Agenda
1) Introduction to Eaton
2) The impact of power outages
3) Why Ea...
3
3© 2010 Eaton Corporation. All rights reserved.
Introduction to Eaton
We help the world use electrical, fluid and mechan...
4
4© 2010 Eaton Corporation. All rights reserved.
Introduction to Eaton
Fun facts
• One of the largest companies few have ...
5
5© 2010 Eaton Corporation. All rights reserved.
Introduction to Eaton
Growth
through
acquisitions
Have you used these br...
6
6© 2010 Eaton Corporation. All rights reserved.
Power outages can impact anyone
1. Amazon.com – Ashburn, VA – 6/10/09
2....
7
7© 2010 Eaton Corporation. All rights reserved.
The impact of power outages
Total number of people affected by outages 1...
8
8© 2010 Eaton Corporation. All rights reserved.
Battery backup solutions should be
attached to all plugged in IT equipme...
9
9© 2010 Eaton Corporation. All rights reserved.
Let’s review: A UPS is…
An uninterruptible power system (UPS) is defined...
10
10© 2010 Eaton Corporation. All rights reserved.
The impact of power outages
What challenges
do YOU see with
UPSs?
11
11© 2010 Eaton Corporation. All rights reserved.
The impact of power outages
What challenges
do YOU see with
UPSs?
12
12© 2010 Eaton Corporation. All rights reserved.
They…
• Waste valuable space: Battery backup solutions should not take...
13
13© 2010 Eaton Corporation. All rights reserved.
Eaton solutions…
…solve many of the challenges seen in other backups.
...
14
14© 2010 Eaton Corporation. All rights reserved.
Leading energy efficiency
• Leading efficiency for UPSs
• UPSgrade rec...
15
15© 2010 Eaton Corporation. All rights reserved.
Simplified manageability
• Leading software solutions
• vCenter™ Serve...
16
16© 2010 Eaton Corporation. All rights reserved.
The three building blocks of power
management
Connectivity
Ethernet
We...
17
17© 2010 Eaton Corporation. All rights reserved.
Intelligent Power Software Suite simplifies power
management, even in ...
18
18© 2010 Eaton Corporation. All rights reserved.
Intelligent Power Manager
• View similar devices and all alerts from a...
19
19© 2010 Eaton Corporation. All rights reserved.
Superior reliability
• Leading warranty – three years, including batte...
20
20© 2010 Eaton Corporation. All rights reserved.
Innovative designs
• More power in less U space
• Scalable/redundant m...
21
21© 2010 Eaton Corporation. All rights reserved.
The BladeUPS solution
The BladeUPS® solution is a
highly flexible UPS ...
22
22© 2010 Eaton Corporation. All rights reserved.
The BladeUPS solution – data center solution
Decentralized output dist...
23
23© 2010 Eaton Corporation. All rights reserved.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
2...
24
24© 2010 Eaton Corporation. All rights reserved.
Dedicated support
• #1 presales support
• 95%+ service plan satisfacti...
25
25© 2010 Eaton Corporation. All rights reserved.
Eaton power quality solutions
Single-phase UPS
Workstation, home A/V, ...
26
26
Standby
Line-interactive‡
OnlineLargeonlineOtherproducts
‡Not shown here: Nova AVR® UPS (600–1100 VA), Eaton 5115 To...
27
27© 2010 Eaton Corporation. All rights reserved.
Comparing Eaton core VA points
Eaton
• Product – 5130 1500 VA
• Price ...
28
28© 2010 Eaton Corporation. All rights reserved.
ePDU Power and Function
Basic –
Input plug and receptacles
Monitored –...
29
29© 2010 Eaton Corporation. All rights reserved.
Remote
Power Panel
(RPP)
Power
Distribution Unit
(PDU) Large UPS
Input...
30
30© 2010 Eaton Corporation. All rights reserved.
How it all comes together
31
31© 2010 Eaton Corporation. All rights reserved.
Take advantage of Eaton resources
Eaton pre-sales support: 800.356.579...
32
32© 2010 Eaton Corporation. All rights reserved.
Upcoming SlideShare
Loading in …5
×

Power Protection and Management from the Desktop to the Data Center - Keith Woodley, Eaton

3,215 views

Published on

Power Protection and Management from the Desktop to the Data Center - Keith Woodley, District Sales Manager, Eaton

Published in: Technology, Business
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
3,215
On SlideShare
0
From Embeds
0
Number of Embeds
6
Actions
Shares
0
Downloads
46
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide
  • There are companies that generate power. And others that deliver it. But Eaton is different: We help companies like yours manage power.
  • In fact, Eaton is a leading diversified power management company. We help the world use electrical, fluid and mechanical power more reliably, efficiently and safely. Founded in 1911 Chairman and CEO – Alexander M. Cutler World Headquarters in Cleveland, Ohio, USA Regional Headquarters in Shanghai, China; Morges, Switzerland; Mexico City, Mexico Innovation Centers in the USA, China and India 55% of sales outside the U.S. To demonstrate how we’re expanding our global reach, take a look at our financial highlights. In 2009, fully 42 percent of the Electric Sector’s revenue was generated in Europe, the Middle East, Africa and the Asia Pacific region. As we continue to grow as a multinational corporation, we maintain our commitment to local presence and customer support.
  • Something else you should know: Everywhere Eaton does business, we’re committed to doing business right … from the ethical standards of our people, to the environmental stewardship of our facilities, to the local support we provide to the communities in which we live and work. Eaton has numerous awards. Most recently this week -- Each year, NEWSWEEK Magazine ranks the biggest publicly traded companies in developed and emerging world markets.  For 2010, Eaton ranked #16 overall on the Green Rankings list and #1 in the General Industrials category.  This is an improvement over 2009, were we ranked 43 overall and 3rd  in our category. http://www.newsweek.com/2010/10/18/green-rankings-us-companies.html  Others include: Ranked in the top 10 percent of the inaugural Newsweek ranking of “The Greenest Big Companies in America” One of five companies selected by Barron’s for its “Green Dream Team” Honored among Ethisphere Institute’s “World’s Most Ethical Companies” for fourth consecutive year Ranked among Corporate Responsibility Officer magazine’s “100 Best Corporate Citizens” Cited in China’s Business Watch magazine’s Green Company Top 50 and Fast Company Top 100
  • So what is driving Eaton’s growth and customer loyalty. It is our commitment to designing and delivering solutions that deliver the most efficient solutions. We do this by offering solutions that: Lead the industry in energy efficiency – driving down electricity costs and heat Provide sophisticated, yet simple power management capabilities – that easily integrate into virtualized environments and MSP Platforms Offer Superior Reliability and Industry leading warranties – to keep your maintenance and support costs down Are designed for easy management and scalability - allowing customers to buy what they need today and grow into tomorrow And Come with industry recognized pre and post sales support. Bottom line, our products are designed to deliver efficient uptime for even your most complex environments. This drives down the total cost of ownership.
  • Eaton technology alliances… 1st to Announce Windows 7 Compatibility Eaton’s software family, including Intelligent Power Manager, Intelligent Power Protector, NetWatch, Network Shutdown Module, Personal Solution-Pac and LanSafe®, allows Windows 7 enterprise servers, small business and home-use personal computers (PCs) to be monitored and safely shut down during a power failure, protecting and saving valuable data. 1st to announce VMware ESXi 4.0 compatibility Eaton is the first power management company to offer shutdown compatibility with VMware’s ESXi 4.0 host server virtualization software. 1st to Certified Power Provider Eaton is the first power management company to be named certified power partner for Level Platforms Eaton NetWatch Client 5.0 has tested compatible with Cisco Unified Communications Manager 4.3. Go to www.eaton.com/PQ/cisco for disclaimer. First Certified Power Partner for Level Platforms Eaton compatibility with N-able’s N-Central Integration modules under development for other top managed services platforms
  • Here’s the basic breakdown of Eaton’s Power Management components or “building blocks”. The first component is the “connectivity” or the connection of the Eaton device to the network. This connectivity can be accomplished in a number of ways and we’ll take a deeper dive into the specific methods. Another building block is the supervision and administration functionality for Eaton UPSs and ePDUs. This includes load monitoring, device status, notifications, environmental monitoring, remote outlet control and much more. Protection is one of the most valuable functions of power management. This involves the ability to maximize uptime through sophisticated power management controls and to perform an orderly, graceful shutdown of applications, operating systems and ultimately hardware during extended power outages, in even complex network environments. This also includes the ability to restart equipment in an orderly fashion when power returns.
  • From the building service entrance to the individual server, Eaton Power Quality has the hardware, software, and services that make up the power infrastructure of the data center. We call it the PowerChain. From the modest single-server, small / medium business applications, to enterprise-class data center hardware, Eaton Power Quality has a right-sized solution for the opportunity. Let’s take a look at the portfolio in brief.
  • Power Protection and Management from the Desktop to the Data Center - Keith Woodley, Eaton

    1. 1. © 2008 Eaton Corporation. All rights reserved. Who is Eaton? Welcome 2010 Spiceworld Attendees! October 21-22, 2010
    2. 2. 2 2© 2010 Eaton Corporation. All rights reserved. Agenda 1) Introduction to Eaton 2) The impact of power outages 3) Why Eaton solutions? 4) Eaton product overview 5) Questions?
    3. 3. 3 3© 2010 Eaton Corporation. All rights reserved. Introduction to Eaton We help the world use electrical, fluid and mechanical power more reliably, efficiently and safely • Founded in 1911 • Chairman & CEO: Alexander M. Cutler • Headquarters: Cleveland, OH • Customers in more than 150 countries • 70,000 employees worldwide • 2009 Sales = $11.87 billion
    4. 4. 4 4© 2010 Eaton Corporation. All rights reserved. Introduction to Eaton Fun facts • One of the largest companies few have heard of • #2 globally in single-phase products, #1 three- phase global manufacturer of UPSs • 55% of sales outside the U.S. • NEWSWEEK magazine ranks Eaton #16 overall on the Green Rankings list and #1 in the General Industrials category!
    5. 5. 5 5© 2010 Eaton Corporation. All rights reserved. Introduction to Eaton Growth through acquisitions Have you used these brands? • Best Power • Exide Electronics • Powerware® • MGE Office Protection Systems™
    6. 6. 6 6© 2010 Eaton Corporation. All rights reserved. Power outages can impact anyone 1. Amazon.com – Ashburn, VA – 6/10/09 2. Rackspace Hosting – Dallas, TX – 6/29/09 3. Fisher Plaza – Seattle, WA – 7/2 to 7/3/09 4. Rackspace Hosting – Dallas, TX – 7/7/09 5. State of Missouri – Jefferson City, MO – 8/4/09 6. The Planet – Dallas, TX - 8/4/09 7. Internap Network Services – Boston, MA – 8/5/09 8. Server Beach – Herndon, VA – 8/28/09 9. Washington Metro – Washington, D.C. – 11/4/09 10. Harvard University – Cambridge, MA – 12/28/09 U.S. Department of Energy Reports…  33 percent of companies lose $20,000 to $500,000  20 percent lose $500,000 to $2,000,000  15 percent lose more than $2,000,000 …when a power outage impacts an IT environment The impact of power outages
    7. 7. 7 7© 2010 Eaton Corporation. All rights reserved. The impact of power outages Total number of people affected by outages 13,566,778 Total duration of outages 196,212 minutes (approximately 3,270 hours or 136 days) Total number of outages 2,840 Average number of people affected per outage 7,483 Average duration of outage 194 minutes (nearly 3.25 hours) What caused 2009 reported outages? When do reported outages happen?
    8. 8. 8 8© 2010 Eaton Corporation. All rights reserved. Battery backup solutions should be attached to all plugged in IT equipment POS terminals Workstations Desktops Virtual machines Kiosks + Tower servers Network routers Backup storage Wireless routers Telco / VoIP + Rack servers Network routers Storage arrays Racks / rack power Servers & networking closets Workstations & terminals Small data centers Large data centers + Blade servers Network routers Storage arrays / tape Providing peace of mind for you!
    9. 9. 9 9© 2010 Eaton Corporation. All rights reserved. Let’s review: A UPS is… An uninterruptible power system (UPS) is defined as a backup power system used to ensure uninterrupted power for various electronic devices. Uninterrupted power may be achieved in the following ways: • Provides backup power when utility power fails • Either long enough for critical equipment to shut down sequentially, ensuring no data is lost, or • Long enough to operate required loads before a generator comes online • Provides clean and regulated power to electronic devices
    10. 10. 10 10© 2010 Eaton Corporation. All rights reserved. The impact of power outages What challenges do YOU see with UPSs?
    11. 11. 11 11© 2010 Eaton Corporation. All rights reserved. The impact of power outages What challenges do YOU see with UPSs?
    12. 12. 12 12© 2010 Eaton Corporation. All rights reserved. They… • Waste valuable space: Battery backup solutions should not take up valuable space that is needed for server and storage capacity. • Drive up energy costs & generate heat: Inefficient UPS solutions waste as much as 25%+ of the electricity flowing through them. Not only does this cost you in energy consumption, but also it generates heat. • Require too much maintenance: Some battery backup solutions require frequent battery replacements or are just poor quality and unreliable. • Are hard to monitor and manage: The monitoring and management software is expensive and also difficult to install, use and get valuable information from. • Don’t scale to support growth: Many battery backup solutions are not designed to scale to support your growing requirement. This leads to wasted money from buying more than what is needed or having to throw out and replace. Legacy backup power solutions are not efficient
    13. 13. 13 13© 2010 Eaton Corporation. All rights reserved. Eaton solutions… …solve many of the challenges seen in other backups. They are designed to deliver: Virtualization Healthcare City
    14. 14. 14 14© 2010 Eaton Corporation. All rights reserved. Leading energy efficiency • Leading efficiency for UPSs • UPSgrade recycling program • Fewer wasted batteries with ABM® battery charging technology
    15. 15. 15 15© 2010 Eaton Corporation. All rights reserved. Simplified manageability • Leading software solutions • vCenter™ Server plug-in with Intelligent Power® Manager • Technology alliance with ...VMware / Level Platforms / Cisco
    16. 16. 16 16© 2010 Eaton Corporation. All rights reserved. The three building blocks of power management Connectivity Ethernet Web/SNMP connectivity card inside Eaton UPS Supervision / Administration Protection Intelligent Power Protector software – installed on protected equipment Intelligent Power Manager software – standalone or plugged into virtual environment console Monitored/ Switched ePDU
    17. 17. 17 17© 2010 Eaton Corporation. All rights reserved. Intelligent Power Software Suite simplifies power management, even in a virtual environment • Eaton’s monitoring and management software, Intelligent Power Manager, can be integrated into vCenter’s dashboard through a plug-in for advanced management capabilities.  Power events are logged in the Events tab – they can trigger VMotion™, which moves applications to servers unaffected by power problems. • Eaton’s protection software, Intelligent Power Protector, enables automatic, graceful shutdown of servers and virtual machines.
    18. 18. 18 18© 2010 Eaton Corporation. All rights reserved. Intelligent Power Manager • View similar devices and all alerts from a single Web interface • Mass upgrade firmware • Manage shutdown agents • Auto discovery automatically detects network devices • Edit and configure SNMP devices • View UPSs and other power devices from VMware's vCenter dashboard with our plug-in • Triggers vMotion to move virtual machines to an available server or co-located cloud enterprise data center during a power outage Intelligent Power Protector • Gracefully shuts down computers and servers during an extended power outage • Easy-to-use interface from any PC with a Web browser • Acquires UPS information through local or network communication • Can be remotely managed, configured and updated with Intelligent Power Manager Features and benefits See all devices, even globally, from any PC on the network Receive date- and time-stamped event notifications
    19. 19. 19 19© 2010 Eaton Corporation. All rights reserved. Superior reliability • Leading warranty – three years, including batteries • ABM battery charging technology • Top OEMs choose Eaton for their UPSs
    20. 20. 20 20© 2010 Eaton Corporation. All rights reserved. Innovative designs • More power in less U space • Scalable/redundant models • More extended battery options • Hot-swappable batteries • Powerware Hot Sync® • Load segmentation
    21. 21. 21 21© 2010 Eaton Corporation. All rights reserved. The BladeUPS solution The BladeUPS® solution is a highly flexible UPS and power distribution system available for small to medium critical power applications, including small computer rooms or data centers (typically < 200 kW).
    22. 22. 22 22© 2010 Eaton Corporation. All rights reserved. The BladeUPS solution – data center solution Decentralized output distribution system Distribute the power directly from each parallel UPS system, using multiple output paths, eliminating a single point of failure and simplifying the distribution for more flexibility and lower installation costs.
    23. 23. 23 23© 2010 Eaton Corporation. All rights reserved. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 BladeUPS reliability by design • Each UPS module includes: • Logic contol • Inverter • Rectifier • Static switch • Maintenance bypass • Battery • Battery breaker • Output distribution breaker • Anytime units are paralleled for “redundancy,” all components gain redundancy 12 kW BladeUPS 50A 50A 70A Automatic internal maintenance bypass Internal Battery String 1 Electronics Module Internal Battery String 2 AC in AC out Static bypass Extend Run in Recept out UPS system control Inverter Rectifier Redundant internal battery Battery Breaker 4 UPS modules support 36 kW N+1 redundancy The electronics module, battery and even entire chassis can be “hot swapped” Chassis only hot swappable in parallel redundant systems
    24. 24. 24 24© 2010 Eaton Corporation. All rights reserved. Dedicated support • #1 presales support • 95%+ service plan satisfaction • Leading warranties
    25. 25. 25 25© 2010 Eaton Corporation. All rights reserved. Eaton power quality solutions Single-phase UPS Workstation, home A/V, networks and servers, computer rooms, bank ATMs, clinical lab equipment, industrial PLC DC Systems Wireless, DSL, central office, customer premise equipment Three-phase UPS Data centers, diagnostic imaging equipment, broadcast transmitters, government facilities, industrial applications Services Maintenance / warranty, 7x24 remote monitoring, system integration UPS and DC Systems 70% Services 30% Power distribution Data center applications 3.5 to 20 kVA 8 to 3,000 kVA
    26. 26. 26 26 Standby Line-interactive‡ OnlineLargeonlineOtherproducts ‡Not shown here: Nova AVR® UPS (600–1100 VA), Eaton 5115 Tower UPS (500–1400 VA) and Eaton 5125 UPS tower model (1000–2200 VA) and rackmount model (5–6 kVA) *SNMP and connectivity cards are optional Eaton 9140 UPS • Rackmount, 6U, 0.8 PF • IEC/HW, 7.5–10 kVA • XL, conn Power conditioners • Small/Home office • (8) outlets, 500–700 VA • Tele & data line Eaton 9155 UPS • Tower, small footprint • Config rear, 8–15 kVA • Parallel, long XL, conn, S/P Eaton FERRUPS® • Industrial/Marine, rack or tower • Customized unit, 500–18,000 VA • Isolation, XL, conn, MBP Eaton 9170+ UPS • Scalable & flexible • Config rear, 3–18 kVA • N+X, XL, conn, S/P Eaton 9135 UPS • Rack/tower form factor, 3U • 0.7 PF, 5–6 kVA, HW • Load seg, XL, conn Connectivity* • ConnectUPS-MS, X, BD, E • NMC Mini-Slot • Multiserver & relay Eaton EX RT UPS • Rack/tower 6U, 0.7–0.8 PF • HW, 5–11 kVA • XL, conn, MBP, UL924 Eaton 3105 UPS • Small/Home office • (8) outlets, 500–700 VA • Tele & data line Eaton 5130 UPS • Network, servers • 0.9+ PF, (6) outlets, 1000–3000 VA • Load seg, USB, conn, XL Eaton 5115 UPS • Network, servers • (4) outlets, 500–1500 VA • Load seg, USB, conn Eaton 5110 UPS • Small/Home office • (8) outlets, 500–1500 VA • USB, tele & data Eaton EX UPS • Tower or rack/tower • 0.8–0.9 PF, 700–3000 VA • Load seg, XL, conn Eaton 9130 UPS • Tower or rack 2U • 0.9 PF, 700–3000 VA, HE mode • Load seg, XL, conn Eaton MX UPS • Rack/tower form factor, 3U • 0.8–0.9 PF, 5 kVA • Load seg, XL, conn Eaton Evolution/S • Network, servers • 0.9 PF, (6) outlets, 650–3000 VA • Load seg, USB, conn, XL Software • Intelligent Power Manager • Intelligent Power Protector • Power Xpert® Eaton single-phase UPS offerings
    27. 27. 27 27© 2010 Eaton Corporation. All rights reserved. Comparing Eaton core VA points Eaton • Product – 5130 1500 VA • Price – $629.99 • Power – 1400W Eaton • Product – Evolution® 1550R VA • Price – $362.99 • Power – 1100W Eaton • Product – 5130 1000 VA • Price – $547.99 • Power – 600W Eaton • Product – Evolution 850T VA • Price – $234.99 • Power – 600W APC • Product – Smart-UPS® 1500 VA • Price – $659.99 • Power – 980W Tripp•Lite • Product – SmartPro® 1500 VA • Price – $433.99 • Power – 900W APC • Product – Smart-UPS 1000 VA • Price – $593.00 • Power – 1000W Tripp•Lite • Product – Smart 750 VA • Price – $284.99 • Power – 500W $30 Savings 30% More power $71 Savings 19% More power $46 Savings 40% More power $50 Savings 17% More power
    28. 28. 28 28© 2010 Eaton Corporation. All rights reserved. ePDU Power and Function Basic – Input plug and receptacles Monitored – Plus, network connection Advanced Monitored – Plus, monitoring to the receptacle level Switched – Plus, receptacle level control
    29. 29. 29 29© 2010 Eaton Corporation. All rights reserved. Remote Power Panel (RPP) Power Distribution Unit (PDU) Large UPS Input Switchgear & Distribution Backup GensetEnclosure & Rack RPP Primary Utility Eaton UPS, STS, PDU, RPP, TVSS, rack power strips, rack monitors, software, connectivity and enclosures provide reliable data center power products for both raised and non-raised floor applications in an integrated package. Static Transfer Switch (STS) TVSS TVSS Rack UPS Small UPS Rack monitor, software & connectivity Eaton’s data center power chain
    30. 30. 30 30© 2010 Eaton Corporation. All rights reserved. How it all comes together