EASY                  ENVIRONM                        COSTDURABLE   MAINTAINE                 ENT                      EFF...
SEA WATER COOLING TOWERS               AGENDA•   INTRODUCTION•   INFRASTRUCTURE REQUIRMENT•   TYPES OF SEAWATER COOLING•  ...
SEA WATER COOLING TOWERS            INTRODUCTION•COOLING TOWERS ARE A VERY IMPORTANT PART OF MANYPLANTS. NOT ONLY DISTRICT...
SEA WATER COOLING TOWERS             WHY DO WE USE SEAWATER             COOLING TOWERS?1. DURABLE2. EASY MAINTAINED3. ENER...
SEA WATER COOLING TOWERS    • WHY DO INDUSTRIES NEED SEA      WATER COOLING SYSTEM ? .•   HEAT REJECTION FROM INDUSTRIES.•...
SEA WATER COOLING TOWERS             INFRASTRUCTURE REQUIRREMENT1. SEA WATER INTAKE  STRUCTURE.2. PUMPING STATION.3. PIPIN...
SEA WATER COOLING TOWERS    • TYPES OF SEA WATER COOLING•   ONCE THROUGH.•    EVAPORATIVE COOLING.•   RE-CIRCULATING COOLI...
SEA WATER COOLING TOWERS                TYPES OF COOLING TOWERSNATURAL DRAFT                             MECHANICAL DRAFT ...
SEA WATER COOLING TOWERS               ADVANTAGES FOR CIRCULAR TYPE1. NATURAL DRAUGHT DURING WINTER  OPERATION (APPROX. < ...
SEA WATER COOLING TOWERS               ADVANTAGES FOR CIRCULAR TYPE5. NO RECIRCULATION, NO INTERFERENCE6. PLUME FORMING FA...
SEA WATER COOLING TOWERSADVANTAGES FOR CIRCULAR TYPE                     FIGURE -1                     LESS SPACE REQUIREM...
SEA WATER COOLING TOWERS                ADVANTAGES11. LOWER POWER CONSUMPTION.12. LESS MAINTENANCE.13. LONGER LIFE. (MECHA...
SEA WATER COOLING TOWERS               DISADVANTAGES1. THERE IS NO FINANCIAL INCENTIVE FOR  DEVELOPERS OR DISTRICT COOLING...
SEA WATER COOLING TOWERS                DISADVANTAGES6. TO BE USED ONLY FOR SHOPPING CENTERS  AND LOWRISE BUILDINGS.7. GEO...
SEA WATER COOLING TOWERS  CASE STUDYJUBAIL INDUSTRIAL CITY    SAUDI ARABIA
SEA WATER COOLING TOWERS    SWC SYSTEM COMPONENTS AT JUBAIL 1•   SEA WATER INTAKE ( INTAKE CHANNEL AND PUMP    STATION )• ...
SEA WATER COOLING TOWERS                      ONCE THROUGH CONCEPTSea Water         + 10 o CReturn ( Hot )                ...
SEA WATER COOLING TOWERS
SEA WATER COOLING TOWERS     INTAKE CHANNEL
INTAKE CHANNEL                DREDGED CHANNEL                                        ARABIAN                              ...
SWC PUMP STATION I & II SWC 1                       SWC 2A-A
SEA WATER COOLING TOWERSPUMP STATION
SWC PUMP STATION
INVERTED SIPHONSStart of                      End ofCanal 2                       Canal 1               Siphons           ...
OFF-TAKE STRUCTURE                                      SUPPLY            RETURN                                      STRU...
OUTFALL
CAPACITY OF THE PUMP STATION                      Ultimate Pump Stations              Summer                             C...
Canal ( 1, 2 ,3 and 4 )          Siphon 3                           Canal 3                                           Pump...
CAPACITY OF THE CANAL SYSTEM• ORIGINAL DESIGN CAPACITY IS 816,000 M3/HR USING THE  ORIGINAL CONCEPT OF ONE S COMPARTMENT ,...
SEA WATER COOLING TOWERS    CONCLUSIONSEA WATER COOLING IS THE ONE FOR OUR INDUSTRIES
SEA WATER COOLING TOWERS
SEA WATER COOLING TOWERS
Upcoming SlideShare
Loading in...5
×

Hisham hajaj, stanley consultants

1,408

Published on

Published in: Technology, Business
0 Comments
1 Like
Statistics
Notes
  • Be the first to comment

No Downloads
Views
Total Views
1,408
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
80
Comments
0
Likes
1
Embeds 0
No embeds

No notes for slide

Transcript of "Hisham hajaj, stanley consultants"

  1. 1. EASY ENVIRONM COSTDURABLE MAINTAINE ENT EFFECTIVE D FRIENDLY
  2. 2. SEA WATER COOLING TOWERS AGENDA• INTRODUCTION• INFRASTRUCTURE REQUIRMENT• TYPES OF SEAWATER COOLING• TYPES OF COOLING TOWERS• ADVANTEGES OF CIRCULAR COOLING TOWER• DISADVANTEGES OF CIRCULAR COOLING TOWER• THE BIG STORY – CASE STUDY
  3. 3. SEA WATER COOLING TOWERS INTRODUCTION•COOLING TOWERS ARE A VERY IMPORTANT PART OF MANYPLANTS. NOT ONLY DISTRICT COOLING PLANTS BUT ALSO MOST OFINDUSTRIAL PLANTS.
  4. 4. SEA WATER COOLING TOWERS WHY DO WE USE SEAWATER COOLING TOWERS?1. DURABLE2. EASY MAINTAINED3. ENERGY CONSERVATION4. ENVIRONMENT FRIENDLY5. COST EFFECTIVE ALTERNATIVE SOLUTION DUE TO THE ELEVATED COST OF POTABLE WATER.6. SCARCITY OF WATER RESOURCES.
  5. 5. SEA WATER COOLING TOWERS • WHY DO INDUSTRIES NEED SEA WATER COOLING SYSTEM ? .• HEAT REJECTION FROM INDUSTRIES.• COOLING MEDIA IS REQUIRED TO ABSORB HEAT• THE SYSTEM PROVIDE SEA WATER TO BE THE COOLING MEDIA TO ABSORB HEAT FROM INDUSTRIES AND DISSIPATE HEAT INTO THE SEA.
  6. 6. SEA WATER COOLING TOWERS INFRASTRUCTURE REQUIRREMENT1. SEA WATER INTAKE STRUCTURE.2. PUMPING STATION.3. PIPING OR CANAL.4. INDUSTRIES OFF-TAKE STRUCTURES.5. OUTFALL STRUCTURE.
  7. 7. SEA WATER COOLING TOWERS • TYPES OF SEA WATER COOLING• ONCE THROUGH.• EVAPORATIVE COOLING.• RE-CIRCULATING COOLING TOWERS
  8. 8. SEA WATER COOLING TOWERS TYPES OF COOLING TOWERSNATURAL DRAFT MECHANICAL DRAFT FAN ASSISTED NATURAL DRAFT
  9. 9. SEA WATER COOLING TOWERS ADVANTAGES FOR CIRCULAR TYPE1. NATURAL DRAUGHT DURING WINTER OPERATION (APPROX. < 20 DEGREE C)2. NO RESTRICTIONS FOR TOWER SITTING WITHIN THE SITE3. UNBIASED TO WIND DIRECTION THERFOR, THERE IS NO ISSUE WITH THE TOWER ORINATION.4. SHORT DISTANCE TO PROCESS PLANT ( LESS PIPING)
  10. 10. SEA WATER COOLING TOWERS ADVANTAGES FOR CIRCULAR TYPE5. NO RECIRCULATION, NO INTERFERENCE6. PLUME FORMING FAR AWAY FROM THE GROUND LEVEL7. EASY CONTROL SYSTEM8. LOW EMISSION IN CASE OF SALT WATER9. LOWER TOTAL INVESTMENT COST (EARTHWORKS + COOLING TOWER + PIPING)10. LESS SPACE REQUIREMENT (SEE FIG. -1)
  11. 11. SEA WATER COOLING TOWERSADVANTAGES FOR CIRCULAR TYPE FIGURE -1 LESS SPACE REQUIREMENT
  12. 12. SEA WATER COOLING TOWERS ADVANTAGES11. LOWER POWER CONSUMPTION.12. LESS MAINTENANCE.13. LONGER LIFE. (MECHANICAL SECTION AWAY FROM PLUME WITH SALT CONTENT IN DRIFT).14. PEOPLE LIVING IN BUILDINGS IN THE SURROUNDING AREA WILL NOT LOOK DOWN TO SEE HUNDREDS OF REVOLVING FANS WHICH IS THE CASE IN CELL TYPE. CIRCULAR DESIGN GENERALLY REQUIRES MAXIMUM 1-4 TOWERS WHERE THE FANS ARE CONCEALED FROM VIEW.
  13. 13. SEA WATER COOLING TOWERS DISADVANTAGES1. THERE IS NO FINANCIAL INCENTIVE FOR DEVELOPERS OR DISTRICT COOLING PROVIDERS.2. SPECIAL CHILLERS AND TUBING.3. HIGH INTIAL INFRASTRUCTURE COST.4. TEMPERATURE VARIATIONS IMPACT MARINE LIFE5. LOCAL AUTHORITIES REGULATION
  14. 14. SEA WATER COOLING TOWERS DISADVANTAGES6. TO BE USED ONLY FOR SHOPPING CENTERS AND LOWRISE BUILDINGS.7. GEOGRAPHIC LOCATION LIMITATIONS.8. MAINTAINING THE DELIVERY SYSTEM.9. DISCHARGE SEAWATER TEMPRATURE LIMITATION.
  15. 15. SEA WATER COOLING TOWERS CASE STUDYJUBAIL INDUSTRIAL CITY SAUDI ARABIA
  16. 16. SEA WATER COOLING TOWERS SWC SYSTEM COMPONENTS AT JUBAIL 1• SEA WATER INTAKE ( INTAKE CHANNEL AND PUMP STATION )• CANAL SYSTEM • 3 CANALS SEGMENTS WITH 3 COMPARTMENTS ( SUPPLY , SUPPLY / RETURN , RETURN )• INVERTED SIPHONS BETWEEN CANALS SEGMENTS• INDUSTRIES OFF-TAKE STRUCTURES AND LATERALS PIPES• OUTFALL STRUCTURE
  17. 17. SEA WATER COOLING TOWERS ONCE THROUGH CONCEPTSea Water + 10 o CReturn ( Hot ) HOT PROCESS WATER TYPICAL PLATE HEAT Q IN EXCHANGERQ SWCSUPPLY COLD PROCESS WATERSEA WATERSUPPLY ( COLD ) ALL WATER FORM SWC SYSTEM PASS THROUGH THE INDUSTRY HEAT EXCHANGER INDUSTRIES FENCE Q SWC SUPPLY = Q IN
  18. 18. SEA WATER COOLING TOWERS
  19. 19. SEA WATER COOLING TOWERS INTAKE CHANNEL
  20. 20. INTAKE CHANNEL DREDGED CHANNEL ARABIAN GULFLength : 2.5 KMWidth : 60 – 190 M (Dredged Channel)Depth : - 3.7m RCD
  21. 21. SWC PUMP STATION I & II SWC 1 SWC 2A-A
  22. 22. SEA WATER COOLING TOWERSPUMP STATION
  23. 23. SWC PUMP STATION
  24. 24. INVERTED SIPHONSStart of End ofCanal 2 Canal 1 Siphons Pipes
  25. 25. OFF-TAKE STRUCTURE SUPPLY RETURN STRUCTURE STRUCTURE ACCESS BRIDGEFLOW MEASUREMENTCHAMBER S S/R R SEAWATER TO LATERAL PIPELINE USER INDUSTRY
  26. 26. OUTFALL
  27. 27. CAPACITY OF THE PUMP STATION Ultimate Pump Stations Summer Capacity Operation ( Peak ) Total Pump Flow Max Flow Total Total Flow Pumps m3/s m3/s Pumps m3/sLarge / SmallPumps 18 / 10 13.5 /10.3 346 16 /8 298Total Flow( 1000 m3 / hr ) 28 1,245 24 ( 4 ) 1,074
  28. 28. Canal ( 1, 2 ,3 and 4 ) Siphon 3 Canal 3 Pump Station Siphon 2 Canal 1 Siphon 4Canal 2 Siphon 1 Outfall
  29. 29. CAPACITY OF THE CANAL SYSTEM• ORIGINAL DESIGN CAPACITY IS 816,000 M3/HR USING THE ORIGINAL CONCEPT OF ONE S COMPARTMENT , ONE R COMPARTMENT AND KEEP THE S/R AS STAND-BY• CONCEPT HAS BEEN MODIFIED TO USE S AND S/R COMPARTMENTS IN OPERATION AS SUPPLY CANALS DURING PEAK AND ONLY R COMPARTMENT USED FOR RETURN. THIS WILL DOUBLE THE SUPPLY CAPACITY. HOWEVER ,• THE CAPACITY OF THE RETURN CANAL CAN DELIVER 970,000 M3/ HR . SO OTHER MODIFICATION INTRODUCED.• PETROKEMYA BYPASS, THE CANAL DISCHARGE CAPACITY CAN BE INCREASED BY 190,000 M3 / HR (2 PIPES) INCREASING THE TOTAL CANALS DISCHARGE CAPACITY TO 1,160,000 M3 / HR .
  30. 30. SEA WATER COOLING TOWERS CONCLUSIONSEA WATER COOLING IS THE ONE FOR OUR INDUSTRIES
  31. 31. SEA WATER COOLING TOWERS
  32. 32. SEA WATER COOLING TOWERS