23 new honeywell flame detectors from dticorp.com

  1. 1. 23 New Honeywell FlameDetectors From DtiCorp.comHoneywell C7204E,F 24 Vdc Flame Detectors are solid-state electronic devices for sensingthe ultraviolet radiation emitted by the combustion of most carbon containing fuels such asnatural gas, LP gases, and oil.Fort Lauderdale, FL - Popular Honeywell online retailer DtiCorp.com (http://www.DtiCorp.com) isintroducing 23 brand new Honeywell Flame Detectors. The combustion flames of most carbon-basedfuels emit sufficient ultraviolet radiation to enable the C7024 Solid State Purple Peeper Ultraviolet FlameDetector to prove flame presence in a combustion chamber. The detector is mounted outside thecombustion chamber. Its mounting flange or union is threaded to one end of a sight pipe inserted throughthe wall of the combustion chamber. The ultraviolet sensing tube in the flame detector sights the flamethrough the pipe. When a flame is present, the UV tube in the C7024 senses the ultraviolet radiationemitted. The C7024 produces a signal that is sent to the amplifier in the flame safeguard control. Theamplified signal pulls in the flame relay in the control to allow proper operation of the system. Because itis necessary for the UV sensing tube to actually see the flame, it is best to locate the detector as close tothe flame as physical arrangement, temperature, and other restrictions permit.Features:- Use with R7824C Dynamic Self-Check Flame Signal Amplifier.- Circuitry provides low power consumption and high reliability.- Mount horizontally, vertically or at any angle in between.- Field-replaceable UV radiation sensing tube and quartz viewing window.- Quick electrical installation with threaded conduit fitting and color-coded leadwires.- Reduce nuisance shutdowns by wiring two in parallel.
  2. 2. - Oscillating shutter interrupts UV radiation using the R7824C amplifier.- C7024E meets NEMA 4 standards with viewing window rated to 20 psi.- C7024F has an explosion-proof housing for use in hazardous atmospheres with a viewing window ratedto 100 psi.Specifications:- Ambient Temperature Ratings (outside the case): C7024E,F: -20° F to +175° F (-29° C to +79° C).- Storage Temperature Ratings: -60° F to +175° F (-51° C to +79° C).- Housing: Violet, cast aluminum cover; mounting flange with heat block and faceplate are separate toprovide heat insulation and sealoff. Meets NEMA 4 enclosure requirements (indoor, outdoor protection;rain-tight, dust-tight, hose-directed water).- Mounting: Mounting flange with 3/4 inch NPT internal threads for attachment to sight pipe.- Wiring Connections: NEC Class 1 color-coded lead-wires, 8 feet (2.4 meters) long.- Serviceability C7024E and F: Field replaceable viewing windows and ultraviolet sensing tube, self-checking coil and shutter assembly.- Approvals: For use in hazardous locations; Class 1, Groups C and D; Class 2, Groups E, F and G; Fileno. E34649; Canadian Standards Association Certified.Models Available: - C7024 Solid State Purple Peeper Ultraviolet Flame Detector.24 Vdc solid state electronic flame detectors for sensing the ultraviolet radiation emitted by thecombustion of most carbon containing fuels, such as natural gas, LP gases, and oil.1. C7024E1001 24 Vdc Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking, 24 Vdc2. C7024F1009 24 Vdc Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking, Explosion Proof, 24Vdc - C7027 Minipeeper Ultraviolet Flame Detector.Compact Flame Detector for use with flame safeguard controls with ultraviolet amplifiers.3. C7027A1023 Flame Sensor, Ultraviolet, Minipeeper4. C7027A1031 Flame Sensor, Ultraviolet, Minipeeper5. C7027A1049 Flame Sensor, Ultraviolet, Minipeeper6. C7027A1056 Flame Sensor, Ultraviolet, Minipeeper7. C7027A1064 Flame Sensor, Ultraviolet, Minipeeper
  3. 3. 8. C7027A1072 Flame Sensor, Ultraviolet, Minipeeper9. C7027A1080 Flame Sensor, Ultraviolet, Minipeeper10. C7027A1114 Flame Sensor, Ultraviolet, Minipeeper - C7035 Minipeeper Ultraviolet Flame DetectorCompact flame detector for use with flame safeguard controls with ultraviolet amplifiers.11. C7035A1023 Flame Sensor, Ultraviolet, Minipeeper12. C7035A1031 Flame Sensor, Ultraviolet, Minipeeper13. C7035A1049 Flame Sensor, Ultraviolet, Minipeeper14. C7035A1056 Flame Sensor, Ultraviolet, Minipeeper15. C7035A1064 Flame Sensor, Ultraviolet, Minipeeper16. C7035A1080 Flame Sensor, Ultraviolet, Minipeeper - C7044 Minipeeper® Ultraviolet Flame DetectorsCompact flame detector for use with flame safeguard controls with ultraviolet amplifiers.17. C7044A1006 Flame Sensor, Ultraviolet, Minipeeper - C7927 Solid State Ultraviolet Flame DetectorThe Solid State Ultraviolet Flame Detectors detect the ultraviolet radiation emmited by combustionflames. The flame detectors are used with Honeywell flame safeguard controls to provide flamesupervision for gas, oil, or combination gas-oil burners.18. C7927A1016 Electronic Ultraviolet Flame Detector - C7961 Ultraviolet Flame DetectorA self-checking flame detector using a solid state UV sensor to detect ultraviolet radiation in flames forsupervision of gas, oil or combination gas-oil burners.19. C7961E1006 Dynamic Self-checking Solid State Sensor Ultraviolet Flame Detector20. C7961E1022 Dynamic Self-checking Solid State Sensor Ultraviolet Flame Detector
  4. 4. 21. C7961F1004 120 Vac Dynamic Self-checking Ultraviolet Flame Detector - C7962 Visible Light Flame DetectorThe C7962B Visible Light Flame Detector detects the visible light emitted by fuel oil combustion flames.The C7962B Detector is used with Honeywell Flame Safeguard controls to provide fuel oil flamesupervision in commercial and industrial burners.22. C7962B1002 Visible Light Flame Detector23. C7962B1010 Visible Light Flame DetectorAbout Us: DtiCorp.Com (http://www.DtiCorp.com) carries more than 35,000 HVAC products,including industrial, commercial and residential parts and equipment from Honeywell, JohnsonContols, Robertshaw, Jandy, Grundfos, Armstrong and more. Our online catalog is easy tonavigate and search, and all products have a picture and a description. If a customer has anyquestions about a product, they can call 800-757-5999 and speak with one of our productexperts. Our mission is to offer the best prices anywhere to our customers.Julian ArhireManager DtiCorp.comPhone: 954.298.2515Fax: 954.206.0767Web: http://www.DtiCorp.com###DtiCorp.com, Honeywell, Flame Detector, combustion flames, fuels, ultraviolet radiation, SolidState Purple, Peeper Ultraviolet, flame presence, combustion chamber, detector, sensing tube,UV tube, radiation emitted, amplifier, flame relay, UV sensing tube, flame, temperature, C7024,C7035, C7044, C7927, C7961, C7962