  • Welcome to the all new Model ELC from Controlled Power Co. We’ll take a look at the prominent features which set this new addition to the CPC Inverter family, apart from anything else in its class in the industry
  • Historically, Life Safety has been “Design by Disaster”. It is the designers obligation to provide proper notification systems along with reliable, well lit and marked paths of egress.
  • First lets recap what we have to work with here… The key features of this offering, for the sake of this discussion, are ELN and ELE Series use what is quite often referred to as a “constant voltage transformer” based topology. The ELU Series offers a true on line, double conversion topology. Both of which provide outstanding power quality solution characteristics!
  • Although a new topic in lighting circles, Power Quality is a well known culprit in electronic component failures. As electronics are continuing to expand in the lighting market, this issue becomes a more prominent topic in the design and service aspects of project designs The CPC family of inverters deliver the tightest voltage regulation in the industry (+/-1.5 to 3%), noise attenuation/filtering and provide a computer grade sinewave to all output loads. Thereby assuring the designer/engineer of optimum power for critical lighting performance!
  • But don’t just take our word for it! Here’s an industry comparison showing that the CPC family of inverters have the widest input range on the market and yet they deliver the tightest load voltage regulation of anybody. Then just to make it even better, nobody outdoes us on output sinewave harmonic distortion (vTHD) or as far as cleaning up random electrical noise and transients! The competition can only match us on a few individual points. But from top to bottom, we’re the best!
  • First lets start with the basic features of this new Inverter… The key features of this offering, The ELC offers a true on line, double conversion topology (Note that kVA = KW in terms of rating and supporting of all types of lighting loads). This then allows it to deliver outstanding power quality solution characteristics! Plus as you’ll see, offering a lot of configurability through both controls and communications, as well as options and features.
  • Most of you will recognize the traditional single line diagram of how the ELC and most other Double Conversion based inverters operate. The two primary keys to remember with the ELC are that 1) it is capable of supporting all types of lighting loads at full rated power, without the need for additional filters or controls. 2) It delivers regulated, spike-free sinewave to the critical load, thereby extending the life of electronic lighting loads like LED and “Energy Efficient” Fluorescent lighting.
  • This Status and Control panel for the ELC offers a similar appearance to the standard panel on the ELU Series with indicators for incoming power presence, whether or not the inverter is in bypass mode, how heavily the ELC is currently being loaded, % Battery Time remaining, Check Battery indicator, and an Audible Alarm/Silence switch, as well as basic On/Off Soft Keys. But that’s just the beginning…
  • While the ELC can certainly interface with typical remote annunciators, autodialers, fax modems and so on…it also includes a direct connection to the NetMinder option, mounted within the ELC cabinet. The NETMINDER allows the ELC to communicate directly with more contemporary Facility Management Systems like PowerLogic, Fanuc, Windows, etc.
  • Dimensionally, the ELC Series is a true front access only cabinet design, where input/output conduits are routed via the unit’s top rather than the sides (although an installer could land his conduits from the side if they so desired). Comparatively as you can see, the others in the industry are close in size but many require additional side conduit access space…thereby making their net space requirement even bigger!
  • Then last but not least, in terms of Power Quality and overall performance, the ELC remains on par with its bigger brothers in the CPC product family of Inverters, which by the way, also outclass the competition in terms of delivering spike-free, regulated power to critical emergency loads which now include electronics. Finally then just to qualify what we’re saying here in the last column, we’re defining Isolated output as a true, computer grade, sinewave that’s been recreated by either the inclusion of an Isolation transformer or true on-line, double conversion process. So in conclusion, as we’ve already discussed, this means superior more predictable lighting along the path of egress, for a significantly longer design life of the building.

Controlled Power Company Overview 2010 Controlled Power Company Overview 2010 Presentation Transcript

  • Controlled Power Company Product Overview Factory Representative: Integrated Power Systems
  • Ultra-K Energy Efficient, Shielded, K-Rated, Isolation Transformer Power Purifier Constant Voltage Power Conditioning System Power Processor 3% Line Voltage Regulator (Tap Switcher) LT, MD, HV Ø1 Ferro-resonant UPS UltraUPS Ø1 Double-Conversion UPS EL Series Centralized Emergency Lighting Inverters PDU, Rectifiers Other Product Lines CPC SOLUTION-ORIENTED PRODUCTS
  • Ultra-K Shielded Isolation Transformers NEMA TP-1
  • Ultra-K Shielded Isolation Transformers
    • Where you might use them?
    • Anyplace that has electronic loads like…
    • Electronic ballast lighting
    • Computer / Communications systems
    • Variable Frequency Drives
    • Other mission critical electronic loads
  • WHAT ULTRA-K ISOLATION PROVIDES
    • Excellent load voltage regulation, during load step or high harmonic conditions.
    • Significant Common Mode noise reduction (like static on audio systems, distortion on video screens or otherwise inexplicable error messages in IT systems). In fact we offer you a choice of 1 million : 1 (2 shield), or 10 million : 1 (3 shield) in CMN attenuation.
    • Superior harmonic handling capability (harmonics cause systems to run hot, fool generators and building logic systems, plus numerous other physical and IT system issues).
    • Creates new Neutral and provides new source when electrical grounding is a problem.
  • K-FACTOR
    • As a result of high neutral currents on harmonic rich circuits:
    • E ddy currents (the circulating current at the surface of a wire) prevents total current penetration of cylindrical wire.
    • A s the frequency increases, the penetration decreases, using less cross sectional area of the wire. The wire heats up as a result.
    • A pplied to a transformer, the K-factor expresses the ability of the transformer to handle harmonic currents without overheating .
    Conductor Cross-Section Skin Effect of High Frequency Currents = Overheating
  • Why buy an Ultra-K?
    • Noise Reduction & Line Conditioning.
    • K-Rated for Harmonic Handling Capability Provides power conditioning, K-rating, NEMA TP-1 and Energy Star ® compliance.
    • Superior Harmonic Handling & Load Changes without overheating or over-sizing.
    • Highest Grade of Construction Materials.
    • High Efficiency – (fka EPA Energy Star ® ) & NEMA TP1 listed.
    • Low Heat Rise – 115 o C.
    • Low Output Impedance.
  • WHAT IF THE UTILITY VOLTAGE IS SAGGING OR SURGING?
    • Isolation and good grounding alone, may not be enough…
    • Controlled Power offers a variety of products which both isolate and regulate the voltage even when utility power fluctuates beyond acceptable limits.
    • Single Phase (Series 800 Power Purifier) from 250 VA up to 25 kVA
    • Three Phase (Series 700 Power Processor) from 15 kVA to 500 kVA
  • POWER PURIFIER A Power Conditioner That Solves 99.5% of All Power Problems! - SERIES 800 PI - INDUSTRIAL APPLICATIONS
    • Output distribution from 250 va up to 25 Kva.
    • Rugged cabinet with convection cooling.
    • Hardwired in / out
    • Power factor near unity
    • NEMA2 & NEMA3R Enclosures
    • Can Parallel For Higher kVA’s
    • Output distribution from 250 va up to 15 Kva.
    • Attractive enclosure with cooling fans.
    • Input line cord included on units up to 3.5 Kva.
    • Rated at a .7 power factor
    • NEMA 1 Enclosure
    - SERIES 800 A - COMMERCIAL APPLICATIONS
  • WHERE YOU MIGHT USE THE SERIES 800?
    • Computerized Industrial Control Systems
    • Process-Numerical Control
    • Audio-Visual Security Systems
    • Data Acquisition Systems (SCADA)
    • Security and/or Fire Alarm Systems
    • Programmable Logic Controllers (PLC’S)
    • Automated Systems / Robotics
    • Test and Measurement Instrumentation
    • All Sensitive Electronic Equipment
    • Systems where you need voltage regulation and a clean signal but don’t necessarily need batteries.
  • WHAT THE SERIES 800 PROVIDES
    • Same type of performance as 2 shield Ultra K Transformer, PLUS…
    • Load Voltage Regulation (+/- 2 to 5%) when utility sags as much as 45% or surges as much as 15% from nominal
    • Optional Plug n Play or Hardwired connectivity
    • Up to 1 cycle of ridethrough at full load
  • WHAT THE SERIES 800 PROVIDES
    • Electrical Isolation (126 db CMN)
    • New Neutral and Source of Power
    • K30 Harmonic Handling performance
    • Power Factor Correction
    • Load Voltage Regulation (+/- 2 to 5%)
    • Ridethrough (short duration outage protection)
    • (OPTIONAL medical grade listing)
  • WHAT IF THE UTILITY VOLTAGE IS SAGGING OR SURGING?
    • Isolation and good Grounding alone, may not be enough, specifically when utility power fluctuates beyond high or low voltage acceptable limits.
    • Series 800 Power Purifier provides:
    • Voltage correction via Variable Range Regulation
    Load Level Input Voltage from Nominal Output Voltage Regulation 25% +10 / -45% (i.e. nominal 120v swings 132v to 66v) +/- 3% (aka 120v stays within 123v to 116v) 50% +10 / -40% +/- 3% 75% +10 / -35% +/- 3% 100% +10 / -20% +/- 2%
  • POWER PURIFIER PERFORMANCE Power Output 1 phase, 100% duty, kVA & kW for linear & non-linear loads Line Voltage Regulation @100% load, 2%V out for +10% to -20% V in Immunity to Distortion @40% THD V in , 5% THD V out Load Regulation 2.5% for 0% to 100% load Voltage Recovery 2 cycles to 95% 3 cycles to 100% K-Factor K30 rated Power Factor Correction Input pf 0.95 typical Harmonic Attenuation -23dB for load reflected harmonics Galvanic Isolation NEC 250 5d .001pf Surge Protection 3000:1 ANSI/IEEE C62.42-45 CMN Attenuation 140dB TMN Attenuation 120dB Ride Through 1 cycle (16.6ms) Reliability 200,000 hr. MTBF Efficiency 92% Typical
  • Why buy a Power Purifier?
    • Noise Reduction & Line Conditioning = More Reliable Operation of Mission Critical Systems.
    • K-Rated for Harmonic Handling Capability Provides power conditioning, K-rating = Power Circuits Operate More Efficiently .
    • Superior Harmonic Handling without overheating or over-sizing = Better Size Matching to Load Requirements.
    • Highest Grade of Construction Materials = More Efficient Operation.
    • Voltage Regulation = Better System Performance .
    • Low Heat Rise Design = Cooler Operation.
    • Up to 1 Cycle of Outage Ridethrough without using batteries = Lower Protection Cost.
    • 15 To 500 kVA (Three Phase)
    • +10% to -20% Input Voltage Range w/ Output Regulation of +/-3%
    • ½ Cycle Response
    • Input Circuit Breaker
    • Triple-Shield 140dB Attenuation
    • Low Output Impedance
    The “Power Processor” Series 700 Power Line Conditioner
    • Brownouts or Over-Voltage
    • Fluctuating Voltage
    • Noise, Transients, or Impulses
    Power Line Problems Solved by The Power Processor
  • POWER PROCESSOR PERFORMANCE
    • +10%, -40% Input Voltage Range Capability
    • <2 – 3% Load Voltage Regulation
    • Small Physical Size vs UPS
    • Highly Efficient (Typically ~ 97%)
    • Harmonic Immune Control Circuitry
    • < 1 Cycle Correction For Over/Under Input Voltages
  • WHAT THE SERIES 700 PROVIDES
    • Same type of performance as 3 shield Ultra K Transformer, PLUS…
    • Load Voltage Regulation (+/- 2 to 3%) when utility sags as much as 20% or surges as much as 15% from nominal (extended input range available as option)
    • Optional Circuit Breaker or Hardwired connectivity
    • Less than 1 cycle response time
  • WHERE YOU MIGHT USE THE SERIES 700 Power Processor?
    • Computerized Industrial Control Systems (like VFD’s)
    • Automated Systems / Robotics
    • Test and Measurement Instrumentation
    • Large Printing Press Systems
    • Water Treatment & Pumping Stations
    • Conveyor Control Systems
    • All Sensitive Electronic Equipment
    • Systems where you need voltage regulation and a clean signal but don’t necessarily need batteries.
    • Bypass Circuits for UPS Systems
  • Why buy a Power Processor?
    • Noise Reduction & Line Conditioning = More Reliable Operation of Mission Critical Systems.
    • K-Rated for Harmonic Handling Capability Provides power conditioning, K-rating = Power Circuits Operate More Efficiently .
    • Superior Harmonic Handling without overheating or over-sizing = Better Size Matching to Load Requirements.
    • Highest Grade of Construction Materials = More Efficient Operation.
    • Voltage Regulation = Better System Performance .
    • Low Heat Rise Design = Cooler Operation.
    • Smaller Size than Comparable UPS = Lower Protection System Cost.
  • The UPS Family of Products
  • The Size of Our Family
    • LT - 700VA to 2.1KVA
    • LTR - 700VA to 2.1KVA
    • LTN – 700VA to 2.1KVA
    • Vin x Vout
    • 120 120 120/208 120/240
    • 208 120 120/208 120/240
    • 240 120 120/208 120/240
  • The Size of Our Family
    • MD - 3.1KVA to 7.5KVA
    • Vin x Vout
    • 120/208 120/240
    • 120/208 120/240
    • 240 120/208 120/240
    • HV - 7.5KVA to 25KVA
    • Vin x Vout
    • 120/208 120/240
    • 120/208 120/240
    • 240 120/208 120/240
  • 3 & 5 kVA Single Phase
    • On-Line
    • Double Conversion with Static Bypass
    • Modular
    • Stack or Rack
    • Versatile Distribution System
    UltraUPS Computing Telecommunications Industrial Automation Instrumentation Testing Emergency Lighting Medical
  • WHAT YOU GET FROM THE CPC UPS
    • Isolation and Regulation all the time!
    • N+1 Battery Redundancy
    • Bypass Switch Selections
    • ± 1.5% Voltage Regulation
    • +15% to -45% Input Voltage Range
    • Automatic Battery Extension Cutoff
    • Extended Battery Life via Enhanced Charging
    • 0.99 Input Power Factor
    • Input Current THD < 5%
    • Rapid Recharge
    • Connection Configurability
  • CONTROLLED POWER COMPANY 1 Emergency Lighting Inverters CONTROLLED POWER COMPANY Emergency Lighting Inverters
  • 3 Critical Links for Life Safety
    • Notification that an emergency condition exist
    • Visibility created and maintained by emergency lighting systems
    • Direction established to safe exit areas
    • The reliability of a life safety design is only as strong
    • as the weakest link.
    Notification Direction Visibility
  • Design Criteria-Occupancy Permit
    • UL 924 Emergency Lighting Equipment
    • NEC Article 700
    • NFPA 101 Illumination Requirements
    • Local Codes
    • Mandatory, Periodic Testing
    Minimum Life Safety Requirements Code Compliant Solutions
    • Generators, Diesel or Natural Gas
      • UL 924 Auxiliary Power Supplies
    • Individual Battery Packs
    • Emergency Ballasts
    • Centralized Inverters
  • Engineered Life Safety Individual Wall Packs or Centralized Inverter? Wall Packs 4.2kW Lighting Inverter Self Testing Self Diagnostics Annual NFPA 101, Results Logged Email NFPA 101 Results Email “Service Required” Monthly NFPA 101, Results Logged
  • Engineered Life Safety Emergency Ballasts or Centralized Inverter? 1400 Lumen Fluorescent Battery Pack w/SD 4.2kW Lighting Inverter Self Testing Self Diagnostics Annual NFPA 101, Results Logged Email NFPA 101 Results Email “Service Required” Monthly NFPA 101, Results Logged
  • Compliance Expense *Expense based on initial investment, installation and qualified, third party testing per NFPA 101
  • 3 Year Compliance Expense Lithonia Emergency Ballast & Wall Pack pricing from Grainger
    • Manual or Automatic Battery testing compliant
    • with NFPA 101& 111
    • Standard Input and Output Circuit Breakers
    • Option for Multiple/Dual Output Voltages
    • Maintenance Bypass Switches (optional on ELN)
    • Self Contained 90min Battery Backup
    • Standard Front Access Only Enclosures
    • Communications Interfacing
    • 2 year full warranty on Inverter & 15 year prorated warranty on battery
    eLITE & ULTRALITE Series Features STANDARD FEATURES CENTRAL LIGHTING INVERTERS
  • Current CPC Inverter Products
    • Sizes range from 550W to 18 KW
    • ELN & ELE use Ferro Topology
    • ELU uses Double Conversion
    ELN ELU and ELE Series PQ Tips
    • Key Advantages Include:
    • HID/LED Compatible,
    • Uninterrupted, Regulated,
    • Conditioned, Sinewave Output
    • Multiple Output CB’s
    • Input/Output Configurability
    • Communications capabilities
    • Battery Testing
    • Multiple Output
    • voltages
  • Current CPC Inverter Products
    • Sizes range from 550W to 18 KW
    • ELN & ELE use Ferro Topology
    • ELU uses Double Conversion
    ELN ELU and ELE Series PQ Summary
    • Key Advantages Include:
    • HID/LED Compatible,
    • Uninterrupted, Regulated,
    • Conditioned, Sinewave Output
    • <+/- 3% load voltage regulation
    • Electronic Noise/Spike reduction
    • Computer grade sinewave output
    • Assures proper voltage
    • Translating then to optimum
    • Light output at fixture
    • Provides longer life for expensive
    • ballasts and power supplies
  • * NOTE: ELN & ELE Series load regulation is load dependant using Fuzzy Ranging technology Inverter Performance Comparison Brand Model Input Voltage Range Output Voltage Range Output Voltage THD Noise Isolation Crucial Power Products EconoSine +/-10% +/-4% 10% max. Optional / External   Waverider +15/-20% +/-3% <5% THD -120db             DualLite LSN +10/-15% +/-5% <5% THD none stated   Synchron +/-10% +10/-5% <5% THD none             Myers e ie +10/-15% +/-2 to 12.5% <3% THD none stated   CM +10/-15% +/-3% @<25% load step <3% THD none stated             DSPM/Powerclone DE +10/-15% +/-3 to 8% < 8% none stated   Cobramini +10/-15% +/-3 to 8% < 8% none stated             On Line Power Powerwave +10/-15% +/-3-5% 5% THD Isolation included but not defined             CPC ELU +12/-30% <+/-1.5% <3% THD 120db   ELN* +10/-40% <+/-3% <3% THD 120db   ELE* +10/-15% <+/-3% <3% THD 120db
  • Model ELC Inverter
    • Sizes 600W, 1KW, 1.5KW & 2 KW
    • ELC uses Double Conversion Topology
    ELC Main Features
    • Key Advantages Include:
    • HID/LED Compatible,
    • Uninterrupted, Regulated,
    • Conditioned, Sinewave Output
    • Up to 12 Output CB’s Available
    • Integral Inverter Bypass Switch
    • Input/Output Configurability
    • Communications Capabilities
    • Automatic Battery Testing
    • Field Programmable Off Bus
    • Control Capabilities
    • Smallest Footprint in the Industry!
    600W 90 Min. 1 thru 2kW 90 Min. 2 kW 2-4 Hours.
  • Model ELC Inverter
    • Automatic Static Switch
    ELC uses Double Conversion Topology Key Advantages Include: HID/LED Compatible, Uninterrupted, Regulated, Conditioned, Sinewave Output! AC DC Battery DC AC Fault Clearing path of power Normal path of power
  • Model ELC Inverter
    • Communications Capabilities
    • System Status and Alarm Panel:
    • Traditional Contact Closure Signals
    • for Remote Annunciation
    • LED Indicators for Incoming Voltage
    • Conditions
    • LED Load Indicators
    • LED Mode of Operation Indicators
    • LED Battery Status Indicators
    • Check Battery Indicator
    • On/Off Soft Keys
    • Alarm Silence Switch
  • Model ELC Inverter
    • Remote Communications Capabilities
    • Available Options Include:
    • Traditional Contact Closure Signals
    • for Remote Annunciation
    • Remote Annunciator
    • Auto Dialer
    • Fax Modem
    • Netminder Ethernet / SNMP / TCP/IP / MODBUS TCP
    • or RS485
    Facilities Mgmt System Factory Installed within ELC Cabinet
  • Model ELC Inverter
    • Smallest Footprint In Its Class!
    • Dimension Comparison vs:
    • Myers CM Series
    • Dual-Lite DLS Series
    • Crucial Power EconoSine Series
    • DSPM Cobra Mini Series
    22”W x 11.75”D net 26”W x 10”D unit 22”W x 10”D thru 525W 36”W x 19”D net 30”W x 19”D net Front Access Only Plus includes Side 32”W x 12”D 750W-2.1KW Includes Rear & Side Includes Rear & Side Requirement Access Requirement Clearance Clearance
  • Inverter Performance Comparison Brand Model Input Voltage Range Output Voltage Range Output Voltage THD Isolated Output Crucial Power Products EconoSine +/-10% +/-4% 10% max. Opt.(External Xfrmr)   Waverider +15/-20% +/-3% <5% THD yes             Dual-Lite LSN +10/-15% +/-5% <5% THD Opt.(External Xfrmr)   Synchron +/-10% +10/-5% <5% THD No             Myers E & IE +10/-15% +/-2 to 12.5% <3% THD Optional – Input/Output Voltage Dependant   CM +10/-15% +/-3% @<25% load step <3% THD None Stated             DSPM / Powerclone DE +10/-15% +/-3 to 8% < 8% Yes 4.7KW and up   Cobra mini +10/-15% +/-3 to 8% < 8% Opt. Internal Xfrmr.             On Line Power Powerwave +10/-15% +/-3-5% 5% THD Yes             CPC ELC +12/-30% typ <+/-2% <3% THD Yes   ELU +12/-30% typ <+/-1.5% <3% THD Yes   ELN +10/-40% typ <+/-3% <3% THD Yes   ELE +10/-15% <+/-3% <3% THD Yes
  • Question?