Your SlideShare is downloading. ×
PUMP PRODUCTS GUIDE

TORISHIMA PUMPMFG. CO., LTD
Innovative solutions coupled with
expertise in pumping technology
TORISHIMA is a leading pump manufacturer, founded in 191...
Energy Industry

Condensate pump for combined cycle power plant (MMTV)
Vaporizing pumps for LNG plant (SPV)
Barrel type su...
Water supply pumps for potable water distribution pumping station (CDM)
Long-distance potable water transmission pumps (CD...
Storm water drainage pumps for sewage treatment plant (SPV)
Drainage pumps for agriculture (SP)
Irrigation pumps (CDM)
Slu...
Regional Development
Urban Development

Pumps for air conditioning system for building facility (CAL)
Cooling water pumps ...
Chemical Industry

Process pumps for chemical plant (CPC)
Process pumps for DMT plant (CPC)
Cooling water pumps for petroc...
General Industry

Water supply pumps for machinery plant (CAL)
Treated water pumps for beverage plant (CAR)
Process pumps ...
CEBS
Pressing stainless end-suction volute pump

5

USgpm

20

80 100

End-Suction

End-Suction

End-Suction Pumps

300

8...
USgpm

100

500

1000

2000
250

Non-clogging end-suction volute pump
30

50

200
150

10

USgpm

100

1000

7000

500

10...
Double-Suction Pumps

Multi-Stage Pumps

Double-Suction
Axially split double-suction pump
The world’s most advanced high e...
MSH, MSH-T(twin-suction)
Horizontal axially split multistage volute pump
The axially split design offers ease of
maintenan...
Mixed-Flow Pumps

SPSX
Mixed-flow volute pump
Mainly used for water pumping and drainage for
agriculture. Simple back pull...
Submersible Pumps

S/M
Dry-type submersible motor pump
Small light-weight and easy to handle. Best suited
for discharging ...
Miscellaneous Pumps

TE/O,
TE/CO (Stainless steel)
Self priming pump
No need for priming. Offering outstanding self
primin...
Torishima’s

Torishima’s

Mechanical Seals

Service Solutions

Mechanical seals - the shaft seals used in rotating machine...
PUMP PRODUCTS GUIDE

TORISHIMA PUMPMFG. CO., LTD
Upcoming SlideShare
Loading in...5
×

Torishima Pump general catalogue, Venezuela, Central America, Caribbean

1,152

Published on

Specialty Turnkey Pumping Solutions for Power Generation, Desalination, Water Distribution, Irrigation, Drainage, Agriculture.

Published in: Technology, Business
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
1,152
On Slideshare
0
From Embeds
0
Number of Embeds
2
Actions
Shares
0
Downloads
24
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Transcript of "Torishima Pump general catalogue, Venezuela, Central America, Caribbean"

  1. 1. PUMP PRODUCTS GUIDE TORISHIMA PUMPMFG. CO., LTD
  2. 2. Innovative solutions coupled with expertise in pumping technology TORISHIMA is a leading pump manufacturer, founded in 1919 in Osaka, Japan. Our primary objective is to contribute to society as a quality provider of pumping equipment and services. We continue to strive to be the market leader in our field. Our on-going investment in research and development highlights our commitment to provide the best technology for our customers. Our mission is always to listen to our customers, understand their needs and their expectations. TORISHIMA MAIN PUMPS SELECTION TABLE General specification ranges for 50Hz and 60Hz types are shown below. Pumps for Fresh Water 4,000 3,000 MHG 2,000 MHB 1,500 Total head H · m 1,200 MHD 850 MSH 500 400 250 MSH-T MML CDM 100 MMO CDKTV MMK 50 30 CFV 10 CE CA Series 5 ISV 0.2 10 5 CPC CPCN CA Series 20 40 Capacity Q · m3/min 60 80 Non-Clogging Pumps Chart for Selecting Pumps by Application Multi-Stage Pumps ............................................... 20 Energy Industry....................................................... 3 Specialized Pumps ............................................... 22 Municipal Water Works, Industrial Water Works Small Capacity Water Works, Desalination Plant ... 5 Mixed-Flow Pumps ............................................... 23 Sewerage, Agriculture, Irrigation, River Water ....... 7 Submersible Pumps.............................................. 25 Axial-Flow Pumps ................................................. 24 Regional Development, Urban Development ......... 9 Mechanical Seals..................................................... 29 General Industry ................................................... 13 Service Solutions .................................................... 30 3500 35.0 HLV,HLAV 10.0 CHR 5.0 CPW CPR 1.5 CERS 0.1 5 20 30 Capacity Q · m3/min 50 70 100 CNA 20 5 10 Capacity Q · m3/min 15 300 100 0.1 CSV 10 15 40 50 Capacity Q · m3/min Miscellaneous Pumps ........................................... 27 Chemical Industry ................................................. 11 60 0.1 2500 MMTV Total head H · m Double-Suction Pumps ......................................... 19 Total head H · m Torishima Main Pumps Selection Table.................. 2 500 700 1000 1500 500 CNP Main Pumps List End-Suction Pumps .............................................. 15 100 300 Vertical Pumps for Chemical Industries 100 Content Discharge pressure MPa(kgf/cm2)G Total head H · m CPR 0.1 30 Hot Water Circulating Pumps 300 200 20 Capacity Q · m3/min Chemical Process Pumps 100 SPV 2
  3. 3. Energy Industry Condensate pump for combined cycle power plant (MMTV) Vaporizing pumps for LNG plant (SPV) Barrel type super critical boiler feed pump for coal fired power plant (MHB) Super critical pressure boiler circulating pump for thermal power plant (HLV) Ring section boiler feed pump for combined cycle power plant (MHG) Circulating water pump for coal fired thermal power plant (SPV) Page °C Max. Operating Temperature MPa Max. Operating Pressure m 1200 150 1 80 15 CE 200 to 2100 300 90 1 140 15 CHR 50 to 300 1940 125 10.8 325 16 CNP 50 to 200 850 100 1 250 17 CPC 32 to 250 1560 220 2.45 350 17 CPCN 32 to 250 1560 150 2.45 200 18 CPR 25 to 400 4320 270 4 400 18 CPW 40 to 250 1440 200 6.3 280 18 CSV 32 to 200 810 100 2.5 350 18 CDM, CDMV 200 to 33000 1400 300 1.4 80 19 CDKS 200 to 3000 500 300 350 19 CDKY 125 to 3480 400 160 210 19 CDKTV 500 to 20000 1500 100 100 19 MHB 80 to 200 2000 4200 42 200 20 MHG 40 to 250 1400 4200 42 200 20 MHD 80 to 200 300 1200 14 180 20 MMK 40 to 350 1800 150 5.4 230 21 MML 40 to 350 1800 500 5.4 230 21 MMTV EndSuction Pumps DoubleSuction Pumps MultiStage Pumps 40 to 400 2900 490 3.9 200 22 40 to 400 6000 180 32 420 22 300 to 80000 2800 100 80 23 150 to 9000 1000 70 50 to 800 4800 40 25 to 200 400 200 Specialized HLV, HLAV Mixed-Flow SPV Pumps SMRV Submersible T/B Pumps F/TB 3 Cooling by Seawater LNG, LPG Utility Geothermal Hydropower Oil LNG Sizes CAM Utility 15 Fire-Fighting 80 Crude oil 1 Underground Water Drainage 100 Stripping 600 32 to 250 Oil Product Outlet 32 to 200 Products Gas CAL Coal Max. Total Heads m3/h Horizontal/Vertical mm Horizontal/Vertical Vertical Max. Capacities Oil Storage Power Generation Applications Vertical Horizontal Ground Tank Chart for Selecting Pumps by Application Horizontal Secondary Application Underground Tank Main Application 3.2 25 40 26 26 4
  4. 4. Water supply pumps for potable water distribution pumping station (CDM) Long-distance potable water transmission pumps (CDM) Brine recirculation pumps for MSF desalination plant (CDKTV) Various seawater pumps for MSF desalination plant (CDM, SPV, SPSY) High pressure seawater feed pump for RO desalination plant (MSH-T) High pressure seawater feed pump for RO desalination plant (MSH) Max. Operating Pressure Max. Operating Temperature Page °C Max. Total Heads 1 80 15 CAM 1200 150 1.6 80 15 CAS 32 to 250 1200 150 1.6 80 15 CFV 150 to 210000 5000 100 CPC 32 to 250 1560 220 2.45 350 17 CDM, CDMV 200 to 33000 1400 300 1.4 80 19 CDKS 200 to 3000 500 300 350 19 CDKTV 500 to 20000 1500 100 100 19 MSH 100 to 1500 300 750 21 MSH-T 200 to 3000 350 800 21 MHH 150 to 300 800 800 21 MHA 125 to 200 800 800 21 MMK 40 to 350 1800 150 5.4 230 21 MML 40 to 350 1800 500 5.4 230 21 MMO, MMOV 32 to 65 130 400 4 140 22 SPV 300 to 80000 2800 100 80 23 SPSY 350 to 20000 1200 50 23 SMIV EndSuction Pumps DoubleSuction Pumps MultiStage Pumps MixedFlow Pumps 400 to 4500 700 6 25 400 to 4200 700 14 25 150 to 9000 1000 70 25 25 to 250 400 200 26 40 to 300 660 90 26 SMSV Submersible SMV Pumps F/TB F/VC, F/VD F/UW, F/SP 5 Sizes 100 Product Water 600 32 to 250 Back Wash 32 to 200 Filtered Water CAR High Pressure Feed 15 Product Water 80 Seawater Feed 1 Brine Blow Down 100 Brine Recirculation 600 Distribution 32 to 300 Products Supply CAL Intake Max. Capacities MPa Horizontal/Vertical m Horizontal/Vertical Vertical m3/h Vertical Horizontal Seawater Desalination (RO) Applications Seawater Desalination (MSF) Chart for Selecting Pumps by Application Horizontal Secondary Application mm Main Application MunicipaI Waterworks IndustriaI Waterworks Small Scale Waterworks Municipal Water Works Industrial Water Works Small Capacity Water Works Desalination Plant 16 6
  5. 5. Storm water drainage pumps for sewage treatment plant (SPV) Drainage pumps for agriculture (SP) Irrigation pumps (CDM) Sludge transfer pumps for sludge disposal plant (CNP) Waste water transfer pumps for sewage treatment plant (CFV-SM) Sewage pumps for sewage treatment plant (CFV) Horizontal/Vertical Vertical Horizontal/Vertical River Water Agriculture Max. Total Heads Max. Operating Pressure Max. Operating Temperature Page 150 1.6 80 15 CE 200 to 2100 300 90 1 140 15 CFV 150 to 210000 5000 100 16 CFV-SM 200 to 3000 600 50 16 CNA 50 to 200 500 70 1 140 17 CNP 50 to 250 850 100 1 250 17 CNS, CNSV EndSuction Pumps 80 to 250 660 70 105 17 80 19 Double-Suction CDM, CDMV Pumps Sizes 1200 Water Utilization CAM FIood Control, Water Supply 15 Irrigation, Sprinkler 80 Drainage 1 Agricultural Water 100 Storm Water Drainage Small Capacity Sewerage 600 32 to 250 Sludge Disposal Plant 32 to 300 Products Sewage Disposal Plant CAL Sewage Transfer Plant Max. Capacities Sewerage mm Applications °C Vertical Horizontal MPa Chart for Selecting Pumps by Application Horizontal Secondary Application m Main Application m3/h Sewerage Agriculture Irrigation River Water 750 21 MSH-T 200 to 3000 350 800 21 MMK 40 to 350 1800 150 5.4 230 21 MML 40 to 350 1800 500 5.4 230 21 32 to 65 130 400 4 140 22 SP 400 to 36000 2000 9 SPV 300 to 80000 2800 100 SPSY 350 to 20000 1200 50 23 SPSX 250 to 1380 350 17 24 IS 400 to 36000 2000 5 24 ISV 400 to 186000 4600 5 24 SMI, SMS 400 to 210000 5000 8 25 SMIV 400 to 4500 700 6 25 400 to 4200 700 14 25 50 to 800 4800 40 F/TB 25 to 200 400 200 26 F/VC, F/VD F/UW, F/SP AxialFlow Pumps 100 to 1500 300 MMO, MMOV MixedFlow Pumps 300 MSH MultiStage Pumps 200 to 33000 1400 40 to 300 660 90 26 10 28 SubSMSV mersible Pumps T/B, T/C, T/N Miscellaneous SNK Pumps 7 400 to 18000 3500 1.4 23 80 40 23 26 8
  6. 6. Regional Development Urban Development Pumps for air conditioning system for building facility (CAL) Cooling water pumps for district heating and cooling system (CDM) Boiler feed pumps for district heating and cooling system (MML) Cooling water pumps for district heating and cooling system (CDM) Cooling water pumps for air conditioning facility (CE) Boiler feed pumps for district heating and cooling system (MMO) Max. Operating Pressure Max. Operating Temperature Page °C Max. Total Heads 150 1.6 80 15 CAS 32 to 1200 250 150 1.6 80 15 200 to 2100 300 90 1 140 15 32 to 65 42 65 1 100 16 CNA 50 to 200 500 70 1 140 17 CPC 32 to 1560 250 220 2.45 350 17 CPCN 32 to 1560 250 150 2.45 200 18 200 to 33000 1400 300 1.4 80 19 MMK 40 to 1800 350 150 5.4 230 21 MML 40 to 1800 350 500 5.4 230 21 MMO, MMOV 32 to 65 130 400 4 140 22 50 to 4800 800 40 40 26 25 to 200 400 200 26 F/UW, F/SP 40 to 300 660 90 26 K/LP 25 to 100 84 60 100 27 15 to 80 72 300 90 27 25 to 200 300 40 40 28 40 to 150 600 75 80 28 EndCE Suction Pumps CEBS Double-Suction CDM, CDMV Pumps MultiStage Pumps T/B, T/C, T/N Submersible F/TB Pumps F/VC, F/VD Miscel- N/WR laneous Pumps TE/O S/T 9 Sizes 32 to 1200 250 Fountains CAM Sewage Treatment 15 Drainage 80 Water Supply 1 Sewage Treatment 100 Drainage 600 Water Supply CAR Vacuum Supply Water, Supply Water, Raw Water 15 Boiler Feed 80 Hot Water 1 Cold Water 100 Cooling Water 600 32 to 200 Fire-Fighting 32 to 200 Water Supply and Drainage, Sanitation CAL Products Air Conditioning Max. Capacities mm MPa Horizontal/Vertical m Horizontal/Vertical Vertical Park and Resort Facilities Intelligent Building District Heating and Cooling Applications Vertical Horizontal Airport and Harbor Facilities Chart for Selecting Pumps by Application Horizontal Secondary Application m3/h Main Application 1 10
  7. 7. Chemical Industry Process pumps for chemical plant (CPC) Process pumps for DMT plant (CPC) Cooling water pumps for petrochemical plant (CDM) Boiler feed pump for petrochemical plant (MHD) Lifting pump for chemical plant (CDKS) Cooling water pumps for oil refinery plant (CPC) Max. Operating Pressure Max. Operating Temperature Page °C Max. Total Heads 15 CAM 32 to 250 1200 150 1.6 80 15 CAS 32 to 250 1200 150 1.6 80 15 CE 200 to 2100 300 90 1 140 15 CERS 32 to 100 300 98 1.4 340 16 CNP 50 to 250 850 100 1 250 17 CPC 32 to 250 1560 220 2.45 350 17 CPCN 32 to 250 1560 150 2.45 200 18 CPR 25 to 400 4320 270 4 400 18 CPW 40 to 250 1440 200 6.3 280 18 CSV EndSuction Pumps 32 to 200 810 Sizes 80 Coal Conversion 1 Refinery 100 Utility 600 Process CAR Utility 15 Process 80 Utility 1 Process 100 Utility 600 32 to 200 Process 32 to 200 Products Utility CAL Process Max. Capacities Oil and Coal Products MPa Horizontal/Vertical m Horizontal/Vertical Vertical m3/h Vertical Horizontal Bio-Chemical Fine-Chemical Chemical Fertilizer Inorganic Chemical Applications Petro-Chemical Chart for Selecting Pumps by Application Horizontal Secondary Application mm Main Application 100 2.5 350 18 200 to 33000 1400 300 1.4 80 19 200 to 3000 500 300 350 19 MHB 80 to 200 2000 4200 42 200 20 MHG 40 to 250 1400 4200 42 200 20 MHD 80 to 200 300 1200 14 180 20 MMK 40 to 350 1800 150 5.4 230 21 MML 40 to 350 1800 500 5.4 230 21 MMTV 40 to 400 3.9 200 22 Double- CDM Suction Pumps CDKS MultiStage Pumps Mixed-Flow SPV Pumps Submersible T/B, T/C, T/N Pumps Miscellaneous N/WR Pumps 11 2900 490 300 to 80000 2800 100 80 23 50 to 800 4800 40 40 26 15 to 80 72 300 90 27 12
  8. 8. General Industry Water supply pumps for machinery plant (CAL) Treated water pumps for beverage plant (CAR) Process pumps for beer brewery plant (CAR) Furnace cooling water pump for steel plant (CDM) Cooling water pump in paper mill (CDM) Plating cooling water pumps for steel plant (CAL) Max. Operating Pressure Max. Operating Temperature Page °C Max. Total Heads 80 15 CAM, CAS 1200 150 1.6 80 15 CE 200 to 2100 300 90 1 140 15 CEBS 32 to 65 42 6.5 1 100 16 CERS EndSuction CNA Pumps CNP 32 to 100 300 98 1.4 340 16 50 to 200 500 70 1 140 17 50 to 200 850 100 1 250 17 CNS, CNSV 80 to 250 660 70 105 17 CPC 32 to 250 1560 220 2.45 350 17 CPCN 32 to 250 1560 150 2.45 200 18 CPW 40 to 250 Utility Process Utility Sizes 1 Dock Drainage 100 Food 600 32 to 250 Drainage 32 to 200 Utility CAL, CAR Products Waste Water Treatment Max. Capacities MPa Horizontal/Vertical m Horizontal/Vertical Vertical m3/h Vertical Horizontal mm Paper & Pulps Process Descaling Motor Car Machinery Ceramics New Materials Cooling Water Water Supply Nonferrous Metal Water Intake, Water Supply Applications Iron and Steel Chart for Selecting Pumps by Application Horizontal Secondary Application Shipbuilding Main Application 1440 200 6.3 280 18 200 to 33000 1400 300 1.4 80 19 MHG 40 to 250 1400 4200 42 200 20 MHD 80 to 200 300 1200 14 180 20 MMK 40 to 350 1800 150 5.4 230 21 MML 40 to 350 500 1800 5.4 230 21 MMO, MMOV 32 to 65 130 400 4 140 22 Specialized HLV/HLAV 40 to 400 6000 180 32 420 22 Mixed-Flow SPV Pumps 300 to 80000 2800 100 80 23 40 to 350 1000 230 50 to 800 4800 40 25 to 200 400 200 26 40 to 300 660 90 26 15 to 80 72 300 90 27 25 to 200 300 40 40 28 50 to 250 780 70 Double-Suction CDM Pumps MultiStage Pumps S/M SubT/B, T/C, T/N mersible Pumps F/TB F/VC, F/VD F/UW, F/SP N/WR Miscellaneous TE/O Pumps O/PS 13 26 40 26 28 14
  9. 9. CEBS Pressing stainless end-suction volute pump 5 USgpm 20 80 100 End-Suction End-Suction End-Suction Pumps 300 80 200 50 100 A motor block pump made by pressing stainless steel. The liquid contact areas are all made of stainless steel so as to be highly resistant to corrosion. The pump motor unit design allows to be compact and light-weight and easy to handle. Applications Hot water supply / Hot water circulation in building facilities, Various processes in food industries, Water and hot water supply for general industries, To prevent breakage from freezing for pump facilities in cold areas, and others CAL (Cast Iron), CAR (Stainless Steel) 10bar end-suction volute pump Taking advantage of our existing pump designs, CAL and CAR are totally optimized design pumps which adopt the efficient impeller design. The components focus on interchangeability. 20 In common with CAL and CAR as CA series, CAM and CAS are totally optimized design pumps which adopt the efficient impeller design. Applications Feed / Drainage water for general industries, Feed / Drainage water / Various processes for chemical / food industries, Cold / Hot water circulation in district heating / cooling plants, Water pumping, Fire-fighting, Water intake / Distribution / Supply for water works, Industrial water, and others CE 4000 6000 490 300 30 H m H ft 20 5 2 A single- or two-stage end-suction volute pump. Various materials and structural designs employed to meet specification requirements for a variety of applications from fresh water, chemicals and heat transfer. H ft 10 2 1 0.2 1 Capacity Total Head Temperature Pressure Size CERS 55 5 Q l/s Q m3/h 1 10 25 20 90 3 up to 42 m /h / 165 USgpm up to 65 m / 210 ft up to 100ºC / 210°F up to 1 MPa / 10 bar / 145 psi 32 to 65 mm USgpm 200 2000 4000 300 100 20 Q l/s Q m3/h 50 100 10 Capacity Total Head Temperature Pressure Size 20 200 500 350 9001400 up to 600 m3/h / 2,640 USgpm up to 100 m / 320 ft -10 to 80°C / -50 to 170°F up to 1 MPa / 10 bar / 145 psi 32 to 200 mm USgpm 100 150 1000 4000 6500 490 100 End-suction volute pump for heat transfer oil 50 100 Specialized for heat transfer oil. Effective air-cooled design leads to no requirement for cooling at shaft sealing or bearing to 340°C heat transfer oil. H m H ft 5 10 5 2 300 30 100 H m H ft Applications Dry / Agitator / Heating systems for chemical industries, Oven / Dry / Heating systems for food industries, Dry / Heating systems for general industries, and others CFV, CFV-SM Vertical mixed-flow volute pump Vertical mixed-flow volute pump with motor 2 3.3 10 50 12 Capacity Total Head Temperature Size 500 100 100 Q l/s Q m3/h 100 500 1000 3 up to 300 m /h / 1,320 USgpm up to 98 m / 320 ft up to 340ºC / 640°F 32 to 100 mm USgpm 20000 200000 1000000 300 50 100 20 5 5 2 0.8 2 10 Q l/s Q m3/h Capacity Total Head Temperature Pressure Size 20 100 100 20 50 200 100 500 350 9001500 up to 1,200 m3/h / 5,280 USgpm up to 150 m / 490 ft -40 to 80ºC / -100 to 170°F up to 1.6 MPa / 16 bar / 230 psi 32 to 250 mm USgpm 500 2000 10000 400 End-suction volute pump 30 H m 100 Applications Feed / Drainage water for general industries, Feed / Drainage water / Various processes for chemical / food industries, Cold / Hot water circulation in district heating / cooling plants, Water pumping, Fire-fighting, Water intake / Distribution / Supply for water works, Industrial water, and others 16bar end-suction volute pump 1000 100 0.8 CAM (Cast Iron), CAS (Stainless Steel) USgpm 100 150 50 10 Applicable for wide range from low head to high head. CFV-SM are a design of water resistant motor and pump. The design enables it to operate when a pump room is flooded. In addition, CFV-SM doesn’t require intermediate shaft and thus reduces construction cost. Applications Sewage transfer, Rain water drainage, Water intake / Distribution / Boosting for water works, Water pumping / Drainage for agriculture, and others CHR End-suction volute pump for hot water circulation 80 50 H m H ft 5 H m 50 CFV-SM H ft 5 10 2 30 500 100 2000 20000 20000 50000 200000 CFV 120 to 210,000 m3/h / 520 to 924,000 USgpm 3 to 100 m / 10 to 320 ft 150 to 5,000 mm Capacity Total Head Size 50 5000 Q l/s Q m3/h 200 USgpm 1000 Applicable mainly for hot water circulation of forced-circulation boilers. The forced cooling system is applied to the bearing bracket, stuffing box and base plate. CFV CFV-SM 180 to 3,000 m3/h / 790 to 13,200 USgpm up to 50 m / 160 ft 200 to 600 mm 5000 150 100 300 H ft 50 100 20 CFV 100 H m 50 10 5 Applications Water intake / Distribution / Supply / Boosting / Clarification for water works, Various processes for chemical industries, Water pumping / Drainage for agriculture, Boiler feed pump, Heat medium circulation, Heater drain, and others 15 2 1.2 10 10 40 Capacity Total Head Temperature Pressure Size Q l/s Q m3/h 100 400 3 650 2000 up to 2,100 m /h / 9,240 USgpm up to 90 m / 295 ft up to 140ºC / 280°F (340ºC / 640°F for heat medium) up to 1 MPa / 10 bar / 145 psi 200 to 300mm Applications Hot water circulation in forced-circulation boilers in thermal power plants, Petrochemical industries, Coal gasification plants, Oil refinery, and others 20 5 2 5 10 20 50 Capacity Total Head Temperature Pressure Size Q l/s Q m3/h 100 500 500 1500 3 up to 1,940 m /h / 8,530 USgpm up to 125 m / 410 ft up to 325°C / 615°F up to 10.8 MPa / 108 bar / 1,560 psi 50 to 300 mm 16
  10. 10. USgpm 100 500 1000 2000 250 Non-clogging end-suction volute pump 30 50 200 150 10 USgpm 100 1000 7000 500 100 H m CPCN End-suction volute pump for process 40 80 End-Suction End-Suction CNA 300 The discharge opening of the non-clogging impeller is produced especially wide to permit free passing of any solids measuring 50 to 70% of the pump nozzle size. 10 H ft 4 Applications Sewage transfer, Transfer / Drainage of liquids containing sludge for general industries, Transfer of grain and water mixtures, Transfer of cellulous pulp of less than 2.5% B.D. free from air, and others CNP Non-clogging End-suction volute pump Conforms to ISO2858, compact, durable and reliable based on CPC type. The design corresponding to space saving installation and high suction pressure fits in building facilities, district cooling and heating, energy related industries. Applications Transfer of corrosive liquids / abrasive liquids / chemical drainage including rough mixtures for chemical industries, Transfer / Drainage of solid mixtures for food / general industries, and others CNS, CNSV(Vertical) 2 2.5 10 10 50 50 120 200 170 500 9∼500 m3/h / 39 to 2,200 USgpm up to 70 m / 230 ft up to 140°C / 280°F 50 to 200mm Capacity Total Head Temperature Size 55 25 Q l/s Q m3/h 100 USgpm 200 2000 400 100 Applications Cooling water circulation in building facilities, Cool / Hot water / Cooling water circulation for district cooling and heating, Water pumping, Fire-fighting, Cooling systems / Water feed for deaerator / Condensate / Drain in energy industries, Water feed / Drainage for general industries CPR 4000 100 H m H ft CPC H ft 5 0.5 0 5 3 20 Capacity Total Head Temperature Pressure Size 200 1800 up to 1,560 m3/h / 6,860 USgpm up to 150 m / 490 ft -40 to 200°C / -100 to 390°F up to 2.45 MPa / 24.5 bar / 355 psi 32up to 250 mm USgpm 100 5 500 50 Q l/s Q m3/h 1000 10000 1000 300 End-suction volute pump for process 500 Simple and durable design providing high reliability. Widely used for oil refinery, petrochemical, and general industries. Series with inducer for low NPSH req. also available. 200 H m H ft 30 50 10 20 5 10 2 3.3 10 12 50 Capacity Total Head Temperature Size 30 100 Q l/s Q m3/h 270 500 Applications Processes in oil refinery / petrochemical / general industries USgpm 300 200 100 H m H ft 10 30 End-suction volute pump for hot water circulation 20 Q l/s 10 Q m3/h Capacity Total Head Temperature Size 10 100 200 100 600 1000 Centerline pump foot mounted. Mainly used as feed pump or circulation pump of hot water in large-size heating systems. Applications Feed water / Circulation in high pressure hot water generating plants 10 USgpm 1000 7000 700 Vertical centrifugal volute pump End-suction volute pump for process up to 4,320 m3/h / 19,000 USgpm up to 270 m / 885 ft -70 to 400°C / - 150 to 750°F up to 4 MPa / 40 bar / 580 psi 25 to 400 mm 500 5000 500 H ft H m 30 100 10 30 10 3 0.35 2 1 5 60 Q l/s 20 5 Q m3/h 25 Capacity Total Head Temperature Pressure Size CSV 4000 1000 100 up to 660 m /h / 2,900 USgpm up to 70 m / 230 ft up to 105°C / 220°F 80 to 250 mm 200 1200 Q m3/h USgpm 50 300 3 300 100 Q l/s 100 Capacity Total Head Temperature Pressure Size CPW 3000 10 10 960 100 3 0 3 1 up to 850 m3/h / 3,740 USgpm up to 100 m / 320 ft -30 to 250°C / -20 to 480°F 50 to 200mm 30 Applications Sewage / Sludge transfer, Pulp / Black liquid / White liquid transfer, Transfer / Drainage of solid mixtures in food / general industries, and others 50 100 End-suction volute pump with screw impeller Specially designed to handle crude sewage containing heavily contaminated solid and long-fibre admixtures liable to twist or bunch. High efficiency and high energy saving. 100 H m 10 50 Five kinds of standardized impellers available according to liquid. Applicable in various industries. The back pull-out structure and high interchangeability of this pump providing ease of maintenance. 50 100 100 500 500 2000 up to 1,440 m3/h / 6,300 USgpm up to 200 m / 670 ft up to 280°C / 530°F up to 6.3 MPa / 63 bar / 910 psi 40 to 250 mm 100 USgpm 300 1000 2000 6000 100 200 50 300 Conforms to ISO2858. A wide range of structural designs of material and seals meet various specification requirements as process pump for chemical and general industries. 50 100 H m 50 H ft 5 Applications Cooling systems / Water feed for deaerator / Condensate / Drain in energy industries, Processes in petrochemical / chemical industries, Water feed / Drainage for general industries 17 0.5 0 5 3 20 Capacity Total Head Temperature Pressure Size Q l/s Q m3/h 5 500 50 200 3 1800 up to 1,560 m /h / 6,860 USgpm up to 220 m / 720 ft up to 350°C / 660°F up to 2.45 MPa / 24.5 bar / 355 psi 32 to 250 mm Standardized vertical pump, making full use of the features of various horizontal volute pumps covering a wide range of specifications. Applications Pumping / Drainage of pit water in construction facilities / chemical / steel / power generating / pulp / food industries, and others 100 H m 50 10 H ft 15 2 3 10 15 50 Capacity Total Head Temperature Size 100 Q l/s 100 Q m3/h 300 900 3 up to 810 m /h / 3,560 USgpm up to 100 m / 320 ft -100 to 350°C / -210 to 660°F 32 to 200 mm 18
  11. 11. Double-Suction Pumps Multi-Stage Pumps Double-Suction Axially split double-suction pump The world’s most advanced high efficiency pump achieved by design to match the double suction and three-dimensional impeller with the latest hydraulics. Simple disassembly of upper half casing without disturbing pipe work enables ease of maintenance and inspection. Applications Water intake / Distribution / Boosting / Circulation / Drainage / Fire-fighting in energy industries, Cooling water circulation for district heating and cooling, Water intake / Distribution / Boosting for general industries, Water intake / Distribution / Water supply / Boosting in seawater desalination / water works / sewage, Irrigation for agriculture, Drainage, Pipe-line boosting, and others CDKY, CDKS USgpm 5000 200 500 10000 30000 MHB 50000 100000 150000 1000 300 100 Radially split barrel casing pump The barrel casing is fully welded to the pipe work and supported at its centerline on a fabricated steel base plate. The inner cartridge, which contains all pump components except the barrel and main stud bolts, is removable from the barrel as a complete unit for ease of maintenance. 300 H ft H m 100 30 CDM 5 50 300 Q l/s 500 2000 Total Head Temperature Size 500 Q m3/h USgpm 1000 3000 10000 10000 5000 MHG 500 1000 8000 13000 2000 7000 H ft H m 1000 3000 500 1500 200 5 20 20 50 100 700 700 100 Q l/s Q m3/h 200 2000 3 up to 2,000 m /h / 8,800 USgpm up to 4,200 m / 13,800 ft up to 230°C / 440°F up to 42 MPa / 420 bar / 6,090 psi up to 7,000min-1 80 to 200 mm Capacity Total Head Temperature pressure Speed Size CDMV 10000 20000 USgpm 4200 Applications Boiler feed in thermal power plants, High pressure feed water in various industries, and others 30000 180 to 33,000 m3/h / 790 to 145,200 USgpm 3 to 300 m / 10 to 980 ft up to 80°C / 175°F 200 to 1,400 mm Capacity 500 1000 100 USgpm 500 1000 4000 300 CDKS The rotating parts can be taken out by removing the side cover in axial direction. Suitable for handling high temperature and pressure liquids in chemical plants and power plants. CDKY mainly used as booster pump for boiler feed pump and hot water circulation pump. Applications Processes in power / chemical / pulp industries, and others 50 100 100 200 120 5000 Q l/s 500 Q m3/h 500 40 2000 1000 2000 5000 CDKY up to 3,480 m3/h / 15,300 USgpm up to 160 m / 520 ft up to 210°C / 410°F 125 to 400 mm 15000 30000 USgpm CDKY Applications Boiler feed in power plants, High pressure feed water in various industries, and others 350 100 Applications Brine recirculation / Brine blow down in seawater desalination plants, Hot well / Large volume condensate in geothermal power plants 19 80 H ft H m 200 50 150 40 350 1000 850 2000 1500 Q m3/h 5000 Capacity Total Head Temperature Size Q l/s 10000 4000 20000 up to 20,000 m3/h / 220,000 USgpm up to 100 m / 320 ft up to 100°C / 210°F 500 to 1,500 mm 1000 3000 1500 200 5 20 20 50 Capacity Total Head Temperature Pressure Speed Size 20 700 400 100 Q l/s Q m3/h 200 1000 up to 1,400 m³/h / 6,100 USgpm up to 4,200 m / 13,800 ft up to 200°C / 390°F up to 42 MPa / 420 bar / 6,090 psi up to 7,000 min-1 40 to 250 mm USgpm 100 2000 1000 Horizontal multistage ring section pump Radially split ring-section high-pressure multistage diffuser type pump achieving high efficiency and low NPSH. No warming through required enabling rapid start-up. Applications Boiler feed in power plants, High pressure feed water in RO desalination / various industries, and others 2000 5000 H ft 1000 300 The hydraulic design of the double-suction impeller offering low-shut off head, low NPSH and high speed. Mainly applicable for brine recirculation in seawater desalination plants and condensate in geothermal power plants when severe suction condition with large capacity and high head required. H ft CDKS up to 3,000 m3/h / 13,200 USgpm up to 300 m / 960 ft up to 350°C / 660°F 200 to 500 mm MHD 80000 7000 H m 500 100 Capacity Total Head Temperature Size Vertical double-suction pump with canister Radially split ring-section high-pressure multistage diffuser type pump. No warming through required enabling rapid start-up. H ft 30 10 20 CDKTV 400 CDKY 13000 Horizontal multistage ring section pump 100 H m 4200 2000 Horizontal radially split double-suction pump 1000 Multi-Stage CDM, CDMV(Vertical) H m 2000 400 1000 200 500 100 1 3 10 Capacity Total Head Temperature Pressure Speed Size 10 Q l/s 3 Q m /h 100 100 140 500 3 up to 300 m /h / 1,320 USgpm up to 1,200 m / 4,000 ft up to 180°C / 350°F up to 14 MPa / 140 bar / 2,030 psi up to 7,000 min-1 80 to 200 mm 20
  12. 12. MSH, MSH-T(twin-suction) Horizontal axially split multistage volute pump The axially split design offers ease of maintenance of rotating equipment without removing the lower casing. MSH-T covering high head range is twin-suction structure to satisfy high suction capability. 2000 5000 USgpm 10000 3000 MMO, MMOV(Vertical) 15000 800 2500 Multistage ring section pump MSH-T H ft MSH-T H m Compact and light-weight. Pump feet integrally cast onto bearing housings, allowing free orientation of both suction and discharge nozzles. No cooling of shaft seals required up to 140°C liquid. 1500 100 200 800 3500 2000 USgpm 3000 1000 MMTV 4000 800 2000 500 100 H ft 100 10 20 Applications Boiler feed / Condensate / Distribution for general industries, Water intake / Distribution / Water supply / Boosting for water works, Feed water / Drainage in building facilities, Cooling water / Hot and Cold water circulation, Water pumping / Drainage for agriculture, and others MSH-T up to 3,000 m3/h / 13,200 USgpm up to 800 m / 2,600 ft 200 to 350 mm MSH up to 1,500 m3/h / 6,600 USgpm up to 750 m / 2,460 ft 100 to 300 mm 1000 500 3 1 MSH 1000 3000 2000 500 2500 2 30 Q m3/h USgpm 100 500 70 250 100 up to 130 m3/h / 570 USgpm up to 400 m / 1,320 ft up to 140°C / 280°F 32 to 65 mm Capacity Total Head Temperature Size 20 10 Q l/s 10 1000 10000 Ring casing type 1000 Vertical multistage pump with canister H ft 100 The axially split design offers ease of maintenance of rotating equipment without removing the lower casing. Applicable for high to low head duty by changing the number of stages. H ft H m 1500 300 Applications High pressure seawater feed in RO desalination plants, Distribution for water works, and others 0 50 The diffuser guides flow from impeller discharge to next impeller suction eye. The axial force is compensated by a hydraulic balancing device. The integrated design accumulated by high pressure and high speed pumps results in excellent cost performance and high efficiency. Q l/s Q m3/h 400 200 300 800 2000 USgpm 3000 1000 3 1 10 10 100 10 850 100 Q l/s Q m3/h 1000 3000 up to 2,900 m3/h / 12,760 USgpm up to 490 m / 1,560 ft up to 200°C / 390°F up to 3.9 MPa / 39 bar / 565 psi 40 to 400 mm Capacity Total Head Temperature Pressure Size H ft H m 1500 300 50 100 200 Q l/s Q m3/h 400 200 300 800 1000 up to 800 m3/h / 3,520 USgpm up to 800 m / 2,600 ft 125 to 200 mm Capacity Total Head Size 30 USgpm 300 HLV, HLAV 8000 3000 500 1500 300 21 10 2500 Horizontal multistage ring section pump Applications Boiler feed in power plants, High pressure feed water in various industries, Condensate in seawater desalination, Distribution / Boosting for water works, Irrigation for agriculture, and others 100 30 Specialized Pumps 4000 800 0 Axial thrust of MMK is balanced by the impeller balance holes, and by way of MML the balance disc, so that MMK and MML can operate with high reliability at high speed. H m Applications Hot water / Condensate / High and low pressure drain in thermal power plants 1000 up to 800 m3/h / 3,520 USgpm up to 800 m / 2,600 ft 150 to 300 mm Capacity Total Head Size Applications High pressure seawater feed in RO desalination plants MMK, MML 100 200 MHA Horizontal end-suction multistage ring section pump The high pressure vertical canister pump offers significant advantage in those cases where limited suction head is available. Applicable especially for condensers in power plants, desalination plants and other pipeline pumping applications. Bowl casing type Multi-Stage / Specialized Multi-Stage Axially split multistage pump 500 1000 Capacity Total Head Size MHH 300 Q l/s Q m3/h 500 USgpm 100 H m MSH 400 Applications High pressure seawater feed in RO desalination plants, Distribution for water works, Water pumping for agriculture, and others 30 1000 1000 MML H m Glandless(sealless) pump motor unit (Boiler circulation pump) H ft MMK Pump and motor are integrated in a pressuretight casing. The glandless design (no shaft seal) makes this pump best suited for pumping of high temperature and high pressure liquids without any leakage. Volute, annular or spherical casing designs optionally available. 500 150 100 MMK 100 0 2 10 20 3 Q m /h Capacity Total Head Temperature Size 100 Q l/s 200 1000 600 2000 MMK up to 1,800 m3/h / 7,930 USgpm up to 150 m / 490 ft up to 230°C / 440°F 40 to 350 mm MML MML up to 1,800 m3/h / 7,930 USgpm up to 500 m / 1,640 ft up to 230°C / 440°F 40 to 350 mm Applications Boiler circulation in super / sub critical power plants 100 USgpm 1000 10000 30000 200 500 H ft 100 H m 200 50 100 20 1 10 10 100 Q l/s Q m3/h 1000 100 Capacity Total Head Temperature Pressure Motor Rating Voltage Size 1000 6000 up to 6,000 m3/h / 26,420 USgpm up to 180 m / 590 ft up to 420°C / 790°F up to 32 MPa / 320 bar / 4,640 psi up to 1,000 kW 400V to 11 kV 40 to 400 mm 22
  13. 13. Mixed-Flow Pumps SPSX Mixed-flow volute pump Mainly used for water pumping and drainage for agriculture. Simple back pull-out structure allowing ease of overhaul. Applications Water pumping / Drainage for agriculture, Drainage for civil engineering work, Flood control, and others 2000 20 USgpm 15 50 H m 40 H ft 10 30 20 5 100 200 400 Horizontal mixed-flow pump 10 Offering the highest efficiency in low head and large capacity range. The axially split design offering ease of maintenance of rotating equipment without removing the lower casing.  H m Applications Water pumping / Drainage for agriculture, Sewage transfer, Rain water drainage, Storm surge drainage, and others USgpm 3000 Mixed-Flow Vertical mixed-flow pump 200000 50 360 to 1,380 m3/h / 1,580 to 6,070 USgpm 5 to 17 m / 16 to 54 ft 250 to 350 mm H ft 20 10 2 150 1500 600 Q l/s Q m3/h 5000 Capacity 600 to 36,000 m3/h / 2,600 to 158,400 USgpm 2 to 9 m / 6 to 29 ft up to 40°C / 100°F 400 to 2,000 mm USgpm 3000 15000 50000 30000 300000 100 300 200 50 IS H m 50 10 H ft 15 2 150 1500 Q l/s Q m3/h 5000 600 Capacity Total Head Temperature Size SPSY 5000 60 Mixed-flow volute pump 50000 600 to 80,000 m3/h / 2,600 to 360,000 USgpm up to 100 m / 330 ft -10 to 80°C / -50 to 175°F 300 to 2,800 mm Suitable for fresh water and waste water pumping. Both open and closed type impeller available. 20000 50000 160 80 20 40 Applications Distribution / Drainage for water works / sewage, Water pumping for agriculture, Cooling water in power plants, Seawater recirculation in seawater desalination plants, and others 23 Diffuser type, axial flow propeller suspended within wet pit. Offering various hydraulic models suitable for large capacity with low pump head of water. Axially split design offering easy maintenance without removing the lower casing. 10 6 300 500 1500 1000 3000 Capacity Total Head Size 2000 Q m3/h Q l/s 10000 5000 20 10000 30000 up to 20,000 m3/h / 88,000 USgpm up to 50 m / 160 ft 350 to 1,200 mm 1000000 H m 10 2 H ft 5 1 110 400 500 20000 66000 Q l/s 5000 Q m3/h 20000 50000 200000 2000 660 to 36,000 m3/h / 2,900 to 158,400 USgpm 1.5 to 5 m / 5 to 16 ft 400 to 2,000 mm Capacity 2000 20000 6 USgpm 200000 Vertical axial-flow propeller pump H ft H m 200000 15 Total Head Size 100000 USgpm 4 ISV 40 USgpm 20000 Axial-flow propeller pump Applications Water pumping / Drainage for agriculture, Sewage transfer, Rain water drainage, Storm surge drainage, and others 15000 2000 6 Axial-Flow Applications Rain water drainage / Water intake for water works / sewage, Circulation / Cooling water / Condensate in power plants, Seawater intake / Brine recirculation in seawater desalination plants, Water intake / Cooling water in petrochemical industries, Cooling water / Water intake / Dock drainage for general industries 400 1400 Axial-Flow Pumps 100 Diffuser type, single or multistage design, mixed-flow impeller suspended within wet pit. Offering various hydraulic models, materials, and installation arrangement (above or below floor discharge) to suit the plant specific design. 300 1000 30 Total Head Temperature Size SPV 30000 Q l/s Q m3/h 700 Total Head Size 20 6000 60 Capacity SP 4000 1000000 15 4 Diffuser type, axial flow propeller suspended within wet pit. Especially used for large capacity with low head of water. The various hydraulic models applied to the change of the capacity and head. Applications Water pumping / Drainage for agriculture, River water drainage, Cooling water in power plants H m 10 2 H ft 5 1 110 400 500 2000 Capacity Total Head Size 20000 66000 Q l/s 5000 Q m3/h 20000 50000 200000 600 to 186,000 m3/h / 2,640 to 818,400 USgpm 1.5 to 5 m / 5 to 16 ft 400 to 4,600 mm 24
  14. 14. Submersible Pumps S/M Dry-type submersible motor pump Small light-weight and easy to handle. Best suited for discharging waste water at construction sites and draining water in buildings and factories. The motor is equipped with an auto-cut device, submersion detection device and protection device. The impeller is made of wear resistant materials. 500 10000 USgpm 100000 30 Horizontal tubular pump-units combining an axial-flow or mixed-flow pump and a dry-type electric motor in a single tube. Little noise and compact owing to the small water flow loss and the combined motor. Either connected directly to an electric motor or used with a reduction gear for slower rotation. 6 SMS H m H ft 10 Dry-type submersible pump Large capacity submersible propeller pumps with low head capabilities. Offering high efficiency and superior performance with compact design and easy operation. Designed to meet the requirements for efficient handling of large capacity of water. In particular, for installation, maintenance and inspection in pits, “Auto In-Pipe Column Installation type” adopted because of the high reliability and rapid discharge connections. 4 1 100 100 10 0 0 4000 Capacity Total Head Size 10000 Q l/s Q m3/h Applications Waste water / material drainage for sewage, Waste water / material drainage for construction facilities, Rain water drainage, and others 60000 40000 200000 up to 210,000 m3/h / 924,000 USgpm 2 to 8 m / 6.5 to 26 ft 400 to 5,000 mm Applications Water intake / Distribution / Drainage for water works, Water pumping / Drainage for agriculture, Industrial water / cooling water / drainage, Drainage for civil engineering work, and others 150 300 3000 15 5000 USgpm 10000 40 Submersible motor pump for deep well 10 SMSV 20 5 Vertical or horizontal submersible motor pumps with radial or mixed flow impellers, multi-stage. Water sealed three-phase induction motor is highly reliable electrically and mechanically as submersible motor, and enables less trouble and safe operation. H ft H m 10 SMIV 2 5 1 200 800 500 Q l/s 1000 Q m3/h 1000 2000 1400 5000 SMIV Capacity Total Head Size 1000 80 SMIV up to 4,500 m3/h / 19,800 USgpm up to 6 m / 19 ft 400 to 700 mm USgpm 10000 SMSV SMSV up to 4,200 m3/h / 18,500 USgpm up to 14 m / 46 ft 400 to 700 mm 200 50 Submersible motor pump for shallow well 50 10 30 Water sealed three-phase induction motor is adopted for submersible motor. Suction entry of F/VC and F/UW is located at the bottom and that of F/VD and F/SP is between pump and motor. H ft H m 10 2 1 0.8 100 50 200 Capacity Total Head Size Q l/s Q m3/h 500 2000 3000 2000 10000 3 up to 9,000 m /h / 39,600 USgpm up to 70 m / 230 ft 150 to 1,000 mm 1200 USgpm 2000 5000 Applications Water intake / Distribution / Water supply for water works, Water feed / Distribution for general industries, Water pumping for agriculture 10000 20000 40000 10 30 T/B H m H ft 2 5 3 100 Q l/s 10 400 1000 Q m3/h 2000 50 500 1000 3000 4000 T/C (Cutter) up to 72 m3/h / 310 USgpm up to 22 m / 72 ft 50 to 100 mm T/B (Bladeless) up to 4,800 m3/h / 21,100 USgpm up to 40m /130ft 50 to 800m 100 10000 USgpm 500 1000 T/B T/N (Non-clog) up to 78 m3/h / 340 USgpm up to 26 m / 85 ft 32 to 100 mm 2000 700 200 350 100 H m H ft 100 30 Applications Water intake / Distribution / Water supply for water works, Water feed / Distribution for general industries, Water pumping for agriculture F/VC, F/VD, F/UW, F/SP 40000 900 150 F/TB 20000 10 330 200 Q l/s Q m /h 600 3 up to 1,000 m3/h / 4,400 USgpm up to 230 m 40 to 350 mm Capacity Total Head Size Total Head Size SMV 25 0 100 Capacity 100 SMV is vertical tubular casing pump with submersible motor. Water-filled or oil-filled type motor is provided. SMRV uses an oil-filled type submersible motor whose suction entry is located between motor and pump. 50 1 5 10 10 Capacity Total Head Size 10 100 Q l/s Q m3/h 20 100 50 130 200 400 3 to 400 m3/h / 13 to 1,760 USgpm up to 200 m / 655 ft 25 to 200 mm 100 USgpm 1000 4000 300 Submersible Submersible Large-size submersible motor pump 1000 400 Applications Water pumping for agriculture, River drainage, Rain water drainage, Water intake / Drainage for sewage, and others SMV, SMRV H ft 50 30 Wide ranges of impellers suited for all types of sewage and effluent, especially untreated sewage containing fibers, solid admixtures, sewage sludge, circulating sludge. Removable device for ease of maintenance and inspection also available. SMI SMI Applications Water intake / Distribution / Drainage for water works, Water pumping / Drainage for agriculture, Industrial water / cooling water / drainage, Drainage for civil engineering work, and others SMIV(Axial-flow), SMSV(Mixed-flow) 300 H m 50 60 20 3 Tubular pump 5000 800 100 T/B, T/C, T/N 700000 4000 600 Submersible motor pump 2000 10 USgpm 2000 200 Applications Waste water / Sludge drainage for civil engineering works, Drainage in factories, and others SMI (Axial-Flow), SMS (Mixed-Flow) 1000 250 200 50 100 H m H ft 50 10 20 4 0.6 2 20 Q l/s 10 Capacity Total Head Size 50 200 300 Q m3/h F/VC up to 66 m3/h / 290 USgpm up to 90 m / 295 ft 40 to 100 mm 500 F/VC 1000 F/VD up to 300 m3/h / 1,320 USgpm up to 70 m / 229 ft 65 to 250 mm F/UW up to 420 m3/h / 1,850 USgpm up to 46 m / 150 ft 125 to 250 mm F/SP up to 660 m3/h / 2,900 USgpm up to 46 m / 150 ft 125 to 300 mm 26
  15. 15. Miscellaneous Pumps TE/O, TE/CO (Stainless steel) Self priming pump No need for priming. Offering outstanding self priming performance and durability. Direct-connected motor is standard. Applications For industrial facilities, construction facilities, agriculture, waste water treatment, and others 10 USgpm 200 50 50 5 100 USgpm 20 100 300 300 30 100 H m H ft 40 10 15 4 0.5 2 2 10 3 Q m /h 10 H ft 20 5 5 1 1 1 3 3 10 5 Q l/s Q m3/h 10 25 20 90 up to 84 m3/h / 370 USgpm up to 60 m / 20 ft up to 100°C / 210°F 25 to 100 mm Capacity Total Head Temperature Size N/WR Wesco pump USgpm 20 100 200 500 300 Applications Water feed / pumping for general industries, Chemical liquid transfer, Various fuel oil transfer, High pressure boiler feed, High pressure washing, and others NV Vacuum pump Suitable for pumping slurry and pulp stocks up to 5% consistency. The Impeller is Mixed flow type allowing the pump to be used for a wide range of applications. Applications Pulp liquid transfer for paper / pulp industries, Solid transfer / drainage for general industries, Fruit or cereal and water mixture transfer for food industries, and others SNK Screw Pump H m Specially-shaped impeller revolves at high speed in casing, makes the flow and absorbs up. Extremely small impeller clearance due to the use of a special method of fixing and special materials to assure high stability. Best suited for applications with small capacity and high head. 200 500 500 2000 800 H ft 200 500 100 Suitable for pumping liquids containing small stones, other suspended solids or rags, pieces of wood or ropes, digested or activated sludge etc. The simple, rugged construction and the open screw trough facilitate maintenance and inspection. 100 0 0 1 2 2 5 Q l/s Q m3/h Capacity Total Head Temperature Size 10 8 16 50 32 100 up to 72 m3/h / 310 USgpm up to 300 m / 980 ft up to 90°C / 190°F 15 to 80 mm Air Capacity up to 72 m3/min Negative Pressure up to 88 kPa Size 20 to 100 mm Applications Water pumping for treatment plants, Water pumping / Drainage for agriculture, Return sludge for sewage treatment plants, Waste water transfer, and others S/T TE/CO up to 180 m3/h / 790 USgpm up to 50 m / 160 ft 0 to 40°C / 30 to100°F 25 to 125 mm 5000 80 250 H ft 100 30 H m Applications Water and hot water circulation in building facilities, Processes for various industries, General water feed, Boosting for water works, and others 50 200 up to 780m³/h / 3,434USgpm TE/O up to 70mm229ft 300 / 3/h / 1,320 USgpm up 40 m / 130 ft 50 to 250mm 0 to 40°C / 30 to100°F 25 to 200 mm USgpm 100 50 Q l/s Pulp pump Line pump Pump and 2-pole motor close coupled with common shaft. Line construction of suction entry and discharge fits in any position into a pipeline. O/PS 2000 150 Capacity Capacity Total Head Total Size Head Temperature Size K/LP, K/SLP2 (Stainless steel) 1000 30 100 H m 50 10 30 4 0 Q l/s 10 20 50 50 400 200 1000 up to 780 m3/h / 3,430 USgpm up to 70 m / 230 ft 50 to 250 mm Capacity Total Head Size 350 1000 Q m3/h USgpm 5000 20000 50000 30 9 H m H ft 6 15 3 2 20 200 75 500 1000 Q l/s 7 5100 2000 Q m3/h 5000 10000 up to 18,000 m3/h / 79,250 USgpm up to 10 m / 32 ft 400 to 3,500 mm Capacity Total Head Size 10 100 100 USgpm 1000 4000 300 Vertical Volute Pump 200 50 The rotating, water-sealed pump sucks and exhausts gas using the centrifugal force of the liquid. Continuous gas exhaustion is made without vibration and in complete safety even when water enters in the pump interior during operation. 27 Applications Boosting / Water feed / Water pumping for general industries, and others 100 H m H ft 50 10 20 4 0.6 2 10 Q l/s Q m3/h Capacity Total Head Temperature Size 20 50 200 300 100 500 1000 3 up to 600 m /h / 2,640 USgpm up to 75 m / 240 ft 0 to 80°C / 32 to 176°F 40 to 150 mm 28 Miscellaneous Miscellaneous Applications Pump water priming, Gas exhaustion / Vacuum generation / Pressure-feeding for chemical industries Easy-installation close-coupled construction. Size 40 to 100mm back pull-out structure facilitates ease of maintenance.
  16. 16. Torishima’s Torishima’s Mechanical Seals Service Solutions Mechanical seals - the shaft seals used in rotating machinery such as pumps, hydraulic turbines, agitators and centrifuges - play an important role in maintaining the safety and economic efficiency of machinery. As a comprehensive manufacturer of pumps, Torishima has never lost sight of the importance of mechanical seals. We are the fastest in the country at moving products from the research and development phase to manufacturing and commercialization. As a premier engineered equipment supplier, Torishima is committed to provide the highest quality aftermarket service. Our innovative solutions can enhance performance and increase the life span of pumps, other equipment and plants. This allows operators to maximize efficiency, reduce maintenance costs and conserve energy. Today, we provide a wide range of mechanical seals for applications requiring high levels of safety and quality, such as mechanical seals for sealing high-temperature and high-pressure fluids in power plant pumps (including boiler feed pumps and boiler circulating pumps). We also manufacture mechanical seals for pumps used in sewage plants, chemical plants, and desalination plants handling slurry-rich liquid, special highly corrosive liquids, and seawater. Moreover, we have utilized our years of experience in pump manufacturing to provide eco-friendly non-flushing seals, easy-maintenance cartridge seals, and a variety of other optimal mechanical seals for a diverse range of applications. Mechanical Seal Applications Rubber bellows seals ● ● ● ● (Double seal) ● ● ● ● ● ● ● HB2000 Series ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● MB2000 Series ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● (Balanced type) MT2700 ● ● MB2500 ● ● ● MB2704CN ● ● ● ● ● ● ● ● ● ● ● ● MB2704CZ ● ● MB8500CZ ● ● (Inside rotating type) (Inside rotating type, with pumping ring) (Stationary inside type) (Stationary inside type, with pumping ring) ● ● ● ● ● ● ● ● ● ● MB2901 ● (Stationary balanced type, non-flushing) Split seals ● ● MT9200 Special-purpose seals For hydraulic turbines For submersible sand pumps 29 ● ● ● ● ● ● ● ● ● ● ● (Stationary balanced type, dry running application) (Balanced type) ● Energy Saving ● ● ● ● ● Torishima has the ability to combine field service engineering and product design technology. This results in our engineers being able to provide advice on improved design and the upgrade of in-site pumping equipment and other rotating equipment. upgrading to a more reliable and higher-efficiency pump. ● Reduction of energy consumption and CO2 emissions Impeller Before upgrading ● ● ● ● ● ● ● What’s REDU? Operating cost and CO2 emissions are reduced by ● ● ● ● (Stationary balanced type, dry running application) MT4100 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● MU2922 Stationary seals ● ● MB2400CN (Outside rotating type) ● ● ● ● ● ● ● ● ● ● ● ● ● Inspecting of pumping plants *REDU is a registration of trademark of TORISHIMA To improve your plant's productivity, Torishima offers longer reliable and high-efficiency pumps. In addition to servicing our own units, we restore, repair, improve and upgrade even for pumps of other manufacturers. Using the most advanced technologies, we offer products that provide you with the highest efficiency and highest possible performance. ● ● MB8500CN (Balanced type) Torishima offers targeted advice after performing a full maintenance inspection of the entire pump installation, performing necessary maintenance, and diagnosing whether the facility is being operated under the optimal conditions. When pumping equipment breaks down, our experienced engineers determine the basic cause through a full analysis and replace broken parts to ensure rapid restoration. In addition, we provide hands-on guidance and training to plant operators. Solution Provider ● (Balanced type) Cartridge seals Sand pumps ● ● ● ● ● ● ● (Unbalanced type) (Unbalanced type) Stationary multi-spring seals Hydraulic turbines ● ● ● ● ● ● ● (Balanced type) Rotating multi-spring seals Submersible pumps ● ● HU2000 Series MU2000 Series Rotating single-spring seals Electro-deposition paint pumps Cooling water pumps Process pumps ● ● ● ● ● ● ● ● ● ● LD1000 Series Torishima provides field engineering service wherever needed to supervise pump installation work and equipment commissioning, ensuring the pumping equipment can meet customer expectations. Maintenance, Overhaul, Operator Training General Industry, etc. Feed water pumps Feed water pumps Cooling water pumps Chemicals & Petrochemicals Process pumps Irrigation pumps Agricultural drainage pumps Agricultural pumps Rivers, Agriculture & Irrigation River drainage pumps Sewage treatment pumps ● ● ● Stormwater drainage pumps Water transmission & distribution pumps Product water pumps Seawater intake pumps Brine blowdown pumps Brine recirculation pumps Back wash pumps High-pressure pumps Water filtration pumps Condensate pumps ● LU1000 Series Water Works & Sewerage Seawater Desalination Cooling water pumps Boiler feed pumps Model of Mechanical Seal Boiler circulating pumps Power Generation Field and Application Installation & Field Test Impeller After upgrading Upgrade ● ● ● Existing pump High-efficiency pump Existing pump Highefficiency pump Casing Casing 30
  17. 17. PUMP PRODUCTS GUIDE TORISHIMA PUMPMFG. CO., LTD

×