• Save
Ultrassom
Upcoming SlideShare
Loading in...5
×
 

Like this? Share it with your network

Share

Ultrassom

on

  • 644 views

 

Statistics

Views

Total Views
644
Views on SlideShare
644
Embed Views
0

Actions

Likes
0
Downloads
0
Comments
0

0 Embeds 0

No embeds

Accessibility

Categories

Upload Details

Uploaded via as Adobe PDF

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

Ultrassom Presentation Transcript

  • 1. 30/07/2013 1 Paulo R. Fonseca – prfonseca@gmail.com Aplicações Ondas & Som Modo A Modo B Modo M Doppler Artefatos http://29.media.tumblr.com/tumblr_l9kpb75Zex1qzhehpo1_500.jpg
  • 2. 30/07/2013 2
  • 3. 30/07/2013 3  Guia de biópsias  Fisioterapia
  • 4. 30/07/2013 4  Classificação:  Origem ▪ Mecânica: perturbação de um meio material ▪ Eletromagnética: cargas elétricas oscilantes (vácuo)
  • 5. 30/07/2013 5  Classificação:  Direção de oscilação ▪ Transversal: direção de oscilação é perpendicular à direção de propagação ▪ Longitudinal: oscilação ocorre na mesma direção da propagação  Classificação:  Tipo de energia transmitida ▪ Sonora ▪ Térmica ▪ ...
  • 6. 30/07/2013 6  Comprimento de onda (λ)  Amplitude (A)  Freqüência (Hz)  Intensidade (Watts/cm2)  Período (T)
  • 7. 30/07/2013 7
  • 8. 30/07/2013 8  Densidade (r)  Velocidade de propagação  v = λ · f  Impedância acústica  Z = r · v  Densidade x Compressibilidade
  • 9. 30/07/2013 9
  • 10. 30/07/2013 10  Energia transportada pela onda  classifica um som em forte ou fraco At E I  2 4 r P I   A intensidade do som pode ser expressa em função da amplitude do deslocamento horizontal dos elementos de volume de ar. )( 2 2  r A v I  e Zv r Impedância Acústica
  • 11. 30/07/2013 11  Sensação auditiva não varia linearmente com a energia transportada  dB: decibel  I: intensidade  I0: limiar de audibilidade 10-12(W/m2)
  • 12. 30/07/2013 12
  • 13. 30/07/2013 13 Cristal PZT Material Amortecedor Camada de interposição Transdudor
  • 14. 30/07/2013 14
  • 15. 30/07/2013 15
  • 16. 30/07/2013 16  O transdutor é projetado para ter resposta máxima a uma certa freqüência  Determinado pela espessura  Quando menor espessura  menor o comprimento de onda  maior a freqüência  Freqüência ressonante de um cristal de PZT-4 com 1mm de espessura  Sabe-se que a velocidade do som nesse material é 4000 m/s  Considerando que a oscilação é máxima quando a onda incidente é igual ao dobro da espessura do cristal  2 x 10-3 = 2.10-3  v=fl  f=4000 /2.10-3 =2.106=2 MHz
  • 17. 30/07/2013 17  Combinação de vários sensores em  Linha  Matriz  Anel  Geometria depende da aplicação
  • 18. 30/07/2013 18  Tipicamente n.º > 256 elementos  1 mm x 10 mm  Imagem retangular  Direcionamento (focalização) obtido  Eletronicamente  Com auxílio de lentes
  • 19. 30/07/2013 19
  • 20. 30/07/2013 20 Freqüência 2-10 MHz Velocidade de Propagação 1400 – 1700 m/s Freqüência de repetição do pulso 2-10 KHz Ciclos por pulso 1-3 Duração do pulso 0,5-3 ms Comprimento espacial do pulso 0,1-1 mm Intensidade espacial máxima 0,01-100 mW/cm2 Coeficiente de atenuação 1-5 dB/cm
  • 21. 30/07/2013 21 Construtiva A = A1 + A2 Destrutiva A = A1 – A2
  • 22. 30/07/2013 22
  • 23. 30/07/2013 23
  • 24. 30/07/2013 24  X’=r2/l  X’ = “profundidade” da zona de Fresnel  r = raio do transdutor  l = comprimento de onda
  • 25. 30/07/2013 25      2 2 2 4 ZbZa ZaZb T ZbZa ZbZa R      Lembrar: Uso do gel
  • 26. 30/07/2013 26
  • 27. 30/07/2013 27  A agulha da biópsia
  • 28. 30/07/2013 28  Quando o feixe de ultra-som muda de um meio para outro  a velocidade muda  mudança no comprimento de onda  frequência é a mesma  Ocorrência de artefatos
  • 29. 30/07/2013 29  É o coef. de atenuação x eII   0 Approximate Attenuation Coefficient Values forVarious Materials Material Coefficient (dB/cm MHz) Water 0.002 Fat 0.66 Soft tissue (average) 0.9 Muscle (average) 2.0 Air 12.0 Bone 20.0 Lung 40.0 Pulse Amplitude Loss Produced by a Reflection Interface Amplitude Loss (dB) Ideal reflector 0.0 Tissue-air -0.01 Bone-soft tissue -3.8 Fat-Muscle -20.0 Tissue-water -26.0 Muscle-blood -30.0
  • 30. 30/07/2013 30
  • 31. 30/07/2013 31
  • 32. 30/07/2013 32
  • 33. 30/07/2013 33
  • 34. 30/07/2013 34
  • 35. 30/07/2013 35  Utilizado em ecoencefalografia  Associado com o modo B para exatidão de profundidade
  • 36. 30/07/2013 36
  • 37. 30/07/2013 37 Computador Amplitude Profundidade Ganho =+  Localização das estruturas de interesse  Imagem estática e de tempo real
  • 38. 30/07/2013 38
  • 39. 30/07/2013 39  Ecocardiografia
  • 40. 30/07/2013 40
  • 41. 30/07/2013 41  Mecânica  Cristal oscilatório e girante em meio aquoso  Eletrônico  rede de cristais com aplicação de pulsos controlados eletronicamente  Eletrônico e mecânico  Para a geração de imagens em 3D
  • 42. 30/07/2013 42
  • 43. 30/07/2013 43
  • 44. 30/07/2013 44  Time gain compensator  Delay  Intensidade  Coarse gain  Reject  Near gain  Far gain  Enhancement
  • 45. 30/07/2013 45
  • 46. 30/07/2013 46
  • 47. 30/07/2013 47 Frequência Profundidade da imagem Largura do feixe Resolução Lateral Comp. Espacial do pulso Resolução axial Ciclos por pulso Resolução axial Frequência Resolução axial
  • 48. 30/07/2013 48           f ap vv v ff           f af vv v ff
  • 49. 30/07/2013 49  Identificação de estruturas móveis  Caracterização do fluxo sanguíneo v fV f cos2 
  • 50. 30/07/2013 50
  • 51. 30/07/2013 51
  • 52. 30/07/2013 52 Usando contraste de microbolhas
  • 53. 30/07/2013 53
  • 54. 30/07/2013 54
  • 55. 30/07/2013 55
  • 56. 30/07/2013 56
  • 57. 30/07/2013 57
  • 58. 30/07/2013 58
  • 59. 30/07/2013 59  Feixe com energia >100 mW/cm2 produz efeitos  Térmicos: ▪ aumento da temperatura ▪ tratamento de patologias musculares, tendinosas ou ósteo-articulares  Não-térmicos: ▪ Micromassagem ▪ Aumento da permeabilidade da membrana celular
  • 60. 30/07/2013 60  Efeito térmico - esse efeito tem permitido o seu uso para o tratamento de patologias musculares, tendinosas ou ósteo-articulares. 2ML DURANTE 10 S DURANTE 30 S Líquido T(0C) Gelatina 1 Água 2 Álcool 3,5 Glicerina 10 Parafina 10 Ácido esteárico 36 Cera 44 Líquido T(0C) Ágar 0 Albumina 2 Fígado 9 Cérebro 9,5 Gema de ovo 11 Gordura 25
  • 61. 30/07/2013 61  Micromassagem  Oriundo das oscilações provocadas pelo feixe ultra- sônico  movimentação dos tecidos aumenta a circulação de fluidos intra e extracelulares  facilitando a retirada de catabólicos e a oferta de nutrientes.  Aumento da permeabilidade da membrana celular  Feixe é capaz de alterar os potenciais de membrana  aumento da condutância da membrana ao potássio
  • 62. 30/07/2013 62  Vasoconstrição ou vasodilatação arteriolar  feixes pulsados  (4-10W/cm2)  costrição arteriolar ou vasodilatação ▪ abrir capilares em zonas de isquemia crônica.  Cavitação e efeitos pressóricos.
  • 63. 30/07/2013 63  “Ultra-som: princípios físicos e formação de imagem” – Prof. Dr. Marcos Fontes IBB/Unesp  “Princípios Físicos e Formação de Imagem em Ultra-Som” – Profa. Dra. Diana R. Pina Miranda – FMB/Unesp  “Basic Physics of ultrasound imaging” – John E. Aldrich (Crit. Care Med 2007 Vol 35 n.º 5)