unbalance was at 23%. We had our CUB set at 10% and #RF at 0. We determined that we had a faulty contactor, thus we stopped a current single phase from burning up the motor. 14. FAULT 2 • This screen shows that at the time of the fault, we had .09A of ground fault current, which will happen when you have a current unbalance. 15. FAULT 2 • This screen shows that the voltages at the time of the fault were balanced, so the fault was on the load side of the contactor. 16. FAULT 2 • This screen displays the voltage unbalance (0%) and the average voltage for the unit. 17. FAULT 2 • This screen displays the current unbalance (0%) and the average current for the unit.
    36. 36. RM 1000 Remote Display
    37. 37. RM 1000 Features Monitors up to 16 Model 777 devices Easily mounted on the front of a panel Displays current and voltages Displays fault condition Remote reset of MotorSaver/PumpSaver Standard communication port Displays run hours on each motor
    38. 38. 777-KW/HP Competitive Advantages Under-Power Tripping – Being able to trip on under-power instead of under-current means a more accurate and faster trip – meaning better protection to the motor. This is particularly advantageous to pumps where their running dry can cause pump damage. Most of our competition trips on under-current only, or does not offer under-current tripping at all. Advanced Motor Protection Affordably – This unit provides motor protection from the primary causes of damage due to electrical issues. These include voltage, phase, current and ground fault monitoring. In addition it provides a display for monitoring voltage & current and communications to monitoring systems. Most of our competition offering these protection features are at MUCH higher price points (often 3 to 5 times our price or more). Multiple Communication Options – When the user wants to monitor their motors/pumps via SCADA or other software, this unit provides multiple protocols to make integration easy. These include Modbus RTU, Profibus, DeviceNet, and Ethernet Modbus TCP. Most of our competition offers no communications or perhaps only 1 or 2 of these options. Networking: Up to 99 units can be networked together and 16 units can be on a sub-network via one remote monitor.
    39. 39. Voltage Monitor Overview
    40. 40. 460 3-Phase MonitorSurface or DIN railmount three phase  Four adjustment potsvoltage monitor with  Voltage Adjustmentself-adjustments.  Restart in seconds  Adjustable Trip delay Loss of any phase  Voltage Unbalance Delay Low and High voltage  LEDs indicate trip status Voltage unbalance and make trouble Phase reversal shooting a snap. Rapid cycling  Microcontroller based Adjustable Trip and circuitry provides better Restart delay accuracy and higher reliability than analog designs.
    41. 41. 460 Phase Wiring Diagram
    42. 42. 201A-AU 3-Phase Voltage Monitor8 pin plug-in Octal Phase Monitor for 3-Phase Motor protection  Loss of any phase  Low voltage  High voltage  Voltage unbalance  Phase reversal  Rapid cycling  Adjustable Trip and Restart delay  UL508 and IEC 60947-6-2 Bi-colored LED Indicator
    43. 43. 201A-AU Wiring Diagram
    44. 44. 201A-AU 3-Phase Voltage MonitorUniversal voltage adjustment  190-480 VAC – 50/60 HzAdjustment knobs allow the user to set  1-30 sec trip delay  1-500 second restart delay  2-8% voltage unbalance trip pointBi-colored LED indicates trip status Protecting an Elevator within the Control Box  This microcontroller-based voltage and phase-sensing device constantly monitors the 3-phase voltages to detect harmful power line conditions.
    45. 45. 460 & 201A-AU Advantages Universal Voltage – Being able to set our unit to work on voltages from 190-480V means that the user only needs to worry about 1 unit type for replacement purposes on both 230V and 460/480V applications, the local distributor only needs to keep 1 on the shelf, the service techs only need to have 1 unit type on their truck, etc. Most of our competition requires two separate units for these different voltage ranges. Diagnostic LED – instead of just telling the user that the unit has tripped, we help the user determine the cause of trip so that they can solve the problem. Most of our competition only tells you that the unit has tripped, but not why. More User Adjustability – Different applications and installation sites can have unique issues. Being able to adjust the trip delay, restart delay and trip set point for the voltage unbalance means the end user can set these for that location’s unique needs. Most of our competition has fixed set points for these things. No line-side fuses required – Our units are UL approved without the requirement for line-side fuses to protect our unit. Most of our competition require these fuses, which adds further cost to the project.
    46. 46. 201 New ProductsModel 201-XXX-DPDTFeatures: Low voltage protection Single-phase protection Reverse-phase protection Voltage unbalance protection Two isolated Form C relays (DPDT) Diagnostic LED UL508 Listed CE Marked 11-pin plug in; DIN rail or surface mount Model 201-XXX-SP-DPDT Features:  Low voltage protection  Two isolated Form C relays (DPDT)  Diagnostic LED  UL508 Listed  CE Marked  8-pin plug in; DIN rail or surface mount
    47. 47. 455 3-Phase Voltage MonitorMicrocontroller based 3-Phase voltagemonitor that combines load and line sidemonitoring and has an infrared LED tocommunicate with the Informer.  Motor will not start when a power problem is present  Rapid cycling by monitoring contactor or starter  Loss of any phase (single-phasing) on the load or line side  Low and high voltage  Voltage unbalance (adjustable)  Phase reversal 455 list price is $223.17
    48. 48. 455 Advantages Contactor Failure Protection – By having a second set of voltage inputs to monitor the three legs of voltage between the contactor and the motor, the 455 is able to sense and trip on unbalanced voltage being caused by wearing contacts on the contactor. This unbalanced voltage over time will cause damage to the motor, and as the contacts continue to wear they can eventually fail and cause a single phase condition, which will quickly burn up motors. Most of our competition does not offer this protection feature. Fault History Memory – This unit keeps a history of the past 20 fault causes, including voltage and unbalance at the time of trip. By using our Informer-MS service technicians can easily determine why the unit has been tripping, and solve the problem. This is particularly valuable for motors/pumps that are in remote locations where there is no personnel on-site to see the unit’s LED to determine trip cause. Most of our competition does not have this fault history capability.
    49. 49. Pump Controllers
    50. 50. Pump Controllers SymCom has,  7 models  Control a Single or Multiple pumps  Detect pump seal leaks and/or motor overheating on submersible pumps.  Five-channel pump controller available Model Description PC-102CICI-DL Dual seal-leak detector PC-102CICI-LT Seal-leak and over-Temperature detector PC-105 Five-channel pump controller 201-100-SLD Plug-in seal leak detector 460-15-100-SLD Din rail or surface mountable Seal leak detector 460-15-100-LLS Din rail or surface mountable Liquid level sensor PC-XXX-LLC Plug-in Liquid Level Sensor
    51. 51. PC 102PC-102CICI-DL  Dual seal-leak detector using probes of your choice and inputs to sense seal failures on pumpsPC-102CICI-LT  Seal leak and over-Temperature detector to sense seal failures or motor overheating and configurable for using probes of your choice.  Both units have two form-C isolated output relays and two LEDs which illuminate when each associated output relay is energized.
    52. 52. PC 105 PC-105  Five channel pump controller designed to handle multiple pump applications  Duplex, Triplex, Quadplex pump modes  Pump Up or Pump Down functions  Alternating, non-alternating or jockey/emergency pump.  Built-in dip switches allow for individual pumps to be disabled when taken out of service for repair or maintenance. Keep Water Level Low Treatment plant Typical Wiring for a Duplex Pump Down
    53. 53. PC-XXX-LLC-GM New Liquid Level Sensors GEMS P/N SymCom P/N The LLC-GM is “compatible” with the Gems 16MA1A0 PC-100-LLC-GM Series 16M as opposed a different word (like 16MB1A0 PC-100-LLC-GM equivalent to) because we don’t replace every unit in their 16M series. This is primarily 16MC1A0 PC-100-LLC-GM because we only offer an adjustable 4.7K- 16MD1A0 PC-100-LLC-GM 100K sensitivity range and two voltage ranges 16ME1A0 PC-100-LLC-GM (95-120 and 190-240), and we avoided the 16MA2A0 PC-200-LLC-GM time delay options other than a fixed 2 second 16MB2A0 PC-200-LLC-GM debounce trip delay time. 16MC2A0 PC-200-LLC-GM 16MD2A0 PC-200-LLC-GMWe cross to their 120v and 230v products, and we have the 16ME2A0 PC-200-LLC-GMsensitivity range from 4.7k to 100k, so we support the A-E and K-P 16MK1A0 PC-100-LLC-GMversions. They sell their controls with a fixed probe sensitivity. 16ML1A0 PC-100-LLC-GMA=4.7k, B=10k, C=26k…E=100k for what we would call pump- 16MM1A0 PC-100-LLC-GMdown operation, and K=4.7k, L=10k…etc. for pump-up operation. 16MN1A0 PC-100-LLC-GMOur LLC products allow pump-up or pump-down to be selected 16MP1A0 PC-100-LLC-GMusing the pot, as well as the sensitivity setting. 16MK2A0 PC-200-LLC-GMEssentially this means that our 2 units can 16ML2A0 PC-200-LLC-GM 16MM2A0 PC-200-LLC-GMreplace 20 of theirs due to our units adjustability. 16MN2A0 PC-200-LLC-GM 16MP2A0 PC-200-LLC-GM
    54. 54. Intrinsically SafeRelays Overview
    55. 55. Intrinsically Safe (IS) Products IS products are considered an “intrinsically safe associated apparatus.” Our products can be applied to the most hazardous environments, but the electronics must be located in a “nonhazardous” location. Essentially, we can run the IS wiring to the hazardous locations, but the electronics must either be located in a panel that is not in the hazardous area, or in an explosion proof enclosure in the hazardous area. We supply control drawings with each product that add clarity for an application. Various Models and the list price ranges from $169 up to $670
    56. 56. Intrinsically Safe ISS-105 Super Cell PumpSaver ISS-105 IS Super Cell is a smart, five-channel, intrinsically safe relay and pump controller. The unit can operate as an intrinsically safe pump control for eight different pumping configurations. Features include,  High, low and out-of-sequence alarms  Variable time delay/lag pump delay PumpSaver  Separate pump stop ISS-105  Pump alternation w/ or w/out non-alternating Super Cell  pump  Duplex, triplex or quadplex pump modes  Pump up or pump down functions  External silence, reset and alternation  configuration  Five-channel relay
    57. 57. Intrinsically Safe ISS-105 Super Cell• The ISS-105 has three adjustable controls to set the mode of operation. Time Mode Option Delay Selector Selector
    58. 58. Intrinsically Safe ISS-105 Super Cell • Time DelayTime • The time delay can be set from 2-255 secondsDelay and is the lag pump delay in each of the pumping modes. • When the lead float opens/closes, the time delay starts and once it expires, the lag pump is ready to turn on. • After the lag pump turns on, any necessary pumps will turn on successively after a two- second time delay each.
    59. 59. Intrinsically Safe ISS-105 Super Cell • Mode Selector Mode • This dial is used to select the operationSelector mode. Hand-out: http://www.symcom.com/documentation/inst/pdf/II_ISS-105.pdf
    60. 60. Intrinsically Safe ISS-105 Super Cell Option • Option SelectorSelector Hand-out: http://www.symcom.com/documentation/inst/pdf/II_ISS-105.pdf
    61. 61. Typical Wiring Refer to manual for more wire diagrams, etc. - http://www.symcom.com/documentation/inst/pdf/II_ISS-105.pdfTypical Wiring for a Duplex Typical Wiring for a Triplex Typical Wiring for aPump Down Pump Down Quadplex Pump Down
    62. 62. ISS-105 Advantages Combine multiple products – This unit combines the functions of an alternating relay (for 2, 3 or 4 pump systems), intrinsically safe switches, and other associated relays. No other competitive product offers all this functionality in 1 unit. Reduce panel size – By combining all these products into one, less panel space is needed for components. A smaller panel size means cost savings. Reduce production/wiring time – combining these components means less things to wire up, which means less time spent per panel. This means labor savings and quicker turn-around time on panel production. IS products meet the 6th edition of UL913. Many products that are being sold today only meet an earlier version of the standard.
    63. 63. Intrinsically SafeISS-100 Compact design Finger-safe terminals DIN rail or surface mountable LED state indicator Isolated output relay for PLC or control voltageISS-101 Compact design LED state indicator DIN rail or surface mountable via common octal-base package Pop-in replacement for other manufacturers’ parts Isolated output relay for PLC or control voltageISS-102 Compact design Finger-safe terminals DIN rail or surface mountable Two LED state indicators Two-channel, intrinsically-safe switch or multi-function controller Pump-up/pump-down (latching) controller
    64. 64. Alternating Relays
    65. 65. Alternating RelaysModel ALT alternating relays are used to alternate betweentwo loads. The ALT is commonly used in duplex pumpingapplications to balance the runtime of both pumps.  Two LEDs indicate the energized load.  Can be ordered with a switch to manually  override the system.  Three choices of input voltage provide the  versatility needed to handle global applications.  Can be ordered with a standard SPDT relay or with cross connected relays. Debounce time delay prevents nuisance tripping Features: caused by float switches.  Alternates between two loads  Solid-state reliability  Compact size  Debounce time delay  SPDT or cross connected  Optional manual/auto mode switch
    66. 66. New Alternating RelaysModel ALT-XXX-1-SW Features:  Single float input and two isolated Form C relay outputs (DPDT)  Debounce time delay (1 second)  LED load indicators  Built-in switch to manually force a specific load (pump) to operate  UL508 listed, CE marked  11-pin plug in; DIN rail or surface mount Model ALT-XXX-3-SW Features: Three float inputs (lead, lag, stop) Debounce time delay (1 second) LED load indicators Built-in switch to manually force a specific load (pump) to operate UL508 listed, CE marked 8-pin plug in; DIN rail or surface mount
    67. 67. Alternating Relays50-400-ALT 480 Volt inputs and relay outputs eliminate the need for a control power transformer. Bi-color LED indicates the energized load. Compatible with single and dual float applications. Debounce time delay prevents nuisance tripping caused by float switches. Additional features:  UL listed  Alternates between two loads  Solid-state reliability  Compact size  Debounce time delay  Compatible with single or dual float applications 600VAC control contacts  10 amp general purpose relay rating
    68. 68. Load Sensors
    69. 69. LSR-0The Model LSR-0 is a self-powered load sensorintended for use as a proof relay. It is used to verifythat current is flowing as intended. It has aguaranteed 15A pull-in current and 2.5A drop-outcurrent. Proof relays are typically used to interlockfans, compressors, motors, heating elements andother devices. The LSR-0 is self-powered, that is, itdraws its power from the wire being monitored so itdoes not require separate control power wiring.
    70. 70. LSR-24, -115 & -230The Model LSR-XXX load sensors use current levelsto determine feed rates, tool wear, loss of prime onpumps, mixer viscosity and all types of overload andunderload conditions. They may also be used to stagepump motors, chillers and other machinery. Thesedevices combine a current transformer (CT) with FormC (SPDT) relay contacts to switch alarm circuits,contactors or any resistive or inductive load. Onesimple screwdriver adjustment will calibrate the sensorfor all single-phase or 3-phase applications up to Switches loads based100hp. on current level changes associated with: •Motor failure •Belt loss •Broken shaft •Bearing failure •Heating element failure •Load loss on fans or pumps
    71. 71. LSRUThe Model LSRU is a microcontroller-based family of loadsensors that employ three basic types of control logic:Motor Control LogicCombinations of functions including overcurrent and undercurrentor either overcurrent or undercurrent with variable trip, restart orextended restart delay settings.Alarm LogicThe LSRU-AL simply indicates whether the current is betweenthe setpoints or outside of the setpoints.Feed ControlThe LSRU-FC is a load monitor intended to control feedermechanisms in a variety of applications. It stops the feeder whenthe grinder, chipper, saw, auger, etc. nears overload.
    72. 72. LSRX & LSRX-CThe Model LSRX is an AC current sensordesigned to energize the output contactwhenever 4.5 Amps or greater is present. TheLSRX is used commonly as an AC current proofrelay to indicate if a motor is operating. It canalso be used to interlock fans, compressorsand motors; to indicate equipment status suchas feed rates, tool wear, loss of prime on pumps,mixer viscosity and all types of current sensingconditions or to stage pump motors, chillers, or Compact design saves precious panelother machinery. space. Relay contacts can switch up to 480VA @ 240VAC, 5A continuous. Unique LED indicator gives clear visual status of relay state. Fast-on terminals or optional depluggable screw terminals ensure quick, simple connections. Requires no external power, power is induced from the AC conductor.
    73. 73. Private Label – Custom Designs We design and develop both private label and custom control products  Our engineering expertise becomes an extension of your companies engineering team for control and protection needs.  From the initial design scope through final assembly, we have world- class engineering, manufacturing, and project management.  All aspects are in-house from Engineering and PCB design, SMT assembly, and final test for beta, small and large runs.  Our Quality is unparalleled in the industry. This is easily demonstrated within the current SymCom product line where the product warranty is five-years.  We build many private label and custom controls for various companies and could discuss these upon request.
    74. 74. Why SymCom? Over 34 years designing, manufacturing and testing motor protection and control equipment UL/cUL, CE, CSA certified products Technical Support is staffed by Technical Engineers to answer all your calls and emails 5-year product warranty All products are designed, manufactured and 100% tested in the USA.
    75. 75. SymCom Website SymCom’s website www.symcom.com  Look for products  Download/print catalog Each product you can download:  Contact us • Product Specs • Installation Bulletins • Engineering Specs  Find a distributor