• Save
Laparoscopy, Urology & Gynecology Catalogue
Upcoming SlideShare
Loading in...5
×
 

Like this? Share it with your network

Share

Laparoscopy, Urology & Gynecology Catalogue

on

  • 2,462 views

Laparoscoy, Urology & Gynecology Catalogue

Laparoscoy, Urology & Gynecology Catalogue

Statistics

Views

Total Views
2,462
Views on SlideShare
2,459
Embed Views
3

Actions

Likes
1
Downloads
0
Comments
0

1 Embed 3

http://www.slideee.com 3

Accessibility

Upload Details

Uploaded via as Adobe PDF

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

Laparoscopy, Urology & Gynecology Catalogue Document Transcript

  • 1. Medical Catalogue Endoscopy Visualisation solutions in sight Fiberoptics Engineering Service Schölly Fiberoptic GmbH Fon + 49 (0) 76 66 / 908-0 eMail info@schoelly.de Robert-Bosch-Strasse 1-3 Fax + 49 (0) 76 66 / 908-380 Internet www.schoelly.de D -79211 Denzlingen Fax-Service + 49 (0) 76 66/ 908-381 MPC003-000-0610-01
  • 2. Minimal Invasive Surgery Fields of application of Schölly medical products • 3D Robot Surgery „Da Vinci® “ • Laparoscopy • Plastic Surgery • Arthroscopy • Neurosurgery • Spinal Surgery • Dermatology • Ophthalmology • Urology • Gynecology • Pediatrics • Vessel Harvesting • ENT • PDT • Your Application?
  • 3. More than 30 years experience in the medical field The Company Schölly does not only stand for carefully engi- neered high-end products. We are also commit- ted to corporate ethics and responsibility in dea- ling with our employees, customers, business partners, suppliers and our home town Denzlingen alike. For more than 30 years now, we have been maintaining a corporate culture that is both self- contained and open to inspiration from the out- side world. Our teams are staffed with professio- nals who create superior products of utmost reli- ability, based on future-oriented, well-integrated designs. By focusing our creative energy, we can offer visualization technology that is tailor-made to the needs of our customers: solutions in sight. Corporate History Since its establishment in 1973 our company has evolved from a single-product manufacturer to a vendor of high sophisticated visualization systems. At our Denzlingen site alone, a work- force of about 200 team members develop and manufactur a yearly output of next to 13,000 visualization systems. At the same time a net- work of agencies spans the globe to cater for our customers’ needs worldwide. The future will see an increasing miniaturization of our medical devices, aimed at easing minimal invasive surgery for patients even further. In engineering, new fields of application will open up as modular optical probes converge with camera imaging and video archiving technologies. I-06
  • 4. Our Program Visualization for medical and engineering applications is our core business. All products made by Schölly are targeted at making concealed structures visible and accessible for non-destructive/mini- mal invasive treatment, using technology such as micro-optics, fiberoptics and electronics. We design, manufacture and sell all components dedicated to that purpose independently from the endoscope, almost a classic in our product line, to highly complex visualization systems. Long-term partnerships with OEM customers and users promote the continuous improvement and further development of our products as well as research into new fields of application. Our flexibility and readiness to adapt to other mindsets and markets has added much to our credit with partners worldwide. Quality Management System DIN EN ISO 9001:2000 Reg.-Nr. 058247 QM DIN EN ISO 13485:2001 Reg.-Nr. 058247 MP21 DIN EN ISO 13485:2003 Reg.-Nr. 058247 MP23 Anh. II RL 93/42/EWG Reg.-Nr. 058247-07 Reliability & Precision To support minimal invasive medical applications we offer visualization systems for diagnostics and surgery. The main goal here is to anticipate specific customer requirements and translate them into marketable and cost-effective products and systems. By continuously investing in the improvements of existing products, we guarantee to our customers optimal product quality and make their life easier. This means that our endoscopes and fiber-optic systems must meet extremely exacting demands in terms of image quality, reliability and corrosion resistance in order to perform well under the extreme conditions of use that are so frequently met in medical applications. I-06
  • 5. * Orthopedics * Laparoscopy * Gynecology * Urology * Ear - Nose - Throat Light Sources, Cameras & Accessories FlexiFairplay Technology & Special Endoscopes * Copyright 1998 3B Scientific GmbH, Hamburg, Germany I-06
  • 6. Laparoscopy I-06
  • 7. Content Laparoscopy * Laparoscopy Page Content LAP 200 Laparoscopes 5.0/6.5/10 mm LAP 201 FlexiLux minioptic LAP 202 FlexiLux minioptic Ø 2.0 mm with accessories LAP 203 Veress cannulas and trocar sleeves LAP 204 Suction, irrigation, coagulation LAP 205 Bipolar forceps and cables LAP 206 Rotatable laparoscopy hand instruments LAP 207 Rotatable laparoscopy hand instruments LAP 208 Needle holders, alligator forceps, palpation probes LAP 209 Clip applying forceps LAP 210 Surgiflator ® - 20 LAP 211 Surgiflator ® - 30 * Copyright 1998 3B Scientific GmbH, Hamburg, Germany I-06
  • 8. Laparoscopy Laparoscopes FlexiLux II - FlexiLux II - Laparoscopes Large Screen Laparoscopes Endoscope-Ø: 10.0 mm Endoscope-Ø: 5.0 mm Working length: 344 mm Working length: 312 mm 11.0031a Viewing direction: 0° wide angle 11.0055a Viewing direction: 0° wide angle 11.0043a Viewing direction: 30° wide angle 11.0057a Viewing direction: 30° wide angle 11.0041a Viewing direction: 45° wide angle FlexiLux II - Laparoscopes * Endoscope-Ø: 6.5 mm Working length: 336 mm 11.0051a Viewing direction: 0° wide angle 11.0053a Viewing direction: 30° wide angle * Available on request. LAP 200 I-06
  • 9. Laparoscopy Laparoscopes 11.0123a FlexiLux 11.0480a FlexiLux II - Minioptic OP-Laparoscope Luer-Lock-connection Endoscope-Ø: 2.0 mm Viewing direction: 0° wide angle Length rigid: 241.5 mm Endoscop e- Ø: 10.0 mm High resolution Viewing direction: 0° wide angle image bundle: 30,000 pixels Working length: 277 mm Instrument channel Ø: 5.5 mm 11.0121a FlexiLux 11.0700a FlexiLux II - Minioptic OP-Laparoscope Only for use with ring applicator luer-lock connection for insufflation Endoscope-Ø: 3.0 mm Viewing direction: 0° wide angle Length rigid: 302 mm High resolution Endoscope-Ø: 11.0 mm image bundle: 30,000 pixels Viewing direction: 0° wide angle Working length: 277 mm Instrument channel Ø: 6.0 mm 11.0125a Sealing Cap for stop cock for OP-Laparoscope item no.: 11.0123a 11.0126a Silicone Flap Valve for OP-Laparoscope item no.: 11.0123a I-06 LAP 201
  • 10. Laparoscopy Minioptic Set The optical veress needle facilitates an inside view Single Components right from the first puncture. 11.0480a FlexiLux II - Minioptic Advantages: • Reliable diagnosis under local anaesthesia. • Reliable diagnosis for polytraumatic patients. Viewing direction: 0° wide angle • „Freiburg sluice“ according to doctor Schaller (†): Endoscope-Ø: 2.0 mm One catheter remains in the abdomen thus allowing Working length rigid: 241.5 mm easy control in case of complications, pain, etc. High resolution image bundle: 30,000 p. • Utilization as viewing trocar. 11.0569a Cannula with locking mechanism to fix • Optical safety with biopsies. optic in position. • Examination with veress needle with integrated optic: If results prove harmful, actual surgery may be initiated by immediate dilatation from Ø 3.0 mm to Ø 5.0 mm and direct surgery may be effected Outside : 3.2 mm with a Ø 5.0 mm optic. Inner-Ø: 2.7 mm • Multifunctional, as the accessory can also be used Working length: 170 mm seperately (e.g. veress needle with luer-lock, dilatation set may be used as reducing sleeve). 11.0493a Cannula without locking mechanism to fix optic in position, with luer-lock. Two positions are possible during puncture: • Puncture position Pos. 1: Outside-Ø: 3.0 mm The distal end of the objective stays inside the Inner-Ø: 2.7 mm needle. Working length: 190 mm • Sight position Pos. 2: 11.0485a Dilatation Set 3.0 mm to 5.0 mm The distal end of the objective is leveled with the needle’s end. - 1 Dilatation basic tube Length: 150 mm - 1 Extension tube Length: 210 mm 11.0489a Paediatric Dilatation Set Pos. 1 3.0 mm to 5.0 mm Pos. 2 - 1 Dilatation-basic tube Length: 190 mm - 1 Extension tube Length: 210 mm Sets 11.0488a Dilatation Trocar 11.0632a Minioptic and Cannula 3.0 mm, From Ø 5.0 mm to Ø 10.0 mm with locking mechanism to fix optic in position. Complete system, Length: 235 mm consisting of item no.: 11.0480a Effective Ø: 10.9 mm 11.0569a 11.0484a Dilatation Trocar 11.0634a Minioptic and Cannula 3.0 mm for adult, From Ø 5.0 mm to Ø 10.0 mm without locking mechanism to fix optic in position, with dilatation set 3/5/10 mm Complete system, consisting of item no.: 11.0480a Length: 235 mm 11.0493a Effective Ø: 10.4 mm 11.0485a Gasket to be put over the 11.0488a proximal end. LAP 202 I-06
  • 11. Laparoscopy Veress Cannulas/ Trocar systems Veress Cannulas Silicone Valves w3020 Veress cannula with stop cock and Luer-lock; Ø 2 mm, length 100 mm 11.0298a Silicone Valve single use w3021 Veress cannula with stop cock and 1 box = 5 pieces Luer-lock; Ø 2 mm, length 120 mm System: 5.5 mm w3022 Veress cannula with stop cock and 8.0 mm Luer-lock; Ø 2 mm, length 150 mm Suitabe for item no.: 11.0299a.m2 11.0311a.m2 Trocar Systems 12.1000a.m2 Trocar sleeve with silicone valve, System 3 mm, insufflation stop cock 12.1005a.m2 Trocar with triangular tip and hollow 11.0315a Silicone Valve single use cut, system 3 mm, 1 box = 5 pieces suitable for 12.1000a.m2 System: 11.0 mm 11.0299a.m2 Trocar sleeve with silicone valve and 12.5 mm insufflation stop cock, 5.5 mm for 5 mm Suitabe for item no.: 11.0312a.m2 endoscopes and instruments. 11.0330a.m2 11.0496a.m2 Trocar with hollow cut 5.5 mm, suitable for 11.0299a.m2 11.0311a.m2 Trocar sleeve, with silicone valve and Dilatation Sets insufflation stop cock, 8 mm for 7.5 mm endoscopes and instruments. 11.0502a.m2 Trocar with hollow cut 8 mm suitable for 11.0311a.m2 s720329 Dilatation-Set 5 to 10 mm 11.0312a.m2 Trocar sleeve with silicone valve and insufflation stop cock, 11 mm for 10 consisting of guiding tube and mm endoscopes and instruments. dilatation sleeve 11.0498a.m2 Trocar with hollow cut 11 mm, s720333 Dilatation-Set 10 to 15 mm suitable for 11.0312a.m2 consisting of guiding tube and 11.0316a Safety-Trocar 11 mm, dilatation sleeve with autom. locking mechanism, suitable for 11.0312a.m2 s720323 Dilatation-Set 10 to 20 mm 11.0330a.m2 Trocar sleeve with silicone valve and consisting of guiding tube and insufflation stop cock, 12.5 mm for 12 dilatation sleeve mm endoscopes and instruments. 11.0331a.m2 Trocar with hollow cut 12.5 mm, suitable for 11.0330a.m2 Reduction Sleeves s720311 Reduction sleeve 10 to 5.5 mm s720318 Reduction sleeve 15 to 10 mm s720321 Reduction sleeve 20 to 5.5 mm s720322 Reduction sleeve 20 to 10 mm All trocars are secured against roll off. I-06 LAP 203
  • 12. Laparoscopy Suction/ Irrigation/ Coagulation System 5 mm: System 10 mm: Irrigation - Suction - Bipolar Coagulation Irrigation - Suction The multifunctional instrument consists of a suction The irrigation suction reduction sleeve is inserted irrigation tube (Ø 5 mm) with inserted bipolar electrode. through the 10.5 mm trocar. Thus suction, irrigation Without changing the instrument, three functions can and the cleaning of the optic is possible at any time. be worked with one hand: All working instruments with Ø 5 mm and more than Irrigation, suction and bipolar coagulation. 380 mm length can be inserted through the irrigation- The inserted electrode can be rotated during work. suction reducer sleeve, e.g. coagulation instruments, For suction, the electrode is drawn back to the stop. forceps, scissors. The instrument is drawn back for suction. No need to take it off. s720146 Suction-Irrigation-Tube s720147 Suction-Irrigation Reduction Sleeve Working-Ø: 5.0 mm Length: 330 mm Working-Ø: 10 mm With two trumpet valves and large Length: 330 mm Luer-lock connector with seal. With two trumpet valves for suction and irrigation. Reduction through trumpet valve. Instruments and electrodes of Ø 5 mm can be inserted. Bipolar Coagulation Electrodes For insertion into tube s720146. „Coagulation“ and “Irrigation“ position are safely fixed by stops. Length: 380 mm s720122 Tip „Ball“ s720126 Tip „L-Hook“ s720127 Needle, 10 mm s720128 Needle, 15 mm Monopolar Electrodes Monopolar Cable for 05.0655r HF-Unit Erbe ACC/ICC Length: 3.0 m 12.0720a Dissection-Spatula monopolar 05.0656r HF-Unit Martin, Berchtold, Erbe Outer-Ø: 5.0 mm Length: 330 mm Length: 3.0 m Insulated sheath 05.0657r HF-Unit Valleylab, Bovie, Conmed, 12.0721a Dissection-Hook J monopolar Birtcher, Medtrex Outer-Ø: 5.0 mm Length: 3.0 m Length: 330 mm Insulated sheath 12.0722a Dissection-Hook L monopolar Outer-Ø: 5.0 mm Length: 330 mm Insulated sheath LAP 204 I-06
  • 13. Laparoscopy Bipolar Forceps and Cables Bipolar Alligator Forceps Bipolar Silicone Cable for tubes and heavy bleeding Instrument side Flat connector for bipolar forceps, electrodes and tweezers Unit side Connector for Martin, Berchtold, Aesculap s720150 Ø 5 mm, length 330 mm with U-handle s720162 Ø 5 mm, length 400 mm with U-handle s360139 Cable length: 4.5 m Bipolare Coagulation Forceps Unit side for generators Erbe and Select s720152 Ø 5 mm, length 330 mm with U-handle, micro, s360131 Cable length: 4.5 m for area coagulation s720168 Ø 5 mm, length 330 mm with U-handle, macro, for area coagulation s720160 Ø 5 mm, length 400 mm with U-handle, micro, for area coagulation s720164 Ø 5 mm, length 400 mm with U-handle, macro, for area coagulation Spare parts for Bipolar Forceps s720151 Electrode for s720150 s720163 Electrode for s720162 s720153 Electrode for s720152 s720169 Electrode for s720168 s720161 Electrode for s720160 s720165 Electrode for s720164 s720156 Handle for s720150/52 s720160/62 s720164/68 s720157 Sheath Length: 330 mm for s72050/52/68 s720158 Sheath Length: 400 mm for s72060/62/64 I-06 LAP 205
  • 14. Laparoscopy Monopolar Rotatable Instruments The new generation of rotatable and detachable instruments offers: • Safe positioning of jaws by simply turning the handle. • Safe cleaning due to easy disassembling. • Cost reduction due to simple exchange of single elements. • Insulated sheath. • HF-connector. 12.0508a Dolphin Alligator Forceps 12.0523a Atraumatic Alligator Forceps insulated sheath insulated sheath Ø 5.0 mm Length: 330 mm Ø 5.0 mm Length: 330 mm Without ratchet Without ratchet 12.0518a Spoon Forceps insulated sheath 12.0544a Scissors Metzenbaum insulated sheath Ø 5.0 mm Length: 330 mm Ø 5.0 mm Length: 330 mm Without ratchet, fine serrated straight 12.0519a Cobra Alligator Forceps 12.0545a Scissors Metzenbaum insulated sheath insulated sheath Ø 5.0 mm Length: 330 mm Ø 5.0 mm Length: 330 mm Without ratchet, 2 x 2 teeth curved 12.0520a Alligator Forceps insulated sheath 12.1090a Spoon Forceps insulated sheath Ø 5.0 mm Length: 330 mm Without ratchet, serrated Ø 5.0 mm Length: 330 mm 12.0522a Allis Alligator Forceps insulated sheath On request, other lengthes, e.g. 450 mm, Ø 5.0 mm Length: 330 mm jaws pieces and handles are available. Without ratchet LAP 206 I-06
  • 15. Laparoscopy Rotatable Instruments 12.0546a Alligator Forceps Maryland 12.0551a Tube Alligator Forceps insulated sheath insulated sheath Ø 5.0 mm Length: 330 mm Ø 5.0 mm Length: 330 mm Without ratchet Double movable 12.0540a Hook Scissors insulated sheath 12.0547a Alligator Forceps Pike Jaw insulated sheath Ø 5.0 mm Length: 330 mm Ø 5.0 mm Length: 330 mm 12.0555a Alligator and Dissector Forceps Without ratchet insulated sheath Ø 5.0 mm Length: 330 mm Fine fluted, double movable 12.0549a Biopsy Forceps insulated sheath 12.0556a Alligator Forceps insulated sheath Ø 5.0 mm Length: 330 mm Curved, double movable 12.0557a Alligator Grasping Forceps Ø 5.0 mm Length: 330 mm Sheath insulated With thorn Ø 5.0 mm Length: 330 mm Double movable 12.0550a Alligator and Dissector Forceps Monopolar HF-Cable insulated sheath 05.0655r HF-Unit Erbe ACC/ICC Length: 3m 05.0656r HF-Unit Martin, Berchtold, Erbe Ø 5.0 mm Length: 330 mm Length: 3m double movable 05.0657r HF-Unit Valleylab, Bovie, Conmed, Birtcher, Medtrex Other lengths, e. g. 45 cm, jaws pieces and handles Length: 3m are available upon request. I-06 LAP 207
  • 16. Laparoscopy Needle Holder/Forceps/Palpation Probes s720284 Claw Alligator and Extraction s720207 Abdominal Speculum Forceps 2 x 3 teeth for extraction of the gallbladder Ø 5.0 mm Length: 330 mm With finger support and recuperating spring s720285 Claw Alligator and Extraction s720287 Cholangiography Forceps Forceps 2 x 3 teeth for catheters 6 Fr., Ø 10.0 mm Length: 330 mm With finger support and recuperating spring Ø 5.0 mm Length: 330 mm s720286 Gallstone Alligator Forceps Needle Holders with U-handle with straight handle and ratchet 12.0101a Needle Holder with tungsten carbide inserts Ø 5.0 mm Length: 330 mm 12.0100a Bowel Grasper with spring handle Ø 5.0 mm Length: 330 mm 12.0105a Needle Holder with tungsten carbide inserts Ø 5.0 mm Length: 330 mm s720218 Palpation Probe graduated Ø 5.0 mm Length: 360 mm Ø 5.0 mm Length: 330 mm 12.0106a Needle Holder with tungsten carbide inserts s720220 Puncture Needle for Aspiration Ø 5.0 mm Length: 360 mm Luer-Lock Bent right, detachable 12.0107a Needle Holder with tungsten carbide Ø 5.0 mm Length: 330 mm inserts Needle-Ø: 1.8 mm Ø 5.0 mm Length: 360 mm Bent left, detachable LAP 208 I-06
  • 17. Laparoscopy Clip Applying Forceps Clip Applying Forceps rotatable and detachable Schölly recognized the many problems faced by sur- geons staffs using currently available endoscopic clip appliers which correspond to the needs of the surgeons, the hygiene and the cost aspect. The jaws are absolutely free of pins and links which secures them against breaking. Onehanded (360°) rotation in both directions is possible. The sheath locks automatically when the jaws are closed. The clip applier is easy to dismantle for cleaning and sterilization. All clip applying forceps have a diameter of 10 mm and a length of 33 cm. Clip Applyers for SLS Clips 12.LCASLS5 Clip Applyers , rotatable, detachable, Clip SLS medium large 12.V3120.L 20 magazines with 6 Clips for 12.LCASLS5, medium large Clip Applyers for ETHICON Titanium Clips 12.ZEM Clip Applyers for ETHICON Titanclip, medium 12.ZEML Clip Applyers for ETHICON Titanclip, medium large 12.ZEL Clip Applyers for ETHICON Titanclip, large Upon request clip applying forceps can be produced in different sizes and types. If so we need more details about the type and size of the clip. All forceps are produced for a particular size resp. type. It is in no case allowed to use other clip types or sizes than indicated. Please follow the instructions stated on the handle/internal wire. I-06 LAP 209
  • 18. Laparoscopy Surgiflator ® Surgiflator ® - 20 • 20 l Flow/min. • Easy set-up • ISO-Standard at patient exit • User adjustment programmable Basics Technical Data 16.0040r.M1 1 Surgiflator 20 l basic unit Main supply 100-240 V~, 50-60 Hz z0101-01 1 Mains cable with German plug, 2 m Max. power input 75 V A Pressure range 0-30 mm Hg Accessories Max. gasflow 20 l/min z0480-01 1 High pressure tube CO 2, gas connection Insufflation medium med. CO 2 device DIN/Cylinder DIN, 1.5 m Main fuse T 3,15 A, IEC 127/UL z5030-01 1 High pressure tube for central gas supply, NIST/DIN, 3 m Max. current input 100 V/0.7 A 240 V/0.3 A z0501-01 1 Cylinder CO 2 , 0.,75 kg, DIN, empty z0502-01 1 Cylinder CO 2 , 0.75 kg, PIN Index, empty Dimensions (W x H x D) 265 x 140 x 410 mm z1422-01 1 Tubing set for insufflation, with filter Weight approx. 7 kg disposable, sterile, 1 pack = 10 pcs. Classification Protection class 1, z0452-01 1 Tubing set for insufflation, reusable, 3 m type BF, IP 41 z0536-01 1 Filter ISO, hydrophobic, Manufactured and disposable, sterile tested acc. to EN 60601-1/ICE 601-1 EMC EN 60601-1-2/ICE 601-1-2 LAP 210 I-06
  • 19. Laparoscopy Surgiflator ® Surgiflator ® - 30 • 30 l Flow/min. • High safety • User adjustment programmable • Integrated gas heating • Pressure relief system and fluid sensor Basics Technical Data 16.0050r.M1 1 Surgiflator 30 l basic unit Main supply 100-240 V~, 50-60 Hz z0101-01 1 Mains cable with German plug, 2 m Max. power input 75 V A Pressure range 0-30 mm Hg Accessories Max. gasflow 30 l/min z5038-01 1 High pressure tube for central Insufflation medium med. CO 2 gas supply, NIST to UNI (Italy), 3 m Main fuse T 3,15 A, IEC 127/UL z5044-01 1 High pressure tube CO2, gas connection device US and gas bottle DIN, 1.5 m Max. current input 100 V/0.7 A 240 V/0.3 A z0500-01 1 PIN Index adapter for high pressure tube z0452-01 1 Tubing set for insufflation, reusable, 3 m Dimensions (W x H x D) 265 x 138 x 410 mm z1415-01 1 Tubing set for gas heating, reusable, 3 m Weight approx. 7 kg z1422-01 1 Tubing set for insufflation, incl. filter Classification Protection class 1, disposable, sterile, 1 pack = 10 pcs. type BF, IP 41 z0536-01 1 Filter ISO/-F/ISO-M, hydrophobic, Manufactured and disposable tested acc. to EN 60601-1/ICE 601-1 EMC EN 60601-1-2/ICE 601-1-2 I-06 LAP 211
  • 20. Gynecology I-06
  • 21. Content Gynecology * Gynecology Page Content GYN 300 Hysteroscopes 2.0/2.9/4.0 mm GYN 301 Laparoscopes GYN 302 Veress cannulas and trocar sleeves GYN 303 Hysteroscope sheaths GYN 304 Resectoscopes active, passive GYN 305 Resectoscope sheaths, electrodes GYN 306 Scissors and forceps * Copyright 1998 3B Scientific GmbH, Hamburg, Germany I-06
  • 22. Gynecology Hysteroscopes 11.0480a FlexiLux II - Minioptic FlexiLux II - Large Screen Hysteroscopes Compatible with the brands Wolf, Olympus and ACMI Endoscope-Ø: 4.0 mm Endoscope-Ø: 2.0 mm Viewing direction: 0° wide angle Working length rigid: 241.5 mm High res. image bundle: 30,000 pixels Compatible to system Wolf Working length: 298 mm FlexiLux II - Large Screen 41.1005a Viewing direction: 0° standard Hysteroscopes 41.1001a Viewing direction: 5° standard Working length: 300 mm 41.1011a Viewing direction: 25° standard Working length: 303 mm 41.1021a Viewing direction: 70° wide angle Endoscope-Ø: 2.9 mm Working length: 302 mm 41.0160a Viewing direction: 0° wide angle 41.0161a Viewing direction: 30° wide angle Compatible to system Olympus FlexiLux II - Large Screen Working length: 280 mm Hysteroscopes 41.1101a Viewing direction: 0° standard 41.1111a Viewing direction: 12° standard Working length: 283 mm 41.1121a Viewing direction: 30° standard 41.1131a Viewing direction: 30° wide angle 41.1141a Viewing direction: 70° wide angle Endoscope-Ø: 4.0 mm Working length: 302 mm 41.0047a Viewing direction: 0° standard 41.0049a Viewing direction: 0° wide angle 41.0059a Viewing direction: 12° standard Compatible to system ACMI 41.0057a Viewing direction: 30° standard 41.0055a Viewing direction: 30° wide angle Working length: 301 mm 41.0121a Viewing direction: 70° wide angle 41.1221a Viewing direction: 0° wide angle Working length: 299 mm 41.1231a Viewing direction: 12° standard 41.1201a Viewing direction: 30° wide angle 41.1211a Viewing direction: 30° standard Working length: 305 mm 41.1212a Viewing direction: 70° wide angle GYN 300 I-06
  • 23. Gynecology Laparoscopes FlexiLux II - Large Screen 11.0123a FlexiLux Laparoscopes OP-Laparoscope Luer-Lock connection Endoscope-Ø: 5.0 mm Working length: 312 mm Endoscope-Ø: 10.0 mm Viewing direction: 0° wide angle 11.0055a Viewing direction: 0° wide angle Working length: 277 mm 11.0057a Viewing direction: 30° wide angle Instrument channel Ø: 5.5 mm FlexiLux II Laparoscopes 11.0121a FlexiLux OP-Laparoscope Only for use with ring applicator Luer-Lock connection for insufflation Endoscope-Ø: 10.0 mm Working length: 344 mm 11.0031a Viewing direction: 0° wide angle 11.0043a Viewing direction: 30° wide angle Endoscope-Ø: 11.0 mm 11.0041a Viewing direction: 45° wide angle Viewing direction: 0° wide angle Working length: 277 mm Instrument channel Ø: 6.0 mm 51.0394a Ring Applicator Cone Loader 11.0125a Sealing Cap for OP-Laparoscope item no.: 11.0123a 11.0126a Silicon Valve for OP-Laparoscope item no.: 11.0123a I-06 GYN 301
  • 24. Gynecology Veress Cannulas/Trocar Systems Veress Cannulas Silicone Valves w3020 Veress cannula with stop cock and Luer-lock; Ø 2 mm, length 100 mm 11.0298a Silicone Valve single use w3021 Veress cannula with stop cock and 1 box = 5 pieces Luer-lock; Ø 2 mm, length 120 mm System: 5.5 mm w3022 Veress cannula with stop cock and 8.0 mm Luer-lock; Ø 2 mm, length 150 mm Suitabe for item no.: 11.0299a.m2 11.0311a.m2 Trocar Systems 12.1000a.m2 Trocar sleeve with silicone valve, system 3 mm, insufflation stop cock 12.1005a.m2 Trocar with triangular tip and hollow 11.0315a Silicone Valve single use cut, system 3 mm, 1 box = 5 pieces suitable for 12.1000a.m2 System: 11.0 mm 11.0299a.m2 Trocar sleeve with silicone valve and 12.5 mm insufflation stop cock, 5.5 mm for 5 mm Suitabe for item no.: 11.0312a.m2 endoscopes and instruments. 11.0330a.m2 11.0496a.m2 Trocar with hollow cut 5.5 mm, suitable for 11.0299a.m2 11.0311a.m2 Trocar sleeve, with silicone valve and Dilatation Sets insufflation stop cock, 8 mm for 7.5 mm endoscopes and instruments. 11.0502a.m2 Trocar with hollow cut 8 mm suitable for 11.0311a.m2 s720329 Dilatation-Set 5 to 10 mm 11.0312a.m2 Trocar sleeve with silicone valve and insufflation stop cock, 11 mm for 10 consisting of guiding tube and mm endoscopes and instruments. dilatation sleeve 11.0498a.m2 Trocar with hollow cut 11 mm, s720333 Dilatation-Set 10 to 15 mm suitable for 11.0312a.m2 consisting of guiding tube and 11.0316a Safety-Trocar 11 mm, dilatation sleeve with autom. locking mechanism, suitable for 11.0312a.m2 s720323 Dilatation-Set 10 to 20 mm 11.0330a.m2 Trocar sleeve with silicone valve and consisting of guiding tube and insufflation stop cock, 12.5 mm for 12 dilatation sleeve mm endoscopes and instruments. 11.0331a.m2 Trocar with hollow cut 12.5 mm, suitable for 11.0330a.m2 Reduction Sleeves s720311 Reduction sleeve 10 to 5.5 mm s720318 Reduction sleeve 15 to 10 mm s720321 Reduction sleeve 20 to 5.5 mm s720322 Reduction sleeve 20 to 10 mm All trocars are secured against roll off. GYN 302 I-06
  • 25. Gynecology Hysteroscope Sheaths For FlexiLux II - Hysteroscopes For FlexiLux II - Hysteroscopes Endoscope-Ø: 2.0 mm Endoscope-Ø: 2.9 mm Working length: 241.5 mm Working length: 302 mm Diagnosis- Hysteroscope Sheath Continous - Flow Diagnosis- Hysteroscope Sheath • Atraumatic distal end • Atraumatic distal end • 1 stop cock • 2 stop cocks for continuous flow • Coupling, • Coupling, suitable for endoscope: 11.0480a suitable for endoscope: 41.0161a 51.0401a Diagnosis-Hysteroscope Sheath 51.0430a Continous-Flow Diagnosis- 9 Charr. incl. obturator, blunt Hysteroscope Sheath 15 Charr. incl. obturator, blunt For FlexiLux II - Hysteroscopes For FlexiLux II - Hysteroscopes Endoscope-Ø: 2,0 mm Endoscope-Ø: 2,9 mm Working length: 241.5 mm Working length: 302 mm Operation- Hysteroscope Sheath Continous - Flow • Atraumatic distal end Operation-Hysteroscope Sheath • 2 stop cocks for continuous flow • Atraumatic distal end • Coupling, • 2 stop cocks for continuous flow suitable for endoscope: 11.0480a • Coupling, suitable for endoscope: 41.0160a • Working- Ø: 3.5 mm x 5.1 mm, 12 Charr. 41.0161a • Working length: 188 mm • Working- Ø: 4.2 mm x 6.1 mm, 15.5 Charr. • Instrument channel: 5 Charr. • Working length: 188 mm • Instrument channel: 5 Charr. 51.0400a Operation- Hysteroscope Sheath 12 Charr. 51.0431a Continous - Flow Operation- Hysteroscope Sheath 15.5 Charr. I-06 GYN 303
  • 26. Gynecology Resectoscope s Rotatable Resectoscope Sheath 26 Charr. Resectoscope Sheath 26 Charr. for continuous suction and irrigation, consisting of: for continuous irrigation and suction, consisting of: • 1 outer tube (51.0520b), 1 fix stop cock, lateral • 1 outer tube (51.0519b), 1 fix stop cock, lateral emission bore for optimal irrigation emission bore for optimal irrigation • Large window at distal end • Large window at distal end • Atraumatic tip • Atraumatic tip • Lockable to inner tube • Lockable to inner tube • 1 inner tube (51.0518b) with 1 fix stop cock for • 1 inner tube (51.0517b) with 1 fix stop cock for optimal irrigation, insulated by ceramic tip, optimal irrigation, insulated by ceramic tip, lockable to exterior tube and working unit lockable to exterior tube and working unit • Obturator (51.0382b), blunt • Obturator (51.0382b), blunt 51.0320b Resectoscope Sheath 26 Charr. 51.0319b Resectoscope Sheath 26 Charr. rotatable A particular characteristic of this sheath is the rotata- 42.0370b Visual Obturator ble connection between the inner and outer sheath. It is possible to turn the resectoscope without moving the outer sheath, whereby the risk of postoperative strictures is remarkably reduced. for resectoscope sheaths item no.: 51.0319b 51.0320b For FlexiLux II - Hysteroscopes For FlexiLux II - Hysteroscopes Endoscope-Ø: 4.0 mm Endoscope-Ø: 4.0 mm Working length: 302 mm Working length: 302 mm Working Units (passive) Working Units (active) • On standby the electrode is inside the • On standby the electrode is outside the resectoscope sheath. resectoscope sheath. • Precisely movable with your finger touch. • Precisely movable with your finger touch. • Electric cable supply with double socket. • Electric cable supply with double socket. 51.0384b Working unit Resectoscope (passive) 41.0479b Working unit Resectoscope (active) GYN 304 I-06
  • 27. Gynecology Resectoscope Sheath/Electrodes For FlexiLux II - Hysteroscopes Monopolar Electrodes 24 Charr. Endoscope-Ø: 4.0 mm fitting to all Schölly working units Working length: 302 mm 51.0390b Vaporisation electrode Diagnosis-Hysteroscope Sheath 51.0385b Cutting loop electrode, 30° angled, for 12° and 30° scope 51.0391b Cutting loop electrode, straight 51.0364a Diagnosis-Hysteroscope Sheath incl. obturator, 1 fix stop cock Working-Ø: 5.0 mm 51.0386b Coagulation electrode, pointed Operation-Hysteroscope Sheath 51.0387b Ball electrode 3 mm 51.0392b Ball electrode 5 mm 51.0388b Knife electrode 51.0362a Operation-Hysteroscope Sheaths Working-Ø: 8 mm Working channel-Ø: 7 Charr. 51.0393b Spike electrode 3 mm for flexible instruments, 1 stop cock at working channel, 2 fix stop cocks for suction and irrigation. 51.0389b Scraper, blunt for currentless use Continuous-Flow Operation Sheath 51.0701b Band electrode, lengthwise fluted 51.0702b Cutting loop electrode, 0°, 24 Charr. 51.0703b Ball electrode, 3 mm 51.0704b Vaporisation electrode, 5 mm 51.0330b Cutting loop electrode, 90° angled 51.0363a Continuous-Flow Operation Sheath for 0° and 12° scope Working-Ø: 8 mm Working channel-Ø: 7 Charr. Monopolar Cable for for flexible instruments, 1 stop cock at working channel, 2 rotatable stop cocks 05.0641r HF-unit Storz/Erbe, for separate suction and irrigation. Resectoscope Schölly 05.0642r HF-unit Valleylab, Resectoscope Schölly 05.0643r HF-unit Martin, Aesculap, Berchtold Resectoscope Schölly I-06 GYN 305
  • 28. Gynecology Scissors and Forceps Flexible Scissors and Forceps Flexible Scissors and Forceps Biopsy Forceps, flexible double spoon, IUP Alligator Forceps cutting, double action 442.0050a Size 3 Charr./Fr. 52.0100a Size 9 Charr./Fr. Length of sheath: 280 mm Length of sheath: 220 mm 42.0360a Size 3 Charr./Fr. Length of sheath: 400 mm 42.0365a Size 4 Charr./Fr. Length of sheath: 400 mm 51.0346a Size 5 Charr./Fr. Length of sheath: 400 mm 51.0348a Size 7 Charr./Fr. Length of sheath: 400 mm Scissors, flexible, single action Alligator Forceps, flexible, double action 1.0372a Size 5 Charr./Fr. 42.0048a Size 3 Charr./Fr. Length of sheath: 400 mm Length of sheath: 280 mm 51.0374a Size 7 Charr./Fr. 42.0361a Size 3 Charr./Fr. Length of sheath: 400 mm Length of sheath: 400 mm 42.0363a Size 4 Charr./Fr. Length of sheath: 400 mm 51.0376a Size 5 Charr./Fr. Length of sheath: 400 mm 51.0378a Size 7 Charr./Fr. Length of sheath: 400 mm Bipolar Forceps with U-handle Bipolar Forceps with U-handle, micro s720150 Bipolar Grasping Forceps s720152 Bipolar Coagulation Forceps Ø 5.0 mm Length: 330 mm Ø 5.0 mm Length: 330 mm s720162 Bipolar Grasping Forceps s720160 Bipolar Coagulation Forceps Ø 5.0 mm Length: 400 mm Ø 5.0 mm Length: 400 mm GYN 306 I-06
  • 29. Urology I-06
  • 30. Content Urology * Urology Page Content URO 400 Cystoscopes Ø 2.0/4.0 mm URO 401 Cystoscopes compatible with other brands URO 402 Nephroscope 45° URO 403 Cystoscope Urethroscope sheaths URO 404 Endoscope bridges, working units URO 405 Scissors and forceps URO 406 Working units, resectoscope sheaths URO 407 Resectoscope sheaths, electrodes URO 408 Urethrotome sheath and accessories URO 409 Mini Uretero Renoscopes 6.0 Charr. URO 410 Compact Uretero Renoscopes 7.5 Charr. URO 411 Flexible instruments for URS URO 412 Flexible instruments for URS URO 413 Veress cannulas and trocar sleeves URO 414 Ureteroscopy pump * Copyright 1998 3B Scientific GmbH, Hamburg, Germany I-06
  • 31. Urology Cystoscopes 41.0307a FlexiLux II - FlexiLux II - Laparoscopes Minioptic Endoscope-Ø: 2.0 mm Endoscope-Ø: 5.0 mm Working length: 196 mm Working length: 312 mm Viewing direction: 0° standard 11.0055a Viewing direction: 0° wide angle 11.0057a Viewing direction: 30° wide angle FlexiLux II - Large Screen Cystoscopes FlexiLux II - Laparoscopes Endoscope-Ø: 2.9 mm Working length: 302 mm Endoscope-Ø: 10.0 mm Working length: 344 mm 41.0160a Viewing direction: 0° wide angle 41.0161a Viewing direction: 30° wide angle 11.0031a Viewing direction: 0° wide angle 11.0043a Viewing direction: 30° wide angle 11.0041a Viewing direction: 45° wide angle FlexiLux II - Large Screen Cystoscopes Endoscope-Ø: 4.0 mm Working length: 302 mm 41.0047a Viewing direction: 0° standard 41.0049a Viewing direction: 0° wide angle 41.0059a Viewing direction: 12° standard 41.0057a Viewing direction: 30° standard 41.0055a Viewing direction: 30° wide angle 41.0121a Viewing direction: 70° wide angle URO 400 I-06
  • 32. Urology Cystoscopes FlexiLux II - Large Screen Cystoscopes Compatible with the brands Wolf, Olympus and ACMI (Circon) Endoscope-Ø: 4,0 mm Compatible with system Wolf Working length: 298 mm 41.1005a Viewing direction: 0° standard 41.1001a Viewing direction: 5° standard Working length: 300 mm 41.1011a Viewing direction: 25° standard Working length: 303 mm 41.1021a Viewing direction: 70° wide angle Compatible with system Olympus Working length: 280 mm 41.1101a Viewing direction: 0° standard 41.1111a Viewing direction: 12° standard Working length: 283 mm 41.1121a Viewing direction: 30° standard 41.1131a Viewing direction: 30° wide angle 41.1141a Viewing direction: 70° wide angle Compatible with system ACMI Working length: 301 mm 41.1221a Viewing direction: 0° wide angle Working length: 299 mm 41.1231a Viewing direction: 12° standard 41.1201a Viewing direction: 30° wide angle 41.1211a Viewing direction: 30° standard Working length: 305 mm 41.1212a Viewing direction: 70° wide angle I-06 URO 401
  • 33. Urology Nephroscope Nephroscope 45° Nephroscope sheath for continuous flow Distal and proximal sapphire 41.0682a Nephroscope sheath for use with Nephroscope 45°, Outer-Ø: 7.45 mm consisting of outer sheath 26 Charr., Working length: 200 mm incl. obturator Total length: 278 mm Working channel Ø: 4.7 mm 2 x rinsing channel Ø: 1.5 mm Viewing direction: 0° standard Bending: 45° 41.0630a Nephroscope 45° Instrument bridge 41.0641a Instrument bridge for 41.0630a URO 402 I-06
  • 34. Urology Cystoscope - Urethroscope - Sheaths Cystoscop e- Urethroscop e Sheaths Cystoscop e- Urethroscope Sheaths for diagnosis • Atraumatic distal end • Atraumatic distal end • 2 fix stop cocks for permanent irrigation • 1 stop cock • Large window • Lockable connection • Lockable connection fitting to endoscope item no. 41.0307a fitting to all endoscope bridges and working units 42.0307a Cystoscope-Urethroscope Sheath 7 Charr., incl. obturator, blunt 41.0619a Size 17 Charr./Fr., yellow 2 stop cocks, incl. obturator, blunt 41.0622a Size 19 Charr./Fr., green 2 stop cocks, incl. obturator, blunt 41.0406a Size 21 Charr./Fr., red Cystoscop e- Urethroscop e Sheaths 2 stop cocks, incl. obturator, blunt for therapy • Atraumatic distal end 41.0625a Size 23 Charr./Fr., blue 2 stop cocks, incl. obturator, blunt • 2 stop cocks for permanent irrigation • Lockable connection 41.0626a Size 25 Charr./Fr., white fitting to endoscope item no. 41.0307a 2 stop cocks, incl. obturator, blunt • Instrument channel 3 Charr. Resectoscope Sheaths with central valve 42.0308a Cystoscope-Urethroscope Sheath 42.0410b Resectoscop e sheath 24 Charr. 9 Charr., incl. obturator, blunt and standard obturator 42.0400b Resectoscop e sheath 27 Charr. and standard obturator Visual Obturators 42.0048a Alligator Forceps 280 mm length, 3 Charr. flexible, double action 42.0050a Biopsy Forceps 280 mm length, 3 Charr. flexible, double action 42.0376a Visual Obturator for Cystoscope-Urethroscope sheath item no. 41.0406a, 21 Charr. 42.0378a Visual Obturator for Cystoscope-Urethroscope sheath item no. 41.0625a, 23 Charr. I-06 URO 403
  • 35. Urology Endoscope Bridges/Working Units 41.0422a Diagnostic-Endoscope Bridge 41.0420a Working Unit with Albarran lever Suitable for endoscopes Ø 4 mm and sheaths item no.: 41.0619a Suitable for Cystoscope-/Urethroscope sheath 41.0622a > 19 Charr. 41.0406a With lockable working channel, moveable Albarran 41.0625a lever with fine adjustment, coupler to endoscope 41.0626a and sheath. suitable for: 41.0406a 41.0424a Endoscope Bridge 41.0625a 41.0626a 41.0421a Working Unit with Albarran lever With 1 lockable working channel. Suitable for endoscopes Ø 4 mm and sheaths item no.: 41.0619a 41.0622a 41.0406a As item no. 41.0420a 41.0625a but with 2 lockable working channels. 41.0626a suitable for: 41.0406a 41.0625a 41.0626a 41.0425a Endoscope Bridge With 2 lockable working channels. Suitable for endoscopes Ø 4 mm and sheaths item no.: 41.0619a 41.0622a 41.0406a 41.0625a 41.0626a URO 404 I-06
  • 36. Urology Forceps and Scissors Hand instruments, flexible Optical hand instruments, rigid For application with working unit with Albaran lever Biopsy Scissors 42.0350a Stone Punch flexible double spoon, cutting, double action single action For cystoscope-urethroscope sheath 42.0360a Size 3 Charr./Fr. Size: 25 Charr. Length of sheath: 400 mm 51.0346a Size 5 Charr./Fr. This punch allows the lithotripsy of small stones by Length of sheath: 400 mm breaking down to sizes which can be removed by suc- 51.0348a Size 7 Charr./Fr. tion. The evacuation of the stone fragments can easily Length of sheath: 400 mm be done through the free lumen of the sheath. Scissors 42.0351a Excision Forceps flexible, single action double action For cystoscope-urethro sheath Size: 19-25 Charr. 51.0372a Size 5 Charr./Fr. 42.0353a Excision Forceps Length of sheath: 400 mm double action, cutting 51.0374a Size 7 Charr./Fr. Length of sheath: 400 mm For cystoscope-urethro sheath Alligator Forceps Size: 19-25 Charr. flexible, double action 42.0352a Alligator Forceps, double action 42.0361a Size 3 Charr./Fr. For cystoscope-urethro sheath Length of sheath: 400 mm Size: 19-25 Charr. 51.0376a Size 5 Charr./Fr. Length of sheath: 400 mm 42.0357a Hook Scissors, double action jaws 51.0378a Size 7 Charr./Fr. Length of sheath: 400 mm For cystoscope-urethro sheath Size: 19-25 Charr. 42.0358a Biopsy Alligator Forceps, down double action jaws For cystoscope-urethro sheath Size: 19-25 Charr. I-06 URO 405
  • 37. Urology Working Units/ Resectoscope Sheaths Working Unit Resectoscope (passive) Working Unit Resectoscope (active) • On standby state the electrode is inside the • On standby state the electrode is outside the resectoscope sheath resectoscope sheath • Exactly retractable with a touch of the finger • Exactly retractable with a touch of the finger • Electric cable supply with double socket • Electric cable supply with double socket 51.0384b Working Unit Resectoscope (passive) 41.0479b Working Unit Resectoscope (active) Resectoscope Sheath 26 Charr. Rotatable Resectoscope Sheath 26 Charr. for continuous suction and irrigation including: for continuous suction and irrigation including: • 1 exterior tube 26 Charr. (51.0519b), • 1 exterior tube 26 Charr. (51.0520b), 1 fix stop cock, lateral irrigation connection 1 fix stop cock, lateral irrigation connection for for optimum irrigation optimum irrigation, with perforation and ceramic • Large window at distal end insulation • Atraumatic tip • Large window at distal end • Lockable to inner tube • Atraumatic tip • 1 inner tube 24 Charr. (51.0517b), • Lockable to inner tube with 1 fix stop cock for optimum irrigation, • 1 inner tube 24 Charr. (51.0518b), insulated and coated, lockable to exterior tube with 1 fix stop cock for optimum irrigation, and working unit insulated and coated, lockable to exterior tube • Obturator 24 Charr. (51.0382b), blunt and working unit • Obturator 24 Charr. (51.0382b), blunt 51.0319b Resectoscope Sheath 26 Charr. 51.0320b Resectoscope Sheath 26 Charr. rotatable A particular characteristic of this sheath is the rotata- ble connection between the inner and outer sheath. Therefore it is possible to turn the resectoscope without moving the outer sheath, whereby the risk of postoperative strictures is remarkably reduced. URO 406 I-06
  • 38. Urology Resectoscope Sheaths/Electrodes Monopolar Electrodes 24 Charr. Resectoscope Sheath 24 Charr. fitting to all Schölly working units for irrigation, consisting of: • 1 metal sheath (42.0210b), 51.0390b Vaporisation electrode with rinsing stop cock, oblique sheath end • 1 obturator (51.0382b), blunt 51.0385b Cutting loop electrode, 30° angled, for 12° and 30° scope 42.0200b Resectoscope Sheath 24 Charr. 51.0391b Cutting loop electrode, straight 42.0370b Visual Obturatorr 24 Charr. 51.0386b Coagulation electrode, pointed For resectoscope sheaths item no.: 51.0319b 51.0320b 51.0387b Ball electrode 3 mm 42.0200b 42.0400b 51.0392b Ball electrode 5 mm 42.0371b Obturator deflectable, 24 Charr. 51.0388b Knife electrode For resectoscope sheaths item no.: 51.0319b 51.0320b 42.0200b 42.0400b 51.0393b Spike electrode 3 mm Monopolar Cable, 3 m for 51.0701b Band electrode, lengthwise fluted 05.0641r HF-unit Storz/Erbe, 51.0702b Cutting loop electrode, 0°, 24 Charr. Resectoscope Schölly 51.0703b Ball electrode, 3 mm 51.0704b Vaporisation electrode, 5 mm 51.0389b Scraper, blunt 05.0642r HF-unit Valleylab, for currentless use Resectoscope Schölly 05.0643r HF-unit Martin, 51.0330b Cutting loop electrode, 90° angled Aesculap, Berchtold for 0° and 12° endoscope Resectoscope Schölly I-06 URO 407
  • 39. Urology Urethrotome Sheath and Accessories Urethrotome Sheath 21 Charr. 42.0452a Examination Insert 5 Charr., Visual urethrotome for transurethral treatment of with 1 working channel strictures with FlexiLux scope item no. 41.0049a 42.0453a Additional Sheath, laterally open, for insertion of balloon catheter 42.0450a Urethrotome Sheath 21 Charr. incl. obturator 42.0451a For working element item no.: 51.0384b 41.0479b 42.0455b Stricture Knife, straight 42.0454a Additional Sheath for irrigation and suction 42.0457b Stricture Knife, straight with wavy edge 42.0451a Obturator for urethrotrome sheath 42.0458b Stricture Knife, round item no.: 42.0450a 42.0465b Stricture Knife, hook-shape 42.0459a Ellik Evacuator 42.0470b Stricture Knife, ring-shape 42.0460a Hose Section with cone 42.0461a Locking with LO URO 408 I-06
  • 40. Urology Mini Uretero-Renoscopes 6.0 Charr. 6 Charr. Mini Uretero-Renoscope with laterally staggered ocular part • Atraumatic distal end • Optional bridge for ultrasonic/electrohydraulic • Image bundle with 17,000 pixels probes, e.g. EMS • Semi-flexible sheath • Working bridge with quick coupling, compatible to system Wolf • Possibility of placing instruments with sufficient irrigation • Fixfocus • Large depth of field Working diameter: distal 6.0 Charr. first step 7.5 Charr. Working channel: 1 x 4 Charr., or 2 x 2.4 Charr. Viewing direction: 8° to working channel Field of view: 100° 41.0614a.wol Mini Uretero-Renoscope Working length: 425 mm 41.0615a.wol Mini Uretero-Renoscope Distal First step 6.0 Charr. 7.5 Charr. Working length: 310 mm 41.0610 Adapter for EMS lithotriptor I-06 URO 409
  • 41. Urology Compact Uretero-Renoscopes 7.5 Charr. 7.5 Charr. Compact Uretero-Renoscope 7.5 Charr. Compact Uretero-Renoscope with straight ocular part with laterally staggered ocular part • Atraumatic distal end • Atraumatic distal end • Image bundle with 30,000 pixels • Image bundle with 30,000 pixels • Semi-flexible sheath • Semi-flexible sheath • Possibility of placing instruments • Possibility of placing instruments with sufficient irrigation with sufficient irrigation • Large depth of field • Large depth of field • Optional bridge for ultrasonic/electrohydraulic probes, e.g. EMS • Working bridge with quick coupling, compatible to system Wolf • Fixfocus Working diameter: distal 7.5 Charr. Working diameter: distal 7.5 Charr. first step 9.8 Charr. first step 9.8 Charr. Working channel: 1 x 5 Charr. o. 2 x 3 Charr. Working channel: 1 x 5 Charr. or. 2 x 3 Charr. Viewing direction: 8° to working channel Viewing direction: 8° to working channel Field of view: 85° Field of view: 85° 41.0613a Uretero-Renoscope 41.0609a.wol Uretero-Renoscope Working length: 425 mm Working length: 425 mm 41.0612a Uretero-Renoscope 41.0611a.wol Uretero-Renoscope Working length: 310 mm Working length: 310 mm Accessories see chap.: 41.0610 Adapter for EMS lithotriptor Light Source, Cameras and Accessory Flexibility of Uretero-Renoscope 6 Charr. and 7.5 Charr. 15° 15° 15° 15° 15° 15° URO 410 I-06
  • 42. Urology Flexible Instruments for URS Flexible Instruments for use with Flexible Instruments for use with Uretero-Renoscopes 6 Charr. Uretero-Renoscopes 6/7.5 Charr. Size 3 Charr./working length 600 mm Size 4 Charr./working length 600 mm 42.0013a Biopsy Forceps, flexible, double 42.0015a Biopsy Forceps, flexible, double spoon, cutting, incl. handle spoon, cutting, incl. handle 42.0012a Alligator Forceps, flexible, 42.0018a Alligator Forceps, stone street, incl. handle flexible, incl. handle and spring 42.0030a Three-Pronged Stone Grasper 42.0014a Alligator Forceps, flexible, incl. handle incl. handle 42.0020a Stone Extractor, oval, incl. handle 42.0016a Scissor, flexible, incl. handle I-06 URO 411
  • 43. Urology Flexible Instruments for URS Flexible Instruments for use with Uretero-Renoscopes 7.5 Charr. Size 5 Charr./working length 600 mm 42.0040a Biopsy Forceps, flexible, double spoon, cutting, incl. handle 42.0042a Alligator Forceps, lexible, incl. handle 42.0044a Three-Pronged Stone Grasper incl. handle 42.0046a Stone Extractor, oval, incl. handle URO 412 I-06
  • 44. Urology Veress Cannulas/Trocar Systems Veress Cannulas Silicone Valves w3020 Veress cannula with stop cock and Luer-lock; Ø 2 mm, length 100 mm 11.0298a Silicone Valve single use w3021 Veress cannula with stop cock and 1 box = 5 pieces Luer-lock; Ø 2 mm, length 120 mm System: 5.5 mm w3022 Veress cannula with stop cock and 8.0 mm Luer-lock; Ø 2 mm, length 150 mm Suitabe for item no.: 11.0299a.m2 11.0311a.m2 Trocar Systems 12.1000a.m2 Trocar sleeve with silicone valve, System 3 mm, insufflation stop cock 12.1005a.m2 Trocar with triangular tip and hollow 11.0315a Silicone Valve single use cut, system 3 mm, 1 box = 5 pieces suitable for 12.1000a.m2 System: 11.0 mm 11.0299a.m2 Trocar sleeve with silicone valve and 12.5 mm insufflation stop cock, 5.5 mm for 5 mm Suitabe for item no.: 11.0312a.m2 endoscopes and instruments. 11.0330a.m2 11.0496a.m2 Trocar with hollow cut 5.5 mm, suitable for 11.0299a.m2 11.0311a.m2 Trocar sleeve, with silicone valve and Dilatation Sets insufflation stop cock, 8 mm for 7.5 mm endoscopes and instruments. 11.0502a.m2 Trocar with hollow cut 8 mm suitable for 11.0311a.m2 s720329 Dilatation-Set 5 to 10 mm 11.0312a.m2 Trocar sleeve with silicone valve and insufflation stop cock, 11 mm for 10 consisting of guiding tube and mm endoscopes and instruments. dilatation sleeve 11.0498a.m2 Trocar with hollow cut 11 mm, s720333 Dilatation-Set 10 to 15 mm suitable for 11.0312a.m2 consisting of guiding tube and 11.0316a Safety-Trocar 11 mm, dilatation sleeve with autom. locking mechanism, suitable for 11.0312a.m2 s720323 Dilatation-Set 10 to 20 mm 11.0330a.m2 Trocar sleeve with silicone valve and consisting of guiding tube and insufflation stop cock, 12.5 mm for 12 dilatation sleeve mm endoscopes and instruments. 11.0331a.m2 Trocar with hollow cut 12.5 mm, suitable for 11.0330a.m2 Reduction Sleeves s720311 Reduction sleeve 10 to 5.5 mm s720318 Reduction sleeve 15 to 10 mm s720321 Reduction sleeve 20 to 5.5 mm s720322 Reduction sleeve 20 to 10 mm All trocars are secured against roll off. I-06 URO 413
  • 45. Urology URO Pro URO Pro Pump for Ureteroscopy • Option of automatic instruments recognition and calibration • Intravasation alarm to prevent TUR syndrome • Precise control and regulation of pressure • Easy and user-friendly operation Basics Technical Data 56.0070r 1 Ureteroscopy-pump basic unit Main supply 100-240 V~, 50-60 Hz z0101-01 1 Mains cable with German plug, 2 m Max. power input 82 V A Flow range 30-500 l/min Accessories Pressure range 15-150 mm Hg z0454-01 1 Limited use tubing set, silicone, Pressure safety 55 mm Hg inflow (20 x) Insufflation rate 1.2 l/min, 2.5 l/min, z0449-01 1 Disposable tubing set, PVC (inflow) 9.0 l/min z1406-01 1 Disposable tubing set, PVC (outflow) Dimensions (W x H x D) 360 x 145 x 300 mm Weight 6.3 kg URO 414 I-06
  • 46. Light sources, Cameras & Acessories I-06
  • 47. Content Light Sources, Cameras & Accessories Light Sources, Cameras & Accessories Page Content ACC 600 FlexiLux LED-/Halogen light sources ACC 601 FlexiLux 50 MH, FlexiLux 180X light sources ACC 602 Adapter fitting to FlexiLux 50MH, 180X ACC 603 FlexiLux 300X Xenon light source ACC 604 Light guide cables and adapters ACC 605 FlexiScope IQ101 Compact camera ACC 606 FlexiScope IQ101 Compact camera power cords ACC 607 FlexiScope C1301 camera ACC 608 FlexiScope C33001 3CCD camera ACC 609 FlexiScope 50MH light source-camera unit ACC 610 FlexiScope 50MH light source-camera unit ACC 611 FlexiScope 180X-CC light source-camera unit ACC 612 FlexiScope 180X-301 light source-camera unit ACC 613 FlexiScope 180X-3CCD light source-camera unit ACC 614 TV adapter ACC 615 Camera cable ACC 616 Peripheral units ACC 617 LCD video monitors 15”/19” ACC 618 FlexiView image archiving software ACC 619 FlexiCart video cart ACC 620 Endoscope baskets, sterisafes, eye pieces I-06
  • 48. Light Sources FlexiLux 3LED FlexiLux 3000 High Power 3 Watt LED Light Source Halogen Power Light Source Small handsome and mobile light source with roll-off Light, robust synthetic casing, continuous control of protection. Battery supplied with one 3 Volt high brightness, lateral plug-in unit for colour filter, power lithium battery. Perfect for office or in the field stackable, simple bulb exchange, longer average wor- use e.g. ENT or other applications. king life of bulb due to soft start function. Lamp type: Luxeon 3 Watt LED Colour temperature: 5,500 Kelvin (nominal) Light intensity: 35 K Lux (nominal) Lamp life: > 10,000 h (nominal) Battery: 1 x Lithium CR123A, 3 Volt Nominal power 150 W Illumin. period: approx. 110 min. Colour temperature: 3,250 Kelvin per Battery charge Light intensity: 9.2 Mio. Lux Light guide connection: compatible with ACMI Average lamp life: Step 4: 1,500 h Dimension (mm): 83 x 26 (L x ø) Step 5: 200 h Weight: 75 g Light guide connection: compatible with Schölly Dimension (W x H x D): 168 x 120 x 268 mm 05.0750led.ac FlexiLux 3LED 05.0750led.bat 2 x lithium CR123A, 3 Volt 05.0165h.240 220 - 230 Volt AC, 50/60 Hz as spare part 05.0166h.120 110 - 120 Volt AC, 50/60 Hz 05.0750led.ac.set FlexiLux 3LED, incl. 3 rechargeable 05.0167h Spare lamp 150 W halogen lithium batteries and charger as set FlexiLux 650.2 FlexiLux 250.2 H Standard Light Source High power Economy Light Source Switchable, with an integrated spare lamp. High inten- Switchable, with an integrated spare lamp. High sity, incl. iris diaphragm, low noise fan with reduced intensity, incl. iris diaphragm, powerful fan, optical air turbulence. light concentrator for optimized use of the existing light energy. Nominal power Nominal power Active position: 1 x 150 W Active position: 1 x 250 W Spare position: 1 x 150 W Spare position: 1 x 250 W Colour temperature: 3,200 Kelvin Step 1 Step 2 Light intensity: 12 mio. Lux Colour temperatur: 3,100 3,230 Kelvin Lamp life: 50 h (average) Light intensity: 5.6 7.8 Mio.Lux Connection: 115/230 V AC Lamp life: 400 100 St. switchable (50/60 Hz) Light guide connection: compatible with Schölly Light guide connection: compatible with Storz Dimension (W x H x D): 258 x 110 x 263 mm Dimension (W x H x D): 367 x 132 x 250 mm 05.0080h 115 - 230 Volt AC, 50/60 Hz 05.0082h 115 V - 230 V AC, 50/60 Hz 05.0136h Spare lamp 150 W Halogen 05.0081h Spare lamp 250 W halogen ACC 600 I-06
  • 49. Light Sources FlexiLux 50MH Very compact, light intensive metal halide light source with xenon-like colour temperature, a long lamp life and a low power consumption. • Operation control front plate ON/OFF • Nominal power 50 W metal halide • Colour temperature 4,500 Kelvin • Light output 10.5 mio. Lux • Lamp life 2.500 h (average) • Power connection 100-250 V AC, 50/60 Hz, 110 VA • Light cable connector changeable, compatible to system Storz, stepless illumination adjustment with diaphragm • Dimensions/Weight 263 x 100 x 315 mm (W x H x D) approx. 3.8 kg 05.0800mh FlexiLux 50MH, incl. Storz light guide adapter 05.0140mh Spare lamp for FlexiLux 50MH FlexiLux 180X Compact and powerful xenon light source for all needs. • Operation control front plate ON/OFF with LED indicator, lifetime (bulb) indicator • Nominal power 180 W Xenon • Colour temperature 6,000 Kelvin • Light output 25 mio. Lux • Lamp life 500 h (average) • Power connection 100-250 V AC, 50-60 Hz, 400 VA • Light cable connector Light cable connector compatible to system Storz, stepless illumination adjustment with mechanical diaphragm • Dimensions/Weight 360 x 128 x 320 mm (W x H x D) approx. 6.8 kg 05.0620x.m1 FlexiLux 180X, incl. Storz light guide adapter 05.0139x.m1 Spare lamp for FlexiLux 180X (for models as of 2004) 05.0139x Spare lamp for FlexiLux 180X (for models as of 2003) I-06 ACC 601
  • 50. Adapter Adapter suitable for Schölly FlexiLux light sources 50MH, 180X 05.0601r.st Light guide connector for Storz compatible light guides 05.0601r.sc Light guide connector for Schölly compatible light guides 05.0601r.wo Light guide connector for Wolf compatible light guides 05.0601r.ac Light guide connector for ACMI compatible light guides 05.0601r.ol Light guide connector for Olympus compatible light guides 05.0601r.dy Light guide connector for Dyonics compatible light guides ACC 602 I-06
  • 51. Light Source FlexiLux 300X High Power 300 Watt xenon light source for all applications which require a specially high quantity of light. • Operation control front plate ON/OFF with LED indicator, lifetime (bulb) indicator • Nominal power 300 W Xenon • Colour temperature 6,000 Kelvin • Light output 50 mio. Lux • Lamp life 500 h (average) • Power connection 120-240 V AC, 50/60 Hz, 850 VA, automatic change over • Light guide connector adjustable, compatible to Storz, ACMI, Wolf, Olympus, stepless illumination adjustment with mechanical diaphragm • Dimensions/Weight 360 x 140 x 260 mm (W x H x D) approx. 6.8 kg Item numbers 05.0625x FlexiLux 300X 05.0626x Spare lamp module for FlexiLux 300X I-06 ACC 603
  • 52. Light Guide Cable & Adapter Hightrans Light Cable Light cable adapters* - light source end armored and highly flexibleg (s. picture 1 ) suitable for light cables and Strain relieved by kevlar and protected by a sturdy silicone tube, guaranteed autoclavable, internal ben- 05.0100z Storz light sources ding protection at the light source end, min. 5,000 V overvoltage protection, incl. adapters for your end- oscope and light source. Please indicate when ordering 05.0102b Wolf light sources with which adapters the light cable should be delive- red. In case this information should be missing we would automatically deliver the light cable suitable for STORZ system. 05.0107r Fujinon light sources 05.0104f SCHÖLLY light sources 1 05.0106c ACMI light sources (Circon) 05.0101o Olympus light sources 05.0103o Schölly adapter for 2 3 Olympus light sources LCV-S 20, -30, -40 05.0084l Length: 1.8 m Light cable adapters* - endoscope end Fiber-Ø: 3.5 mm (s. picture 2 ) suitable for light cables and 05.0088l Length: 2.3 m Fiber-Ø: 3.5 mm 05.0108z Storz endoscope 05.0085l Length: 3.0 m Fiber-Ø: 3.5 mm 05.0086l Length: 1.8 m 05.0110b Wolf endoscope Fiber-Ø: 4.8 mm 05.0090l Length: 2.3 m 05.0112c ACMI endoscope Fiber-Ø: 4.8 mm (Circon) 05.0087l Length: 3.0 m Fiber-Ø: 4.8 mm * One adapter set included per endoscope. Same features as standard light guide, but recommen- ded for xenon light sources over 180 W: Optic Adapters (s. picture 3 ) suitable for 05.0090L HT Lenth: 2.3 m Fiber-Ø: 4.8 mm 05.0114z Storz light cable* 05.0116b Wolf light cable* 05.0115z Schölly angulated light port adapter (optimized light distribution) compatible to system Storz Screw sleeves at the optic. All Schölly endoscopes with fix integrated ACMI (Circon) compatible light guide connector. * Included in delivery of a Schölly endoscope. ACC 604 I-06
  • 53. Camera 1CCD FlexiScope IQ101 Compact CCD Camera Compact 1CCD camera system with integrated electronics in camera head. 2 camera head versions for standard endoscopes and optimized for image bundle endoscopes in combination with 2 different smartboxes (Video/ S-Video or Video/USB 2.0). Camera head Smartbox White balance/ Function key window function Video Video/USB 2.0 Optionally available as anti-Moiré version with removable TV adapter • Operation control Hand piece: White balance/window function, function key • Smartbox outputs Version video: 1 x S-Video (Y/C), 1 x Video (FBAS) Version video, USB: 1 x USB 2.0, 1 x Video (FBAS) • Camera head Image sensor: 1/3" CCD Image resolution lines: 470 (H) x 420 (V) PAL 470 (H) x 350 (V) NTSC Image resolution act. pixels: 440,000 (PAL)/380,000 (NTSC) Light sensitivity: 2 Lx/f = 1.4 Endoscope coupler: Standard eye piece, C-mount, detachable Focal length TV adapter: f = 23 mm Versions: with/without integrated anti-Moiré filter • Disinfection/Sterilisation Camera head soakable in liquids, suitable for disinfection • System Acc. guideline Med. Prod. 93/42 EWG Class 1 Electromagn. compatibility: EN 60601-1 Classification: BF/CE mark Power connection: 100-240 V AC, 50/60 Hz Power consumption: 2 VA Separat power supply • Dimensions/Weight Smartbox: 80 x 34 x 170 mm (W x H x D) Camera head: 135 x 50 mm (L x ø) Camera cable: 3m Weight smartbox: max. 200 g Weight camera head: 300 g I-06 ACC 605
  • 54. Camera 1CCD Item numbers 95.2050s.CC Flexiscope IQ101 Compact, PAL 95.2050s.CC.DIG Flexiscope IQ101 Compact, PAL, USB 2.0, FlexiView 95.2053s.CC FlexiScope IQ101 Compact anti-Moiré, PAL 95.2053s.CC.DIG FlexiScope IQ101 Compact anti-Moiré, PAL, USB 2.0, FlexiView NTSC versions available on request. The FlexiView software for simple image recording and storage is included in delivery of cameras with USB 2.0 interface. Power cords has to be ordered separately together with chosen camera! 05.0700r.cord.eu Power cord Euro CEE 7/7 05.0700r.cord.indaf Power cord India/Africa BS 546 05.0700r.cord.uk Power cord UK BS 1363 05.0700r.cord.na Power cord USA Medical grade 05.0700r.cord.jap Power cord Japan JIS 8303 05.0700r.cord.chi Power cord China GB2099.1 Without anti-Moiré Filter With anti-Moiré Filter The anti-Moiré filter provides opti- mization of image quality at appli- cation of image bundle endo- scopes are used. It reduces arte- facts significantly. ACC 606 I-06
  • 55. Camera 1CCD FlexiScope C1301 Camera Fine adjustable 10 bit 1CCD camera with 3 presettings. Camera head, bent Camera head, straight Camera head with self-adjusted TV adapter (for Resectoskope applications) • Operation control ON/OFF with LED indicator, white balance, window function, preset function with three selectable basic setups - all with OSD/LED indicator, contrast/brightness adjustment with OSD indicator • Camera controller Outputs: 1 x S-Video (Y/C), 1 x Video (FBAS) • Camera head Image sensor: 1/2" CCD Image resolution lines: 470 (H) x 420 (V) PAL 470 (H) x 350 (V) NTSC Image resolution act. pixels: 440.000 (PAL)/380.000 (NTSC) Light sensitivity: 2 Lx/f = 1.4 Endoscope coupler: Standard eye piece, C-mount, detachable Focal length TV adapter: f = 30 mm, with integrated anti-Moiré filter • Disinfection/Sterilisation Camera head soakable in liquids suitable for disinfection; compatible to Steris® • System Acc. Guideline Med. Prod. 93/42 EWG Class 1 Electromagn. compatibility: EN 60601-1 Classification: BF/CE mark Power connection: 100-240 V AC, 50/60 Hz Power consumption: 25 VA • Dimensions/Weight Camera station: 360 x 88 x 320 mm (W x H x D) Weight: approx. 4 kg Camera head and adapter: approx. 140 x 60 mm (L x ø) Camera cable: 3m Item numbers 95.2007s.C1 FlexiScope C1301 with Camera head, straight, PAL 95.2008s.C1 FlexiScope C1301 with Camera head, bent, PAL 95.2015s.C1 FlexiScope C1301 with Camera head, self-adjusted TV adapter, PAL NTSC versions available on request. I-06 ACC 607
  • 56. Camera 3CCD FlexiScope C33001 3CCD Camera Fine adjustable 3CCD camera with 3 preset programs - individually to customize by user. White balance Function key • Operation control ON/OFF with LED indicator, white balance, window function, preset function with three selectable basic setups - all in OSD menu modifiable, brightness adjustment with OSD indicator Camera head: white balance, function key • Camera controller Outputs: 1 x RGB Sub-D 2 x S-Video (Y/C) 1 x Video (FBAS) 1 x 3.5 mm cinch for remote control • Camera head Image sensor: 3 x 1/3" CCD Image resolution lines: 750 (H) x 430 (V) PAL 750 (H) x 350 (V) NTSC Image resolution act. pixels: 440,000 (PAL)/380,000 (NTSC) Light sensitivity: 5 Lx/f = 2.2 Endoscope coupler: Standard eye piece, C-mount, detachable Focal length TV adapter: f = 23 mm • Disinfection/Sterilisation Camera head soakable in liquids, suitable for disinfection, compatible to Steris® and Sterrad® • System Acc. guideline Med. Prod. 93/42 EWG Class 1 Electromagn. compatibility: EN 60601-1 Classification: BF/CE mark Power connection: 100-250 V AC, 50/60 Hz Power consumption: 25 VA • Dimensions/Weight Camera station: 360 x 88 x 320 mm (W x H x D) Weight: approx. 4.1 kg Camera head and adapter: 165 x 50 mm (L x ø) Camera cable: 3m Item number 05.9090s.m1 FlexiScope C33001 NTSC versions available on request. ACC 608 I-06
  • 57. Light Source-Camera Unit FlexiScope 50MH - Light Source-Camera Unit The FlexiScope 50MH incorporates the compact, easy-to-use 1CCD Camera IQ101 Compact, combined with a compact high intensity metal halide light source. The new metal halide lamp technology guarantees a high light intensity with a low power consumption as well as a xenon-like colour temperature and a long lamp life. The elec- tronic, which is integrated in the camera head offers an optimized image quality. Optional, a digital USB 2.0 inter- face with an easy-to-handle picture recording software (FlexiView) is available. For application with image bundle endoscopes, we recommend the optional available version with integrated anti-Moiré filter. Function key White balance/ Window function • Camera Operation control: White balance/window function, function key • Camera controller Outputs: 1 x S-Video (Y/C), 1 x Video (FBAS) 1 x USB 2.0 (optional) • Camera head Image sensor: 1/3" CCD Image resolution lines: 470 (H) x 420 (V) PAL 470 (H) x 350 (V) NTSC Image resolution act. pixels: 440,000 (PAL)/380,000 (NTSC) Light sensitivity: 2 Lx/f = 1.4 Endoscope coupler: Standard eye piece, C-mount, detachable Focal length TV adapter: f = 23 mm Versions: w/o integrated anti-Moiré filter • Disinfection/Sterilisation Camera head soakable in liquids, suitable for disinfection I-06 ACC 609
  • 58. Light Source-Camera Unit • Data light source ON/OFF Light guide connector (changeable) compatible with system Storz, stepless illumination adjustment with diaphragm Nominal output: 50 W metal halide Colour temperature: 4,500 Kelvin Light output: 10.5 mio. Lux Lamp life: 2,500 h (average) • System Acc. guideline Med. Prod. 93/42 EWG Class 1 Electromagn. compatibility: EN 60601-1 Classification: BF/CE mark Power connection: 100-250 V AC, 50/60 Hz, 110 VA • Dimensions/Weight: Housing: 263 x 100 x 315 mm (W x H x D) Weight: 4 kg Camera head: approx. 135 x 50 mm (L x ø) Camera cable: 3m Item numbers 95.1011mh FlexiScope 50MH; 50 W LS. + Compact Camera, PAL 95.1011mh.a FlexiScope 50MH; 50 W LS. + Compact Camera, PAL, anti-Moiré 95.1011mh.d FlexiScope 50MH; 50 W Lv. + Compact Camera, PAL, USB 2.0, FlexiView 95.1011mh.a.d FlexiScope 50MH; 50 W LS. + Compact Camera, PAL, anti-Moiré, USB 2.0, FlexiView 05.0140mh Spare lamp metal halide NTSC versions available on request. The FlexiView software for simple image recording and storage is included in delivery of cameras with USB 2.0 interface. ACC 610 I-06
  • 59. Light Source-Camera Unit FlexiScope 180X-CC - Light Source-Camera Unit The FlexiScope 180X-CC incorporates a Schölly IQ101 Compact Camera - a compact 1CCD camera system, combined with a high intensity 180 W xenon light source for maximal light intensity. The electronics, which is integrated in the camera head offers an optimized image quality. For application with image bundle endoscopes, we recommend the optional available version with integrated anti-Moiré filter. Function key Withe balance/ Window function • Operation control Camera head: White balance/window function, function key • Camera controller Outputs: 1 x S-Video (Y/C), 1 x Video (FBAS), USB 2.0 (only digital version), remote output • Camera head Image sensor: 1/3" CCD Image resolution lines: 470 (H) x 420 (V) PAL 470 (H) x 350 (V) NTSC Image resolution act. pixel: 440,000 (PAL)/380,000 (NTSC) Light sensitivity: 2 Lx/f = 1.4 Endoscope coupler: Standard eye piece, C-mount, detachable Focal length TV adapter: f = 23 mm • Disinfection/Sterilisation Camera head soakable in liquids, suitable for disinfection • Data light source ON/OFF with LED indicator, lifetime (bulb) indicator, Nominal output: 180 W xenon Colour temperature: 6,000 Kelvin Light output: 25 mio. Lux Lamp life: 500 h (average) Light guide connector: compatible to system Storz, stepless illumination adjustment with mechanical diaphragm • System Acc. guideline Med. Prod. 93/42 EWG Class 1 Electromagn. compatibility: EN 60601-1 Classification: BF/CE mark Power connection: 100-250 V AC, 50-60 Hz, 400 VA • Dimensions/Weight Housing: 360 x 128 x 338 mm (W x H x D) Weight: 7.1 kg Camera head: 135 x 50 mm (L x ø) Camera cable: 3m Item numbers 95.1008x FlexiScope 180X-CC; 180 W Xenon LS. with Compact Camera, PAL 95.1008x.DIG FlexiScope 180X-CC; 180 W Xenon LS. with Compact Camera, PAL, USB 2.0, FlexiView 95.1009x FlexiScope 180X-CC; 180 W Xenon LS. with Compact Camera, PAL, anti-Moiré 95.1009x.DIG FlexiScope 180X-CC; 180 W Xenon LQ. with Compact Camera, PAL, USB 2.0, anti-Moiré, FlexiView NTSC versions available on request. The FlexiView software for simple image recording and storage is included in delivery of cameras with USB 2.0 interface. I-06 ACC 611
  • 60. Light Source-Camera Unit FlexiScope 180X-301 - Light Source-Camera Unit FlexiScope 180X-301 - the combination, includes a fine adjustable 10 bit 1CCD camera and light intensity xenon light source. • Operation control White balance, window function, preset function with three selectable basic setups - all with OSD/LED indicator, contrast/brightness adjustment with OSD indicator • Camera controller Outputs: 1 x S-Video (Y/C), 1 x Video (FBAS) • Camera head Image sensor: 1/2" CCD Image resolution lines: 470 (H) x 420 (V) PAL 470 (H) x 350 (V) NTSC Image resolution act. pixels: 440,000 (PAL)/380,000 (NTSC) Light sensitivity: 2 Lx/f = 1.4 Endoscope coupler: Standard eye piece, detachable C-mount over adapter Focal length TV adapter: f = 30 mm integrated anti-Moiré filter • Disinfection/Sterilisation Camera head soakable in liquids, suitable for disinfection, compatible to Steris® • Data light source with LED indicator, lifetime (bulb) indicator Nominal output: 180 W xenon Colour temperature: 6,000 Kelvin Light output: 25 mio. Lux Lamp life: 500 h (average) Light guide connector: compatible to system Storz, stepless illumination adjustment with mechanical diaphragm • System Acc. guideline Med. Prod. 93/42 EWG Class 1 Electromagn. compatibility: EN 60601-1 Classification: BF/CE mark Power connection: 100-250 V AC, 50-60 Hz, 400 VA • Dimensions/Weight: Housing: 360 x 128 x 338 mm (W x H x D) Weight: 7.4 kg Camera head: approx. 140 x 60 mm (L x ø) Camera cable: 3m Item numbers 95.1005x FlexiScope 180X-301; 180 W Xenon LS. with Camera C1301, straight, PAL 95.1006x FlexiScope 180X-301; 180 W Xenon LS. with Camera C1301, bent, PAL 95.1007x FlexiScope 180X-301; 180 W Xenon LS. with Camera C1301, self-adjusted TV adapter, PAL NTSC versions available on request. ACC 612 I-06
  • 61. Light Source-Camera Unit FlexiScope 180X-3CCD - Light Source-Camera Unit FlexiScope 180X-3CCD, the combination of a high intensity xenon light source and a fine adjustable 3-chip camera. To allow digital archiving of camera images, this unit is equipped with a modern USB 2.0 interface for direct connection to a standard PC. 3 preset programs - individually to costumize by user. White balance Function key • Operation control White balance, window function, preset function with three selectable basic setups - all in OSD menu modifiable, brightness adjustment with OSD indicator Camera head: white balance, function key • Camera controller Outputs: 1 x RGB Sub-D 1 x S-Video (Y/C) 1 x Video (FBAS) 1 x USB 2.0 1 x 3.5 mm cinch for remote control • Camera head Image sensor: 3 x 1/3" CCD Image resolution lines: 750 (H) x 430 (V) PAL 750 (H) x 350 (V) NTSC Image resolution act. pixels: 440,000 (PAL)/380,000 (NTSC) Light sensitivity: 5 Lx/f = 2.2 Endoscope coupler: Standard eye piece, C-mount, detachable Focal length TV adapter: f = 23 mm • Disinfection/Sterilisation Camera head soakable in liquids, suitable for disinfection, compatible to Steris® and Sterrad® • Data light source ON/OFF with LED indicator, lifetime (bulb) indicator, connector for light cable adapter system Storz, stepless illumination adjustment with mechanical diaphragm Nominal output: 180 W xenon Colour temperature: 6,000 Kelvin Light output: 25 mio. Lux Lamp life: 500 h (average) • System Acc. guideline Med. Prod. 93/42 EWG Class 1 Electromagn. compatibility: EN 60601-1 Classification: BF/CE mark Power connection: 100-250 V AC, 50-60 Hz, 400 VA • Dimensions/Weight Housing: 360 x 150 x 338 mm (W x H x D) Weight: 8.3 kg Camera head: 165 x 50 mm (L x ø) Camera cable: 3m Item numbers 95.1010x.DIG FlexiScope 180X-3CCD; 180 W Xenon LS. with Camera C33001, USB 2.0, FlexiView NTSC versions available on request. The FlexiView software for simple image recording and storage is included in delivery of cameras with USB 2.0 interface. I-06 ACC 613
  • 62. TV Adapter TV Adapter for cameras with C-mount TV Adapter for FlexiScope C1301/180X-301 With C-mount for all camera heads and quick coupler Direct coupling to the camera modules C1301/180X- for all endoscopes with eye piece (ACMI/BS); 301 and all endoscope eye pieces; incl. focusing, with quick coupler and retaining screw. incl. focusing, with anti-fogging holes and retaining Low weight with anti-fogging holes. screw for endoscope eye piece, low weight. Sterilization: soaking and gas. Sterilization: Soaking and gas. Standard TV Adapter FlexiScope Camera TV Adapter * ** 95.2010s TV adapter: f = 25 mm 95.2011s TV adapter: f = 30 mm 05.0062s TV adapter: f = 18 mm ** 05.0067s.M2 TV adapter: f = 25 mm * 05.0064s.M2 TV adapter: f = 30 mm * 05.0066s.M2 TV adapter: f = 40 mm * Self-adjusted Camera TV Adapter for FlexiScope C1301/180X-301 Zoom TV Adapter This TV adapter avoids the problem of the „leaning image“ in case of rotated endoscope. With this With C-mount for all camera heads and quick coupler “Pendulum”- construction, the TV-adapter ensures an for all endoscopes with eye piece (ACMI/BS); always upright orientation picture, even if the end- incl. focusing, with quick coupler and retaining screw. oscope is turned during the procedure. Quick coupler Low weight with anti-fogging holes. with retaining screw. Sterilization: soaking and gas. „Pendolino“ 95.2014s Self-adjusted camera TV adapter f = 30 mm, only for camera head C1301/180X-301. 05.0063s Zoom TV Adapter f = 18 - 50 mm, with C-mount, Sterilization: soaking and gas. C - mount Adapter for FlexiScope C1301/180X-301 95.2012s C-mount Adapter for C1301/180X-301 Image size on the screen with 1/2'' CCD camera Image size on the screen with 1/3'' CCD camera ! ! ! ! ! ! ! ! f = 18 mm f = 25 mm f = 30 mm f = 40 mm f = 18 mm f = 25 mm f = 30 mm f = 40 mm standard standard Base: Endoscope Ø 4 mm Base: Endoscope Ø 4 mm ACC 614 I-06
  • 63. Camera Cable 05.9105k Video Cable (FBAS) 2 m with BNC plug 05.9102k S-Video (Y/C) Cable 2 m with mini hosiden 05.9090s.v Remote control cable between camera remote output and video peripheral units 3.5 mm phone jack at cinch (RCA) plug I-06 ACC 615
  • 64. Peripheral Units MediCapture MediCapture captures and stores digital images on USB flash drive from your existing camera equipment works with existing endoscopes, surgical microscopes, etc. System PAL and NTSC (switch selectable) Inputs/Outputs S-Video or composite BNC Power 100 - 240 V AC Foot switch (optional) Hands-free capture, standard 3.5 mm mini jack Media MediCapture brand USB flash drives (required) Image formats DICOM, DICOM True Color, JPG, BMP PCX color, PCX greyscale , Image size 800 x 600 pixels Environmental Storage: - 40° to + 85° Operating: - 20° to + 40° Dimensions (mm) 240 x 63 x 200 (W x H x D) Certifications UL, FCC, CE Kit contents MediCapture, USB flash drive, power cable, user guide Item numbers 05.9190v MediCapture 05.9191v USB MediCap100 extender stick 05.9192v Foot switch for MediCapture 05.9070v DVD Recorder DVO-1000MD-Sony 05.9180p Colour Video Printer UP21MD - SONY Recording system: DVD recording, Print technology: Colour thermo-sublimation NTSC/PAL switchable Resolution: 403 dpi (1664 pixels) Video recording format: MPEG-2 Paper size: A6 Playable media: DVD + RW Image storage: 4 image storage Video input: 2 x S-Video (Y/C, mini DIN) Remote control: 3.5 mm mini plug 2 x Video (FBAS, BNC) Video In-/Output: Video, S-Video, RGB Remote: 1x RS-232C Power consumption: 240 VA 2 x Stereo mini plug Power supply: 120/240V, 50/60 Hz 1 x USB 2.0 Dimension (Wx H x D): 212 x 125 x 395 mm Power supply: 100-240 V AC, 50/60 Hz Weight: approx. 6.5 kg Power consumption: 35 VA Safety tests: UL2601-1, CSA, Dimension (Wx H x D): 212 x 128,5 x 382 mm EN60601-1, CE Weight: 6 kg 05.9281r Paper + Toner for Sony UP21MD - SONY 1 Package = 240 sheets ACC 616 I-06
  • 65. Monitors LCD Video Monitors 15''/ 19'' Daten 15'' 19'' Visible area 304 x 228 mm 376 x 301 mm Dimensions (Wx H x D) 385 x 309 x 80 mm 465 x 400 x 98 mm Weight 4.8 kg 6.8 kg Colours 16.8 mio. 16.8 mio. Greyscales 256 256 Resolution 1,024 x 768 XGA 1,280 x 1,024 SXGA Viewing angle (H/V) 170°/170° 170°/170° Brightness 430 cd/m2 350 cd/m2 Contrast ratio 500 : 1 650 : 1 Response time 10-16 ms 10-16 ms Nominal voltage display 16-24 VDC (100-240 V AC) 16-24 VDC (100-240 V AC) Power input 40 W 60 W Video through Yes Yes Input - Video (FBAS, BNC) - Video (FBAS, BNC) - S-Video - S-Video (Y/C, mini-DIN or 2 x BNC) (Y/C, mini-DIN or 2 x BNC) - Component Video - Component Video (RGB, 5 x BNC or HD 15) (RGB, 5 x BNC or HD 15) - VGA (VGA, HD 15) - VGA (VGA, HD 15) Output - Video (FBAS, BNC) - Video (FBAS, BNC) - S-Video (Y/C, mini-DIN) - S-Video (Y/C, mini-DIN) - Component Video - Component Video (RGB, 5 x BNC oder HD 15) (RGB, 5 x BNC oder HD 15) Overscan Yes Yes VESA compatible 100 100 Item numbers 05.9032m 15” LCD Video monitor with medical authorization, with RGB 05.9033m 19” LCD Video monitor with medical authorization, with RGB I-06 ACC 617
  • 66. Software FlexiView - Software for Image Archiving Developed as a specially easy and user-friendly desktop. Picture recording per mouse click,alternative via camera function key live Open picture overview Video settings Program options Quad split view Main screen: Full screen view live video image, last 4 stored images, settings for folder, file name, file number. Description Opening the pictures with available image processing programs Standard version included in the delivery of cameras with USB 2.0 interface DirectX/Direct Show compatible Executable on WIN2000 (SP4) and XP (SP1) Remote control via camera function key (in connection with Schölly camera systems with dig. USB 2.0 output and PC 2 GHz or more.) FlexiView Video Grabbing System: Developed as accessory for all Schölly cameras without digital USB 2.0 interface. Item no. Description 95.2070.dig Smartbox, foot switch, video- /foot pedal connecting cable, USB cable, Driver software and FlexiView software ACC 618 I-06
  • 67. Flexi Cart Flexi Cart For easy handling and for transport purposes, a multi functional OP-Cart - FlexiCart - is available. FCW.MED40.1 Flexi Cart consisting of: • Basis cart 40E/width 500 mm • 4 double free rotating rolls 100 mm • 1 layer with handle • 4 layers standard • 1 lockable drawer • 2 power profiles 40E • 1 multiplug socket 6 x • Surface RAL 7035 light grey • Decoration elements RAL 5012 light blue FCW.GH.1 FlexiCart gas bottle holder For lateral fixation of customary gas bottles with max. diameter of 145 mm. FCW.TT.1 FlexiCart option safety transformer • Isolating transformer 1,600 VA • ISO Max isolation keeper • Cold unit extension lead 8-fold with one POAG plug each and one fuse per socket instead of a normal extension lead • roll set Ø 125 mm, conductible 05.0700r.cord.cart Power connector cable Power connector cable between Schölly cameras, insufflators or light sources and the option safety transformer extension lead • Length 1.8 m • Straight I-06 ACC 619
  • 68. Baskets / Sterisafe / Ocular Funnel Endoscope Baskets 02.0050a Sterisafe E42 Whether it is a matter of cleaning, sterilizing, storage or transport, the endoscope basket offers secure pro- tection for the sensitive endoscopes against damage. The endoscope baskets are made of chrome nickel steel, are electrolytically polished, free of burs manu- factured and have closed wire strap. The removable cover equipped with a special rotata- ble adapter made of high-grade synthetic material protects against self-opening. Plugged-on silicone store elements guarantee an opti- Dimension (mm): 440 x 107 x 71 mal fixation of your endoscopes during the washing (W x H x D) and sterilizing process. The outer contours of the basket are arranged with- Spare parts for Sterisafe: out overhang edges and create excellent conditions 02.0060a Silicone-insert (7- pieces) for shrink-wrap of baskets. A clean solution for stora- ge and transport of endoscopes after sterilization. 02.0070a Filter 02.0080a Date insert 02.0090a Seal with indication point (2,000 - pieces) 02.0010a Endoscope Basket with cover 02.0091a Safety lead seal 02.0095a PST Steritray + Silicone mat for Arthroscopes and Sinuscopes Dimensions (mm): 290 x 80 x 52 (W x H x D) 02.0020a Endoscope Basket with cover for flexible mini endoscopes Dimensions (mm): 265 x 45 x 160 (W x H x D) Eye Pieces for Laparoscopes, Cystoscopes, Hysteroscopes etc. Dimensions (mm): 460 x 80 x 52 (W x H x D) 02.0030a Endoscope Basket with cover 21.0550a Eye Piece for endoscopes of Ø outer: 2.7 mm - 6.5 mm Ø 18 mm 21.0551a Eye Piece for endoscopes of for Laparoscopes, Cystoscopes, Ø outer: 2.7 mm - 6.5 mm Hysteroscopes etc. Ø 20 mm Dimensions (mm): 670 x 80 x 52 21.0560a Eye Piece (W x H x D) for endoscopes of Ø outer: 10 mm Ø 19.2 mm ACC 620 I-06
  • 69. FlexiFairplay Worldwide Service Germany-trained national competence with Schölly technology Service Denzlingen I-06 SER 701
  • 70. FlexiFairplay Worldwide Service Your advantages with a „Schölly licensed Service Partner“: • Same quality standards worldwide • Centralized spare parts management for service centers • Online know-how transfer by Schölly • Identical test devices, supplied by Schölly • Centralized data base with technical specifications and working instructions for use • Training for all service partners in Denzlingen/Germany Service Centers USA Saudi Arabia Korea Russia India China Australia Japan Brazil SER 702 I-06
  • 71. FlexiFairplay Service is our obligation to you As a manufacturer we have the possibility to offer a comprehensive service range, which is more than an common repair. At Schölly Fiberoptic you decide which of our service versions should be applied at the repair of your endoscopes. ClassicRepair • Repair if cheaper and safe, • Exchange if necessary FlexiFairplay FlexiLine 8 Best Prices 8 Market Share 8 Win-Win Situation A new weapon to win market share ConsiStock • Winning through response time • Immediate exchange is key to success Have in mind: 70% of the future endoscopy business will be service. I-06 SER 703
  • 72. FlexiFairplay ClassicRepair ClassicRepair Repair if cheaper and safe - Exchange if necessary! „ Schölly repairs or exchanges 90 % of all rigid medical scopes “ With our well established ClassicRepair program you can offer your customers a fair and transparent service. You may rest assured, 90 % of all rigid surgical endoscopes can be repaired or exchanged. With the experience of 60,000 repaired scopes we really know what we are talking about. Send us the damaged scopes and we offer you: Repair if cheaper and safe Exchange if necessary Four different repair levels keep the program easy and straightforward. Detailed cost estimate reports and service reports with images before / after repair as well as our quality management system gives you full traceability of all repairs. And we guarantee fast transactions, local pricing due to more than 20 licensed or Schölly owned repair centers and the ambition to have the same quality standard world- wide. Don't wait and leave the service business to the others Start today with the ClassicRepair program! Come and fly with us! I-06 SER 709
  • 73. FlexiFairplay ClassicRepair ClassicRepair (Nose-Pharyngoscope/Uretero-Renoscope) Repair if cheaper and safe - Exchange if necessary! „ 70 % of future endoscopy business will be service “ With our well established ClassicRepair program you can offer your customers a fair and transparent service. With the experience of 60,000 repaired scopes we really know what we are talking about. Send us the damaged scopes and we offer you: Repair if cheaper and safe Exchange if necessary Four different repair levels keep the program easy and straightforward. Detailed cost estimats and service reports with images before / after repair as well as our quality management system gives you full traceability of all repairs. And we guarantee fast transactions, local pricing due to more than 20 licensed or Schölly owned repair centers and the ambition to have the same quality standard worldwide. Don't wait and leave the service business to the others Start today with the ClassicRepair program! Come and fly with us! I-06 SER 711
  • 74. FlexiFairplay ClassicRepair ClassicRepair (Nose-Pharyngoscope/Uretero-Renoscope) Repair if cheaper and safe - Exchange if necessary! Maintenance Repair save and Repair save and Repair or Repair levels Schölly cheaper cheaper exchange Exchange Nose-Pharyngoscope Level 0 Level A Level B Level C Action Cleaning and sterilization into new Schölly Nose-Pharyngoscope Incoming inspection & damage analysis Repair of fiber optics (distal and proximal) You receive a Replacement of eye piece brand new Schölly endoscope suitable Replacement of ocular/ for your diaphragm instruments Replacement of objective Replacement of image guide incl. objective with a warranty of Replacement of tubing 12 months. Replacement of tip mechanics Replacement of fiber optics Your defect or old New adjustment according scope is accepted in specification payment. Leak test Service Report & Warranty Certificate Maintenance Repair save and Repair save and Repair or Repair levels Schölly cheaper cheaper exchange Exchange Uretero-Renoscope Level 0 Level A Level B Level C Action into new Schölly Cleaning and sterilization Uretero-Renoscope Incoming inspection & damage analysis You receive a Cleaning and polishing brand new Schölly of surface endoscope suitable Cleaning of fiber optics, for your glueing and polishing instruments Dismantling and cleaning of ocular system Replacement of eye piece with a warranty of Replacement of ocular/ 12 months. diaphragm Replacement of image guide incl. objectives Your defect or old Replacement of shaft scope is accepted in mechanics incl. fiber optics payment. New adjustment according specification Compatible to Leak test Schölly and Wolf. Further brands in Service Report & preparation. Warranty Certificate SER 712 I-06
  • 75. Prevention of Damage The consideration of critical areas of an endoscope helps to prevent damages. 1 Critical Area 1 Distal End 2 Critical Area 2 Endoscope sheath 3 Critical Area 3 Changeover Sheath/Main body I-06 SER 719
  • 76. Prevention of Damage Critical Areas of an Endoscope Critical parts of a scope are the optical systems, which have to withstand heavy mechanical stress depending on application: Examples: Critical Area 1: Distal end of the endoscope In this area defects can occur by shaver use and HF powered systems if these are in contact with the endoscope. This is often the case in orthopedic and gynecological applications. Critical Area 2: Endoscope sheath Sometimes heavy damages occur at the endoscope sheath if the scope is wrongly inserted in a working channel. The longer the working length of the endoscope is, the higher the risk is for such damage. Damage often occurs when the scope is inserted into the sheath. If the inser- tion is not done axially but radially to the optic sheath, care should be taken during this procedure. Critical Area 3: Changeover sheath/Main body It is in most cases a consequence of the above-mentioned problem (compare critical area 2). Additionally compressions of the sheath to the main body occur what is often to attribute to improper use during decontamination. SER 720 I-06
  • 77. Assembly of Light Guide Cable Light Guide Cables Schölly light guide cables are not glued at the light source end but compressed and optically treated. They are able to withstand breakdown voltages of 5 kV and temperatures up to 300°C. Optical fibers Silicone tube Steel thread Nylon protection Bending radius Chain reactions may occur - especially if the light entrance area is damaged. Example: The capillary space between the fibers of the most used endoscopes are polished, ground and filled in with the appropriate medical adhesive. Cleaning with common cleaning procedures ==> Washouts in the spaces between the fibers ==> Extension of the surface at the point of incidence ==> Disproportionate heating at the input through the extended surface ==> Burns at the distal end with significant loss of transmission and change of colour ==> Gas evolution of adhesive residues I-06 SER 721
  • 78. Reviewing of Light Guide Cable Picture of a light guide at delivery Gives optimum of illumination Sectional fiber breakage (black faces) Reduced illumination Distributed fiber breakage Most of the fibers are broken Out burned light guide Fibers are melted = unusable We recommend the exchange of a light guide as soon as more than 50% of the fibers are broken. SER 722 I-06
  • 79. Technology Sterilization Sterilization - Our Main Competence All Schölly endoscopes with AUTOCLAVE mark are according to WHO-recom- mendation suitable for steam sterilization - 18 min. at 134 °C/273 °F. Since the outbreak of the Creutzfeldt-Jakob disease, many scientists have been busy to find out how to avoid the risk of transmission of the Spongiform Encephalopathy (Creutzfeldt-Jakob Disease, or BSE) during invasive operations particularly in the field of neurosurgery, spinal surgery or in case of oph- thalmological surgical operations. The World Health Organisation (WHO) has now published a report with recommendations regarding the handling of surgical instruments and endoscopes in view of ste- rility (WHO/CDS/CSR/APH/2000.3 http://www.who.int/csr/en). According to this report, it is advisable to use disposable material. If not possible or too costly, the autoclaving and chemical sterilization are considered to be most effective methods in order to main- tain the heat resistance and reusability of endoscopes. In this context, the mandatory holding time with a defined maximum temperature (18-20 minutes with 134 °C) is a new and technically very com- plex requirement for rigid endoscopes. Schölly Fiberoptic GmbH, having its core competence exactly in this field, offers now all autoclavable rigid endoscopes with validation concerning this new requi- rement of 18-20 minutes with a temperature of 134 °C. As an additional innovation Schölly offers as one of few suppliers autoclavable, flexible endoscopes with a minimal diameter of 0.35 mm up. These endoscopes have an optical system with 3.000 - 50.000 pixels and additional illumination fibers for illumination. These have been specified according the requirements of the WHO. Reconditioning Compatibility of Schölly - Endoscopes New sterilization methods require a constructive consideration in scope manufacturing. In times of increased infections new sterilization methods have been developed to assure a safe and fast sterilization process. Those sterilization methods which do not have the major disadvantages of gas sterilization (residues, environmental compatibility), are finding more and more acceptance in hospitals. The adavantages are evident: • Short cycle times (usually < 75 minutes) • No cooling cycles • No toxic residues, therefore no burden for the persons in charge • Remaining humidity < 5 %, not corrosive • Virucide, sporicide, tuberculocide, bacteriozide, fungizide • Suitable for thermolabile materials, as temperature is < 56 °C • Process controlled Schölly endoscopes have shown their material compatibility for these application methods by passing several tests. The effects of the sterilizing process have to be documented by the user. TEC 800 I-06
  • 80. Technologie Sterilization STERIS® from Steris Corporation STERIS® is a „cold“ liquid sterilization. Acetic peroxide is mixed with sterile water, the instruments to be sterilized are washed with solvents. After twelve minutes of dipping the instrument in the sterili- zing solution, the solution is pumped out and the instrument is rinsed with sterile water four times. The working channel of rigid/flexible endoscopes can be attached to a pressurized fitting for sterili- zation. Precise information on www.steris.com STERRAD® from Johnson & Johnson STERRAD® is a low temperature-plasma sterilization. The hydrogen peroxide dioxide is transported from the magnetic field to the plasma phase. One cycle consists of following phases • Phase of vacuum: evacuate up to a pressure of 0.3 mbar. • Phase of injection: 2 ml liquid H2O2 are injected into the vacuum. • Phase of diffusion: app. 50 minutes are necessary for the homogeneous distribution of hydrogen peroxide in the chamber, the pressure increases to 7 - 11 mbar. • Phase of plasma (app. 20 Min.) : Production of primary plasma; secondary plasma follows; actual phase of sterilization; end products are water (H2O) and oxygen (O2). • Phase of pressure compensation: Adjustment of atmospheric pressure in the chamber. The methods of STERRAD® and STERIS® help to avoid high temperatures on optical systems. This results in a very gentle sterilization method. Nevertheless, the use of peracedic acid as well as hydro- gen peroxide may cause a more intensive wear of the endoscope surfaces (washout, bleeching effects). However, these effects do not have any influence on the lifetime of the endoscopes. It is main- ly a „cosmetical“ effect. These effects have such a minor influence on the lifetime of the endoscopes compared to the effects of high temperature methods. The effecs of the sterilizing process have to be documented by the user. All Schölly endoscopes are material compatible regarding following process: • Soaking in disinfectant which is approved for instrument disinfection • Gas sterilization: formaldehyde, ethylene oxide • STERRAD® und STERIS® methods • Autoclavation 18 - 20 minutes at 134 °C according to WHO-recommendation, see label I-06 TEC 801
  • 81. Technology Endoscopes Assembly of Endoscopes An endoscope is an optical instrument which is equipped with a light source and other optical devi- ces. It allows to illuminate and to view a visceral cavity or a hollow organ. ocular objective (image enlargement) Insulating synthetic ocular part. Stainless steel body. laser-welded fiber cone for light tight connections amplification light guide fibers • large perspective • diameter: 0.03 mm Image transfering rod lens stainless steel body, no coating Objective (picture taking) TEC 802 I-06
  • 82. Technology Why Schölly Endoscopes? 6 convincing reasons for Schölly Endoscopes 1 Proximal and distal saphir-window, scratch-resistant, no glass corrosion 1 2 2 Scope body and sheath are made of stainless steel, no coating 3 4 3 Laser-welded optical centering = hermetic sealing between optics/fiber optics 4 Laser-welded connection between body and outer tube 5 Airspaces filled with drying agent = less humidity, longer service life 5 6 Service-friendly objective; 6 most parts can be reused 1 I-06 TEC 803
  • 83. Technology Side View Objectives Side view objectives Besides endoscopes with direct view objectives (0°), some applications need 10°, 30°, 45°, 70°, 90° or 110° side view. For side view objectives, complex prism-systems are necessary. Please see the drawings of a 30° objective in detail: 30 °O bj ec tiv e TEC 804 I-06
  • 84. Technology 10 mm Laparoscopes The new generation of 10 mm laparoscopes • New construction of the distal end • Free staorage of illumination fibers • Increased life time cycle and tightness • Improved illumination • Clearly defined and homogenous light • Forwards the light exactly to the necessary point I-06 TEC 805
  • 85. 3D - Robot Surgery „Da Vinci® “ System The complete visualization part for the „Da Vinci® “ robot system has been developed in close cooperation between Intuitive and Schölly. Contents of this Schölly Solution 3D - Endoscope • Two single optical channels. • High resolution, low image distortion. • Homogeneous 4-point illumination with twin adaptation for light guide cables. • All mechanical parts in stainless steel, all connecting parts laser welded. • The optical system is calculated to see even smallest blood vessels crystal clear. 3CCD Cameras & TV adapter • 2 x 3 CCD Cameras for PAL or NTSC • The TV adapter has a motor driven zooming device. All INDIA Distributor: ENDOSYS INTERNATIONAL Mumbai +91-9820422965 Ahmedabad TEC 806 I-06 +91-9824269063