Caption data limited ez tomas training guide

1,024 views

Published on

EZ Tomas traing guide for use in conjunction with the IOTech range of vibration analyzers

Published in: Technology, Business
0 Comments
1 Like
Statistics
Notes
  • Be the first to comment

No Downloads
Views
Total views
1,024
On SlideShare
0
From Embeds
0
Number of Embeds
6
Actions
Shares
0
Downloads
20
Comments
0
Likes
1
Embeds 0
No embeds

No notes for slide

Caption data limited ez tomas training guide

  1. 1. 1<br />ZonicBook/618EZ-TOMASRotating Machinery Monitoring and Analysis<br />www.captiondata.com<br />
  2. 2. 2<br />ZonicBook/618EZ-TOMASRotating Machinery Monitoring and Analysis<br />Agenda <br />Getting Started<br />Machines & Instrumentation<br />ZonicBook/618 eZ-TOMAS<br />Project Data File Concepts<br />Gauge Monitor Display <br />Acquisition, Instrument, and Storage Setups<br />Spectral Bands, RPM Ranges, and Limit Setups<br />Display Preferences<br />Analysis Displays<br />Historical Data Reports<br />Limit Checking<br />Project Security<br />www.captiondata.com<br />
  3. 3. 3<br />ZonicBook/618EZ-TOMASGetting Started – Applications and Machinery<br />PetroChemical, Power Utility, Paper and Steel Mill, Pharmaceutical, etc…<br />Turbines, Compressors, Gearboxes, Pumps, Motors, Generators, etc…<br />Typically, 1 to 3 machines per system.<br />10 to 100,000 RPM range<br />Temporary or Continuous Monitoring<br />www.captiondata.com<br />
  4. 4. 4<br />ZonicBook/618EZ-TOMASGetting Started - Instrumentation<br />Accelerometers / Velocity<br />Proximity / Displacement<br />Tachometer / Speed<br />Pressure Transducers<br />Temperature Sensors<br />Microphones<br />General or Static<br />www.captiondata.com<br />
  5. 5. 5<br />ZonicBook/618EZ-TOMASGetting Started – Project Data File Concepts<br />Microsoft Windows 2000, or XP OS<br />EZ-TOMAS Project<br />1 to 3 Machines per Project<br />1 Project Per Windows Folder<br />FIFO Design<br />Fixed Input Channel Count<br />www.captiondata.com<br />
  6. 6. 6<br />ZonicBook/618EZ-TOMASGetting Started – System Startup<br />System Startup & Initialization<br />ZonicBook/618E Power & Ethernet<br />PC Log On<br />Verify Connectivity<br />Start eZ-TOMAS<br />www.captiondata.com<br />
  7. 7. 7<br />ZonicBook/618EZ-TOMASGetting Started – Creating / Opening A Project<br />www.captiondata.com<br />
  8. 8. 8<br />ZonicBook/618EZ-TOMASGauge Window<br />www.captiondata.com<br />
  9. 9. 9<br />ZonicBook/618EZ-TOMASConfiguration Setups<br />Project Information<br />Configuration<br />Acquisition, Input Channels, Storage<br />Spectral Bands<br />Machine Faults<br />Spectral Limits<br />RPM Limit Sets<br />www.captiondata.com<br />
  10. 10. 10<br />ZonicBook/618EZ-TOMASEdit – Project Information<br />www.captiondata.com<br />
  11. 11. 11<br />ZonicBook/618EZ-TOMASConfiguration Setup - Acquisition<br />www.captiondata.com<br />
  12. 12. 12<br />ZonicBook/618EZ-TOMASConfiguration Setup – Input Channels<br />www.captiondata.com<br />
  13. 13. 13<br />ZonicBook/618EZ-TOMASConfiguration Setup – Input Channels<br />www.captiondata.com<br />
  14. 14. 14<br />ZonicBook/618EZ-TOMASConfiguration Setup – Tach Channels<br />www.captiondata.com<br />
  15. 15. 15<br />ZonicBook/618EZ-TOMASConfiguration Setup – Storage<br />www.captiondata.com<br />
  16. 16. 16<br />ZonicBook/618EZ-TOMASEdit -Spectral Bands<br />www.captiondata.com<br />
  17. 17. 17<br />ZonicBook/618EZ-TOMASEdit –Spectral Limits<br />www.captiondata.com<br />
  18. 18. 18<br />ZonicBook/618EZ-TOMASGauge Window – Monitor Vibration Levels<br />www.captiondata.com<br />
  19. 19. 19<br />ZonicBook/618EZ-TOMASGauge Window – Monitor Vibration Levels<br />www.captiondata.com<br />
  20. 20. 20<br />ZonicBook/618EZ-TOMASGauge Window – Monitor Vibration Levels<br />www.captiondata.com<br />
  21. 21. 21<br />ZonicBook/618EZ-TOMASGauge Window – Monitor Vibration Levels<br />www.captiondata.com<br />
  22. 22. 22<br />ZonicBook/618EZ-TOMASEdit - Display Preferences<br />www.captiondata.com<br />
  23. 23. 23<br />ZonicBook/618EZ-TOMASAnalysis Displays<br />Display - Plots…<br />Realtime or Historical Data Source<br />1 to 8 Windows<br />8 Display Types<br />Up to 8 Traces per Window<br />Interactive Display Options<br />www.captiondata.com<br />
  24. 24. 24<br />ZonicBook/618EZ-TOMASPlot Windows – Data Source Options<br />www.captiondata.com<br />
  25. 25. 25<br />ZonicBook/618EZ-TOMASPlot Windows – Time Waveform<br />www.captiondata.com<br />
  26. 26. 26<br />ZonicBook/618EZ-TOMASPlot Windows – Spectrum<br />www.captiondata.com<br />
  27. 27. 27<br />ZonicBook/618EZ-TOMASPlot Windows – Orbit<br />www.captiondata.com<br />
  28. 28. 28<br />ZonicBook/618EZ-TOMASPlot Windows – Waterfall<br />www.captiondata.com<br />
  29. 29. 29<br />ZonicBook/618EZ-TOMASPlot Windows – Bode<br />www.captiondata.com<br />
  30. 30. 30<br />ZonicBook/618EZ-TOMASPlot Windows – Polar<br />www.captiondata.com<br />
  31. 31. 31<br />ZonicBook/618EZ-TOMASPlot Windows – StripChart (Trend)<br />www.captiondata.com<br />
  32. 32. 32<br />ZonicBook/618EZ-TOMASPlot Windows – Shaft Center Line (SCL)<br />www.captiondata.com<br />
  33. 33. 33<br />ZonicBook/618EZ-TOMASPlot Windows – Right Click Options<br />www.captiondata.com<br />
  34. 34. 34<br />ZonicBook/618EZ-TOMASStatistical Data Analysis<br />www.captiondata.com<br />
  35. 35. 35<br />ZonicBook/618EZ-TOMASGauge Window – Monitor Vibration Status<br />www.captiondata.com<br />
  36. 36. 36<br />ZonicBook/618EZ-TOMASHistorical Data Reporting<br />Display – Alarm Log<br />Display – SnapShot Log<br />www.captiondata.com<br />
  37. 37. 37<br />ZonicBook/618EZ-TOMASUser Security<br />Security – User Level<br />Level 1 thru 3<br />Project Password<br />www.captiondata.com<br />
  38. 38. 38<br />ZonicBook/618EZ-TOMASData Export Options<br />www.captiondata.com<br />

×