Your SlideShare is downloading. ×
  • Like
Sharmila Devices
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×

Now you can save presentations on your phone or tablet

Available for both IPhone and Android

Text the download link to your phone

Standard text messaging rates apply

Sharmila Devices

  • 256 views
Published

 

  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Be the first to comment
    Be the first to like this
No Downloads

Views

Total Views
256
On SlideShare
0
From Embeds
0
Number of Embeds
0

Actions

Shares
Downloads
6
Comments
0
Likes
0

Embeds 0

No embeds

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
    No notes for slide

Transcript

  • 1. WELCOME
  • 2. HEALTH DEVICES AND ITS COMMUNICATION
  • 3.
    • State-of-the-art health monitoring devices and services has recently become more and more publicized and in some cases accessible in the form of test-applications.
    • currently available telemonitoring devices use as many as different wireless standards
    • * Bluetooth, Zigbee, Ant, 900 MHz , WiFi
    • * GPS
    • * Ultra-wideband
    • * 3G Long Term Evolution
    • * 4G Mobile Systems
  • 4.
    • A variety of sensors are available to measure physiological state associated with health and fitness.
    • These are devices for measuring body weight, blood pressure, glucose levels, oxygenation, respiration and even heart activity by using low-cost ECG sensors.
    • Increasingly, a second class of devices emerges which are worn on the body for 24 hours and collect data on multiple sensory channels as long as up to 7 days.
  • 5. COMMUNICATION
  • 6. Technologies Involved
    • Short and medium range wireless networks
    • Miniaturized sensors
    • Battery technology
    • Combination of these technologies are creating a variety of opportunities for remotely monitoring patient’s physiological functions and for providing information to and support for patients in managing their own health
  • 7. DEVICES
  • 8.  
  • 9.  
  • 10.  
  • 11. Cardiac Monitoring
    • Introduced in( Despopoulos, 1994),the battery powered Holter monitor, records the heart signals named ECG (electrocardiogram), for 24 or 48 hours.
    • Vitaphone-sensors integrated into standard cell phone, takes electrocardiogram reading at any time.
    • There are other commercial monitoring systems that use PDAs to store the ECG signals, e.g. Ventracor (Ventracor, 2003), Cardio Control (Cardio Control, 2003). GSM/GPRS
    • PDA-Holter: the ECG signals is processed to detect wave events(ECG signal processing)
    • Algorithm: a Fortran implementation (Jané, 1997) of an on-line detection algorithm developed by Pan & Tompkins (Pan,1985).
    • Receives the bit chains and translates them into a standard format that the whole system understands.
  • 12. CONTINUED..
    • The rhythm detection delays obtained is because the detection algorithm used needs the previous beat types and the next three ones, in order to detect the rhythm for the current beat.
    • For packages of one second the PC achieves an average of 4.43 seconds in obtaining the rhythm,meanwhile the PDA needs 10.3 seconds, but, as the processing cannot be performed in real time, the rhythm detection delay would grow if the experiment duration were longer.
    The time needed for system to notify an alarm is T notify = t rhythm detection + t alarm compression + t communication latency
  • 13. Micro Power Oximeter
    • Fast, reliable SpO2 and Pulse Rate measurements on any patient.
    • Data is transmitted from the oximeter board to the host at a rate of 60 packages per second.
    • Data is formatted in 4 byte packets.
    • The Micro Power Oximeter Board communicates with the host computer through a single, high-speed asynchronous serial channel at 3.3V CMOS levels.
    • Data provided to the host includes %SpO2 (8 pulse beat average as well as instantaneous)
  • 14. Onyx II 9560
    • Fingertip pulse oximeter
    • Bluetooth wireless technology
    • Oxygen Saturation Display Range- 0-100%spO2
    • Pulse Rate Display Range- 18 to 321 beats/min
    • Measurement Wavelengths and Output Power
    • * Red: 660 nanometers @ 0.8 mw maximum average
    • * Infrared: 910 nanometers @ 1.2 mw maximum average
  • 15. GlucoTel blood sugar monitoring
    • Measures the blood sugar level and then sends the test results using Bluetooth technology to the patient's cell phone.
    • The transmission from the cell phone to the internet database is done either by cell phone internet connection or normal text messaging. Both ways are automatic and do not require user interaction.
    • Other products are Pressure Tel and Weight Tel
  • 16.  
  • 17. REFERENCES
  • 18.
    • http://www.bodytel.com/en/patient/products/the_system.html
    • http://www.nonin.com/productsList.asp?PageID=2000&sec=1&sub=0
    • www. draeger - medical .com/MT/internet/EN/us/about/press/2005/doc/press_05_56e_masimo.pdf
    • ursafe.tesa.prd.fr/ursafe/new/CM/articles/paper014.pdf