Remote detection of illegal usage of electricity
Upcoming SlideShare
Loading in...5
×

Like this? Share it with your network

Share

Remote detection of illegal usage of electricity

  • 441 views
Uploaded on

Remote detection of illegal usage of electricity

Remote detection of illegal usage of electricity

More in: Education
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Be the first to comment
    Be the first to like this
No Downloads

Views

Total Views
441
On Slideshare
441
From Embeds
0
Number of Embeds
0

Actions

Shares
Downloads
47
Comments
0
Likes
0

Embeds 0

No embeds

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
    No notes for slide

Transcript

  • 1. March 8, 2014
  • 2. ARUN.M S5 EEE 11031069 March 8, 2014
  • 3. March 8, 2014
  • 4. • 1950 : at a frequency of 10 hz , 10 kw of power , one way: town lighting , remote relay control • 1980 : beginning of researches into the use of electrical power grid to support data transmission • 1997: first tests for bidirectional data signal transmission over the electrical supply network and beginning of research by Ascom(Switzerland) and Norweb(UK) • 2000 : First test carried out in France by EDF R&D and March 8, 2014 Ascom
  • 5.  In India the largest democracy with an estimated population of about 1.04 billion is on the road to rapid growth in economy because of electricity The theft of electricity is a criminal offence If an automatic Meter Reading system via power line communication is set in a power delivery system a detection system for illegal usage of electricity is possible Power line communication has many new service possibilities on the data transferring via PL with out extra cables March 8, 2014
  • 6. 1) Using mechanical objects 2) Using the external phase before meter terminals 3) Switching the energy cables at the meter connector box 4) Using a fixed magnet March 8, 2014
  • 7.  The AMR system starts at the meter. Some means of translating reading from rotating meter dials into digital form is necessary in order to send digital metering data from the customer to a central point. A optical sensor is used to convert the ordinary meter rotation into the digital form. One such technique using optical sensor is shown in the figure . March 8, 2014
  • 8. Rotating disc in Meter housing Incident ray Signal out Reflected ray Marker March 8, 2014 Optical sensor
  • 9. 1) Meter interface module 2) Communication system 3) Central office system equipments March 8, 2014
  • 10. Power line carrier communication take place over the same line that deliver electricity This technique involve injecting a high frequency AC carrier in to the power line and modulating this carrier with data originating from the meter or central station  the practice of using medium-voltage (11 to 33kv) and low voltage ( 100 to 400) power distribution lines as high speed PLC communication means and optical network as backbone network is common March 8, 2014
  • 11. BASE STATION MODEM METER MODEM March 8, 2014 MODEM METER
  • 12. March 8, 2014
  • 13. March 8, 2014
  • 14. Subscriber Subscriber 1 Kwh Kwh PLC 2A PLC 1A PLC 220V AC 2 1B PLC Energy 2B Meter DISTRIBUTION TRANSFORMER PLC NB Host PLC Unit Kwh PLC NA March 8, 2014 To Central Station Energy Meter Subscriber N Energy Meter
  • 15. Energy meter chip PLC modem kWh meter Power line s Host PLC Modem Illegal load March 8, 2014 Legal load PLC modem Optical reflector system disk
  • 16. 1) Every user has two PLC modems 2) An second energy meter must be installed 3) The host PLC unit must be placed in the distribution transformer 4) The host PLC modem and its controller must include two address per every user March 8, 2014
  • 17. March 8, 2014
  • 18.  There is no need of extra cables and wires  Accelerating the economic growth  Very suitable for smart grid project  The initial and running cost are low  Distribution loses are reduced March 8, 2014
  • 19. March 8, 2014
  • 20.  Breakdown of power line will affect  There needs more modems  Looping from the pole may possible  There should be a host PLC unit near all the distribution transformer March 8, 2014
  • 21. March 8, 2014
  • 22. APPLICATIONS  Leakage current detection  Public lighting ( street lighting )  Power system fault detection  Measurement/Control/Energy-management of electrical power equipments for electrical power companies  Automatic Meter Reading March 8, 2014
  • 23.  Home security  The remote monitoring /control of electrical house hold appliances  Online games  Home network (LAN)  Remote billing March 8, 2014
  • 24. CONCLUSION  the proposed detector system to determine the illegal electricity usage via power line communication is very useful and successful.  The system proved that if AMR and detector system are used together illegal usage of electricity might be detected.  Once this proposed detection system are tried in real power lines , the distribution losses in India can be reduced effectively March 8, 2014
  • 25. REFERENCE  I.H. Cavder , “A Solution to remote detection of ….. “ IEEE Transaction on power delivery , vol.19  Yoshinori Mizugai and Masahiro oya , world trends in power line communication Mitsubishi Electric  The magazine electrical for you 2012 march edition  Tom D Tamar kin “ automatic meter reading “ Public Power magazine vol.50 number 5 September - October 1992  The website www.yuvaengineers.com March 8, 2014