• Share
  • Email
  • Embed
  • Like
  • Save
  • Private Content
Claw© "RTM" System
 

Claw© "RTM" System

on

  • 1,377 views

The new system of Sertecpet Inc. "Claw© RTM" with the alternative of monitoring in real time.

The new system of Sertecpet Inc. "Claw© RTM" with the alternative of monitoring in real time.

Statistics

Views

Total Views
1,377
Views on SlideShare
1,377
Embed Views
0

Actions

Likes
1
Downloads
0
Comments
0

0 Embeds 0

No embeds

Accessibility

Categories

Upload Details

Uploaded via as Adobe PDF

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

    Claw© "RTM" System Claw© "RTM" System Presentation Transcript

    • SERTECPET® ENERGETIC INTEGRATED SOLUTIONS
    • REAL TIME MONITORING SYSTEM Claw®-RTM
    • The Claw®-RTM system is an equipment of monitoring tools that permits to obtain reliable and precise reservoir pressure and temperature data in real time optimizing data, time, the well testing and the production with Jet g p Claw® pump. INNOVACIÓN Y TECNOLOGÍA
    • DESCRIPTION SPECIFICATION CONDUCTOR 22 AWG TEC (TUBING OD 0.25’’ 0 25’’ ENCAPSULATED CABLE) TEMPERATURE RANGE 302ºF (150ºC) Thickness of the isolation 0.0100’’ External cover Stainless Steel JET CLAW® SMART PUMP SMART JET CLAW® PUMP The Jet Smart Pump is used enough to carry SERTECPET® Shut Down Valve out the pressure well test and production. The Smart Jet Pump incorporates Bottom SERTECPET® DATA LOGGER valve closing. SENSOR CLAW® SENSOR SPECIFICATIONS* TRANSDUCER TYPE................... QUARTZ PRESSURE RANGES................... 10,000 psi (69 MPa) TEMPERATURE RANGES............ 302 °F (150 °C) SERTECPET ® PACKER PRESSURE ACCURACY................ ± 3.2 psi PRESSURE RESOLUTION............ ± 0.01 psi TEMPERATURE ACCURACY........ ± 0.36 °F / ± 0.20 °C TEMPERATURE RESOLUTION..... ±0.002 °F / ±0.001 °C
    • MAIN ELEMENTS OF CLAW® SYSTEM- RTM SENSOR OF QUARTZ OF HIGH PRECISION FOR RESERVOIR TEMPERATURE AND PRESSURE CARRIER JOINT TUBING ENCAPSULATED CABLE JET CLAW® SMART PUMP with SHUT DOWN VALVE ith CONNECTION TOOLS DATA LOGGER
    • SENSOR CLAW® TECHNICAL SPECIFICATIONS Transducer type........................................................... Cuarzo Pressure ranges........................................10.000 psi ( g p (69 Mpa) p ) Temperature ranges...........................................302ºf (150ºc) Pressure accuracy...............................................3.2psi Pressure resolution............................................0.01psi Temperature accuracy....................................± 0.18ºf/± 0.10ºc Temperature resolution............................± 0 002ºf/± 0 001ºc 0.002 f/± 0.001 c Fastest sample rate.....................................1 seg a 18 h. Tool diameter/length.....................1.0’’(2.54cm)/28.78’’(73.1cm) housing material.........................................................718 Inconel
    • SENSOR CLAW®
    • CARRIER JOINT Manufactured under stringent industry quality standards and can be adapted to any BHA design. Joint Carrier permanently as part of BHA. The Th sensor i i t ll d outside of th carrier f is installed t id f the i for sampling the reservoir and temperature pressure, the flowing bottom hole pressures and pressure pump intake through a communication port inside the pipe.
    • CARRIER JOINT The internal diameter of carrier fullfils industry standars and it’s free of y obstructions letting by pass of flow, and other tools, that are necessary for testing and working with the well.
    • CARRIER JOINT
    • SENSOR ASSEMBLY IN THE CARRIER JOINT The sensor assembly of the carrier joint Claw® has been tested in our hydraulic pumping well t t b f i ll test before it is transported to location.
    • THE SMART JET CLAW® PUMP Is used in those wells of oil production in a continuous way and in those well testing operations. Its h d I shut down valve optimizes the B ild up test. l i i h Build It eliminates the effect of the wellbore storage in the initial periods of build b ild up t t test. Applicable to exploration and production wells. wells Because of its metallurgy is used for the recovery of acids and solvents solvents. Ideal for cleaning sanded wells.
    • CABLE TEC (TUBING ENCAPSULATED CABLE) DESCRIPTION SPECIFICATION CONDUCTOR 22 AWG OD 0.25’’ TEMPERATURE RANGE 302 F (150 C) 302ºF (150ºC) Thickness of the isolation 0.0100’’ External cover Stainless Steel
    • TEC CABLE PROTECTOR TEC OD ¼ TEC OD ¼" Cable Protector  Cable Protector for mid Joint and  joint coupling
    • SURFACE CONNECTION TOOLS DESCRIPTION SPECIFICATION CONNECTOR SWAGELOCK ¼’’x ¾’’ NPT 3000 PSI
    • SERTECPET® DATA LOGGER The SERTECPET® DATALOGGER is a high performance Remote Terminal Unit (RTU)designed to interface with the Sensor Claw® of pressure and p temperature sensing products. It is capable of acquiring data from virtually any third party device that supports an analog, digital or Modbus pp g, g connection (hard wired or wireless). • Allows visualizing in the screen parameters, such as: o Reservoir Pressure, down hole flowing pressure o Intake Pressure o Reservoir Temperature
    • SERTECPET® DATA LOGGER GIC (gauge interface controller)
    • GENERAL CONFIGURATION OF THE CLAW®-RTM SYSTEM Autonomous WELL– JET CLAW” PUMP system • Bottom sensor SERTECPET® DATALOGGER RTU GIC • Analogous entry SCADA • Sensor • Analogous data outset • Left Modbus SensorCable Analogous signal Digital signal MODBUS Signal
    • COMMUNICATION SYSTEM The remote communication system let us establish real time communication from any place to the network in order to monitoring the pressure and well operation.
    • RESERVOIR PRESSURE AND TEMPERATURE REAL TIME MONITORING
    • RESERVOIR PRESSURE AND TEMPERATURE REAL TIME MONITORING
    • RESERVOIR PRESSURE AND TEMPERATURE REAL TIME MONITORING
    • RESERVOIR PRESSURE AND TEMPERATURE REAL TIME MONITORING
    • RESERVOIR PRESSURE AND TEMPERATURE REAL TIME MONITORING
    • ADVANTAGES OF REAL TIME MONITORING WELL TESTING WITH JET CLAW® PUMP It optimizes time and resources for taking well data. p g Real time verification of the build up well test. It could be registered different testing pressure like Build Up, flowing tests, injectivity, etc. injectivity etc Registers precise data of pressure and bottom temperature for the reservoir analysis. Continuous monitoring of Jet Claw® Pump performance. f l f Optimizing production with non-stop operation. Easy install and operation operation. Instant registration of data for taking decisions with non – stop production.
    • ADVANTAGES OF REAL TIME MONITORING WELL TESTING WITH JET CLAW® PUMP The Jet Claw® Pump is hydraulically set and reversed, without taking out the completion. p Due to its configuration, the Jet Pump does not overheat and its repair can be done in 15 minutes. It can produce several pressure differentials according t th d l diff ti l di to the characteristics of the reservoir, changing only the injection pressure. The metallurgy of the pump depends on the requirement of the client, it can work in corrosive and/or abbrasive environments. Low operative costs. Real time immediate recovery of the well capacity, IP capacity IP.