Leon Plus Engl 1.2 Leon Plus Engl 1.2 Presentation Transcript

  •  
  • Production Leon, Leon plus, etc.
    • (S) IMV (Synchronized)
    • Intermittend Mandatory Ventilation
    • (S) PCV (Synchronized)
    • Pressure Controlled Ventilation
    • PSV Pressure Supported
    • Ventilation
    • Man. Manual Ventilation
    • Spont. Spontaneous Ventilation
    • HLM – Mode (optional)
    • Heart – lung machine
    Ventilation Modes
  • Description Patient module
    • Patient module
    • Fresh gas decoupled
    • Tempered:
    • preventing condensation
    • warming respiratory gas
    • APL decoupled during controlled ventilation
    • Visual observation of the „Hanging Bellow“
    • Patient module
    • Inspiratory and expiratory flow sensors
    • Absorber can be exchanged during operation
    • Can be fully sterilized
    • Compliance compensated
    Patient module
  • CO 2 - Absorber
    • New Absorber
    • Volume complete 2000 ml
    • Fill limit 1750 ml
    • Longer operating time
    • Exchange during operation
    • Easy in handling
  • Features
    • 15“ TFT color display
    • Operation via touchscreen and / or control knob
    • Electronic fresh gas blender
    • One - hour rechargeable battery buffering
    • Two Interface connections RS 232
    • Ethernet interface
    • Gas monitor with automatic detection of
    • anesthetic gas and anesthetic gas mixture
  • Features
    • Receptacle for two anesthetic vaporizers
    • Undercarriage with 4 antistatic rollers, all with
    • brakes
    • 4 Drawers
    • 1 cupboard reserve bottle connections for O² and
    • N²O
    • Pull out writing surface, DIN A4
    • Rails on right and left to fit support arms and
    • other accessories
  • O ² Safety Flow System
    • Mechanic Valve (independent from Voltage)
    • Settings 0 – 15 l/min.
    • Use for quick start (emergency)
    • Use for device is turned off
    • Use for fail of fresh gas blender
  • Gas Management
    • Sidestream Monitor with real time measurement and real time graphs
    • Paramagnetical O ² measurement
    • Different water trap for exactly measures in patient category „child“
  • Configuration of the options panel
    • Solution for half open breathing
    • system
      • Kuhn
      • Jackson Rees
      • Magill
      • Bain
  • Configuration of the options panel
    • Solution „external O ² outlet“
    • O ² – Flowmeter adjustable between 0 – 15 l / min.
  • Pressure gauges and control elements O ² flush Turn switch for vacuum dosing Vacuumdosing Vacuum pressure O ² bottle pressure N ² O bottle pressure
  • New Ventilation Mode
    • PSV Pressure Supported Ventilation
    • Psv provides pressure support during insufficient spontaneous breathing.
    • If the Leon plus is not triggered by the patient after the adjustable apnoe time, the Leon plus initiates inspiration on ist own.
    • In addition, you can use a button to start a manual breath, not activated by the patient.
  • New Ventilation Mode
    • HLM – Mode (Heart – Lung machine mode)
    • Mode is working on a CPAP Level
    • Measurement of CPAP
    • Without any patient alarm
    • Stopwatch for time of bypass
  • Real time graphs and complete Measurement
  • Fresh gas control
    • Air or N 2 O as carrier gas
    • Set percent oxygen to total fresh gas flow
    • Set total fresh gas flow
    • Setting range
    • 200 ml / min. – 18 l / min.
    • Ensure O 2 concentration in O 2 / N 2 O mixture of 25 % (Ratio)
    • Ensure O 2 concentration in „Minimal Flow“ (up from 200 ml/min.) is with 100%, adapted to the flow
  • Fresh gas control
    • Backup Emergency bottles (2 – 3 litres)
    • Anlog pressure gauges in front
    • Reservegas bottles
    • (10 litres) with digital input (optional)
    • Digital bottle pressures in the window „thresholds“
  • Systemtest
    • New Systemtest
    • Traffic light system (green, yellow, red)
    • Clear optical information
    • Repetition of the tests one by one
    • comment window
    • Self explanable
  • Real time graphs
    • Values as real time graphs
    • Airway pressure
    • Flow
    • Volume
    • CO ² (%, hPa or mmHg)
    • O ²
    • N ² O
    • Halothane
    • Enflurane
    • Isoflurane
    • Sevoflurane
    • Desflurane
  • Values displayed in numerical form
    • Real time measurement:
    • Minute volume, tidal volume, Peak / Plateau / Mean pressure, PEEP, Frequency
    • Calculated values:
    • MAC, Compliance dyn., Compliance stat., C20/C, Resistance
    • Adapted values:
    • CPAP (only in HLM – Mode)
  • Loops
    • One Loop at a time can be displayed in full screen
  • Loops
    • Loop window
    • Three loops can be displayed in the Loops window
      • Volume over pressure
      • Flow over pressure
      • Flow over volume
    • Alarm limits for monitoring (adjustable)
    • Function of „Autoset“
    • Alarms with three different priorities (high, medium, informal)
    • Complete history of alarms in the Log
    • Complete history of events in the Event Log (only in Standby)
    • Adjustable loudness of alarm tone
    • Gas supply pressure
    Thresholds
  • Different Solutions
    • Ceiling swingarm mount Wall mount
  • More Solutions