Your SlideShare is downloading. ×
Integrity All Ultrex Series Windows INSERT APPLICATION Measuring Instructions
Integrity All Ultrex Series Windows INSERT APPLICATION Measuring Instructions
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×
Saving this for later? Get the SlideShare app to save on your phone or tablet. Read anywhere, anytime – even offline.
Text the download link to your phone
Standard text messaging rates apply

Integrity All Ultrex Series Windows INSERT APPLICATION Measuring Instructions

111

Published on

Published in: Education
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
111
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
2
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. 12012-01-12 19972219 Integrity All Ultrex Series Windows Replacement Measuring Instruction Integrity All Ultrex Series Windows Replacement Measuring Instruction Before You Begin These measuring instructions cover the following product types: All Ultrex Casement (IFCA), All Ultrex Single Hung and Double Hung (IFSH and IFDH). Before beginning installation be sure to inspect the existing opening for any signs of rot, decay, or other deterioration. It is essential that all substrates and sheathing be solid and free from defects to ensure proper installation. If the above conditions are not met, please take corrective action and repair and/or replace components as necessary. Products are manufactured 1/2"(13) narrower in width and height than rough opening (R.O.). It may be necessary to cover the resulting gap with trim after installation. NOTE: Numbers listed in parentheses () are metric equivalents in millimeters to the nearest whole number. Required Measurements NOTE: Integrity All Ultrex units are built 1/2"(13) narrower and 1/2"(13) shorter than Rough Opening dimensions which are used for ordering in Order Management System (OMS). Add 1/8"(3) to inside opening width and 1/4"(6) to inside opening height to obtain the proper dimension to enter into OMS rough opening fields. 1. Inside Opening Width (A): Measure inside of frame at three locations: the sill, center of jambs, and head jamb. Record the narrowest measurement. NOTE: Do not measure width from parting stops, blind stops, hardware, or weather strip. 2. Inside Opening Height (B): Measure inside of frame at three locations: left side, center, and right side. Record the shortest measurement. 3. Stool Height (C): (For use on Casement Installations only) Measure the stool height and record. If the stool height is over 1 7/16” modification to the existing sill may be necessary. Recommended Measurements 4. Measure the width of the blind stops from the inside opening to the edge of the blind stop (D). If width exceeds 1/2"(13), modification to the blind stop or an exterior installation may be necessary. 5. Measure Jamb pocket depth (E). If depth is less than 3 1/4"(83), modification to the pocket may be necessary. (Exterior installation is recommended for pocket depths less than 3 1/4".) 14 Degree Existing Sill Flat Existing Sill
  • 2. 22012-01-12 19972219 Integrity All Ultrex Series Windows Replacement Measuring Instruction * If blind stop width exceeds 1/2" (13), modifications may be necessary. ** If less than 3 1/4" (83) or greater than 3 1/2" (89), modifications may be necessary. Required Measurement Recommended Measurement Window Number / Location Product Description A B C Calculated R.O. for OMS D ERO Width = A + 1/8” ROHeight = B + 1/4” Site Map Follow the steps on the previous page to fill in this worksheet. (A) Inside opening Width (narrowest width) (B) Inside Opening Height (C) Stool Height (D) Blind Stop Width* (E) Jamb Pocket Depth** PROJECT MEASURED BY: DATE:

×